• Title/Summary/Keyword: T-ray Imaging

검색결과 87건 처리시간 0.18초

Exploring the Diffuse X-ray Emission of Supernova Remnant Kesteven 69 with XMM-Newton

  • Seo, Kyoung-Ae;Hui, Chung Yue
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권2호
    • /
    • pp.87-90
    • /
    • 2013
  • We have investigated the X-ray emission from the shock-heated plasma of the Galactic supernova remnant Kesteven 69 with XMM-Newton. Assuming the plasma is at collisional ionization equilibrium, a plasma temperature and a column absorption are found to be kT ~ 0.62 keV and $N_H{\sim}2.85{\times}10^{22}\;cm^{-2}$ respectively by imaging spectroscopy. Together with the deduced emission measure, we place constraints on its Sedov parameters.

Importance of 3-dimensional imaging in the early diagnosis of chondroblastic osteosarcoma

  • Laura Althea Cuschieri;Rebecca Schembri-Higgans;Nicholas Bezzina;Alexandra Betts;Arthur Rodriguez Gonzalez Cortes
    • Imaging Science in Dentistry
    • /
    • 제53권3호
    • /
    • pp.247-256
    • /
    • 2023
  • The aim of this report is to present a case of chondroblastic osteosarcoma located in the right maxillary premolar region of a 17-year-old female patient. The initial clinical presentation and 2-dimensional (2D) radiographic methods proved inadequate for a definitive diagnosis. However, a cone-beam computed tomography scan revealed a hyperdense, heterogeneous lesion in the right maxillary premolar region, exhibiting a characteristic "sun-ray" appearance. To assess soft tissue involvement, a medical computed tomography scan was subsequently conducted. A positron emission tomography scan detected no metastasis or indications of secondary tumors. T1- and T2-weighted magnetic resonance imaging showed signal heterogeneity within the lesion, including areas of low signal intensity at the periphery. Histological examination conducted after an incisional biopsy confirmed the diagnosis of highgrade chondroblastic osteosarcoma. The patient was then referred to an oncology department for chemotherapy before surgery. In conclusion, these findings suggest that early diagnosis using 3-dimensional imaging can detect chondroblastic osteosarcoma in its early stages, such as before metastasis occurs, thereby improving the patient's prognosis.

1.0Tesla 자기공명 영상장치에서의 혈관조영기법에 관한 연구 (MR Angiography at 1.0Tesla MR Unit)

  • 이윤;류택현;오창현;안창범;이흥규;김종효
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.528-532
    • /
    • 1997
  • X-Ray Angiography has been gold standard or imaging of blood flow. However, patients have to take many risks such as catheterization procedure, iodine contrast agent and ionizing X-rays. MR Angiography has been suggested as a substitute for its non-hazard to patient. But the resolution and contrast was inferior to that of X-ray Angiography. Recently the resolution and the contrast have been much improved due to the development of fast imaging technique.

  • PDF

6mm$^{t}$ 조선용 Primer코팅강판의 $CO_2$레이저 용접성 (III) - X-선 투과영상시스템에 의한 결함형성거동의 리얼타임관찰 - (The Weldability of 6mm$^{t}$ Primer-coated Steel for Shipbuilding Using $CO_2$ Laser (III) - Real-time X-ray Imaging Observation of Defect Formation of Laser Welding -)

  • 김종도;박현준;이종봉;김영식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.103-105
    • /
    • 2004
  • 키홀 용접현상에 관한 연구는, 키홀 현상이 용융금속내부에서 아주 빠른 속도로 과도적으로 이루어지기 때문에 그 계측과 해석이 곤란하여 수 많은 가정이나 가설 하에서 용입형상과 키홀의 거동에 관한 해석이 국한된 영역에서 이루어지고 있는 것이 현실이다. (중략)

  • PDF

Unveiling the direct conversion X-ray sensing potential of Brucinium benzilate and N-acetylglcyine

  • T. Prakash;C. Karnan;N. Kanagathara;R.R. Karthieka;B.S. Ajith Kumar;M. Prabhaharan
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2190-2194
    • /
    • 2024
  • The study investigates the dose-dependent direct X-ray sensing characteristics of Brucinium benzilate (BB) and N-acetylglycine (NAG) organic crystals. BB and NAG were prepared as a slurry and deposited as a thick film on a patterned metal electrode. The X-ray induced photocurrent response was examined for various exposure doses using an intraoral pulsed 70 keV X-ray machine connected to a source meter. Subsequently, the morphological properties and thickness of the thick films were analyzed using scanning electron microscopy (SEM). At a photon energy of 70 keV, the attenuation coefficient values for NAG and BB crystals were determined to be approximately 0.181 and 0.178 cm2/g, respectively. The X-ray stopping power of the crystals was measured using a suniray-2 X-ray imaging system. To evaluate the responsiveness of the sensors, the photocurrent sensitivity and noise equivalent dose rate (NED) were calculated for both thick films. The findings demonstrated a noteworthy capability of sensing low doses (mGy), thereby suggesting the potential application of these organic materials in X-ray sensor development.

