• Title/Summary/Keyword: T-test verification

Search Result 335, Processing Time 0.032 seconds

Confirmation on Basic Adhesion Strength Property Testing of Domestic Rubber Asphalt Waterproofing Sealant in Accordance JC/T 2428 Chinese Industrial Standard for the Establishment of Korea-China Joint Quality Standards (고무 아스팔트 씰의 한중 공동 품질기준 제정을 위하여 국내 재료를 중국업계표준 JC/T 2428의 부착강도 적용시 기본물성 확보 여부 확인)

  • An, Ki-Won;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.226-227
    • /
    • 2019
  • Installation and usage methods are currently different between China and Korea for the same rubber asphalt waterproofing sealant. Quality verification is not properly carried out in this situation, so it is necessary to secure reliability in order to export domestic materials to China. In this study, rubber asphalt waterproofing sealant used as injection-type leakage repair material was tested in accordance to adhesion strength quality test method outlined in the JC/T2428 Chinese Industrial Standard to confirm the basic performance is compliant or not.

  • PDF

Clinical Application of Gamma Knife Dose Verification Method in Multiple Brain Tumors : Modified Variable Ellipsoid Modeling Technique

  • Hur, Beong Ik;Lee, Jae Min;Cho, Won Ho;Kang, Dong Wan;Kim, Choong Rak;Choi, Byung Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.102-107
    • /
    • 2013
  • Objective : The Leksell Gamma Knife$^{(R)}$ (LGK) is based on a single-fraction high dose treatment strategy. Therefore, independent verification of the Leksell GammaPlan$^{(R)}$ (LGP) is important for ensuring patient safety and minimizing the risk of treatment errors. Although several verification techniques have been previously developed and reported, no method has ever been tested statistically on multiple LGK target treatments. The purpose of this study was to perform and to evaluate the accuracy of a verification method (modified variable ellipsoid modeling technique, MVEMT) for multiple target treatments. Methods : A total of 500 locations in 10 consecutive patients with multiple brain tumor targets were included in this study. We compared the data from an LGP planning system and MVEMT in terms of dose at random points, maximal dose points, and target volumes. All data was analyzed by t-test and the Bland-Altman plot, which are statistical methods used to compare two different measurement techniques. Results : No statistical difference in dose at the 500 random points was observed between LGP and MVEMT. Differences in maximal dose ranged from -2.4% to 6.1%. An average distance of 1.6 mm between the maximal dose points was observed when comparing the two methods. Conclusion : Statistical analyses demonstrated that MVEMT was in excellent agreement with LGP when planning for radiosurgery involving multiple target treatments. MVEMT is a useful, independent tool for planning multiple target treatment that provides statistically identical data to that produced by LGP. Findings from the present study indicate that MVEMT can be used as a reference dose verification system for multiple tumors.

COMS DATS Implementation and Test (통신해양기상위성 데이터 송수신 서브시스템의 구축 및 시험)

  • Park, Durk-Jong;Kim, Su-Jin;Ahn, Sang-Il
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.4
    • /
    • pp.459-470
    • /
    • 2008
  • DATS which is one of three subsystems of IDACS is responsible to receive Sensor Data, LRIT and HRIT in L-Band and transmit LRIT and HRIT in S-Band from/to COMS satellite. This paper shows detailed test procedures used to verify the performance and functionality of DATS after its implementation was completely finished. As a part of efforts to verify key DATS performance, G/T and EIRP were measured by using solar flux density as radio source. Regarding the verification of DATS functionality, RF loop-back test was conducted to validate if there is no BER degradation excepting MODEM/BB implementation loss occurred in the integrated DATS. Integrated with 13m antenna, DATS successfully restored image from received MTSAT-1R broadcasting data, LRIT and HRIT, of which frequencies are all L-Band. S-Band transmission was also verified through test antenna placed away from 13m antenna by measuring real LRIT and HRIT spectrum in S-Band. From those test results, DATS is determined to be fully ready to communicate with COMS in L-Band and S-Band.

Development and Evaluation of Patient Safety Reporting Promoting Education Program (환자안전보고 촉진 교육프로그램의 개발 및 평가)

  • Kim, Myoung-Soo;Kim, Yun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.284-295
    • /
    • 2012
  • The purpose of this study was to develop and evaluate patient safety reporting promoting strategy for nurses to improve nursing care quality. The process included three phase - construction, implementation and evaluation phase. Before the construction phase has two kinds of subcategories as analysis and verification. Analysis phase was consisted of literature review and field study, and verification was conducted by two specialist. At the construction phase, patient safety reporting system, educational materials, planning for public relation, and reward preparation were developed. After implementation during 12 weeks, we evaluated pre-post scores of satisfaction, stress of conscience, job performances. The participants were 51 nurses working for a hospitals. The program was developed and then administered to the experimental group for 12 weeks. One group pretest-posttest design was used for this study. Data were analyzed using descriptive analysis, paired t-test with the SPSS WIN 18.0 program. After the intervention, job performance scores improved significantly from 3.62 to 3.75(t=2.653, p=.009). But job stress didn't changed significantly(t=.785, p=.434). These strategy can be applied to many clinical setting that will be helpful to promote patient safety reporting for nurses.

