• Title/Summary/Keyword: T-P Removal

Search Result 689, Processing Time 0.025 seconds

Effects of Domestic Wastewater Treatment used Biofilm-Electrode Reactor(BER) (生物膜 電極反應機를 이용한 廚房廢水 처리 효과)

  • Noh, Hyun-Woong;Yoon, Oh-Sub
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.1
    • /
    • pp.43-49
    • /
    • 1997
  • This study was aimed to estimate removal efficiency(%) of BER(Biofilm-Electrode Reactor) and A.S(Activated Sludge) treatments. When were analyzed COD$_{Cr}$, NH$_3$-N and T-P by current density and reaction time, the results were as follows : 1) In BER treatment, the removal efficiency of COD$_{Cr}$ in domestic wastewater was 79-86% when current density was 2.39 mA/dm$2$(15mA)-3.98 mA/dm$^2$(25mA) and reaction time was 48 hr. 2) Removal efficiency of NH$_3$-N was 71-73% when current density was 2.39-3.98 mA/dm$^2$ and reaction time 48 hr. 3) When the reaction time was 48 hr removal efficiency(%) of BER treatment for COD$_{Cr}$, NH$_3$-N and T-P were more excellent than A.S. treatment. And then we prospect that was because activated microorganism colonies attached in biofilm on surface of electrode pannel. Therefore, In order to derive BER treatment efficiency(%) should establish optimum conditions of pH, temp., reaction time, current density and biochemical and electrochemical states.

  • PDF

Buffering effects of shock loads in sequencing batch reactor (SBR에서 충격부하에 따른 완충효과)

  • Ji, Dae-Hyun;Lee, Kwang-Ho;Lee, Jae-Kune
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.581-587
    • /
    • 2008
  • In this study, we investigated the buffering effect with different COD, $NH_4{^+}-N$ and TP shock loads on the performance of lab-scale Sequencing Batch Reactor(SBR) using synthetic wastewater. This study was operated under the following conditions : HRT, 12 hrs : MLSS, 2,000 mg/L : F/M ratio, $0.2kgCOD/kgMLSS{\cdot}d$ : SRT, 20days, and was increased by a factor, COD : ranging from 200-2000 mg/L, $NH_4{^+}-N$ : ranging from 30-300 mg/L, T-P : ranging from 5-50 mg/L in the reactor. As results, COD removal rate at different shock loads was decreased until 42.1%(stable state : 95%) and concentration with effluent was higher than 695 mg/L(at Run 6). In case of $NH_4{^+}-N$ removal rate was decreased until 35.8% from 97.0% and also T-P removal rate was decreased until 5.0%. Effluent concentrations of COD, $NH_4{^+}-N$ and T-P were rapidly increased according to shock loads and needed 3, 4 and 6 additional cycle times for recovering the stable condition.

Pollutant Concentrations at Experimental Paddy Plots during Irrigation Season (관개기 시험구 논에서의 오염물질의 농도특성)

  • Cho, Jae-Won;Kim, Jin-Soo;Oh, Kwang-Young;Oh, Seung-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.3
    • /
    • pp.97-106
    • /
    • 2006
  • The pollutant concentrations at experimental paddy plots with three (excessive, standard, reduced) different fertilization rates were investigated during 2001-2002 irrigation seasons. Mean concentrations of pollutants in ponded water were not significantly different among three experimental plots, but the T-N concentrations in percolated water significantly depended on fertilization rates. The T-N, T-P and $COD_{Cr}$, concentrations in ponded water during early irrigation season (late May to mid-June) were much higher than those during later irrigation season likely due to fertilization and low uptake by young rice crops. The T-N concentrations decreased but the concentrations of T-P and $COD_{Cr}$, increased three days after tillering fertilization. The removal rates of T-N by paddy plots were $0.13-0.16g/m^2{\cdot}d$ for an excessive fertilization plot, $0.08-0.25g/m^2{\cdot}d$ for a standard fertilization plot, and $0.03-0.34g/m^2{\cdot}d$ for a reduced fertilization plot three days after tillering fertilization. On the other hand, T-P and $COD_{Cr}$, were released three days after tillering fertilization.

