가방 휴대 방법이 보행 시 발바닥 접촉 양상에 미치는 영향 (The Influence of Various Carrying a Pack Methods during Walking on Parameters of Foot Contact)

  • 박수진;권유정;김민희;김진상
    • 대한물리치료과학회지
    • /
    • 제18권2호
    • /
    • pp.29-40
    • /
    • 2011
  • Purpose: The purpose of this study was to analyze the changes of parameters of foot contact by various carrying a pack methods during walking. Method: The subjects were consisted of normal forty four persons (males 30, females 14, mean age 23). The carrying a pack methods were classified into five conditions: carrying no bag(Con 1), carrying a backpack(Con 2), carrying a shoulder bag(Con 3), carrying a cross bag(Con 4), carrying a one-hand bag(Con 5). All subjects were participated in these five condition and measured foot pressure by F-scan system during walking. Then foot contact time, foot contact area, foot contact length and width were measured and analyzed. The repeated one-way analysis of variance (ANOVA) was used to get difference between conditions and independent t-test was used to get difference between left and right foot within condition. Result: In the comparison of parameters of foot, contact time, contact area and mid foot width were significantly different between conditions(p<.05), and in both foot contact time at condition 5 showed the most significant reduction(p<.05). In the comparison of parameters of foot between left and right foot within condition, every conditions were not significantly different(p>.05). Conclusion: In this study various carrying methods changed the parameters of foot contact and showed significant difference in some articles between carrying methods. However, asymmetric load of pack by carrying methods didn't affected symmetry of parameters of foot contact between left and right foot.

  • PDF

실시간 해킹, 탐지 및 추적관리 ICT 융합 보안 솔루션 시험평가 (Real-time hacking, detection and tracking ICT Convergence Security Solutions Test and Evaluation)

  • 김승범;양해술
    • 디지털융복합연구
    • /
    • 제13권4호
    • /
    • pp.235-246
    • /
    • 2015
  • 최근 다양한 불특정 다수의 해킹 및 반복되는 DDoS 사이버테러 공격을 이해하고, 그 해결책을 비로소 공격 기법에서 찾을 수 있었다. 공격자와 방어자, 공격 기법과 방어 기법의 접목이라는 자유로운 연구 방식은 항상 엉뚱함에서 가능성을 발견해가는 도전이라 할 수 있다. 본 논문에서는 "KWON-GA"라는 세계적인 화이트 해커들 개발진이 오랜 경험의 침투 및 진단을 통해, 공격이 최상의 방어라는 미명하에 방어의 목적으로 구현된 지식 정보 보안 솔루션을 고객이 운용 중인 시스템 환경에 맞추어 필요한 기술을 적용하는 커스터마이징 정책으로 맞춤 솔루션을 제공할 수 있으며, 독창적인 원천기술로 처리되어 탐색이 불가능하고 내부적으로 유출되는 경우에도 분석이 되지 않아 해커에게 분석되어 취약점을 노출하거나 해킹의 수단으로 악용되지 않는 ITC융합 보안 솔루션을 시험평가 하였다.

키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구 (A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness)

  • 박태현;정태곤;한동욱;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.

보행 시 부하 위치에 따른 족저압 중심(COP) 이동 분석 (The Analysis of Center of Pressure(COP) Displacement under Loading Position during Walking)

  • 박수진;김진상
    • 대한물리의학회지
    • /
    • 제5권1호
    • /
    • pp.15-24
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the effect of loading position on plantar center of pressure(COP) displacement when carrying a schoolbag during walking. Methods : Forty-four normal subjects were randomly assigned to five groups according to the method of carrying a schoolbag. The carrying a schoolbag methods were classified into five conditions: no bag (condition 1), a backpack (condition 2), a shoulder bag (condition 3), a cross bag (condition 4), a one-hand bag (condition 5). COP displacement such as anteroposterior distance and mediolateral distance of COP were measured with F-scan system. The repeated one-way analysis of variance (ANOVA) and independent t-test were used to confirm the statistical significance. Results : In the comparison of parameters of COP displacement between conditions, anteroposterior distance and mediolateral distance in the left foot and mediolateral distance in the right foot were not significantly different(p>.05), but anteroposterior diatance in the right foot was significantly different(p>.05). Between left and right foot, at condition 1 and 5 the mediolateral distance of COP was significantly different(p<.05) but anteroposterior distance at condition 1 and 5, anteroposterior distance and mediolateral distance of COP at condition 2, 3 and 4 were not significantly different(p>.05). Conclusion : These findings showed that the various loading position by five types of carrying a schoolbag didn't have influence significantly on COP displacement on during walking because of mechanism of postural adaption.

