• Title/Summary/Keyword: T-N제거

Search Result 442, Processing Time 0.025 seconds

Nutrient Removal in an Advanced Treatment Process using BIO-CLOD (BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.4
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

Evaluation of the Water Purification Efficiency of Waste LCD Glass Media by Using Foaming Technology (발포기술을 이용한 폐 LCD유리 여재의 수질정화능력 평가)

  • Ahn, Tae-Woong;Choi, I-Song;Oh, Jong-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.369-376
    • /
    • 2010
  • The purpose of this study is to reprocess Waste-LCD(Liquid Crystal Display), to widely increase specific surface-area by foaming agent in the process of reprocessing and to use as a substrate of water treatment which is increased the ability of biological treatment, as well as to control non-point source pollutants produced by surface run off during rainfall with using this substrate, and to improve water quality of public watershed as developing substrate for water treatment to be able to purify second treated water which is exhausted at the wastewater treatment plant. The average removal efficiency of Waste-LCD that using the foaming technology was SS 71.2%, BOD 55.7%, COD 58.4%, T-N 29.5% and T-P was 50.3%. Almost Media, early stage showed low removal efficiency of SS and BOD. However, it became high when the microorganism adhered the Media. The variation of SS removal efficiency was high by inflow concentration of SS. The reason for the Media 4 showed high SS removal efficiency is that it has wide specific surface-area, and also it has a pore. All in all, it shows floating matter treatment ability not only inside but it also works outside of the substrate.

Algae removal by Loess and coagulant (황토와 응집제에 의한 조류 제거)

  • 양상용;구연봉;최지혁;이인선;신찬기;유재근
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.127-130
    • /
    • 1997
  • The removal of algae was conducted by loess, aluminum sulfate and PAC on a laboratory scale. The loess was consists of organic matter 1.4%, T-N $289{\mu}g/g$, T-P $17{\mu}g/g$, $Al841.2{\mu} g/g$, Fe $592.7{\mu}g/g$, Ca $10.6{\mu}g/g$, Mg $85.5{\mu}g/g$ and Mn $6.6{\mu}g/g$. Test water was dominated by Microcystis aeruginosa. When test water was mixed with 0.01, 0.05. and 0.1 g/$\ell$ of the loess in 5 minutes, after settled in 1 hour, the removal of chl-a was 2, 22, and 36% respectively. The removal of chl-a was 69%, 70% in pH 4.5 and 9.0 and above 92% between pH 5.0 and 8.0 after the $2mg/{\ell}$ of aluminum sulfate was added. When the $2mg/{\ell}$ of PAC and $0.05g/{\ell}$ of loess were added to test water together, the removal of chl-a was 95-99% in pH 4.0-8.0, 60% in pH 9.0, and 18% in pH 10.0. The removal of chl-a was higher when loess, aluminum sulfate and PAC was used together than used alone.

  • PDF

Evaluation of SBBR Process Performance Focused on Nitrogen Removal with External Carbon Addition (외부탄소원을 사용한 SBBR의 공정 특성 및 질소제거)

  • Han, Hyejeong;Yun, Zuwhan
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.566-571
    • /
    • 2006
  • A sequencing batch biofilm reactor (SBBR) operated with a cycle of anaerobic - aerobic - anoxic - aerobic has been evaluated for the nutrient removal characteristics. The sponge-like moving media was filled to about 10% of reactor volume. The sewage was the major substrate while external synthetic carbon substrate was added to the anoxic stage to enhance the nitrogen removal. The operational results indicated that maximum T-N and T-P removal efficiencies were 97% and 94%, respectively were achieved, while COD removal of 92%. The observations of significant nitrogen removal in the first aerobic stage indicated that nitrogen removal behaviour in this SBBR was different to conventional SBR. Although the reasons for aerobic nitrogen removal has speculated to either simultaneous nitrification and denitrification or anoxic denitrification inside of the media, further researches are required to confirm the observation. The specific oxygen uptake rate (SOUR) test with biofilm and suspended growth sludge indicated that biofilm in SBBR played a major role to remove substrates.

