• Title/Summary/Keyword: T-P제거

Search Result 557, Processing Time 0.034 seconds

Extraction of PCBs by Subcritical Water Extraction (Subcritical Water Extraction에 의한 PCBs 추출)

  • Kwak, Dong Hwan;Moon, Ji Yong;Lee, Sung In;Jeong, Gi Ho
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.511-519
    • /
    • 2000
  • Water in the supercritical state ($T{\geq}374^{\circ}C$, $p{\geq}221$ atm) is a good solvent for nonorganic pollutants, but it is extremely corrosive. Subcritical Water Extraction (SWE) is a very fast and an efficient method to extract nonpolar environmental pollutants adsorbed on the sediments and soils. Many nonpolar organic compounds are sufficiently soluble to be extracted to the water under subcritical conditions. Complete extraction of PCBs from the sediments and soils takes only a few minutes by applying SWE with the subcritical water at 50 atm and at $260^{\circ}C$.

  • PDF

Comparison of Sea Level Data from TOPEX/POSEIDON Altimeter and in-situ Tide Gauges in the East Asian Marginal Seas (동아시아 주변해역에서의 TOPEX/POSEIDON 고도 자료와 현장 해수면 자료의 비교)

  • Youn, Yong-Hoon;Kim, Ki-Hyun;Park, Young-Hyang;Oh, Im-Sang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.5 no.4
    • /
    • pp.267-275
    • /
    • 2000
  • In an effort to assess the reliability of satellite altimeter system, we conducted a comparative analysis of sea level data that were collected using the TOPEX/POSEIDON (T/P) altimeter and the 10 tide gauge (TG) stations in the satellite passing track. The analysis was made using data sets collected from marginal sea regions surrounding the Korean Peninsula at T/P cycles of 2 to 230, which correspond to October 1992 to December 1998. Because of strong tidal activity in the study area, treatment of tidal errors is a very critical step in data processing. Hence in the computation of dynamic heights from the Tn data, we adapted the procedures of Park and Gamberoni (1995) to reduce errors associated with it. When these T/P data were treated, the alias periods of M$_2$, S$_2$, and K$_1$ constitutions were found at 62.1, 58.7, and 173 days. The compatibility of the T/P and TG data sets were examined at various filtering periods. The results indicate that the low-frequency signal of Tn data can be interpreted more safely with longer filtering periods (such as up to the maximum selected values of 200 days). When RMS errors for 200-day low-pass filter period was compared among the whole 10 tidal stations, the values spanned in the range of 2.8 to 6.7 cm. The results of correlation analysis at this filtering period also showed a strong agreement between the Tn and TG data sets over the whole stations investigated (e.g., P values consistently less than 0.0001). According to our analysis, we conclude that the analysis of surface sea level using satellite altimeter data can be made safely and reasonably long filtering periods such as 200 days.

  • PDF

Instantaneous Voltage Control of PWM Converters Using Feedback Linearization (궤환선형화 기법을 이용한 PWM 컨버터의 순시전압 제어)

  • 이지명;이기도;이동춘
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.175-183
    • /
    • 1999
  • For fast response of the dc output voltage in P\hi1'v1 converter, it is desirable that the relation of power balance of the i input and output terminals is introduced to the system modeling. In this case, controller desi밍1 is not easy since the m model is nonlinear. In this paper, a nonlinear control them${\gamma}$ using input-output feedback linearization is used to solve t the nonlinear problem of the system. By nonlinear control. the voltage transient response can be faster, and it is also p possible to control the output voltage to be constant with smaller output filter capacitance for load disturbance.

  • PDF

Insulation experience and character analysis of High Voltage Motor (고압전동기 절연시험 및 특성 분석에 관한 연구)

  • Choi, J.H.;Eo, S.Y.;Lee, D.Z.;Lee, J.C.;Kang, T.K.;Jeong, H.P.;Choi, J.P.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.750-751
    • /
    • 2007
  • 본 논문에서는 고압 모터의 절연열화 상태를 감시하기 위해 소선단락, 도체표면 공극, 주절연재료 내부공극, 반도전체 제거, 정상권선으로 모델권선을 제작하고 이 모델 권선에 고전압을 인가하여 shering bridge를 이용하여 교류전류의 변화분 및 정전용량, 유전정접 시험을 하였다. 이를 통해 얻어진 결과는 고압 모터의 고정자 권선의 절연상태를 판단하는 중요한 기초자료가 될것으로 판단한다.