Effect of Advanced Wastewater Treatment by Variations Operating Conditions of 4-stage Intermittently Aerated Activated Sludge process (4단 간헐포기 공정의 운전조건이 고도처리에 미치는 영향)

  • Choi, Yong-Bum;Lee, Jeong-Gyu;Han, Dong-Joon;Kwon, Jae-Hyouk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.970-976
    • /
    • 2013
  • An evaluation of the organic matter removal efficiency showed high removal efficiencies of 91.1~96.3% and 91.4~97.5% for TCODcr and TBOD5, respectively, for 9hr or longer of HRT. However, the removal efficiencies decreased to 86.9~90.5% and 88.0~90.9%, respectively for 6hr of HRT. $NH_3$-N showed a high removal efficiency of 95% or higher for 9hr or longer of HRT. The total nitrogen removal efficiency was 67.6~76.7% for 9~12hr of HRT, and it decreased to 50% for 6hr of HRT, which seems to be due to the insufficient carbon source required for denitrification. The T-P removal efficiency was 32% on average. To comply with the legal standards, a chemical phosphorus removal process is needed after the reactor.

Estimation of Cattle Wastewater Treatment using Singang Advance Biology Reactor (SAB) (SAB 고율미생물반응기를 이용한 축산폐수처리의 성능 평가)

  • Lim, Bongsu;Kim, Doyoung;Park, Sungsoon
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.727-734
    • /
    • 2009
  • This study was carried out to evaluate the high rate biological reactor such as lab scale reactor before the application in site, and to get the basic data for possibility using liquid fertilizer with the effluent from biological reactor when the centrifugal machine was applied. The total volume of this reactor in 6 L, in composted of anoxic reactor (2 L), aerobic reactor (2 L), and nitification reactor (2 L). BOD removal efficiency rates when centrifugal machine was applied after effluent from biological reactor are over than 95%. This biological reactor was required post process to satisfy the effluent standards, and was need centrifugal machine to control the washout of microbes in the reactor. T-N removal efficiency rate in HRT 24 hr with centrifugation is 80.0%, and it is desirable to operate less than $1.3kgN/m^3{\cdot}d$ for 70% of T-N removal efficiency rate. T-P removal efficiency rate in HRT 24 hr is 68.2%, and become higher 71.3% after centrifugation. Considering in the 28.6% T-N removal efficiency rate, the nitrogen contents of the effluent from reactor is 0.34% to satisfy the liquid fertilizer.

Evaluation of SBBR Process Performance Focused on Nitrogen Removal with External Carbon Addition (외부탄소원을 사용한 SBBR의 공정 특성 및 질소제거)

  • Han, Hyejeong;Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.566-571
    • /
    • 2006
  • A sequencing batch biofilm reactor (SBBR) operated with a cycle of anaerobic - aerobic - anoxic - aerobic has been evaluated for the nutrient removal characteristics. The sponge-like moving media was filled to about 10% of reactor volume. The sewage was the major substrate while external synthetic carbon substrate was added to the anoxic stage to enhance the nitrogen removal. The operational results indicated that maximum T-N and T-P removal efficiencies were 97% and 94%, respectively were achieved, while COD removal of 92%. The observations of significant nitrogen removal in the first aerobic stage indicated that nitrogen removal behaviour in this SBBR was different to conventional SBR. Although the reasons for aerobic nitrogen removal has speculated to either simultaneous nitrification and denitrification or anoxic denitrification inside of the media, further researches are required to confirm the observation. The specific oxygen uptake rate (SOUR) test with biofilm and suspended growth sludge indicated that biofilm in SBBR played a major role to remove substrates.

A Study on the Applicability of PDA Technique in the P-CAP System for T-P Removal of STP Effluent (하수처리장 방류수의 총인 제거를 위한 P-CAP 시스템에서 PDA 기법의 활용가능성에 대한 연구)

  • Choi, Choongho;Maeng, Sungkyu;Sim, Jaehwi;Choi, Jinho;Song, Kyungguen;Lee, Byungha;Cha, Hoyoung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.729-742
    • /
    • 2012
  • Recently, to using chemical coagulation process for T-P removal in STP effluent as tertiary treatment process is generalized in the country. The importance of analysis technique to save the treatment & maintenance cost during coagulation process is becoming more increased each day. Thus, it is necessary for the analysis technique during coagulation process to be presented well the characteristic of coagulation in field apply. There are a few analysis techniques such as Jar Test, zeta potential analysis and streaming current detecting techniques. But there are difficult to apply in field immediately due to long test time and difficult analysis techniques. And using PDA technique, it is reviewed applicability of the techniques as field index on pilot plant of P-CAP system The P-CAP system is composed of an in-line static mixer, a Flocculation Tank and the CAP reactor with 2 stage weir for effluent. Pre-test is performed to fix the mixing velocity in the Flocculation Tank using the PDA equipment and it fixed with 30RPM. Also, Jar Test is performed to select optimum dose of each coagulant for each T-P concentration level of influent. Result of continuous test on pilot plant of P-CAP system, the FSI in the Flocculation Tank is increased consistently by increasing each dosing concentration of coagulant such as LAS and PAC in the low level influent T-P concentration comparatively. It is considered that formed Al-hydroxide complexes for dosed coagulant are caused FSI variation. Furthermore, it seems that FSI value in the high level influent T-P concentration appeared lower than the opposite influent condition relatively because it is formed simultaneously Al-hydroxide complexes as solid type and Al-phosphorus complexes as soluble type. Thus, relation of FSI by PDA technique and T-P removal of final effluent on pilot plant of P-CAP system are very limited for the kind of coagulant and the characteristics of influent. And it though that FSI value by PDA technique with analyzing of turbidity in Flocculation Tank will be used restrictedly on field as the relative field-index.

