• Title/Summary/Keyword: T-junction

Search Result 398, Processing Time 0.026 seconds

Immunohistochemical study on endocrine cells of the thymus of duck(Anas platyrhynchos platyrhyncos, Linne) (청둥오리의 가슴샘 내분비세포에 대한 면역조직화학적 연구)

  • Kim, Jeong-mi;Lee, Jae-hyun;Ku, Sae-kwang;Lee, Hyeung-sik
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.2
    • /
    • pp.246-257
    • /
    • 1998
  • Endocrine cells in the thymus of duck(Anas platyrhynchos platyrhyncos, Linne) were studied immunohistochemically from 23 days of incubation to 32 weeks of age. Somatostatin-, growth hormone(GH)-, gastrin/cholecystokinin(Gas/CCK)-, polypeptide YY(PYY)-, S-100 protein(S-100 P)-, dopamine-, serotonin(5-HT)-, and bovine chromogranin (BCG)-immunoreactive cells were detected in the duck thymus by the PAP techniques. These immunoreactive cells were observed in the medulla and in the juxtacortical medulla. No immunoreactivity of calcitonin and bovine pancreatic polypeptide(BPP) antiserum were observed. The argyrophil cells by Grimelius techniques were observed from 23 days of incubation to 32 weeks of age and peaked in 5 weeks of age. In the early develpmental stage, the argyrophil cells were distributed only in the medulla, while these cells were distributed mainly in the medulla and a few cells were distributed in the corticomedullary junction from 3 weeks of age. These immunoreactive cells were generally round, oval and elliptical and occasionally spindle, polygonal and polymorphous with the long cytopslasmic processes in shape. The present study suggests that the intrathymic endocrine cells may associate with the functional maturation of T-lymphocytes on the establishment of immunity. The further study will be needed to elucidate the function of these thymic endocrine cells.

  • PDF

Skeletal and dentoalveolar changes after miniscrew-assisted rapid palatal expansion in young adults: A cone-beam computed tomography study

  • Park, Jung Jin;Park, Young-Chel;Lee, Kee-Joon;Cha, Jung-Yul;Tahk, Ji Hyun;Choi, Yoon Jeong
    • The korean journal of orthodontics
    • /
    • v.47 no.2
    • /
    • pp.77-86
    • /
    • 2017
  • Objective: The aim of this study was to evaluate the skeletal and dentoalveolar changes after miniscrew-assisted rapid palatal expansion (MARPE) in young adults by cone-beam computed tomography (CBCT). Methods: This retrospective study included 14 patients (mean age, 20.1 years; range, 16-26 years) with maxillary transverse deficiency treated with MARPE. Skeletal and dentoalveolar changes were evaluated using CBCT images acquired before and after expansion. Statistical analyses were performed using paired t-test or Wilcoxon signed-rank test according to normality of the data. Results: The midpalatal suture was separated, and the maxilla exhibited statistically significant lateral movement (p < 0.05) after MARPE. Some of the landmarks had shifted forwards or upwards by a clinically irrelevant distance of less than 1 mm. The amount of expansion decreased in the superior direction, with values of 5.5, 3.2, 2.0, and 0.8 mm at the crown, cementoenamel junction, maxillary basal bone, and zygomatic arch levels, respectively (p < 0.05). The buccal bone thickness and height of the alveolar crest had decreased by 0.6-1.1 mm and 1.7-2.2 mm, respectively, with the premolars and molars exhibiting buccal tipping of $1.1^{\circ}-2.9^{\circ}$. Conclusions: Our results indicate that MARPE is an effective method for the correction of maxillary transverse deficiency without surgery in young adults.

Root surface areas of maxillary permanent teeth in anterior normal overbite and anterior open bite assessed using cone-beam computed tomography

  • Suteerapongpun, Piyadanai;Sirabanchongkran, Supassara;Wattanachai, Tanapan;Sriwilas, Patiyut;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.241-246
    • /
    • 2017
  • Purpose: The aim of this study was to compare the root surface areas of the maxillary permanent teeth in Thai patients exhibiting anterior normal overbite and in those exhibiting anterior open bite, using cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of maxillary permanent teeth from 15 patients with anterior normal overbite and 18 patients with anterior open bite were selected. Three-dimensional tooth models were constructed using Mimics Research version 17.0. The cementoenamel junction was marked manually. The root surface area was calculated automatically by 3-Matic Research version 9.0. The root surface areas of each tooth type from both types of bite were compared using the independent t-test (P<.05). The intraclass correlation coefficient was used to assess intraobserver reliability. Results: The mean root surface areas of the maxillary central and lateral incisors in individuals with anterior open bite were significantly less than those in those with normal bite. The mean root surface area of the maxillary second premolar in individuals with anterior open bite was significantly greater than in those with normal bite. Conclusion: Anterior open-bite malocclusion might affect the root surface area, so orthodontic force magnitudes should be carefully determined.