  • PDF

Expression Study of The Mouse Collectin-Placenta 1 Gene (마우스 Collectin-Placenta 1 유전자의 발현 연구)

  • Kim, Geun Ho;Kim, Youn Uck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.477-484
    • /
    • 2019
  • Several types of scavenger receptors, including the Collectin-Placenta 1 (CL-P1) receptorthat is present in mammals, are molecules that are expressed on the surfaces of endothelial cells, macrophages and smooth muscle cells. These molecules are cell surface glycoproteins that can be conjugated to oxidized low density lipoprotein (oxLDL). Among these molecules, the effect of quercetin on CL-P1 activation has been confirmed. Quercetin is known as an antioxidant that stops oxidation because it acts to remove free radicals that are responsible for the oxidation reaction. In this study, fragments from the transcription start site of the mouse CL-P1 gene promoter to the -500th base were cloned using DNA polymerase. These fragments were then introduced into macrophage like RAW264.7 cells and fibroblast-like NIH3T3 cells to study the effect of quercetin on the CL-P1 gene expression. As a result, we found that bases ranging from -250 to -350 in the anterior part where gene expression starts are important for producing CL-P1 protein. Among them, the DNA mutation experiments we performed confirmed that the E2F binding sites are critical for producing the CL-P1 protein? In addition, when quercetin was added to the RAW264.7 culture medium, which was a culture of adherent cells, observedthe phenomenon of the cells falling off from the surface of the culture container.

A Comparison of Plaque Control Effects of Detergent Food (청정식품의 종류에 따른 치면세균막 제거효과 비교)

  • Yang, Ji-Hye;Park, Jin-Young;Yoon, Hee-In;Kim, So-Mi;Sung, Jun-Ki;Jeon, Ji-Eun;Heo, Ji-Eun;Kim, Hyun-Kyung;Mun, So-Jung;Kim, Nam-Hee
    • Journal of dental hygiene science
    • /
    • v.12 no.5
    • /
    • pp.511-515
    • /
    • 2012
  • The aim of this study was to investigate the effects of dental plaque control depending on the detergent foods. Study design was a nonequivalent control group design. Study subjects were 14 males (38.8%) and 22 females (61.1%), the age of 20.6 years old. It was conducted from March 7 to June 13, 2012. The Patient Hygiene Performance index (PHP index) was measured as a dependent variable. Detergent foods were cucumber, pear, carrot, and peach. The PHP index of detergents foods were compared using ANOVA. Paired t-test was performed. SPSS ver. 18.0 was used for the data analysis. All detergent foods which cucumber ($2.85{\pm}1.01$), pear ($2.82{\pm}0.93$), peach ($2.48{\pm}1.12$), and carrot ($2.75{\pm}0.68$) was a significant decrease in plaque index (p<0.05). However, there was no significant difference among detergent foods. Detergent foods are effective in dental plaque control. However, no difference was shown depending on the detergent foods.

Nitrogen and Phosphorus Removal in Domestic Wastewater using SBR Process with Flow Changing Continuous Feed and Cyclic Draw (교대연속유입식 SBR 공정을 이용한 하수중의 질소 및 인 제거)

  • Seo, In-seok;Kim, Hong-suck;Kim, Youn-kwon;Kim, Ji-yeon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.203-208
    • /
    • 2006
  • A continuous feed and cyclic draw SBR process was developed to overcome flow rate fluctuation and to maximize organic matters utilization efficiency for nitrogen and phosphorus removal. The developed SBR process was operated with two parallel reactors. Influent was supplied to one reactor which was not obligately aerated. At the same time, the other reactor was just aerated without supplying influent. In addition this mode was changed periodically. Cycle time was 6hr and aeration time ratio($t_{aer}/t_{total}$) was 0.33, respectively. $COD_{cr}$ and SS removal efficiencies of 95% or higher were achieved. Nitrogen removal was so greatly influenced by influent $COD_{cr}/T-N$ ratio. At influent $COD_{cr}/T-N$ ratio of 5.7, removal efficiencies of ammonia-N, T-N and T-P were 96%, 78% and 55%, respectively. Influent $COD_{cr}/T-N$ of 4 or higher ratio was necessary to achieve 60% or higher nitrogen removal. Organic matters of influent was efficiently utilized in denitrification reaction and consumed COD has a good correlation with removed T-N(about 6.5 mgCOD/mgTN). Continuous feed and cyclic draw SBR process could be one of alternative processes for the removal of nutrients in rural area where $COD_{cr}/T-N$ ratio was low and fluctuation of flow rate was severe.

Nitrogen Removal Rate of A Subsurface Flow Treatment Wetland System Constructed on Floodplain During Its Initial Operating Stage (하천고수부지 수질정화 여과습지의 초기운영단계 질소제거)