아기띠와 슬링 착용이 체간과 하지의 근활성 및 족저압에 미치는 영향 (The Effects of Baby Carrier and Sling in Muscle Activation of Trunk, Low Extremity and Foot Pressure)

  • 육군창;박래준;이현영;이명희;이전형;국중석;장종성
    • 대한물리의학회지
    • /
    • 제5권2호
    • /
    • pp.223-231
    • /
    • 2010
  • Purpose : The Purpose of this study was to compare muscle activation and foot pressure on baby carrier and sling for baby care. Methods : Thirty one women subjects (mean age 23.2 years) participated in four static conditions : unloaded quite standing, carrying an anterior baby carrier, carrying a posterior baby carrier, and sling. The baby carrier and sling were loaded with baby model that filled 7.6kg loads. Surface electromyography was used to measure activity in the internal oblique, T4, L3, L5 paraspinal muscle, vastus medialis, biceps femoris, tibialis anterior, and gastrocnemius for four conditions. And foot pressure was measured by using MatScan system(Tekscan, USA). Results : The activation of Biceps femoris, T4, L3, and L5 paraspinal muscle were significant differences(p<.05), but other muscles were no significant differences in four conditions(p>.05). Right foot contact area and peak pressure of right mid foot area were significant differences in four conditions(p<.05). Conclusion : The results of this study indicate that the use of baby carrier of sling for baby care were influenced postural responses of young women. Further work is recommended to find out the influences of various assistive devices for baby care.

인체모델과 3차원 일러스트레이션을 이용한 의복패턴개발 (Direct Clothing Pattern Development from the 3D Illustration on the Personal Human Body Model)

  • 박혜준;홍경희
    • 한국의류학회지
    • /
    • 제32권2호
    • /
    • pp.340-347
    • /
    • 2008
  • A prototype of 3D clothing design system with a direct pattern development function was suggested, reflecting intuitive design functions and design modifications while considering the fit of clothing patterns with the 3D human body in the virtual 3D space. The research method was as follows. Clothing models were created using a 3D design tool, 3ds max on the surface of 3D human body model made by scanning an actual human body. 3D illustrations were completed by revising the fit and sizing of the human body and clothing models. 2D T-shirt pattern was produced 3D illustrations using from a 3D scanning data modeling solution RapidForm 2004, a 2D conversion program for 3D data called 2C-AN, and Yuka CAD. As a result, the following conclusions were made. The fit of the clothing and human body can be adjusted by reflecting individual body figure characteristics and 3D illustrations over the actual 3D body model. Furthermore, intuitive design support functions were intensified overcoming the weak point of existing 3D clothing design system by developing the direct clothing design in the virtual 3D space. 3D illustration design modifications can be directly reflected on clothing patterns from 3D illustrations by 3D clothing design system developed in this study.

3T Multi Voxel Spectroscopy에서 SENSE와 NEX 변화에 따른 정상인 뇌 대사물질 변화 분석 (Alteration Analysis of Normal Human Brain Metabolites with Variation of SENSE and NEX in 3T Multi Voxel Spectroscopy)

