• Title/Summary/Keyword: T-Joints

Search Result 489, Processing Time 0.021 seconds

A simplified method for evaluation of shear lag stress in box T-joints considering effect of column flange flexibility

  • Doung, Piseth;Sasakia, Eiichi
    • Structural Engineering and Mechanics
    • /
    • v.73 no.2
    • /
    • pp.167-179
    • /
    • 2020
  • This study provides a simplified method for the evaluation of shear lag stress in rectangular box T-joints. The occurrence of shear lag phenomenon in the box T-joint generates stress concentration localized at both web-flange junctions of the beam, which leads to cracking or failure in the weld region of the joint. To prevent such critical circumstance, peak stress at the weld region is required to be checked during a preliminary design stage. In this paper, the shear lag stresses in the T-joints were evaluated using least-work solution in which the longitudinal displacements of the beam flange and web were presumed. The evaluation process considered particularly the effect of column flange flexibility, which was represented by an axial spring model, on the shear lag stress distribution. A simplified method for stress evaluation was provided to avoid solving complex mathematical problems using a stress modification factor βs from a parametric study. The results showed that the proposed method was valid for predicting the shear lag stress in the box T-joints manually, as well compared with finite element results. The results are further summarized, discussed, and clarified that more flexible column flange caused higher stress concentration.

Flaw Analysis Based Life Assessment of Welded Tubular Joint (결함해석에 기초한 배관용접부 수명평가)

  • Lee, Hyeong-Il;Han, Tae-Su;Jeong, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.5 s.176
    • /
    • pp.1331-1342
    • /
    • 2000
  • In power generation systems a variety of structural components typically operate at high temperature and pressure. Therefore a life assessment methodology accounting for gradual creep fracture is increasingly needed for these components. The most critical defects in such structure are generally found in the form of semi-elliptical surface cracks in the welded tubular joints. Therefore the analysis of a semi-elliptical surface crack in a plate or a shell is an important problem in engineering fracture mechanics. On this background, via shell/line-spring finite element analyses of such surface cracks in the welded T and L joints under various loadings, we investigate J-integral along the crack front We first develop T and L joints auto mesh generation program providing ABAQUS input file composed of shell/line-spring finite elements. We then further develop a T and L joints life assessment program based on the experimental creep crack growth law and auto mesh generation program in a graphical user interface format Finally the remaining life of T and L joints for various analytical parameters are assessed using the developed life assessment program.

Static test on failure process of tubular T-joints with initial fatigue crack

  • Wang, Yamin;Shao, Yongbo;Song, Shengzhi;Yang, Dongping
    • Steel and Composite Structures
    • /
    • v.24 no.5
    • /
    • pp.615-633
    • /
    • 2017
  • Fatigue crack initiated in welded tubular joints due to cyclic loading may produce harmful effect on the integrity of the tubular structures. To study such effect, both fatigue and static tests on nine circular tubular T-joint specimens made of carbon steel materials were carried out. The specimens were subjected to tensile loading in both fatigue and static tests. The load-displacement relation, the crack propagation and the failure mode of the specimens are all analyzed. The deterioration of the static strength of the cracked T-joints is also investigated and evaluated through an area reduction factor. Experimental results indicate that the static strength of a tubular T-joint with a surface crack seems to decrease slightly while a through crack has relatively remarkable effect on the reduction of the static strength. Additionally, experimental results also show that the toughness of the materials and the geometry of the specimens play an important role on the failure process of cracked tubular T-joints.

An experimental study on the unequal thickness joint using FSW with $4mm^{t}$ and $6mm^{t}$ Al 6061 T6 plates (Al 6061 T6 합금의 이두께 마찰교반 용접에 관한 연구)

  • Ryu, Deok-Hui;Kim, Jae-Seong;Jin, Hyeong-Guk;Lee, Jae-Hun;Lee, Bo-Yeong
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.223-225
    • /
    • 2005
  • In order to demonstrate the friction stir weldability of the Al 6061 T-6 unequal thickness joint and determine optimum welding parameters, the relations between welding parameters and properties of the joints have been studied in this paper. The experimental results showed that the tensile properties of the joints are affected by the welding heat inputs and tool shape. In this study, the maximum ultimate strength of the as-welded joint is equivalent to 78% and 18hour aged joint is equivalent to 93% that of the base metal. Though the voids-free joints are fractured at the thermally affected zone on the advancing side, the fracture occurs at the weld center when the void defects exist in the joints.

