• 제목/요약/키워드: T-P sludge injection

검색결과 5건 처리시간 0.032초

총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구 (Evaluation of Solids Removal Characteristics on Sewage Treatment Plants Using T-P sludge Return into the Primary Settling Tank)

  • 김종오;정동기;권혜정;황준석
    • 한국수처리학회지
    • /
    • 제26권6호
    • /
    • pp.73-80
    • /
    • 2018
  • In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration.

마이크로버블오존을 이용한 잉여슬러지 가용화 처리가 생물반응조의 성능에 미치는 영향 (Effect of Microbubble Ozonation Process on Performance of Biological Reactor System for Excess Sludge Solubilisation)

  • 이순화;정계주;권진하;이세한
    • 대한환경공학회지
    • /
    • 제33권2호
    • /
    • pp.113-119
    • /
    • 2011
  • 오존을 이용한 잉여슬러지 감량화 시스템이 결합된 생물학적 처리 공정에서 잉여슬러지의 무배출에 따른 생물반응조내의 영향 및 처리수질을 검토하였다. 잉여슬러지 인발량 배수($SDN_{min}$)가 3인 조건에서 잉여슬러지의 pH를 4 이하로 전 처리한 후 오존주입율 0.03 g $O_3/g$ SS로 처리한 결과 잉여슬러지의 인발 없이 안정적인 생물학적 처리가 가능하였다. $OUR_{max}$ 실험 결과, 오존주입율 0.03 g $O_3/g$ SS의 조건에서 대부분의 슬러지는 미생물 활성이 없어지는 것으로 조사되었다. 잉여슬러지의 가용화에 따른 생물반응조내에서의 MLVSS/MLSS의 변화는 거의 없었고, 반응조내 미생물의 인 축적 현상도 관측되지 않았다. 잉여슬러지 가용화 후 생물학적 처리수의 유기물 및 SS의 농도 증가 현상은 관측되지 않았고, 생물반응조내의 질산화 및 탈질율 증가로 유출수중의 T-N 농도가 감소하는 효과를 나타내었다. T-P의 경우에는 잉여슬러지의 무배출로 인해 대부분이 제거되지 않고 유출수중에 함유되어 유출되는 것으로 조사되었다.

인공습지 축산폐수처리시스템에서 질소 및 인 처리효율 향상 방안 (A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus in Livestock Treatment System Using Constructed Wetlands)

  • 서동철;박종환;김아름;김성헌;이성태;정태욱;최정호;이상원;김현욱;조주식;허종수
    • 한국토양비료학회지
    • /
    • 제44권3호
    • /
    • pp.434-441
    • /
    • 2011
  • 축산농가에서 소규모로 발생하는 고농도의 질소와 인을 함유한 축산폐수의 처리효율을 극대화시키기 위해 수생식물여과조-활성슬러지조-인공습지로 구성된 축산폐수처리 시스템에서 축산폐수 재주입 비율별 및 주입방법별 수처리 효율을 조사하였다. 축산폐수의 재주입 비율별에 따른 처리효율을 조사한 결과 COD, SS, T-N 및 T-P 처리효율은 30% < 70% ${\leq}$ 100%의 순으로 재주입 비율이 증가함에 따라 오염물질의 처리효율이 점점 증가하는 경향이었다. 또한, 주입방법에 따른 COD, SS, T-N 및 T-P의 처리효율을 조사한 결과 1차 및 2차 처리조까지는 연속적 주입이 간헐적 주입에 비해 약간 높은 처리효율을 보였으나, 3차 처리조 부터는 비슷한 처리효율을 보였으며, 방류수 중COD, SS, T-N 및 T-P의 처리효율은 연속주입방법이 각각 99.5, 99.8, 99.0 및 99.8%로 간헐주입에 비해 약간 높았다. 이들 결과를 미루어 볼 때, 본 현장 인공습지 축산 폐수처리장에서 은 적합한 축산폐수의 재주입 비율과 주입방법을 선정한다면 질소 및 인 처리효율을 향상 시킬 수 있을 것으로 판단된다.