Phosphorus Removal (Characteristics by Anoxic Oxic Process) by Anoxic and Oxic Processed Combined with Iron Electrolysis (철 석출장치가 결합된 무산소.호기공정에 의한 인 제거 특성)

  • Kim, Min-Ho;Kim, Young-Gyu;Kim, Soo-Bok
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.6
    • /
    • pp.502-509
    • /
    • 2010
  • In this study, the (phosphorous removal) the characteristics of phosphorous removal due to (the iron compound precipitated) iron compound precipitation by iron electrolysis in (the anoxic. oxic process) anoxic and oxic processes (equipped with the) in an iron precipitation device were analyzed. During the device operation period, the average concentration of BOD, T-N, and T-P were 219.9 mg/l, 54.6 mg/l and 6.71 mg/l, respectively. The BOD/$COD_{Cr}$ ratio was 0.74, and the BOD/T-N and BOD/T-P ratios were 4.0 and 32.8, respectively. The removal rate of (the organic matters) organic matter (BOD and $COD_{Cr}$) was very high at 91.6% or higher, and that of nitrogen was 80.5%. The phosphorous concentration (of the final) in the treated water was 0.43 mg/l (0.05-0.74 mg/l) on average, and the removal efficiency was high at 90.8%. The soluble T-P concentrations in (an) the anoxic reactor, oxic reactor (II) and final treated water were 1.99 mg/l, 0.79 mg/l and 0.43 mg/l, respectively, which indicated that the phosphorous concentration in the treated water was very low. Regardless of the changes in the concentrations of (organic matters) organic matter, nitrogen and phosphorous in the influent, the quality of the treated water was relatively stable and high. The removal rate of T-P somewhat increased with the increase in the F/M ratio in the influent, and it also linearly increased in proportion to the T-P loading rate in the influent. In the treatment process used in this study, phosphorous was removed (using) by the precipitated iron oxide. Therefore, the consumption of organic (matters) matter for biological phosphorus removal was minimized and (most of the organic matters were) was mostly used as the organic carbon source for the denitrification in the anoxic reactor. This (can be an economic) treatment process (without the need for the supply of additional organic matters) is economic and does not require the supply of additional organic matter.

Development of the RTDS Training Course for Control of Harmonic Currents using Passive Filters (수동필터를 이용한 RTDS 고조파 제거 모의 훈련 코스 개발)

  • Lee, N.H.;Cho, Y.S.;Lee, C.K.;Lee, W.H.;Shin, J.H.;Kim, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.304-306
    • /
    • 2005
  • This paper presents the RTDS training course on using passive filters for control of harmonic currents. The course can show harmonic currents in porer system, which is occurred by function generators, with Fourier analysis function of RTDS and the effect of passive filters implemented in RTDS to eliminate harmonics. In addition to, With Jeju-Haenam HVDC system, we have simulated the effect of passive filters on harmonic currents occurred by massive power conversion system of HVDC.

  • PDF

A Study On The Control Techniques Of Electra-Static Discharges Using Semiconductor Circuits (반도체 회로를 이용한 정전기제거에 관한 연구)

  • Oh, H.J.;Park, K.J.;Kim, B.I.;Kim, N.O.;kim, H.G.;Kim, D.T.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.19-24
    • /
    • 2002
  • Static electricity is an everyday phenomenon. There can be few of us who have not experienced a static shock after sliding across a car seat. Other static nuisance effects include the cling of some fabrics to the body, the sticking of a plastic document cover, or the attraction of dust to a TV or computer screen. However, static electricity has been a serious industrial problem. The age of electronics brought with it new problems associated with static electricity and electrostatic discharge. And, as electronic devices became faster and smaller, their sensitivity to ESD increased. In this work, We are study on the control technique of electo-static discharges using semiconductor circuits. Our circuits are prevented well to electrostatic shock or damages from triboelectric charging in cars everyday life.

  • PDF

Purification of Animal Wastewater Using a Reed-Sand-Filter System;I. Retention Period and Seasonal Variation (갈대사상여과법(砂床濾過法)을 이용한 축산폐수정화(畜産廢水淨化);I. 처리일수(處理日數) 및 계절별(季節別) 변화(變化))

