• Title/Summary/Keyword: T.H.D.

Search Result 4,694, Processing Time 0.046 seconds

Studies on the Molybdenum Complexes with Tetradentate Schiff Base Ligand (I). N,N'-bis (Salicylaldehyde)-ethylene Diimine (네자리 Schiff Base 리간드의 몰리브덴착물에 관한 연구 (제1보))

  • Jo, Gi Hyeong
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.4
    • /
    • pp.267-271
    • /
    • 1974
  • The tetradentate schiff base, N,N'-bis(salicylaldehyde)-ethylene diimine has been reacted with a series of Mo(IV), Mo(V), Mo(IV), and Mo(III) oxidation states to form new Complexes; $[MoO_2(C_{16}H_{14}O_2N_2)], (MoO(C_{16}H_{14}O_2N_2)]_2O, (Mo(SCN)(C_{16}H_{14}O_2N_2)]_2O, and (Mo(H_2O)(C_{16}H_{14}O_2N_2)]_2O.$ These complexes have hexa coordinated configurations and the mole ratio of these ions to the ligand was 1:1. These complexes have been identified by visible spectra, infrared specra, T.G.A., D.T.A., and elemental analysis.

  • PDF

Effects of Chromium Supplementation and Lipopolysaccharide Injection on Physiological Responses of Weanling Pigs

  • Lee, D.N.;Weng, C.F.;Yen, H.T.;Shen, T.F.;Chen, B.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.4
    • /
    • pp.528-534
    • /
    • 2000
  • Sixteen specific pathogen free 4-wk-old crossbred weanling pigs were allotted into a $2{\times}2$ factorial design to evaluate chromium picolinate (CrPic) on growth and physiological responses. Two factors included (1) no Cr or 400 ppb Cr supplementation from chromium picolinate and (2) lipopolysaccharide (LPS) injection on day 21 (d 21) and 35 (d 35) compared to saline application. Plasma samples and rectal temperature were obtained from all piglets before (h 0) and at 2 h (h 2), 4 h (h 4), 8 h (h 8), and 24 h (h 24) after LPS injection ($200{\mu}g/kg$ BW, intraperitoneally). The rectal temperature on d 21 was significantly decreased (p<0.05) of about $0.36^{\circ}C$ with Cr supplementation before LPS injection. After LPS injection, the daily gain of piglets was decreased during d 35-38. Supplementation of Cr had no effect in general on growth performance particularly after LPS injection. The plasma glucose, triglycerides and urea nitrogen concentrations were changed in different ways after LPS injection. Plasma cortisol level was significantly elevated at h 2 after LPS injection on d 21 and d 35. The supplementation of Cr in the diet can delayed plasma cortisol release on d 35. The results suggest that 400 ppb Cr supplementation from CrPic may modulate the physiological response during immune stress in weanling pigs.

Design of a Rectangular Waveguide Antenna for Automotive Side and Rear Radar Sensor Applications (차량 측후방 레이더 센서용 직사각형 도파관 안테나 설계)

  • Lee, Jae-Min;Ryu, Hong-Kyun;Woo, Jong-Myung;Koo, Bon-Hee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.1
    • /
    • pp.42-52
    • /
    • 2012
  • In this paper, a waveguide antenna is designed and fabricated for side and rear radar sensor of vehicles in UWB (Ultra Wide Band) high band (center frequency : 9.5 GHz, -10 dB bandwidth : 600 MHz (6.4 %)). For the radar antenna, a probe fed rectangular waveguide antenna having simple structure and wide bandwidth is used. An important performance factor in this antenna is the isolation between transmitting (TX) and receiving (RX) waveguide antennas because this radar system uses TX and RX antennas separately. Thus the isolation between two antennas was simulated for E-plane and H-plane array. As a result, it was verified that the isolation of the H-plane array of the antennas is better than E-plane array, due to the TE10 mode. Therefore, H-plane arrayed waveguide antennas were mounted on a T-shaped radar module and performance of antennas was investigated. The -10 dB bandwidth of the TX and RX antenna mounted on T-shaped radar module was measured as 1000 MHz (10.52 %) and 1090 MHz (11.47 %) respectively and the isolation is less than -50 dB in the operation band. The peak gain is 7.65 dBi for the TX antenna and 7.26 dBi for the RX antenna and the beamwidth of H-plane of TX and RX antenna was measured as $64^{\circ}$ and $65^{\circ}$ respectively. Consequently, we verified that the proposed waveguide antenna is appropriate for a vehicle radar applications.

Status of the KSTAR Toroidal Field Coil Structure Fabrication

  • Choi, C.H.;Sa, J.W.;Park, H.K.;Hong, K.H.;Shin, H.;Kim, H.T.;Her, N.I.;Yang, H.L.;Kwak, J.H.;Moon, H.G.;Yoon, H.H.;Lee, S.K.;Song, J.Y.;Chu, Y.D.;Hur, D.K.;Nam, K.M.;Koo, B.H.;Lim, J.H.;Lee, J.K.;Kim, N.G.;Jang, S.W.;Kim, H.C.;Ha, E.T.;Bak, J.S.;Lee, G.S.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.1036-1037
    • /
    • 2005
  • PDF

Pharmacokinetics of oxytetracycline in olive flounder (Paralichthys olivaceus) by intramuscular injection (Oxytetracycline을 근육 주사한 넙치 (Paralichthys olivaceus)의 약물동태학적 특성)

