• Title/Summary/Keyword: T-N removal efficiency

Search Result 326, Processing Time 0.025 seconds

A Study on the Effect of Chemical Pretreatment for Livestock Wastewater on the Linked Treatment of Sewage (축산폐수 처리 시 화학적 전처리가 연계처리에 미치는 영향 연구)

  • Han, Jun-Suk;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.89-97
    • /
    • 2010
  • In this study, to investigate the effect of chemical pretreatment for livestock wastewater, laboratory scale test for ozonation and linked treatment of sewage were conducted. and the results were obtained as follows. The ozonation of livestock wastewater showed the COD removal rate per hour to be 17%, 78% and 62% at each pH 4, 7 and 10, respectively. With transformation of NBDCOD to biodegradable BDCOD by ozonation, the ratio of SCODcr/TCODcr was increased from 26% to 38%. Accordingly, pretreatment of livestock wastewater affected to the biological post treatment process to elevate removal efficiency by transformation of nonbiodegradable mass to biodegradable mass. As the results of linked treatment of pre-ozonated livestock wastewater and sewage in the MLE process, the treatment efficiencies of TCODcr 93.8%, T-N 74.3%, T-P 89.7%, SS 97.5% were earned at 100% of internal recycle rate. When the internal recycle rate was increased to 150%, the treatment efficiencies of TCODcr 94.5%, T-N 54.5%, T-P 70.8%, SS 98.5% were earned. Also the removal efficiencies of TCODcr 92.6%, T-N 83.1%, T-P 81.9%, SS 98.5% were earned as the internal recycle rate was increased to 200%. Especially, nitrogen removal efficiency in the linked treatment showed 74.3%, 54.5%, 83.1% at 100%, 150% and 200% of internal recycle ratio, respectively, which revealed the tendency of higher removal efficiency than that of sewage treatment.

Effect of Operational Parameters on the Ammonia Stripping (암모니아 스트리핑에 미치는 운전인자의 영향)

  • Seo, Jeong-Beom;An, Kwang-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.9
    • /
    • pp.935-939
    • /
    • 2006
  • The biological nutrient removal from domestic wastewater with low C/N ratio is difficult. Therefore, this study was performed to examine effect of operational parameters such as air supply, hydraulic retention time, pH on the nitrogen removal by ammonia stripping and to increase influent C/N ratio without required carbon source. The ammonia stripping system used for the bench-scale experiment in laboratory had a dimension of 15 cm diameter and 150 cm height. The ammonia stripping reactors were classified into two types, type AS I and type AS II, according to there using or not media. Results of the research showed that the T-N removal efficiency of AS I using plastic media is slightly higher than AS II without media. In experimental condition of air supply 30 L/min and pH 12.5, T-N removal efficiencies increased as HRT of ammonia stripping reactor became longer from 8 hr to 36 hr. In experimental condition of HRT 36 hr, it was also found that the T-N removal efficiencies improved through increase of air supply. On the other hand, C/N ratio of wastewater was increased from average 3.9 to 5.4 by ammonia stripping.

Anaerobic-aerobic granular system for high-strength wastewater treatment in lagoons

  • Hamza, Rania A.;Iorhemen, Oliver T.;Tay, Joo H.
    • Advances in environmental research
    • /
    • v.5 no.3
    • /
    • pp.169-178
    • /
    • 2016
  • This study aimed at determining the treatability of high-strength wastewater (chemical oxygen demand, COD>4000 mg/L) using combined anaerobic-aerobic granular sludge in lagoon systems. The lagoon systems were simulated in laboratory-scale aerated and non-aerated batch processes inoculated with dried granular microorganisms at a dose of 0.4 g/L. In the anaerobic batch, a removal efficiency of 25% was not attained until the 12th day. It took 14 days of aerobic operation to achieve sCOD removal efficiency of 94% at COD:N:P of 100:4:1. The best removal efficiency of sCOD (96%) was achieved in the sequential anaerobic-aerobic batch of 12 days and 2 days, respectively at COD:N:P ratio of 200:4:1. Sequential anaerobic-aerobic treatment can achieve efficient and cost effective treatment for high-strength wastewater in lagoon systems.

Application in Membrane Hybrid System with Acrylic Wastewater Pretreated by $TiO_2$ ($TiO_2$로 전처리한 아크릴 폐수의 Membrane Hybrid System에의 적용)

  • Lee, Kwang-Hyun;Kang, Byung-Chul;Lee, Jong-Baek;Lee, Gang-Choon
    • Membrane Journal
    • /
    • v.19 no.3
    • /
    • pp.183-188
    • /
    • 2009
  • After membrane fouling factors in acrylic wastewater were minimized by pretreatment process accompanied with $TiO_2$, it was utilized in MF/UF/RO process. After composing of ultrafiltration/reverse osmosis or microfiltration/reverseosmosiss module set according to types and kinds of membrane, the separation characteristics were examined with the variation temperature and pressure using pretreated acrylic wastewater by membrane module sets. The permeate of ultrafiltration or microfiltration module was sent to reverse osmosis module. It was found that final permeate flux of reverse osmosis module in module set 2 (MWCO 200,000 UF+RO) was excellent. It was shown that the removal efficiency of TDS, T-N and COD was very low and was not dependent on the variation of temperature and pressure in UF and MF modules. From the above result, the removal efficiency of TDS, T-N and COD was very excellent in RO module. The removal efficiency of turbidity in UF and MF module was very high (> 99% removal efficiency). Final water quality of acrylic wastewater treated by the membrane module set was satisfied with effluent allowances limit and membrane module sets were ascertained to reuse wastewater.

