• 제목/요약/키워드: T-plate

검색결과 1,307건 처리시간 0.028초

IGRINS First Light Instrumental Performance

  • Park, Chan;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Park, Byeong-Gon;T., Daniel
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.52.2-52.2
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is an unprecedentedly minimized infrared cross-dispersed echelle spectrograph with a high-resolution and high-sensitivity optical performance. A silicon immersion grating features the instrument for the first time in this field. IGRINS will cover the entire portion of the wavelength range between 1.45 and $2.45{\mu}m$ accessible from the ground in a single exposure with spectral resolution of 40,000. Individual volume phase holographic (VPH) gratings serve as cross-dispersing elements for separate spectrograph arms covering the H and K bands. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{\prime\prime}{\times}15^{\prime\prime}$. IGRINS has a $0.27^{\prime\prime}$ pixel-1 plate scale on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized rectangular vacuum chamber. The fabrication and assembly of the optical and mechanical hardware components were completed in 2013. In this presentation, we describe the major design characteristics of the instrument and the early performance estimated from the first light commissioning at the McDonald Observatory.

  • PDF

종골 관절내 골절의 수술적 치료 후 임상 결과 -전산화 단층 촬영에 따른 분류 및 관혈적 정복 및 내고정 치료- (Result of Surgical Treatment of Intra-Articular Fractures of the Calcaneus - Based on CT Classification and Open Reduction and Internal Fixation -)

  • 김의순;서현모;이규민;최훈휘;문명상;이만희;최원태
    • 대한족부족관절학회지
    • /
    • 제7권2호
    • /
    • pp.238-249
    • /
    • 2003
  • Purpose: To report the clinical result of the intraarticular calcaneus fracture after open reduction and internal fixation with plate by lateral approach. Materials and Methods: Thirty-six calcaneal fractures of 33 patients(29 men and 4 women) were treated by open reduction and internal fixation using an lateral approach from March, 1997 to May, 2002 and were followed more than one year. The autogenous iliac bone graft was done in 2 cases but the others didn't. Radiographically B?hler angle and Gissane angle on simple lateral radiograph were measured and in the 15 cases, the step-off(gap) of posterior facet joint on post-operative CT images were followed. The Salama method was used for evaluation of clinical results. Results: According to Sanders classification, 19 cases of the 36 cases were classified as type II. Type III fracture were found in 12 cases and type IV in 5 cases. The following results were obtained: twenty-two cases(61.1%) out of 36 cases were estimated as good or excellent. The good results or more were obtained in 15 cases(78.9%) in type II and 7 cases(58.3%) in type ill, but no case in type IV. B?hler angles were improved from preoperative average 1.6?to postoperative average 23.4?, Gissane angle was improved from preoperative 107.2?to postoperative 122.8?, respectively. Among 36 cases, Computed tomography was carried out in 15 cases. The postoperative step-off (gap) of posterior facet joint on computed tomography was filled with cancellous bone. Satifactory results was obtained in 7 cases with 2mm gap or less and in 6 cases of 2-5mm. There were no satifactory results in 2 cases with 5mm gap or more. Conclusion: Open reduction and internal fixation for intra-articular fracture of calcaneus was thought to be a good treatment modality. It is thought that the lateral approach is one of the good one for surgical treatment, and that accurate reduction of the posterior facet, acceptable recovery of B?hler angle are more important to obtain best results.

  • PDF

$Ti:LiNbO_3$ 도파로 제작을 위한 열처리 과정 동안 강유전 도메인 특성에 미치는 영향 (Ferroelectric domain inversion in $LiNbO_3$ crystal plate during heat treatment for Ti in-diffusion)