A study on the small sewerage system using SBR process (SBR을 이용한 소규모 오수처리시설에 관한 연구)

  • 박민정;김동석
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.427-437
    • /
    • 2003
  • An evaluation of the application of SBR and biofilm en small sewerage system was conducted. A newly developed small sewerage system, using SBR, was successfully applied to the nutrient treatment using municipal wastewater. The system was consisted of 6 compartments. Two systems, with SBR (A type) or without SBR (B type), were compared by several parameters (COD, SS, T-N, NH$_4$$\^$+/-N, NO$_3$$\^$-/-N, NO$_2$$\^$ -/-N, alkalinity, pH, DO) in all experimental periods. Also, the time variation of several parameters (DO, pH, NH$_4$$\^$+/-N, NO$_3$$\^$-/-N NO$_2$$\^$-/-N) was examined in a SBR applied sewerage system. T-N removal efficiency of B type Was higher than that Of A type by the effect of nitrification and denitrification even though the COD removal efficiencies were similar. In aeration stage, the pH was decreased from 6.4 to 6.3 within 1 h and increased to 6.65 at the end of aerobic stage, and pH was decreased to 6.2 in non-aeration stage, and these phenomena were explained. The effects of nitrification and denitrification were compared in A type and B type sewerage system, and the typical nitrification and denitrification were observed in B type sewerage system.

A Study on the Optimal Operating Conditions for Removal of Nutrient Influential Substances Using Functional Media (기능성 여재를 활용한 부영양화 영양물질 제거의 최적 운전조건 연구)

  • Lee, Jong-Jun;Oh, Jong-Min;Choi, Seung-Jong;Kim, Ki-Jung
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.6
    • /
    • pp.549-555
    • /
    • 2019
  • The purpose of this study is to ensure optimal operating conditions for improving the removal efficiency of phosphorus (P) and nitrogen (N) that are the causative agents of eutrophication by utilizing functional media. The main ingredients of the functional media used in this study are Si, Al, and Fe, SiO2, KAlSiO3O8, Al2O2·2SiO2O, H3Al2Si2O9, Fe3O4O), and berylite. To identify the maximum efficiency of the filtration process, the processing efficiency experiment was carried out according to flow method, velocity, and thickness of residual media. The flow method carried out two experiments, 50 m/day, 100 m/day, 150 m/day, 200 m/day, 250 m/day, and 20 cm, 40 cm, 50 cm, 60 cm, 80 cm of lead depth. Experiments have shown that SS, T-N, and T-P all showed higher elimination efficiency of the upflow current conditions than the downflow current conditions, and that the processing efficiency of the linearity is the highest at SS 50 m/day, T-N 150 m/day and T-P 100 m/day. In addition, the analysis of the removal efficiency according to the residual thickness showed that SS, T-N, and T-P all showed the highest efficiency at 60 cm. In addition, the analysis of the removal efficiency according to the residual thickness showed that SS, T-N, and T-P all showed the highest efficiency at 60 cm. It is considered desirable to set the top-down flow conditions and residual thickness of 60 cm and adjust the velocity of the line according to the target media for removal.

Treatment Efficiency and Plant Growth of Early Stage of Pond-Wetland System at Estuary Lake (간척지 연못-습지 시스템의 질소.인 초기 처리수준 및 식물성장)

  • Yang, Hong-Mo;Choi, Soo-Myung;Yoon, Kwang-Sik
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.426-430
    • /
    • 2001
  • Treatment efficiency and plant growth of a combined Pond-Wetland system was investigated. The system is composed of primary and secondary ponds and six wetland cells. Reed and cattail were planted as vegetation of wetland cells. The removal rates of BOD, SS, T-N, and T-P were 40%, 41%, 30%, and 47% at the secondary pond, respectively. The system removal rates measured at the last wetland cell were 57%, 54%, 60%, and 68% for BOD, SS, T-N, and T-P, respectively.

  • PDF