  • PDF

Evaluation of Design Formulae for T-joints on the Branch Plate and Hollow Steel Sections welded connections (지관 플레이트가 주관에 용접된 각형강관 접합부의 설계내력 평가에 관한 연구)

  • Park, Keum Sung;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.581-591
    • /
    • 2005
  • This paper proposes a design formulae that evaluates the design strength of T-joints made of cold-formed square hollow steel sections with longitudinal branch plate. The T-joints had a configuration that a branch member used to longitudinal plate to the main chord in the plane. This study focused on the branch plate T-joints governed by the main chord flange failure mode among the experimental results. Based on the test results of the longitudinal branch plate T-joint in the square hollow sections, the ultimate strength on the T-joints was defined as 1.5 times the load at 1% B the strength of joints that governed the serviceability in control for $16.7{\leq}2\gamma(B/T){\leq}31.3$ and $0.20{\leq}{\beta}(b1/B){\leq}0.75$. Existing yield line models for normal T-joints were investigated to be the main chord flange failure for the branch plate T-joint, and this proposal design formula was based on the theory of the yield line model. Finally, the value of the finite element method compared with the value of the test and theory for the T-joints verified the validity of the design formulae.

Experimental studies on behaviour of tubular T-joints reinforced with grouted sleeve

  • Jiang, Shouchao;Guo, Xiaonong;Xiong, Zhe;Cai, Yufang;Zhu, Shaojun
    • Steel and Composite Structures
    • /
    • v.23 no.5
    • /
    • pp.585-596
    • /
    • 2017
  • Tubular joints have been widely used in offshore platforms and space structures due to their merits such as easy fabrication, aesthetic appearance and better static strength. For existing tubular joints, a grouted sleeve reinforced method was proposed in this paper. Experimental tests on five tubular T-joints reinforced with the grouted sleeve and two conventional tubular T-joints were conducted to investigate their mechanical behaviour. A constant axial compressive force was applied to the chord end to simulate the compressive state of the chord member during the tests. Then an axial compressive force was applied to the top end of the brace member until the collapse of the joint specimens occurred. The parameters investigated herein were the grout thickness, the sleeve length coefficient and the sleeve construction method. The failure mode, ultimate load, initial stiffness and deformability of these joint specimens were discussed. It was found that: (1) The grouted sleeve could change the failure mode of tubular T-joints. (2) The grouted sleeve was observed to provide strength enhancement up to 154.3%~172.7% for the corresponding un-reinforced joint. (3) The initial stiffness and deformability were also greatly improved by the grouted sleeve. (4) The sleeve length coefficient was a key parameter for the improved effect of the grouted sleeve reinforced method.

Effects of Tool Plunge Position on Mechanical Properties of Friction-stir-weleded Region in A6061-T6/AZ31 Dissimilar Metals (A6061-T6/AZ31 이종금속 마찰교반접합부의 기계적 특성에 미치는 툴 삽입 위치의 영향)

  • Lee, Kwang-Jin;Kim, Sang-Hyuk
    • Journal of Welding and Joining
    • /
    • v.30 no.5
    • /
    • pp.22-26
    • /
    • 2012
  • Butt-joints of A6061-T6 and AZ31 plates were successfully manufactured by using a friction stir welding method. Off-set free joints and off-set joints were fabricated to investigate the effect of the tool plunge position on the mechanical properties of the joints. Hardness test, tensile test and charpy impact test was performed to evaluate the mechanical properties of the joints. Off-set condition resulted in increase of mechanical properties of the joints. The variation of the hardness distribution in the SZ was also stabilized in the off-set condition. Tensile strength of the off-set joint was about 85% against to that of the AZ31 base metal. Impact absorption energy by Charpy-Impact-Test of the off-set joint also increased by almost 2 times against to that of the AZ31 base metal.