  • 양우석;이형만;권순우;김우경;이한영;윤대호
    • 한국결정성장학회지
    • /
    • 제15권3호
    • /
    • pp.124-127
    • /
    • 2005
  • [ $Ti:LiNbO_3$ ], 광도파로 제작을 위해 큐리온도$(T_c)$ 아래에서 백금박스 내에서 알곤 과 산소 분위기 내에서 열처리 과정 동안 기판 표면의 강유전 도메인 특성 변화를 관찰하였다. 열처리 된 $LiNbO_3$ 기판의 +Z면의 경우 전체적으로 약 $1.6{\mu}m$ 두께로 도메인 반전이 이루어 졌으며, 표면에서 etch hillock이 관찰되었다. $LiNbO_3$ 결정 표면의 Li 이온이 외부로 확산 되는 영향을 감소시킬 수 있는 환경에 있는 기판 면에서 하나의 도메인이 관찰되었으며, 이때 결정 표면에서의 식각특성, 결정성 및 양이온 분포변화에 관하여 X-선 회절, AFM 및 SIMS를 이용하여 분석하였다.

치과용 아크릴릭 레진의 방사선 불투과도에 관한 연구 - 황산바륨과 요오드 화합물 첨가 - (THE EFFECTS OF BARIUM SULFATE AND IODIDE COMPOUND ON THE CHARACTERISTICS OF DENTAL ACRYLIC RESINS)

  • 이용근;이건일;정성우
    • 치과방사선
    • /
    • 제26권2호
    • /
    • pp.133-145
    • /
    • 1996
  • Aspirating or swallowing foreign bodies is a common occurrence. If they are wholly or partly radiopaque, their localization in and progress through the gastrointestinal tract can be more effective. Of the dental origin foreign materials swallowed, the most common things are fragments of anterior maxillary partial denture. But the radiopacity of denture base resins is not sufficient to determine the location of the objects. The purpose of this study was to develop a radiopaque dental acrylic resin, which has clinically detectible radiopacity with minimal change of mechanical properties and color. The radiopacity, color change(CIE 6..E) and microhardness of acrylic resins were determined after mixing barium sulfate or iodide compound. Thermocycling course was conducted to determine the change of characteristic of resins after using for a long time in the mouth. Five or ten percent of barium sulfate to total weight of cured material was mixed with heat curing dental acrylic resin or chemically curing orthodontic resin. In the case of iodide compound, the mixing ratio was two or three percent. After mixing the high radiopaque materials, resin was cured to 20×20×2 mm plate, polished with #600 sand paper and finally polished with Microcloth(Buehler). The specimens were thermocycled in 5 and 55 t distilled water for 2,000 times, and the measurement of radiopacity, color and Vickers hardness was repeated every 500 times thcrmocycling. The radiopacity of specimens on the X -ray films was measured with densitometer(X-rite). The color change was detennined with differential colorimeter(Model TC-6FX, Tokyo Denshoku), and the Vickers hardness number was measured with microhardness tester(Mitsuzawa). The following results were obtained : 1. All the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, had combined effect on the radiopacity of the dental acrylic resins(p<0.0l). 2. The two variables, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of the dental acrylic resins(p<0.01). But the kinds of acrylic resins did not influence on the color change of mixed dental acrylic resins(p>0.05). 3. Each of the three variables, the kinds of acrylic resins, the mixing or the kinds of high radiopaque materials and thermocycling, influenced on the radiopacity of dental acrylic resins(p<0.0l). 4. The high radiopaque materials used in this study did not yield clinically usable radiopacity, and the color change was great after mixing those materials.

  • PDF

Antimicrobial Active Substances from Entomopathogenic Fungi (Various Applications of Entomopathogenic Fungi)

