• Title/Summary/Keyword: T-branch pipe

Search Result 23, Processing Time 0.03 seconds

A study on the Analyses of T-branch Pipe Forming using a Finite Element Method (유한요소법을 이용한 분기배관의 성형해석에 관한 연구)

  • Nam, Jun-Seok;Baek, Chang-Sun;Lim, Kwang-Kyu;SaKong, Seong-Ho;So, Soo-Hyun;Min, Kyung-Tak
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.98-105
    • /
    • 2007
  • On this study, we verified the possibilities of making T-branch pipe forming with carbon steel pipes and stainless steel pipes used by common FEM Program(ABAQUS) which are widely used in the fire protection and building construction fields. In this kind of T-branch pipe forming works, in principle, the seamless pipe is used. If the pipe has the seam, the forming face must be the opposite side of the seam. The forming works are carried out by a truncated cone shaped plug. We found that the face slope and the length of plug are the most important factor in pipe forming. Based on the results of forming analyses, we proposed the minimum height and thickness of pipe branch forming.

A Study on the Strength Analyses of T-Branch Pipes (분기배관의 강도해석에 관한 연구)

  • Nam, Jun-Seok;SaKong, Seong-Ho;Baek, Chang-Sun;Lim, Kwang-Kyu;Jeong, Jae-Han;Min, Kyung-Tak
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.36-41
    • /
    • 2007
  • In this study, we determined TBP(T-branched pipe) would be available in Fire Safety Codes with strength analyses. A common FEM Program(ABAQUS) was used as analyses method, and the analyses results were confirmed by strength tests of the T-branch pipe. As a result, we concluded that the T-branch pipe can be used safely. Further more, we determined what kind of stainless steel pipe can be used in place of carbon steel pipe(KS D 3507). The stainless steel pipe name Is KS D 3576(stainless steel pipe) 10S, so they can be applied for piping in fire protection system.

Limit Load Solutions for Piping Branch Junctions with local wall-thinning under Internal Pressure (감육이 존재하고 내압을 받는 T 분기관의 한계하중 평가식)

  • Ryu, Kang-Mook;Kim, Yun-Jae;Lee, Kuk-Hee;Park, Chi-Yong;Lee, Sung-Ho;Kim, Tae-Ryong
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1813-1817
    • /
    • 2007
  • The present work presents plastic limit load solutions for piping branch junctions with local wall-thinning, based on detailed three-dimensional (3-D) and small strain FE limit analyses using elastic-perfectly plastic materials. Three types of loading are considered; internal pressure, in-plane bending on the branch pipe and in-plane bending on the run pipe. The wall-tinning located on variable area of the piping branch junction is considered. A wide range of piping branch junction and wall-thinning geometries are considered. Comparison of the proposed solutions with FE results shows good agreement

  • PDF

Limit Loads for Piping Branch Junctions with Local Wall-thinning under Internal Pressure and In-plane Bending (감육이 존재하고 내압과 굽힘하중의 복합하중을 받는 T 분기관의 한계하중)

  • Han, Jae-Jun;Lee, Kuk-Hee;Kim, Yun-Jae;Lee, Sung-Ho;Park, Chi-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.299-304
    • /
    • 2008
  • This paper presents plastic limit loads of piping branch junctions with local wall thinning under combined pressure and in-plane bending, based on systematic three-dimensional finite element limit analyses using elastic-perfectly plastic materials. An ideal branch junction without weld or reinforcement around the intersection is considered with two locations of wall thinning; one in the run pipe, and the other in the branch pipe. Based on FE results, effects of thinning geometries on plastic limit moments are quantified and simple approximations of plastic limit loads are proposed.

  • PDF

Liquid entrainment through a large-scale inclined branch pipe on a horizontal main pipe

  • Gu, Ningxin;Shen, Geyu;Lu, Zhiyuan;Yang, Yuenan;Meng, Zhaoming;Ding, Ming
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1164-1171
    • /
    • 2020
  • T-junction structures play an important role in nuclear power plant systems. Research on liquid entrainment is mostly based on small-scale branch pipes (d/D ≤ 0.2) and attention paid to large-scale branch pipes (0.33 < d/D < 1) is insufficient. Accordingly, this study implements a series of experiments on the liquid entrainment of T-junction with different angles (32.2°,47.9°,62.3°,90°) through a large-scale branch (d/D = 0.675). The onset liquid entrainment is related to the gas phase Froude number Frg, the dimensionless gas chamber height hb/d and the branch pipe angle 𝜃. As Frg increases, hb/d also rises. With a constant hb/d, the onset liquid entrainment changes from droplets entrainment by the gas phase to that by the rising liquid film. The steady-state liquid entrainment is related to w3g, h/d and 𝜃. With constant w3g and h/d, the branch quality grows as the branch angle increases. With a certain h/d, the branch quality increases, as the w3g number increases.