Evaluation for the simultaneous Removal of Organic Matters and Nutrients by the RBC and tapered Aeration Processes with Bacillus sp. for the high Strength of Dairy Wastewater (바실러스 미생물을 이용한 고농도 유가공 폐수처리에 있어서 유기물질과 영양염류의 동시제거에 대한 평가)

  • Lee, Sang-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.195-202
    • /
    • 2010
  • The evaluation of organic matters and nutrients removal was investigated for the synthetic wastewater and the high strength of dairy wastewater. Two different systems were performed for this research. System A composing of a single RBC with tapered aeration was fed with the synthetic wastewater for 74 days with 173L/day of influent, 200% of internal return and 100% of sludge return for the period 1 and 2. The feed conditions were maintained 346L/day of influent, 50% of internal return and sludge return for the period 3. The dairy wastewater was introduced to evaluate treatment efficiency for system B composing of dual RBCs and tapered aeration tanks for 50 days of experimental run time, in which hydraulic rates were maintained at the constant ratios of 346L/day, 50% of internal return and 50% of sludge return. The spiral string media made of nylon fibre was attached by Bacillus sp. in RBC for both systems. The specific area of string media was $1.4m^2$/m and biomass was maintained at the concentrations of 23g/m. The synthetic wastewater was supplied by 1,800mg/L of glucose, 500mg/L of $NH_4Cl$, and 500mg/L of $KH_2PO_4$ to system A. The dairy wastewater was supplied to system B from dairy production plant. The average influent concentrations were 1,334mg/L of BOD, 2,014mg/L of CODcr, 160mg/L of T-N, and 12mg/L of T-P in system A. The average influent concentrations of parameters were 1,006 mg/L for BOD, 1,875mg/L for $COD_{cr}$, 51.6mg/L for T-N and 8.9mg/L for T-P in system B. Results indicated that removal efficiencies of BOD and $COD_{cr}$ were more than 90% however, the removal efficiency of T-N was 87%, and that of T-P was 82% for system A. Removal efficiencies were 98.5% of BOD, 91.3% of nitrogen and 89% of phosphorus for system B. The removal efficiencies of organic matters, T-N and T-P were higher in system B than in system A. The effluent quality issued by the stringent national legislations for the discharge of the high strength of dairy products wastewater can be improved using sequential RBCsand tapered aeration reactors rather than a single RBC and tapered aeration reactors with Bacillus sp.

A Study on Phosphorus and Nitrogen Removal with Unit Operation in the Ferrous Nutrient Removal Process (철전기분해장치(FNR)에서 단위공정에 따른 질소와 인의 제거)

  • Kim, Soo Bok;Kim, Young-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.1
    • /
    • pp.83-89
    • /
    • 2013
  • Objectives: The purpose of this experiment was to illuminate the relationship between the phosphorus removal rate of unit operation and the phosphorus removal rate of phosphorus volume loading in the Ferrous Nutrient Removal process, which consists of an anoxic basin, oxic basin, and iron precipitation apparatus. Methods: This study was conducted in order to improve the effect of nitrogen and phosphorus removal in domestic wastewater using the FNR (Ferrous Nutrient Removal) process which features an iron precipitation reactor in anoxic and oxic basins. The average concentration of TN and TP was analyzed in a pilot plant ($50m^3/day$). Results: The removal rate of T-N and T-P were 66.5% and 92.8%, respectively. The $NH_3-N$ concentration of effluent was 2.62 mg/l with nitrification in the oxic basin even though the influent was 17.7 mg/l. The $NO_3$-N concentration of effluent was 5.83 mg/l through nitrification in oxic basin even though the influent and anoxic basin were 0.82 mg/l and 1.00 mg/l, respectively. The specific nitrification of the oxic basin ($mg.NH_3$-Nremoved/gMLVSSd) was 16.5 and specific de-nitrification ($mg.NO_3$-Nremoved/gMLVSSd) was 90.8. The T-P removal rate was higher in the oxic basin as T-P of influent was consumed at a rate of 56.3% in the anoxic basin but at 90.3% in the oxic basin. The TP removal rate (mg.TP/g.MLSS.d) ranged from 2.01 to 4.67 (3.06) as the volume loading of T-P was increased, Conclusions: The test results showed that the electrolysis of iron is an effective method of phosphorus removal. Regardless of the temperature and organic matter content of the influent, the quality of phosphorus in the treated water was both relatively stable and high due to the high removal efficiency. Nitrogen removal efficiency was 66.5% because organic matter from the influent serves as a carbon source in the anoxic basin.