  • Shin, Tae Young;Woo, Soo Dong;Kim, Jeong Jun
    • 한국균학회소식:학술대회논문집
    • /
    • 한국균학회 2016년도 춘계학술대회 및 임시총회
    • /
    • pp.13-13
    • /
    • 2016
  • Insects constitute the largest and most diverse group of animals in the world. They also serve as the hosts or nutrient sources for an immense assemblage of pathogens, parasites, and predators. More than 700 fungal species from 100 genera have adopted an entomopathogenic lifestyle. Although entomopathogenic fungi were studied as only biocontrol agents against a variety of pests in various countries, it has been recently focused their additional roles in nature. They are antagonists to/against plant pathogens, endophytes, and possibly even plant growth promoting agents. The potential antimicrobial effect against fungal plant pathogens by an isolate of entomopathogenic fungi including Beauveria bassiana, Lecanicillium spp., and Isaria fumosorosea have been reported since late 1990s, but wasn't reported pathogenicity of the isolate against pests. Later, a Canadian Lecanicillium sp. isolate and L. longisporium isolated from Vertalec$^{(R)}$ showed simultaneous control effect against both aphid and cucumber powder mildew. Therefore, the antimicrobial activities of 342 fungi isolates collected from various regions and conditions in Korea were evaluated against plant pathogenic fungus Botrytis cinerea using dual culture technique on agar plate. As a result, 186 isolates (54.4%) shown the antifungal activity against B. cinerea. The culture filtrates of selected fungi completely suppressed the growth of the microorganisms, indicating that suppression was due to the presence of antimicrobial substances in the culture filtrate. Mode of action of these fungi against insect involves the attachment of conidia to the insect cuticle, followed by germination, cuticle penetration, and internal dissemination throughout the insect. During infection process, secreted enzymes, proteinous toxins, and/or secondary metabolites secreted by entomopathogenic fungi can be used to overcome the host immune system, modify host behavior, and defend host resources. Recently, secondary metabolites isolated from entomopathogenic fungi have been reported as potential bioactive substances. Generally, most of bioactive substances produced by entomopathogenic fungi have reported low molecular weight (lower than 1,000 g/mol) as peptide and, in contrast the high molecular weight fungal bioactive substances are rare. Most substances based on entomopathogenic fungi were shown antimicrobial activity with narrow control ranges. In our study we analyzed the antimicrobial substances having antagonistic effects to B. cinerea. Antimicrobial substances in our fungal culture filtrates showed high thermostability, high stability to proteolytic enzymes, and hydrophilicity and their molecular weights were differed from substance. In conclusion, entomopathogenic fungi showed pathogenicity against insect pests and culture filtrate of the fungi also shown to antimicrobial activity. In the future, we can use the entomopathogenic fungi and its secondary metabolites to control both insect pest control and plant pathogenic fungi simultaneously.

  • PDF

느타리버섯 균상재배 중 배지에서 분리한 미생물의 특성 (Characteristics of microorganism isolated from Cotton Waste Media for the Oyster Mushroom Cultivation)

  • 이찬중;전창성;정종천;오진아;한혜수;엄나나
    • 한국균학회지
    • /
    • 제38권2호
    • /
    • pp.120-124
    • /
    • 2010
  • 본 시험은 재배과정 중 균상배지에서 분리한 세균들의 특성을 조사하여 버섯균의 생육 및 병원균과의 연관관계를 밝히고자 하였다. 정상적으로 버섯을 수확한 농가의 경우 버섯생육초기에 분리한 세균일수록 버섯균주에 대해 저해정도가 감소하였으나, 생육이 진행될수록 저해균의 수가 증가하였으나, 버섯 수확에 실패한 농가의 경우 반대의 경향을 보였다. 또한 합성배지에 분리세균을 도말한 후 느타리버섯 균의 생육을 조사한 결과 정상적 농가의 경우 살균 직후 보다 생육이 진행될수록 저해균의 수가 증가하였지만, 실패한 농가는 오히려 반대의 경향을 보였다. 그러나 톱밥배지에서는 버섯생육초기보다 후기에 분리한 세균이 저해하는 정도가 오히려 낮았다. 또한 이들 분리 세균은 분비성 물질을 통해서 버섯균의 생육과 증식에 영향을 미쳤다. 분리 미생물 중 세균성갈반병의 원인균인 Pseudomonas tolaasii을 강하게 억제하는 미생물은 거의 없었으며 소수의 균주에서 약한 길항력을 보였다. 그러나 세균성갈색무늬병을 일으키는 P. agarici에 대해서는 강한 억제력을 보이는 균주가 많이 존재하였으며, 푸른곰팡이병의 원인균인 Trichoderma harzianum을 강하게 억제하는 미생물도 배지내에 거의 존재하지 않았다. 이와 같이 배지내에는 다양한 미생물이 존재하고 이들 다양한 미생물과 버섯균의 상호작용에 대한 면밀한 연구가 이루어진다면 느타리버섯 재배과정 중 발생하는 다양한 문제점을 해결할 수 있는 좋은 방법이 될 수 있을것으로 생각된다.