  • 성열훈;임재동;이재현;조성봉;우동철;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.256-262
    • /
    • 2008
  • 자기공명분광법(magnetic resonance spectroscopy: MRS)은 인체내 대사물질을 정량분석하여 병변의 조기진단 및 정밀진단에 도움을 주고 있으며, 최근 임상에 이용되고 있는 자기공명분광법은 single voxel spectroscopy (SVS) 기법과 multi voxel spectroscopy (MVS) 기법이 있다. 본 연구에서는 SENSE와 NEX를 변화시킨 multi voxel spectroscopy (MVS)의 데이터와 기존 single voxel spectroscopy (SVS)의 데이터를 비교 분석하여, 각각의 데이터의 유의성 차이를 평가하고자 하였다. 정상 성인 지원자 13명(남자: 5명, 여자: 8명, 평균 41세, 표준편차 11.65세)을 대상으로 chemical shift image (CSI)를 이용한 MVS검사를 시행하였다. 장비는 3.0T Achieva Release Version 2.1 (Philips Medical System, Netherland)을 이용하였고, 8 channel head coil을 사용하여 brain thalamus 부위에서 CSI spectrum을 1 slice 획득하였다. Scan parameter로는 FOV (field of view): $230{\times}184mm^2$, TR (time to repetition): 2000 msec, TE (time to echo): 288 msec, matrix: $15{\times}12$, VOI(view of interest): $110{\times}110mm^2$, voxel size: $15{\times}15{\times}15mm^3$로 하였다. SENSE factor (S)와 NEX (N)는 S1*N1, S2*N1, S2*N2, S3*N2로 변화하여 스펙트럼을 획득하였고, 각 scan time은 5분 54초, 3분 32초, 6분 20초, 4분 20초였다. 얻은 모든 MRS 데이터는 jMRUI 3.0 Version 프로그램에서 분석하였고, SENSE factor와 NEX를 변화시켜 얻은 MVS data 그룹들이 정상 성인 뇌 대사물질의 변화에 영향을 주는지 검증하기 위해 그룹 간에 ANOVA분석을 실행하여 P 값이 0.05보다 크게 나오면 그룹들 사이에 유의한 차이가 없다고 분석하였다. NAA/Cr과 Cho/Cr의 상대적 비율은 MV와 SVS사이에서는 유의한 차이가 없었다. 즉, SENSE factor와 NEX를 변화시켜 얻은 MVS data에서 정상 성인 뇌조직의 대사물질의 변화를 관찰한 결과, S1*N1의 NAA/Cr은 $1.45{\pm}0.03$, Cho/Cr은 $0.88{\pm}0.03$이고, S2*N1의 NAA/Cr은 $1.44{\pm}0.03$, Cho/Cr은 $0.87{\pm}0.05$, S2*N2의 NAA/Cr은 $1.43{\pm}0.02$, Cho/Cr은 $0.87{\pm}0.04$이며, S3*N2의 NAA/Cr은 $1.45{\pm}0.03$, Cho/Cr은 $0.87{\pm}0.03$으로 나타났다(F-value : 1.37, D.F : 3, P-value : 0.262). 그러나 데이터의 질을 측정하기 위한 MVS 데이터의 NAA Peak line-width는 SVS 데이터의 NAA Peak line-width 보다 약 3배 정도 넓었다. 본 연구에서는 MVS에서 SENSE factor와 NEX 값을 다양하게 변화시킨 MVS의 데이터와 SVS의 데이터가 큰 차이가 없음을 확인하였다. 즉, 어는 특정 부위의 뇌 조직의 대사물질은 MVS와 SVS 기법 모두 큰 차이가 없음을 확인할 수 있었다. 그러므로 MVS는 SVS보다 광범한 부위를 짧은 시간 안에 검사할 수 있으므로 매우 유용한 방법이라고 사료된다.

  • PDF

중복요관을 가진 소아환자의 99mTc-DMSA 검사에서 부분적 관심영역 설정에 따른 신기능 평가에 관한 연구 (Study on the Evaluation of Renal Function According to Set a Partial Region of Interest in 99mTc-DMSA scan of the Pediatric Patient with a Duplicated Ureter)