  • Yang, Hong-Mo
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.4
    • /
    • pp.278-283
    • /
    • 2003
  • This study was carried out to examine the nitrogen removal rate of a subsurface-flow treatment wetland system which was constructed on floodplain of the Kwangju River from May to June 2001. Its dimensions were 29m in length, 9m in width and 0.65m in depth. A bottom layer of 45cm in depth was filled with crushed granite with about $15{\sim}30\;mm$ in diameter and a middle layer of 10cm in depth had pea pebbles with about 10 mm in diameter. An upper layer of 5 cm in depth contained course sand. Reeds (Phragmites australis) were transplanted on the surface of the system. They were dug out of natural wetlands and stems were cut at about 40 cm height from their bottom ends. Water of the Kwangju River flowed into it via a pipe by gravity flow and its effluent was funneled back into the river. The height of reed stems was 44.2 cm in July 2001 and 75.3cm in September 2001. The number of stems was increased from $80\;stems/m^2$ in July 2001 to $136\;stems/m^2$ in September 2001. Volume and water quality of inflow and outflow were analyzed from July 2001 through December 2001. Inflow and outflow averaged 40.0 and $39.2\;m^3/day$, respectively. Hydraulic detention time was about 1.5 days. Average nitrogen uptake by reeds was $69.31\;N\;mg/m^2/day$. Removal rate of $NO_3-N$, $NH_3-N$, T-N averaged 195.58, 53.65, and $628.44\;mg/m^2/day$, respectively. Changes of $NO_3-N$ and $NH_3-N$ abatement rates were closely related to those of wetland temperatures. The lower removal rate of nitrogen species compared with that of subsurface-flow wetlands operating in North America could be attributed to the initial stage of the system and inclusion of two cold months into the six-month monitoring period. Increase of standing density of reeds within a few years will develop both root zones suitable for the nitrification of ammonia and surface layer substrates beneficial to the denitrification of nitrates into nitrogen gases, which may lead to increment in the nitrogen retention rate.

Removal of Red Tide Organisms -2. Flocculation of Red Tide Organisms by Using Loess- (적조생물의 구제 -2. 황토에 의한 적조생물의 응집제거-)

  • KIM Sung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.5
    • /
    • pp.455-462
    • /
    • 2000
  • The objective of this study was to examine the physicochemical characteristics of coagulation reaction between loess and red tide organisms (RTO) and its feasibility, in developing a technology for the removal of RTO bloom in coastal sea. The physicochemical characteristics of loess were examined for a particle size distribution, surface characteristics by scanning electron microscope, zeta potential, and alkalinity and pH variations in sea water. Two kinds of RTO that were used in this study, Cylindrothen closterium and Skeietonema costatum, were sampled in Masan bay and were cultured in laboratory. Coagulation experiments were conducted using various concentrations of loess, RTO, and a jar tester. The supernatant and RTO culture solution were analyzed for pH, alkalinity, RTO cell number. A negative zeta potential of loess increased with increasing pH at $10^(-3)M$ NaCl solution and had -71.3 mV at pH 9.36. Loess had a positive zeta potential of +1,8 mV at pH 1.98, which resulted in a characteristic of material having an amphoteric surface charge. In NaCl and $CaCl_2$, solutions, loess had a decreasing negative zeta potential with increasing $Na^+\;and\;Ca^(+2)$ ion concentration and then didn't result in a charge reversal due to not occurring specific adsorption for $Na^+$ ion while resulted in a charge reversal due to occurring specific adsorption for $Ca^(+2)$ ion. In sea water, loess and RTO showed the similar zeta potential values of -112,1 and -9.2 mV, respectively and sea sand powder showed the highest zeta potential value of -25.7 mV in the clays. EDLs (electrical double-layers) of loess and RTO were extremely compressed due to high concentration of salts included in sea water, As a result, there didn't almost exist EDL repulsive force between loess and RTO approaching each other and then LVDW (London-yan der Waals) attractive force was always larger than EDL repulsive force to easily form a floe. Removal rates of RTO exponentially increased with increasing a loess concentration. The removal rates steeply increased until $800 mg/l$ of loess, and reached $100{\%}$ at 6,400 mg/l of loess. Removal rates of RTO exponentially increased with increasing a G-value. This indicated that mixing (i.e., collision among particles) was very important for a coagulation reaction. Loess showed the highest RTO removal rates in the clays.

  • PDF

Estimation of Nutrient Removal Efficiency and Phase Conversion Rate of Single Reactor SBR and SBR with Flexible Vertical (단일 및 가변형 SBR 공법의 영양염류 처리효율 및 "상"전환속도 평가)

  • Kim, Man-Soo;Park, Jong-Woon;Park, Chul-Whi;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1215-1221
    • /
    • 2005
  • The purpose of this research was to compare the nutrient removal efficiency, and to estimate the net reaction time in order to calculate a "phase" transfer rate. SBR(SBR1) with flexible verticals and single reactor SBR(SBR1). Consequently, the removal efficiencies of $COD_{Cr}$, and $BOD_5$ in SBR1 and SBR2 were 91.5%, 97.5% and 90.4%, 97.3%, Respectively. Accordingly, the organic removal efficiency was not distinguished in both processes. In the T-N and T-P removal efficiencies, however, SBR1 obtained higher removal efficiency than SBR2, at 12.1% and 7.6% respectively. Also, in the experiment to estimate the "phase" transfer rate, SBR1 was higher than SBR2 Because SBR1 has two phases in the single reactor simultaneously, it has the buffer capacity to reduce the "phase" transfer time and provides a definite reaction condition.