Gibbs 선행치를 사용한 배열된부분집합 기대값최대화 방출단층영상 재구성방법에 관한 연구 (A Study on the Ordered Subsets Expectation Maximization Reconstruction Method Using Gibbs Priors for Emission Computed Tomography)

  • 임기천;최용;김종호;이수진;우상근;서현관;이경현;감상흔;최연성;박장춘;김병태
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권5호
    • /
    • pp.441-448
    • /
    • 2000
  • 방출단층영상 재구성을 위한 최대우도 기대값최대화(maximum likelihood expectation maximization, MLEM) 방법은 영상 획득과정을 통계학적으로 모델링하여 영상을 재구성한다. MLEM은 일반적으로 사용하여 여과후역투사(filtered backprojection)방법에 비해 많은 장점을 가지고 있으나 반복횟수 증가에 따른 발산과 재구성 시간이 오래 걸리는 단점을 가지고 있다. 이 논문에서는 이러한 단점을 보완하기 위해 계산시간을 현저히 단축시킨 배열된부분집합 기대값최대화(ordered subsets expectation maximization. OSEM)에 Gibbs 선행치인 membrance (MM) 또는 thin plate(TP)을 첨가한 OSEM-MAP (maximum a posteriori)을 구현함으로써 알고리즘의 안정성 및 재구성된 영상의 질을 향상시키고자 g나다. 실험에서 알고리즘의 수렴시간을 가속화하기 위해 투사 데이터를 16개의 부분집합으로 분할하여 반복연산을 수행하였으며, 알고리즘의 성능을 비교하기 위해 소프트웨어 모형(원숭이 뇌 자가방사선, 수학적심장흉부)을 사용한 영상재구성 결과를 제곱오차로 비교하였다. 또한 알고리즘의 사용 가능성을 평가하기 위해 물리모형을 사용하여 PET 기기로부터 획득한 실제 투사 데이터를 사용하였다.

  • PDF

Petrogenesis of Mesozoic granites at Garorim Bay, South Korea: evidence for an exotic block within the southwestern Gyeonggi massif?

  • Kim, Ji In;Choi, Sung Hi;Yi, Keewook
    • Geosciences Journal
    • /
    • 제23권1호
    • /
    • pp.1-20
    • /
    • 2019
  • We present data from the Mesozoic Keumkang, Palbong, and Baekhwa granites in Garorim Bay, in the southwestern part of the Gyeonggi massif, South Korea. Using major and trace element concentrations, Sr-Nd-Pb isotopic compositions, and sensitive high-resolution ion microprobe (SHRIMP) zircon U-Pb ages, we aim to constrain the petrogenesis of the granites and explain their origin within a broader regional geological context. SHRIMP U-Pb zircon ages of $232.8{\pm}3.2$, $175.9{\pm}1.2$, and $176.8{\pm}9.8$ Ma were obtained from the Keumkang, Palbong and Baekhwa granites, respectively. The Late Triassic Keumkang granites belong to the shoshonite series and show an overall enrichment in large ion lithophile elements (LILE), a depletion in high field strength elements (HFSE) relative to primitive mantle, compared with neighboring elements in the primitive mantle-normalized incompatible trace element diagram with notable high Ba and Sr contents, and negligible Eu anomalies. The Keumkang granites are typified by highly radiogenic Sr and unradiogenic Nd and Pb isotopic compositions: $(^{87}Sr/^{86}Sr)_i=0.70931-0.70959$, $(^{143}Nd/^{144}Nd)_i=0.511472-0.511484$ [$({\varepsilon}_{Nd})_i=-17.0$ to -16.7], and $(^{206}Pb/^{204}Pb)=17.26-17.27$. The Middle Jurassic Palbong and Baekhwa granites belong to the medium- to high-K calc-alkaline series, and show LILE enrichment and HFSE depletion similar to the Keumkang granites, but exhibit significant negative anomalies in Ba, Sr, and Eu. Furthermore, they have elevated Y and Yb contents at any given $SiO_2$ content compared with other Jurassic granitoids from the Gyeonggi massif. The Palbong and Baekhwa granites have slightly less radiogenic Sr and more radiogenic Nd and Pb isotopic compositions [$(^{87}Sr/^{86}Sr)_i=0.70396-0.70908$, $(^{143}Nd/^{144}Nd)_i=0.511622-0.511660$, $({\varepsilon}_{Nd})_i=-15.4$ to -14.7, $(^{206}Pb/^{204}Pb)=17.56-17.76$] relative to the Keumkang granites. The Keumkang granites are considered to have formed in a post-collisional environment following the Permo-Triassic Songrim orogeny that records continent-continent collision between the North and South China blocks, and may have formed by fractional crystallization of metasomatized lithospheric mantle-derived mafic melts. The Palbong and Baekhwa granites may have been produced from a gabbroic assemblage at pressures of less than ~15 kbar, associated with subduction of the paleo-Pacific (Izanagi) plate at the Eurasian continental margin. Elevated ${\varepsilon}_{Nd}(t)$ values in the granitoids from the southwestern part of the Gyeonggi massif relative to those of the central and northern parts, together with the comparatively shallow depth of origin, imply the presence of an exotic block in the Korean lithosphere.