Study on the control conformance testing of IEC 61850 based IED (IEC 61850기반 IED대상 제어 적합성 시험에 관한 연구)

  • Jang, B.T.;Lee, N.H.;Kim, J.H.;Kim, B.H.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.122-124
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 communication service test on IED trial products developed related to power IT project "The verification of Performance of the Substation Automation System and Its Field Test". This paper describes control testing, one of the IEC 61850 conformance testing items, which consists of DO, enhanced DO, SBO and enhanced SBO with a number of test cases.

  • PDF

A Study on the Field Test of IEC 61850 based Substation Automation System (IEC 61850 변전자동화시스템 실증시험에 관한 연구)

  • Lee, N.H.;Jang, B.T.;Kim, B.H.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.250_251
    • /
    • 2009
  • IEC 61850 based substation automation system mainly consists of human machine interface as a client and a various of IEDs as a server. Both of them should require the field testing for performance verification including IEC 61850 communication services. This means that the test can assure the interoperability of IEC 61850 based substation automation system consisted of multi vendor's products. This paper shows a research result on the field test of the IEC 61850 based HMI and IEDs. And it proposes some engineering solutions for the system implementation.

  • PDF

Experiment and verification of the O-ring test (O-링 테스트의 실험적 검토)

  • 최기훈;김영탁;여인철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.64-67
    • /
    • 2000
  • It is usual that the medical examination of human body need special knowledpe and equipments. Thus we have to spend Lime and energy on going to special place such as hospital where doctors and equipments are. Which often cause missing a good chance af medical treatment as well as giving us inconvenience. However many simple and convenient equipments were developed for checking our health conditions recently. O-ring test is accepted a3 one of useful methods to examine our heallb conditions. Also the test is recognized as a uscful means to judge, withoul any special equipment and medical knowledge, if some medical substances or foods are beneficial or harmful to our health. However, the judgement may be mcorrect because it depend on doctor's subjective point of view.In this study, we developed an automatic O-ring t a r mach~ne which enable us to check our health conditions objectively and quantitatively. The validity of the idea to develope the machine was proved by experiments.

  • PDF

Experimental Test for the Optimum Design of a Rotor Slot in Three Phase Inverter-fed Induction Motor (3상 인버터 구동 유도전동기의 회전자 1 슬롯 최적설계에 관한 실험)

  • Kim, J.W.;Kwon, B.I.;Kim, B.T.;Jo, Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.131-134
    • /
    • 2002
  • The optimum design technology using combind F.E.M and eauivalent circuit is so fast and accurate that it can be applied to the optimum rotor design of an inverter-fed induction motor in high efficiency motor making industry. The optimum characteristics fer a rotor slot model of a 3 phase inverter-134 nduction motor was previously verified by a time-step F.E.M. In this paper, four verification models with the design variables near the optimum point are designed to chech whether the characteristics of a slot model presented is not less than those of the near models. The outputs of whole models are analyzed in a time-step Finite Element Method and compared in the experimental test. The economical and efficient selecting method of design variables fur the computer simulation and experimental test is presented in order to assure the optimum point.

  • PDF

A Study on the Evaluation of Turbine Efficiency through the Performance Test of New Power Plant (신규 화력발전소의 성능 시험을 통한 터빈 효율의 평가에 관한 연구)

  • Kweon, Y.S.;Chung, H.T.;Jung, Y.B.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.11-20
    • /
    • 2001
  • Super-critical type steam power plant, which operates with steam pressure above the super-critical point, has a good reputation recently and is adopted as a new standard of the Korean Electric Power Corporation. The reason for the good reputation lies in it's superior power efficiency. However, the field data of the new power plant for the verification of it's performance are still insufficient, and more empirical data are needed to acquire technologies on the effective operation of it. In this study, the authors analyzed the field test data on power efficiencies got in a super-critical type steam power plant, and evaluated the excellency of the new plant by comparing the efficiency data with the one got in a conventional sub-critical type steam power plant.

  • PDF

the GOOSE Communication Test of IEC 61850 based IED (IEC 61850기반 IED GOOSE 통신시험)

  • Lee, N.H.;Lee, M.S.;Jang, B.T.;Han, J.Y.;Song, I.J.;An, Y.H.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.263-266
    • /
    • 2009
  • IEC 61850 based substation automation system is operating with Generic Object Oriented Substation Event message when an IED need to send an important signal to other IEDs or receive the signals from another IED such as trip and interlock. So interoperability of substation automation system may be assured throughout the verification of IED GOOSE. This paper shows a testing contents for GOOSE subscription and publish of IEC 61850 based IED and describes how to analysis the result of GOOSE testing. Now domestic IED completed by GOOSE test of this study are working in KEPCO test field.