하수처리시설에서 인 고도처리를 위한 일체형 침전부상공정(SeDAF)의 응집제 주입농도 자동제어기법 검토 (Automatic control of coagulant dosage on the sedimentation and dissolved air flotation(SeDAF) process for enhanced phosphorus removal in sewage treatment facilities)

  • 장여주;정진홍;김원재
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.411-423
    • /
    • 2020
  • To remove phosphorus from the effluent of public wastewater treatment facilities, hundreds of enhanced phosphorus treatment processes have been introduced nationwide. However, these processes have a few problems including excessive maintenance cost and sludge production caused by inappropriate coagulant injection. Therefore, the optimal decision of coagulant dosage and automatic control of coagulant injection are essential. To overcome the drawbacks of conventional phosphorus removal processes, the integrated sedimentation and dissolved air flotation(SeDAF) process has been developed and a demonstration plant(capacity: 100 ㎥/d) has also been installed. In this study, various jar-tests(sedimentation and / or sedimentation·flotation) and multiple regression analyses have been performed. Particularly, we have highlighted the decision-making algorithms of optimal coagulant dosage to improve the applicability of the SeDAF process. As a result, the sedimentation jar-test could be a simple and reliable method for the decision of appropriate coagulant dosage in field condition of the SeDAF process. And, we have found that the SeDAF process can save 30 - 40% of coagulant dosage compared with conventional sedimentation processes to achieve total phosphorus (T-P) concentration below 0.2 mg/L of treated water, and it can also reduce same portion of sludge production.

인공습지 축산폐수처리장에서 주입방법에 따른 오염물질의 제거속도 평가 (Removal Velocities of Pollutants under Different Wastewater Injection Methods in Constructed Wetlands for Treating Livestock Wastewater)

  • 김성헌;서동철;박종환;이충헌;이성태;정태욱;김홍출;하영래;조주식;허종수
    • 한국토양비료학회지
    • /
    • 제45권2호
    • /
    • pp.272-279
    • /
    • 2012
  • 자연정화공법을 이용한 축산폐수처리장에서 주입부하량에 따른 대응성을 평가하기 위해 주입방법에 따른 수처리 효율 결과를 이용하여 오염물질의 처리경향을 파악하고, 이를 토대로 설계 및 시공시 부지면적 감소와 오염물질의 처리효율 극대화를 위한 기초자료를 제시하기 위하여 주입방법에 따른 오염물질의 제거속도를 조사하였다. 축산폐수처리장에서 시기별 주입방법에 따른 수처리 효율을 조사한 결과 최종 5차 방류수에서 COD, SS, T-N 및 T-P의 처리효율은 연속적 주입의 경우는 각각 99.5%, 99.8%, 99.0% 및 99.8%였으며, 간헐적 주입의 경우는 99.2%, 99.5%, 98.5% 및 99.3%로서 상대적으로 연속적 주입이 간헐적 주입보다 높은 처리효율을 보였다. 축산폐수처리장에서 주입방법에 따른 오염물질의 제거속도 K ($day^{-1}$)는 축산폐수 주입방법을 연속적 및 간헐적으로 구분하여 각 방법에 따른 COD, SS, T-N 및 T-P의 제거속도를 각각 조사하였으며, 각 오염물질의 제거속도는 $ln(C/C_0)=-Kt$의 1차 반응속도식을 이용하였다. COD 제거상수(K)는 연속적 주입의 경우 1차, 2차, 3차, 4차 및 5차 처리조에서 각각 0.210, 0.086, 0.222, 0.053 및 $0.137\;d^{-1}$이었고, 간헐적 주입의 경우 0.377, 0.129, 0.174, 0.052 및 $0.169\;d^{-1}$였다. 그리고 T-N의 제거속도 상수(K)는 연속적 주입의 경우 1차, 2차, 3차, 4차 및 5차 처리조에서 각각0.235, 0.071, 0.171, 0.058 및 $0.126\;d^{-1}$이었고, 간헐적 주입의 경우0.361, 0.121, 0.109, 0.047 및 $0.155\;d^{-1}$이었다. T-P의 제거속도 상수(K)는 연속적 주입의 경우 1차, 2차, 3차, 4차 및 5차 처리조에서 각각 0.572, 0.049, 0.090, 0.112 및 $0.222\;d^{-1}$이었고, 간헐적 주입의 경우 0.803, 0.084, 0.076, 0.118 및 $0.301\;d^{-1}$였다. 이상의 결과를 미루어 볼때 제거속도는 연속적 주입이 간헐적 주입에 비해 빠른 경향이었으며, 본 현장 축산폐수처리장은 축산폐수 유입 부하량 변동과 순간 부하량에 대한 대응성이 우수한 것으로 판단된다.