부여(扶餘) 능산리고분군(陵山里古墳群) 성격(性格)에 대한 재고(再考) (Revisiting of ancient tombs in Neungsan-ri, Buyeo)

  • 김규운;양숙자
    • 헤리티지:역사와 과학
    • /
    • 제49권2호
    • /
    • pp.104-121
    • /
    • 2016
  • 능산리고분군은 일제강점기에 몇 차례 조사되었으나 아직까지 그 전체적인 양상을 이해하기에는 자료가 턱없이 부족하다. 또한 기왕의 조사자료에 대한 분석 자체도 부족하다. 따라서 능산리고분군이 어떻게 조사되었고, 보존되어 왔는지에 대한 검토를 통해 능산리고분군을 새롭게 이해하고 접근할 필요성이 있음을 강조하였다. 능산리고분군의 일련번호는 일제강점기부터 지금까지 확실한 기준이 제시되지 않은 채 자의적으로 부여해 왔다. 이는 당시 조사과정에서 일련번호가 어떻게 변하였는지에 대한 검토가 없었기 때문으로 보았다. 그리고 능산리고분군은 현재 정비되어 있는 7기로 구성된 것이 아니라 이미 일제강점기에 서쪽부터 3+4+7+5기로 구성되어 있음을 확인하였고, 현 (現)8호분의 성과를 더하면 적어도 20기로 구성된 고분군임을 제시하였다. 또한 동고분군의 경우, 현실의 규모, 고우야마키로 제작한 목관에 옻칠을 한 공정까지 중앙의 6기와 비교해도 크게 차이가 없는 것으로 보면서 6기만을 왕릉군으로 설정해 온 기왕의 인식에 변화가 필요함을 강조하였다. 궁극적으로 현재 정비되어 있는 능산리고분군은 일제강점기에 이미 정비가 완료되면서 원래 가지고 있던 정보를 하나도 표현하고 있지 못함을 지적하였다. 현실로 진입하는 입구시설, 호석을 덮어버리고 고대하게 과장된 봉분이 그러하고, 심지어 주위에 다른 고분들이 분명 있음에도 불구하고 지금까지 제대로 된 지표조사 한번 없었던 문제점을 부각시키면서 능산리고분군에 대한 전반적인 조사가 필요하다고 결론지었다.

In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position

  • Dae-Sung Kim;So-Hyung Park;Jong-Ju Ahn;Chang-Mo Jeong;Mi-Jung Yun;Jung-Bo Huh;So-Hyoun Lee
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권5호
    • /
    • pp.271-280
    • /
    • 2023
  • PURPOSE. This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS. Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS. Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION. In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.