Study of Thermal Stratification into Leaking Flow in the Nuclear Power Plant, Emergency Core Coolant System (원자로 비상 냉각재 누설에 의한 열성층의 비정상 특성에 관한 연구)

  • Han Seong-Min;Choi Yong-Don;Park Min-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.202-210
    • /
    • 2006
  • In the nuclear power plant, emergency core coolant system (ECCS) is furnished at reactor coolant system (RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can be occurred due to coolant leaking in the check valve. The thermal stratification produces excessive thormal stresses at the pipe wall so as to yield thermal fatigue crack (TFC) accident. In the present study, when the turbulence penetration occurs in the branch pipe, the maximum temperature differences of fluid at the pipe cross-sections of the T-branch with thermal stratification are examine.

Numerical Analysis Study of the Mixing Mechanism of Non-element Mixer (논 엘레멘트 믹서의 혼합 메커니즘에 관한 수치해석적 검토)

  • You, Sun Ho
    • Journal of ILASS-Korea
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Visualization of the mixing pattern in a non-element mixer was carried out using laser induced fluorescence(LIF) to evaluate characteristics of mixer consisting of the main flow pipe and branch flow pipes. The branch flows were injected periodically with the period $T_{in}$ normal to the main flow, and rhodamine B was mixed into the most upstream branch flow to visualize mixing pattern in the main flow pipe by LIF. The length of boundary line L of the LIF image was measured. In this study, a numerical analysis was performed to identify the mixing process of the non-element mixer, and the results were compared with experimental results. Each result was almost the same. When the number of branch flows is increased, the mixing pattern became complicated and was supposed to become chaotic. The length of boundary line L increased exponentially with an increase in the number of branch flows.

Analysis of Steady Flow by Main Pipe Arrangement in the Water Distributing Pipe Network (배수관망(配水管網)의 간선배치(幹線配置)에 따른 정류(定流)흐름 해석(解析))

  • Lee, Jeung Seok;Park, Ro Sam;Kim, Jee Hak;Choi, Yun Young;Ahn, Seung Seop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.73-82
    • /
    • 1999
  • In this study, the optimal analysis for pipe network is performed for the combined ideal pipe network system(CASE 1, CASE 2 and CASE 3) which is composed of 25 nodes, 41 elements, and 1 fixed nodal head with evaluating pressure variation distribution of main and branch in grid composed drainage pipe network. The linear analysis technique used as the analysis method in this study, the KYPIPE being used extensively as the linear technique to design and analysis of pipe network is applied. Firstly, in the analysis of pipe network, the CASE 2 and CASE 3 supply same thing(value) in the result of considering the total flow provided each pipeline, but in the general intension in the case of CASE 2, relative width of supply is more large than CASE 1 and CASE 3. Secondly, in the analysis technique of pipe network, CASE 3 is analysed largest as a result of comparing with same heads, and in the order of their size CASE 2 and CASE 1 were determined but the difference doesn't appear to be obvious. Thirdly, as the result of determining main factor, pressure in the design and analysis of net work. CASE 3 is from Node 3 to 25 than CASE 1 and CASE 2 and it is determined in the order of their size, CASE 2 and CASE 1. Finally, in this study, discharge flow distribution is evaluated in the same condition with 3-type CASE in the case of branch position for designing optimal composed drainage pipe network. As the result of that, branch pipe perform. Therefore, it is thought that the efficient and reasonable management of water supply and sewerage design will be possible if it give all our energies to study at the pipe system design in and out of country in the future.

  • PDF

Numerical Analysis of Thermal Stratification and Turbulence Penetration into Leaking Flow in a Circular Branch Piping (원형 T분기배관 내 누설유동의 열성층화와 난류침투에 관한 전산해석적 연구)

  • Han, Seong-Min;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1833-1838
    • /
    • 2003
  • In the nuclear power plant, emergency core coolant system(ECCS) is furnished at reactor coolant system(RCS) in order to cool down high temperature water in case of emergency. However, in this coolant system, thermal stratification phenomenon can be occurred due to coolant leaking in the check valve. The thermal stratification produces excessive thermal stresses at the pipe wall so as to yield thermal fatigue crack(TFC) accident. In the present study, when the turbulence penetration occurs in the branch piping, the maximum temperature differences of fluid at the pipe cross-sections of the T-branch with thermal stratification are examine

  • PDF