  • 남궁혁;오신현;김정열;최윤정;김재삼;이창호
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.43-47
    • /
    • 2013
  • 중복요관은 요관이 두 개가 있는 선천성 신장 기형이다. 본원에서는 기형이 있는 신장 상극신의 중복요관을 하극신의 정상 요관에 연결시켜 신기능을 유지시키고자 하는 수술을 시행하고 있고, 수술 전과 후에 $^{99m}Tc-DMSA$ 검사를 시행하고 있다. 기존에는 검사 후 관심영역 설정 후 결과 도출 시에 기형이 있는 신장의 상극신과 하극신의 비교가 이루어지지 않고 정상 신장에 대한 기형이 있는 쪽 신장의 전체적인 상대적 섭취율만의 비교가 이루어졌다. 이에 본 연구는 수술 전과 후의 $^{99m}Tc-DMSA$ 검사 후 관심영역 설정 시에 기형이 있는 신장의 상극신과 하극신에 부분적인 관심영역을 각각 설정하여 기형이 있는 신장의 상극신 섭취율 변화를 통해 신실질 세포의 기능 회복 정도와 부분 관심영역 설정의 유용성에 대해 알아보고자 한다. 불완전중복요관의 기형을 가지고 수술 예정인 소아 환자 15명을 대상으로 하였다. 검사는 $^{99m}Tc-DMSA$를 1.5~1.9 MBq/kg 주사하고, 3~4시간 후에 검사하였고, 정상신장과 기형이 있는 신장의 상극신과 하극신의 관심영역을 각각 설정하였다. 관심영역은 방사선사 1명, 핵의학과 전공의 1명, 비뇨기과 전문의 1명이 동석하여 수술 전 영상과 수술 후 영상을 같은 조건과 방법으로 설정하였다. 수술 전과 후의 추적검사에서 기형이 있는 신장의 상극신 섭취율의 변화에 대해 정상신장(A), 기형이 있는 신장의 하극신(B), 상극신(C)의 섭취율비(A: B: C)를 통하여 비교해 보았다. 15명의 소아 환자에서 수술 전과 후의 기형이 있는 신장의 상극신 섭취율의 변화에 대해 정상신장(A), 기형이 있는 신장의 하극신(B), 상극신(C)의 섭취율비(A: B: C)를 통하여 비교해본 결과로 섭취율이 향상된 환자가 7명, 저하된 환자가 8명 이었다. 섭취율이 향상된 환자 7명중 2명은 수술 후 14개월, 4명은 12개월, 나머지 1명은 8개월 후에 추적검사를 하였고, 저하된 환자 8명중 4명은 수술 후 12개월, 3명은 6개월, 나머지 1명은 4개월 후에 추적검사를 한 것으로 나타났다. 기존에는 전체적인 좌.우 신장의 섭취율만을 이용하여 기형이 있는 신장의 정확한 섭취율 변화를 알아 볼 수 없었지만, 본 연구에서 제안한 부분적인 관심영역 설정방법을 이용하여 상극신과 하극신 각각의 섭취율 변화를 정확히 알아볼 수 있었다. 신장의 신실질 세포의 회복은 단기간에 평가를 하기가 어렵기 때문에 단기간의 추적검사를 통해서 기형이 있는 신장의 예후를 평가하기에는 한계가 있으며, 그렇기 때문에 장기간의 추적검사가 이루어져야 한다. 이에 부분적인 관심영역 설정방법이 유용하게 사용될 것이라고 사료된다.

  • PDF

공간정보기반 클러스터링을 이용한 초고속인터넷 결합유형별 해지의 지역별 특성연구 (A Study on the Regional Characteristics of Broadband Internet Termination by Coupling Type using Spatial Information based Clustering)

  • 박장혁;박상언;김우주
    • 지능정보연구
    • /
    • 제23권3호
    • /
    • pp.45-67
    • /
    • 2017
  • "2016 인터넷이용실태조사"에 따르면 인터넷 이용자수 및 이용률은 점점 증가하고 있으며 접속방법에 있어서는 컴퓨터보다 스마트폰을 통한 접속이 많아지고 있다. 스마트기기의 증가에 따라 초고속인터넷의 수요가 감소할 것이라는 전망도 있다. 하지만, 스마트기기의 증가에도 불구하고 기가인터넷을 통한 속도 향상과 IoT 시장의 성장으로 인해 초고속인터넷 시장은 당분간 유지될 것으로 전망된다. 시장의 포화로 인해 통신사업자들이 신규고객 확보를 위해 과도한 경쟁을 하고 있지만, 고객이탈의 원인을 알 수 있다면 보다 효과적인 마케팅을 통해 과도한 마케팅비용을 절감할 수 있을 것으로 기대된다. 본 연구에서는 통신사업자 A사가 보유하고 있는 안양시, 군포시, 의왕시 3개 도시의 결합유형별 해지 데이터와, 통계청으로부터 구한 지역별 데이터를 결합하여, 지역별 해지율과 이에 영향을 미치는 지역특성간의 관계를 분석하고자 하였다. 특히 인접지역에 따라 결합유형별 해지율의 분포에 차이가 있을 것으로 보고, 클러스터링을 이용하여 해지유형이 유사한 지역을 도출 및 분석하고자 하였다. 공간검색통계도구인 SatScan은 기존의 클러스터링 방법에 공간정보를 추가하여 인접지역을 중심으로 군집이 형성되도록 한다. 따라서 본 연구에서는 SatScan을 이용해 지역의 공간정보를 기반으로 유사지역을 군집화하고, 군집별 해지율과 지역별 데이터와의 연관성을 분석하였다. 분석 단계에서는 먼저 공간정보와 해지데이터를 결합하여 도출된 군집들의 특성을 정리하였으며, 다음으로 군집분석 결과를 바탕으로 하여 각 동의 초고속 인터넷 해지율과 지역별 데이터와의 연관성을 분산분석, 상관분석, 회귀분석을 이용하여 분석하였다. 그리고, 분석결과를 기반으로 하여 지역에 따른 적절한 마케팅 방안을 제안하였다.