EFFECT OF TYPE AND CEMENTATION METHOD OF POST-CORE ON MICROLEAKAGE (포스트코어의 종류와 접착방법이 미세누출에 미치는 영향)

  • Yun Myoung-Jae;Lee Sun-Hyung;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.225-233
    • /
    • 1994
  • The restorations of the severely damaged teeth by post core have been increased with the developement of endodontic procedures. But high failure rates of these procedures being reported, various restorative modifications were induced for successful treatments. Cast post-core and prefabricated post with core buildups are choice of treatment. The main causes of failure of the restorations are the fracture of post and core, root fracture, and recurrent caries due to microleakage. Recently, the acid etching technique and the use of dentin bonding agent at tooth surface to reduce the possible microleakage at the tooth-restoration interfaces were introduced. The object of this study was to measure and compare the microleakage by the types and cementation methods of post-core. For this study, forty extracted human anterior teeth were selected for specimen. After cleansing and routine endodontic procedures, anatomic crowns of each specimen were removed at the level of 2mm above the cementoenamel junction. Canals were preparated for post insertion and specimens were divided into four groups randomly. Post-cores were fabricated according to method for each group. Microleakage was measured by length of dye penetration at the tooth-restoration interfaces with measuring microscope at 50 magnification. Oneway ANOVA and t-test were performed for statistical analysis of resulting data. The following results were obtained from this study. 1. There wert significant statistical differences in degree of microleakage between each group (p<0.01). 2. Cast post-core cemented with ZPC (Group I) showed the most severe microleakage pattern$(1.5547{\pm}0.0872mm)$, and cast post-core cemented with adhesive resin cement after tooth surface treatment with dentin bonding agent (Group II) showed the least microleakage $(0.1497{\pm}0.0872mm)$. 3. Group IV revealed less dye penetrations than group III, but no statistical significance was seen between two groups.

  • PDF

Magnetic Sensor-Based Detection of Picoliter Volumes of Magnetic Nanoparticle Droplets in a Microfluidic Chip

  • Jeong, Ilgyo;Eu, Young-Jae;Kim, Kun Woo;Hu, XingHao;Sinha, Brajalal;Kim, CheolGi
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2012
  • We have designed, fabricated and tested an integrated microfluidic chip with a Planar Hall Effect (PHE) sensor. The sensor was constructed by sequentially sputtering Ta/NiFe/Cu/NiFe/IrMn/Ta onto glass. The microfluidic channel was fabricated with poly(dimethylsiloxane) (PDMS) using soft lithography. Magnetic nanoparticles suspended in hexadecane were used as ferrofluid, of which the saturation magnetisation was 3.4 emu/cc. Droplets of ferrofluid were generated in a T-junction of a microfluidic channel after hydrophilic modification of the PDMS. The size and interval of the droplets were regulated by pressure on the ferrofluid channel inlet. The PHE sensor detected the flowing droplets of ferrofluid, as expected from simulation results. The shape of the signal was dependent on both the distance of the magnetic droplet from the sensor and the droplet length. The sensor was able to detect a magnetic moment of $2{\times}10^{-10}$ emu at a distance of 10 ${\mu}m$. This study provides an enhanced understanding of the magnetic parameters of ferrofluid in a microfluidic channel using a PHE sensor and will be used for a sample inlet module inside of integrated magnetic lab-on-a-chip systems for the analysis of biomolecules.

Effect of GLUMA desensitizer on the retention of full metal crowns cemented with Rely X U200 self-adhesive cement

  • Lawaf, Shirin;Jalalian, Ezatallah;Roshan, Roshanak;Azizi, Arash
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.404-410
    • /
    • 2016
  • PURPOSE. Considering the importance of retention in the success and long-term clinical service of fixed partial dentures (FPDs) as well as the existing controversy regarding the effect of GLUMA desensitizer on the retention of full metal crowns cemented with RelyX U200 self-adhesive cement, this study aimed to assess the effect of GLUMA desensitizer on the retention of full metal crowns cemented using RelyX U200. MATERIALS AND METHODS. In this experimental study, 20 sound human premolars were prepared; a 0.5 mm chamfer finish line was prepared above the cementoenamel junction. The teeth were randomly assigned to two groups: a desensitizer group (n = 10, treated with GLUMA desensitizer) and a control (n = 10, no surface treatment). Full metal crowns were fabricated of base metal alloy and had a ring. All crowns were cemented with RelyX U200 and subjected to retention test by using a universal testing machine. The data were analyzed using SPSS version 20 and independent t-test. RESULTS. The mean tensile bond strength was significantly higher in the GLUMA desensitizer group ($230.63{\pm}63.8N$) compared to the control group ($164.45{\pm}39.3N$) ($P{\leq}.012$). CONCLUSION. GLUMA desensitizer increases the tensile bond strength of RelyX U200 self-adhesive cement to dentin.