  • Jung, Sung-Hee;Choi, Dong-Lim;Kim, Jin-Woo;Jo, Mi-Ra;Seo, Jung-Soo;Ji, Bo-Young
    • Journal of fish pathology
    • /
    • v.22 no.1
    • /
    • pp.91-95
    • /
    • 2009
  • The pharmacokinetic properties of oxytetracycline (OTC) were studied after intramuscular injection to cultured olive flounder, Paralichthys olivaceus. Plasma concentrations of OTC were determined after dosage of 12.5, 25 and 50 ㎎/㎏ body weight in olive flounder (average 600 g, $23{\pm}1{^{\circ}C}$). Plasma samples were taken at 3, 5, 10, 15, 24, 32, 48, 72, 120, 168, 240 and 360 h post-dose. With 25 and 50 ㎎/㎏, the peak plasma concentrations of OTC, which attained at 5 h post-dose, were 0.99 and 1.49 $\mu{g}/m\ell$, respectively. However, the peak plasma concentration of 12.5 ㎎/㎏ was 0.35 $\mu{g}/m\ell$ after 10 h post-dose. Plasma concentrations of OTC were not measurable at 360 h post-dose in all doses. The kinetic profile of absorption, distribution and elimination of OTC in plasma were analyzed fitting to a 1-compartment model by Win-Nonlin program. The following parameters were calculated for 12.5, 25 and 50 ㎎/㎏ body weight, respectively: AUC (the area under the concentration-time curve)?D���D24.98, 44.67 and 50.45 $\mu{g}$ $h/m\ell$ $T_{1/2}$ (half-life) ?D���D0.42, 0.59 and 0.41 h; $T_{max}$ (time for maximum concentration)?D���D8.46, 6.34 and 2.66 h; $C_{max}$ (maximum concentration)?D���D0.30, 0.63 and 1.13 $\mu{g}/m\ell$.

Assessment of the Effectiveness of a Natural Antimicrobial substance on Salmonella enteritidis using Response Surface Analysis (반응표면 분석을 이용한 Salmonella enteritidis의 증식 효능 평가)

  • 홍정미;정효준;이홍근
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1307-1313
    • /
    • 2002
  • This study was performed to investigate the single and combined effect of concentrations of garlic juice according to the pH and temperature on the growth of Salmonella enteritidis in brain heart infusion broth, and to develope Response surface model for the effect of concentrations of garlic extract. The results of electric conductibility of Salmonella enteritidis growing in the range of incubation temperature ($25~42^{\circ}C$), pH (5.5~9.0) and concentration of garlic Juice (0~0.8%) showed that a badge with high temperature had low D.T.value and concentration of garlic extract were significantly correlated with D.T.value (p<0.01). Growth of Salmonella enteritidis in the condition of $37^{\circ}C$ and pH 7.0 presented the lowest D.T.value.

On the Estimates of Radiation on Horizontal Surface During Winter in Korea (동계 한국의 수평면 일사량 추정에 관하여)

  • 한영호
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.13 no.1
    • /
    • pp.7-10
    • /
    • 1977
  • In estimates of horizontal radiation, its values are determined by correlations among the length of day, noon altitude of the sun, and cloud amount. During winter from 1971 to 1974 in Korea, its correlations are calculated by empirical method are $$Q_o=0.0124 H_cT_d at clear day and$$ $$ Q_s=0.0124 H_cT_d (1-0.0C4^1.3) at cloudy day.$$ here$ Q_o, Q_s, H_c, T_d, C $ are horizontal radiation at clear day, horizontal radiation at cloudy day, noon altitude of the sun, length of day, and cloud amount. In applications of this equation at 10 stations in Korea, errors are less than 10% when cloud amount are less than 7, and 1O~20% when cloud amount are more than 7. But, according to Laevastu equation in same case, errors are 50% closely.

  • PDF

Design and Implementation of a Video-conference System supporting H.323 and SIP (H.323과 SIP를 지원하는 영상회의 시스템의 설계 및 구현)

  • Seong, Dong-Su
    • The KIPS Transactions:PartD
    • /
    • v.10D no.3
    • /
    • pp.521-530
    • /
    • 2003
  • Various multimedia application services have been developed with techniques of high speed networks and computer. Among these services, a video-conference system over internet is useful and important, and its standardization has been shown in ITU-T H.323 and IETF SIP. H.323 standardization is currently used in many products, but two standardizations will coexist for a long time. Since the interoperability is needed between two standardizations, H.323-SIP gateway is developed for it. In audition, a video-conference system supporting two standardizations is necessary to be developed. We have implemented the video-conference terminal supporting both ITU-T H.323 and IETF SIP standardizations over internet. The system implementation has been designed using the common modules of two standardizations maximally, and the interoperability among different systems is satisfied through experiments.

T—S Fuzzy Model-based Sampled-data Observer Design for Detecting Internal Oil Leakage in Single-rod Hydraulic Cylinder: LMI Approach (편로드 유압실린더 내부 누유 검출을 위한 T—S 퍼지 모델 기반 샘플치 관측기 설계: LMI 접근법)

  • Jee, Sung Chul;Kim, Hyogon;Park, Jeongwoo;Lee, Mun-Jik;Kang, Hyungjoo;Li, Ji-Hong
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.405-414
    • /
    • 2016
  • This paper presents an internal oil leakage detection problem for a hydraulic single-rod cylinder. We derive the dynamics of the hydraulic cylinder as a state space model, and then design a T—S fuzzy model-based fault detection observer. We adopt an H observer design scheme so that the observer is robust against disturbance and relatively sensitive to the leakage fault. Sufficient design conditions are derived in the form of linear matrix inequalities. A numerical example is provided to verify the proposed techniques.