I-131 SPECT/CT 검사의 에서 조준기 종류에 따른 영상 비교 평가 (Comparison of Collimator Choice on Image Quality of I-131 in SPECT/CT)

  • 김정열;김주연;남궁혁;강천구;김재삼
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.33-42
    • /
    • 2014
  • I-131의 주 에너지는 364 keV이고 이차적으로 637과 723 keV의 감마선을 방출한다. 이런 이유로 I-131 핵종을 이용한 검사에서는 일반적으로 고 에너지 조준기를 사용하고 있다. 반면 중 에너지 조준기는 과도한 격벽 투과의 영향 때문에 사용이 권고되지 않지만 I-131의 낮은 선량에 대해 계수율의 민감도를 향상시키기 위해 중 에너지 조준기를 사용하기도 한다. 이에 본 연구에서는 I-131 SPECT/CT에서 고 에너지와 중 에너지 조준기를 사용하여 조준기 선택에 대한 영상의 영향을 평가하고자 한다. I-131 점 선원과 NEMA NU-2 IQ phantom을 이용하여 Siemens symbia T16 SPECT/CT 장비로 중 에너지 조준기와 고 에너지 조준기를 사용하였다. 영상획득은 단일 에너지 창과 삼중 에너지 창으로 각각 적용하여 영상을 획득하였고, 재구성방법은 반복재구성 기법인 Flash 3D를 이용하여 CTAC, Scatter correction 적용 유무와 Iteration과 subset의 횟수를 변경하여 획득된 영상을 재구성하였다. 획득된 영상을 분석하여 두 조준기의 민감도와 대조도 그리고 잡음을 비교 평가하였다. 민감도는 중 에너지 조준기가 고 에너지 조준기보다 높게 나타났다(중 에너지 조준기: 188.18 cps/MBq, 고 에너지 조준기: 46.31 cps/MBq). 대조도는 삼중 에너지 창과 고 에너지 조준기를 사용하고 CTAC를 적용하여 16 subset 8 iteration을 적용한 재구성영상에서 가장 높은 대조도를 나타냈고(TCQI=190.64), 동일한 조건에서 중 에너지 조준기를 사용하였을 경우는 고 에너지 조준기에 비해 낮은 대조도를 나타냈다(TCQI=66.05). 잡음평가에서는 고 에너지 조준기보다 중 에너지 조준기에서 높게 나타났다 (P<0.001). 적절한 조준기의 선택은 영상의 질에 있어 중요한 사항이다. 본 연구를 통해 고 에너지 감마선을 방출하는 I-131 검사에서는 일반적으로 사용되고 있는 고 에너지 조준기를 사용하는 것이 영상의 질에 있어 가장 권고되는 바이다. 하지만 에너지 창, 매트릭스 크기, 반복 재구성 조건(subset과 iteration 수) 그리고 CTAC 및 scatter correction 여부등과 같은 조건들을 적절히 적용한다면 낮은 선량의 낮은 민감도를 갖는 조건에서는 중 에너지 조준기를 사용할 수 있을 것으로 사료된다.

  • PDF