  • Lee, Deog-Bae;Kim, Jong-Gu;Kang, Jong-Goog;Kim, Sun-Kwan;So, Jae-Don;Rhee, Kyeong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.231-239
    • /
    • 1994
  • A reed-sand-filter system was used to purify swine wastewater economically. Reeds (Phragmites communis Trin) were planted on the sand / gravel bed of a 20/30cm layer depth. After the input of waste-water up to a depth of l0㎝, the effluent was monitored for pollutants on the 1st, 3rd, 5th and 7th day thereafter. As swine wastewater stayed longer, the pollutants in the effluent such as T-N, $PO_4^{3-}$, COD and BOD were removed more effectively. The sand-filter system with reeds showed a superior removal efficiency to that without reeds. Especially in summer, the former showed greater purification rates than the latter, being 30% greater in T-N, 37% in $PO_4^{3-}$, 42% in COD and 30% in suspended solids. The seasonal purification efficiency was in the decreasing order of July, October and April. Reeds took up 40.1g N, 10.8g $P_2O_5$, 38.9g $K_2O$, 2.8g CaO, 2.1g MgO per square meter of the above surface area.

  • PDF

Evaluation of Removal Efficiency of Pollutants in Constructed Wetlands for Controlling Nonpoint Sources in the Daechung Reservoir Watershed (대청호 유역 비점오염원 제어를 위한 생태습지의 오염물질 제거효율 평가)

  • Pyeol-Nim Park;Young-Cheol Cho
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.2
    • /
    • pp.127-139
    • /
    • 2023
  • Daechung Reservoir has been suffering from severe cyanobacterial blooming periodically due to the water pollutants from the watershed, especially nutrients from nonpoint sources. As a countermeasure, an artificial wetland was constructed to mitigate the pollutant load from the watershed by utilizing the vegetation. We investigated the water quality of the influent and outflow of the wetland during years 2014~2020 to evaluate the performance of pollutant removal through the wetland. Major pollutants (e.g. BOD, COD, SS, T-N, and T-P) were largely reduced during the retention in the wetland while nutrients removal was more efficient than that of organic matters. Pollutant removal efficiency for different inflow concentrations was also investigated to estimate the wetland's capability as a way of managing nonpoint sources. The efficiency of water treatment was significantly higher when inflow concentrations were above 75th percentile for all pollutant, implying the wetland can be applied to the pre-treatment of high pollution load including initial rainfall runoff. Furthermore, the yearly variation of removal efficiency for seven years was analyzed to better understand long-term trends in water treatment of the wetland. The annual treatment efficiency of T-P was very high in the early stages of vegetation growth with high concentration of inflow water. However, it was confirmed that the concentration of inflow water decreased, vegetation stabilized, and the treatment efficiency gradually decreased as the soil was saturated. The findings of the study suggest that artificial wetlands can be an effective method for controlling harmful algal blooms by alleviating pollutant load from the tributaries of Daechung Reservoir.

Magnetic anomaly in the southern part of the Yellow Sea (서해남부해역의 지자기 이상대 해석)

  • Kim, Sung-Bae;Choi, Sung-Ho;Suh, Man-Cheol
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.85-92
    • /
    • 2008
  • National Oceanographic Research Institute is carrying out an oceanographic survey for the entire sea areas around Korean Peninsula annually starting with the East Sea from 1996 by establishing a national oceanographic basic map survey plan for the sea areas under the jurisdiction of Korea, so this paper used the oceanographic geomagnetism data measured at the southern area of the Yellow Sea using 'Hae Yang 2000' in 1999, aiming at clarifying the cause of geomagnetic abnormality zone during the course of treating and analyzing the geomagnetic data. For treatment of magnetic data, we obtained electromagnetic force values and geomagnetic abnormality values around the investigated sea area through a process of searching and removal of bad data, correction of sensor positions, correction of magnetic field effects around the hull, correction of diurnal variation, normal correction, correction of cross point errors, etc. The electromagnetic force distribution around the investigated sea area was $49000\;{\sim}\;51600\;nT$, which is judged to be within the normal electromagnetic force intensity distribution range around the Yellow Sea. The isodynamic lines are distributed in Northeast-Southwest direction, and electromagnetic force values are increasing toward the northwest. The result of comparing the magnetic abnormality around the sea area among $124^{\circ}$ 49' 48" E, $35^{\circ}$ 10' 48" N $\sim$ $125^{\circ}$ 7' 48" E, and $35^{\circ}$ 33' 00" N sections with the elastic wave cross section and the result of modeling coincide well with the underground geological structure clarified from the existing elastic wave survey cross section. Therefore, it is judged that the distribution of magnetic force abnormality generally shows the effect pursuant to the distribution of the sedimentary basins in the Tertiary period and the bedrocks in the Cretaceous period which are well developed in the bottom of the sea.

  • PDF