A Study on Treatment of Livestock Wastewater by Sequencing Batch Reactor (연속회본식 반응조를 이용한 축산폐수의 처리에 관한 연구)

  • 박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.62-66
    • /
    • 1992
  • This study was performed to investigate the characteristics of livestock wastewater excepting pig feces and the variation tendency of water quality and the removal efficiency of polluting materials by establishing the sequencing batch reactor in the field.The results were as follows, 1. The characteristics of livestock wastewater as follows: BOD: 619.80, COD$_{cr}$: 782.70, NH$_{3}$-N: 194.20, TKN: 232.81, PO$_{4}$-P: 24.10, T-P: 215.14 (mg/l) 2. During the reaction, negative correlation existed between pH and dissolved oxygen concentration. 3. The removal efficiency of the organic material by the index of BOD and COD was about 90%. 4. Nitrogen removal efficiency was 65.6% by total Kjeldahl nitrogen index, and phosphorous removal efficiency was about 47% by PO$_{4}$-P concentration.

  • PDF

Membrane-Coupled Sequencing Batch Reactor System for the Advanced Treatment of Rural Village Sewage (막결합 연속회분식 반응기를 이용한 농촌마을 하수의 고도처리)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.20-30
    • /
    • 2014
  • A membrane-coupled sequencing batch reactor (MSBR) was used for the advanced treatment of rural village sewage which is very low C/N ratio. The effect of powdered activated carbon, aeration rate, and external organic material loadings on the treatment efficiency and filtration performance were investigated in sequencing batch reactor, in which a flat-sheet type microfiltration membrane with a pore size of $0.4{\mu}m$ was submerged. At the initial operation (within 54 days) MLSS concentration, and the removal efficiencies of COD, T-N, and T-P were increased with the increase of C/N ratio. After 89 days the removal efficiencies of COD, T-N, and T-P were 97.1%, 75.0%, and 48.3%, respectively. Suspended solid-free effluent was obtained by membrane filtration. The T-P removal was relatively low because of depending on the amount of excess sludge wasting. During the operation of MSBR with powdered activated carbon, the particle size of the sludge reduced by the increase of collision frequency and mixing intensity. In comparison with MSBR without powdered activated carbon, TMP of MSBR with that was significantly elevated.

Characteristics of sewage Treatment by using Indirectly Aerated Submerged Biofilter(INSUB) (간접폭기형 침적생물여과장치(INSUB)를 이용한 오수처리 특성)

  • Huh, Mock;Kang, Jin-Yuong;Kim, Gwang-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.125-131
    • /
    • 2003
  • This study was carried out to develop INSUB(Indirected Aerated Submerged Biofilter) which can remove organics, nitrogen and phosphorus with an advanced treatment system. The results were as followed in laboratory model experiment. As for treatment of sewage, when economical efficiency was considered in practice, the highest removal efficiency was at 18hr of HRT, 1.017m/hr of superficial velocity and 40% of media packing ratio. Each removal efficiency for $COD_{cr}$, $COD_{Mn}$, $BOD_5$, T-N, and T-P was 90.6, 85.3, 95.0, 52.3 and 56.8%. To remove the nitrogen and phosphorus With high efficiency, first of all, denitrification have to be completed, then uptake of phosphorus have to completed. Therefor, mixture of anoxic and aerobic reactor was necessary for the high removal efficiency of nitrogen and phosphorus in INSUB.

  • PDF

Variation of Water Treatment Efficiency during Long-term Operation of Constructed Wetland (인공습지의 장기운영에 따른 수질정화효율 변동)

  • Son, Yeong-Kwon;Yoon, Chun-Gyeong;Kim, Hyung-Joong;Haam, Jong-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.121-128
    • /
    • 2011
  • Long-term water treatment performance analysis was conducted for the constructed wetland treating agricultural tailwater. Studied wetland was established in 2001 and operated from June, 2002 to November, 2010. Wetland vegetation cover was shown over 90 % coverage after 2005. According to vegetation development, accumulation of sediment nutrient was observed; Organic Carbon, T-P and T-N. In addition, DO concentration and temperature was decreased in the constructed wetland output. An infiltration rate also significantly decreased due to compaction of wetland soil. A runoff coefficient was increased due to the low infiltration rate after 2005. A T-N, TSS and Chl.a removal rate was maintained constantly. However, the T-P removal rate was slightly decreased along to wetland operation because low DO concentration could increase elution of phosphorus from sediment. After constructing open water, the T-P removal rate was increased. This is because open water could accelerate the reaearation process. Consequently, over three years of vegetation development could be helpful for wetland performance. In addition, DO concentration is important factor to maintain the T-P treatment.