Investigation on the seismic performance of T-shaped column joints

  • Chen, Changhong;Gong, He;Yao, Yao;Huang, Ying;Keer, Leon M.
    • Computers and Concrete
    • /
    • v.21 no.3
    • /
    • pp.335-344
    • /
    • 2018
  • More and more special-shaped structural systems have been widely used in various industrial and civil buildings in order to satisfy the new structural system and the increasing demand for architectural beauty. With the popularity of the special-shaped structure system, its seismic performance and damage form have also attracted extensive attention. In the current research, an experimental analysis of six groups of (2/3 scale) T-shaped column joints was conducted to investigate the seismic performance of T-shaped column joints. Effects of the beam cross section, transverse stirrup ratio and axial compression ratio on bearing capacity and energy dissipation capacity of column joints were obtained. The crack pattern of T-shaped column joints under low cyclic load was presented and showed a reversed "K" mode. According to the crack configurations, a tensile-shear failure model to determine the shear bearing capacity and crack propagation mechanisms is developed.

Seismic behavior of steel reinforced concrete (SRC) T-shaped column-beam planar and 3D hybrid joints under cyclic loads

  • Chen, Zongping;Xu, Jinjun;Chen, Yuliang;Xue, Jianyang
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.555-572
    • /
    • 2015
  • This paper presents an experimental study of three two-dimensional (2D/planar) steel reinforced concrete (SRC) T-shaped column-RC beam hybrid joints and six 3D SRC T-shaped column-steel beam hybrid joints under low cyclic reversed loads. Considering different categories of steel configuration types in column cross section and horizontal loading angles for the specimens were selected, and a reliable structural testing system for the spatial loading was employed in the tests. The load-displacement curves, carrying capacity, energy dissipation capacity, ductility and deformation characteristics of the test subassemblies were analyzed. Especially, the seismic performance discrepancies between planar hybrid joints and 3D hybrid joints were intensively compared. The failure modes for planar loading and spatial loading observed in the tests showed that the shear-diagonal compressive failure was the dominating failure mode for all the specimens. In addition, the 3D hybrid joints illustrated plumper hysteretic loops for the columns configured with solid-web steel, but a little more pinched hysteretic loops for the columns configured with T-shaped steel or channel-shaped steel, better energy dissipation capacity & ductility, and larger interlayer deformation capacity than those of the planar hybrid joints. Furthermore, it was revealed that the hysteretic loops for the specimens under $45^{\circ}$ loading angle are generally plumper than those for the specimens under $30^{\circ}$ loading angle. Finally, the effects of steel configuration type and loading angle on the seismic damage for the specimens were analyzed by means of the Park-Ang model.

An Experimental Study on the Flexural Behavior for T-joints with Square Hollow Structural Sections (각형강관 T형 접합부의 휨거동에 관한 실험 연구)

  • Park, Keum Sung;Lee, Sang Sup;Choi, Young Hwan;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.3
    • /
    • pp.211-219
    • /
    • 2009
  • The purpose of the study described in this paper was to experimentally investigate branch squared T joints with cold formed hollow structural sections under the in plane moment in a Vierendeel Truss. The branch in the T joints was welded to the upper flange of the chord. The main experimental parameters were the ratio of the width to the thickness of the chord ($2{\gamma}$), with ${16.7{\leq}2{\gamma}{\leq}33.3}$, and the width ratio of the branch to the chord ($\beta$), with ${0.40{\leq}{\beta}{\leq}0.71}$. Nine specimens were tested and manufactured in joints under the in plane bending moment. Based on the results of the test, the in plane moment strength of the branch squared T joints was determined according to the bending deformation of the chord flange yielding, regardless of the ratio of the width to the thickness of the chord and the ratio of the width of the branch to the width of the chord. Also, the in plane moment strength of the branch squared T joints in the hollow structural sections can be defined as 1.5 times the moment load at M1%B the strength of the joints that governed the serviceability in the control group. Finally, the experimental results with the branch squared T joints show that the in lane moment strength of the joint increased as $2{\gamma}$ decreased and $\beta$ increased.