Application of Miniature Heat Pipe for Notebook PC Cooling (노트북 PC CPU 냉각용 소형 히트파이프 Packaging 연구)

  • Moon, Seok-Hwan;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.799-803
    • /
    • 2001
  • Miniature heat pipe(MHP) with woven-wired wick was used to cool the CPU of a notebook PC. The pipe with circular cross-section was pressed and bent for packaging the MHP into a notebook PC with very limited compact packaging space. A cross-sectional area of the pipe is reduced about 30% as the MHP with 4mm diameter is pressed to 2mm thickness. In the present study a performance test has been performed in order to review varying of operating performance according to pressed thickness variation and heat dissipation capacity of MHP cooling module that is packaged on a notebook PC. New wick type was considered for overcoming low heat transfer limit when MHP is pressed to thin-plate. The limiting thickness or pressing is shown to be within the range of 2mm∼2.5mm through the performance test with varying the pressing thickness. When the wall thickness of 0.4mm is reduced to 0.25mm for minimizing conductive thermal resistance through the wall of heat pipe, heat transfer limit and thermal resistance of MHP were improved about 10%. In the meantime, it is shown that the thermal resistance and heat transfer limit for the MHP with central wick type are higher than those of MHP with existing wick types. The results of performance test for MHP cooling modules with woven-wired wick to cool a notebook PC shows the stability as cooling system since T(sub)j(Temperature of Processor Junction) satisfy a demand condition of 0∼100$\^{C}$ under 11.5W of CPU heat.

A Study on the Detection of Interfacial Defect to Boundary Surface in Semiconductor Package by Ultrasonic Signal Processing (초음파 신호처리에 의한 반도체 패키지의 접합경계면 결함 검출에 관한 연구)

  • Kim, Jae-Yeol;Hong, Won;Han, Jae-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.369-377
    • /
    • 1999
  • Recently, it is gradually raised necessity that thickness of thin film is measured accuracy and managed in industrial circles and medical world. Ultrasonic signal processing method is likely to become a very powerful method for NDE method of detection of microdefects and thickness measurement of thin film below the limit of ultrasonic distance resolution in the opaque materials, provides useful information that cannot be obtained by a conventional measuring system. In the present research. considering a thin film below the limit of ultrasonic distance resolution sandwiched between three substances as acoustical analysis model, demonstrated the usefulness of ultrasonic signal processing technique using information of ultrasonic frequency for NDE of measurements of thin film thickness. Accordingly, for the detection of delamination between the junction condition of boundary microdefect of thin film sandwiched between three substances the results from digital image processing.

  • PDF

Development of Detection Method of Unapproved Genetically Modified Potato (EH92-527-1) in Korea using Duplex Polymerase Chain Reaction (Duplex PCR을 이용한 국내 미승인 유전자변형 감자(EH92-527-1)의 검사법 개발)

  • Yoo, Myung-Ryul;Kim, Jae-Hwan;Yea, Mi-Chi;Kim, Hae-Yeong
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.156-160
    • /
    • 2013
  • A duplex polymerase chain reaction (PCR) method was developed to detect unapproved genetically modified (GM) potato (EH92-527-1) in Korea. The UDP-glucose pyrophosphorylase (UGP) gene was selected as an endogenous reference gene for potato and used to validate the specificity for 14 different crops. The primer pair EH92-F/R was designed to amplify the junction sequence between the genome and transgenic region introduced in GM potato. Its specificity was also validated using several different GM events. The detection limit of the duplex PCR method is approximately 0.05%. This duplex PCR method could be useful for monitoring cultivation of unauthorized GM potato in Korea.

Design and Fabrication of Heat Sink for Vehicle LED Headlamp Using Thermally-Conductive Plastics (열전도성 플라스틱을 적용한 자동차 LED 전조등 방열구조 연구)

  • Kim, Hyeong Jin;Lee, Dong Kyu;Park, Hyun Jung;Yang, Hoe Seok;Na, Pil Sun;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.544-549
    • /
    • 2015
  • Since LEDs (light emitting diodes) have many advantages as a light source in vehicle headlamp, such as good reliability, energy and space saving, and flexible headlamp design. On the other hand, the dependence of its performance and life on temperature have great influence on its practical use. In this study, design and fabrication of heat sink for vehicle LED headlamp were performed using thermally-conductive plastics. This study focused on the effective heat sink structure with limited space in the vehicle LED headlamp. We designed two different prototype of heat sink by thermal simulation using SolidWorks program, which had excellent temperature characteristics. The two different prototype of heat sink were fabricated by injection molding with thermally-conductive plastics. The results showed that LED $T_j$ (junction temperature) of sample B (model 1) and sample C (model 1, 2) was below then $165^{\circ}C$ when applying the thermally-conductive plastics in heat sink of vehicle LED headlamp.