방사선 노출에 따른 3T APS 성능 감소와 몬테카를로 시뮬레이션을 통한 픽셀 내부 결함의 비교분석 (A Comparison between the Performance Degradation of 3T APS due to Radiation Exposure and the Expected Internal Damage via Monte-Carlo Simulation)

  • 김기윤;김명수;임경택;이은중;김찬규;박종환;조규성
    • 방사선산업학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2015
  • The trend of x-ray image sensor has been evolved from an amorphous silicon sensor to a crystal silicon sensor. A crystal silicon X-ray sensor, meaning a X-ray CIS (CMOS image sensor), is consisted of three transistors (Trs), i.e., a Reset Transistor, a Source Follower and a Select Transistor, and a photodiode. They are highly sensitive to radiation exposure. As the frequency of exposure to radiation increases, the quality of the imaging device dramatically decreases. The most well known effects of a X-ray CIS due to the radiation damage are increments in the reset voltage and dark currents. In this study, a pixel array of a X-ray CIS was made of $20{\times}20pixels$ and this pixel array was exposed to a high radiation dose. The radiation source was Co-60 and the total radiation dose was increased from 1 to 9 kGy with a step of 1 kGy. We irradiated the small pixel array to get the increments data of the reset voltage and the dark currents. Also, we simulated the radiation effects of the pixel by MCNP (Monte Carlo N-Particle) simulation. From the comparison of actual data and simulation data, the most affected location could be determined and the cause of the increments of the reset voltage and dark current could be found.

Impact of 0.35 T Magnetic Field on Dose Calculation for Non-small Cell Lung Cancer Stereotactic Radiotherapy Plans

  • Jaeman Son;Sung Young Lee;Chang Heon Choi;Jong Min Park;Jung-in Kim
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.117-123
    • /
    • 2023
  • Background: We investigated the impact of 0.35 T magnetic field on dose calculation for non-small cell lung cancer (NSCLC) stereotactic ablative radiotherapy (SABR) in the ViewRay system (ViewRay Inc.), which features a simultaneous use of magnetic resonance imaging (MRI) to guide radiotherapy for an improved targeting of tumors. Materials and Methods: Here, we present a comprehensive analysis of the effects induced by the 0.35 T magnetic field on various characteristics of SABR plans including the plan qualities and dose calculation for the planning target volume, organs at risk, and outer/inner shells. Therefore, two SABR plans were set up, one with a 0.35 T magnetic field applied during radiotherapy and another in the absence of the field. The dosimetric parameters were calculated in both cases, and the plan quality indices were evaluated using a Monte Carlo algorithm based on a treatment planning system. Results and Discussion: Our findings showed no significant impact on dose calculation under the 0.35 T magnetic field for all analyzed parameters. Nonetheless, a significant enhancement in the dose was calculated on the skin surrounding the tumor when the 0.35 T magnetic field was applied during the radiotherapy. This was attributed to the electron return effect, which results from the deviation of the electrons ejected from tissues upon radiation due to Lorentz forces. These returned electrons re-enter the tissues, causing a local dose increase in the calculated dose. Conclusion: The present study highlights the impact of the 0.35 T magnetic field used for MRI in the ViewRay system for NSCLC SABR treatment, especially on the skin surrounding the tumors.

단순 골반 골절된 장루술 환자 치험 1례 (A Case Report on Simple Pelvic Fracture with Ostomy)

  • 안훈모;김준철;나삼식
    • 대한의료기공학회지
    • /
    • 제13권1호
    • /
    • pp.1-18
    • /
    • 2013
  • Objective : The objective of this study is to report the effectiveness of conservative treatment on simple pelvic fracture with ostomy. Methods : A female patient 65 years old with ostomy, who were diagnosed as simple pelvic fracture by X-ray, were treated with conservative treatment by herbal medication with acupuncture and physical therapy. We evaluated the effectiveness by checking X-ray, Digital Infrared Thermal Imaging(D.I.T.I.). Results : The symptoms of the patient got improved and X-ray showed the fracture were healing. Conclusions : Conservative korean medical treatment can be effectively used for a patient with simple pelvic fracture and ostomy.

비정질 실리콘 디지털 방사선 촬영기의 개발 (Development of Amorphous Silicon Based Digital Radiography System)

  • 이형구;서태석;최보영;신경섭;김홍권
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.94-95
    • /
    • 1998
  • We developed a digital x-ray medical imaging system using commercially available amorphous silicon image sensor plate. The image readout could be accomplished within 3.5 sec after radiation exposure and be displayed on a monitor through computer interface. This system needs not the conventional x-ray films and film processors, and also provides digital radiographic images. This system is the fastest digital radiography system developed so far, and expected to replace many of the conventional x-ray film systems or digital radiography systems.

  • PDF