• Title/Summary/Keyword: T detector

Search Result 431, Processing Time 0.026 seconds

A Design of the Thickness Gauge Using the Compton Gamma-ray Backscattering

  • B.S. Moon;Kim, Y.K.;Kim, J.Y.;Kim, J.T.;C.E. Chung;S.B. Hong
    • Nuclear Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.457-464
    • /
    • 2000
  • In this paper, we describe the results of various calculations performed for a design of the thickness gauges that use the gamma-ray backscattering method. The radiation source is assumed to be the $_{24}$1Am(60keV gamma-ray) and the detector is a single crystal scintillator in a cylindrical form. The source is located at the center of the detector with the collimator of a cylindrical shape. First, when gamma-rays are incident on a material with a constant angle, we compute the variations of the spectrum for the photons scattered into different angular intervals. Next, we compute for an optimal size for the collimator cylinder for a fixed detector size and an optimal distance from the detector to the material. Finally, we compute the number of observed photons for different thickness of two different materials, a plastic film and an Al foil.

  • PDF

Calibration of cylindrical NaI(Tl) gamma-ray detector intended for truncated conical radioactive source

  • Badawi, Mohamed S.;Thabet, Abouzeid A.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1421-1430
    • /
    • 2022
  • The computation of the solid angle and the detector efficiency is considering to be one of the most important factors during the measuring process for the radioactivity, especially the cylindrical γ-ray NaI(Tl) detectors nowadays have applications in several fields such as industry, hazardous for health, the gamma-ray radiation detectors grow to be the main essential instruments in radiation protection sector. In the present work, a generic numerical simulation method (NSM) for calculating the efficiency of the γ-ray spectrometry setup is established. The formulas are suitable for any type of source-to-detector shape and can be valuable to determine the full-energy peak and the total efficiencies and P/T ratio of cylindrical γ-ray NaI(Tl) detector setup concerning the truncated conical radioactive source. This methodology is based on estimate the path length of γ-ray radiation inside the detector active medium, inside the source itself, and the self-attenuation correction factors, which typically use to correct the sample attenuation of the original geometry source. The calculations can be completed in general by using extra reasonable and complicate analytical and numerical techniques than the standard models; especially the effective solid angle, and the detector efficiency have to be calculated in case of the truncated conical radioactive source studied condition. Moreover, the (NSM) can be used for the straight calculations of the γ-ray detector efficiency after the computation of improvement that need in the case of γ-γ coincidence summing (CS). The (NSM) confirmation of the development created by the efficiency transfer method has been achieved by comparing the results of the measuring truncated conical radioactive source with certified nuclide activities with the γ-ray NaI(Tl) detector, and a good agreement was obtained after corrections of (CS). The methodology can be unlimited to find the theoretical efficiencies and modifications equivalent to any geometry by essential sufficiently the physical selective considered situation.

A Study on image noise removal of $2^{nd}$ electron detector for a E-Beam Lithography (전자빔 가공기를 위한 2 차 전자 검출기의 영상 노이즈 제거에 관한 연구)

  • Im Y.B.;Moon H.M.;Joe H.T.;Paek Y.J.;Lee C.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1741-1744
    • /
    • 2005
  • The electron beam machining provides very high resolution up to nanometer scale, hence the E-Beam writing technology is rapidly growing in MEMS and nano-engineering areas. For E-Beam machining, $2^{nd}$ electron detector is required to see a machined sample at the stage. The $2^{nd}$ electron detector is composed of scintillator and photomultiplier with signal amplifier and high voltage power supplier. Since a photomultiplier tube is an extremely high-sensitivity photodetector, the signal light level to be detected is very low and therefore particular care must be exercised in shielding external light. In this paper, the design methodology of $2^{nd}$ electron detector and the image noise removal method are introduced.

  • PDF

Study on the cascade summing correction for high efficiency HPGe detector (고효율 HPGe 검출기의 동시합성효과 보정 연구)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.3
    • /
    • pp.107-112
    • /
    • 2005
  • Cascade summing occurs when two gamma-rays emitted in the decay of a single nucleus both deposit energy in a detector. The effect may cause systematic errors that can reach levels of more than ten percent for some radionuclides. A method for estimation of the effect of these coincidences was developed. It is based on direct computation of the effect by means of peak to total ratio measured for the place around the detector. It has been shown that the P/T ratio for the given energy in the working space around the detector may not be a constant value and must use its mean value. Some results from a peak to total calibration study in the presence of scattering materials are also given.

Effects of A-solution on Halitosis and Oral Status in Preoperative NPO Patients (A-solution을 이용한 구강 가글링이 수술 전 금식 환자의 구취와 구강 상태에 미치는 효과)

  • Song, Ji-Ah;Hur, Myung-Haeng
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.3
    • /
    • pp.405-413
    • /
    • 2012
  • Purpose: The aim of this study was to explore the effects of A-solution on halitosis and oral status in preoperative NPO patients. Methods: A nonequivalent control group, non-synchronized pretest-posttest design was used in this study. The participants in this study were 66 patients who were admitted for gynecologic surgery. The experimental treatment was to give oral gargling with A-solution, blended essential oils and diluted with distilled water. To identify the experimental treatment effects, halitosis, salivary pH, and oral status were measured by a portable halitosis detector, visual analogue scale, Bromo Thymol Blue (BTB), Bromo Cresol Purple (BCP) test paper and oral assessment guide. Data were analyzed using $X^2$-test, t-test with PASW 18.0 version. Results: Participants were homogeneous before experimental treatment. Objective halitosis in the experimental group, measured by a portable halitosis detector (t=-8.34, p<.001) was significantly lower than the control group. Subjective halitosis was significantly lower in the experimental group (t=-9.29, p<.001). Salivary pH was significantly different between two groups (t=8.81, p<.001). Oral status was significantly better in the experimental group (t=-13.31, p<.001). Conclusion: These findings indicate that oral gargling using A-solution is effective in reducing patient halitosis, and improving oral status.

Performance Analysis of DVB-T2 Turbo Equalization with LDPC and MAP Detector (LDPC 복호와 MAP 등화기를 결합한 DVB-T2 터보 등화기법의 성능분석)

  • Tai, Qing Song;Han, Dong-Seog
    • Journal of Broadcast Engineering
    • /
    • v.15 no.5
    • /
    • pp.665-671
    • /
    • 2010
  • In this paper, a turbo equalizer is proposed for the digital video broadcasting for terrestrial - 2nd generation (DVB-T2) system. The proposed turbo equalizer is consisted with the maximum a posteriori (MAP) and low density parity check (LDPC) decoder. The channel information for the soft-input-soft-output (SISO) MAP equalizer is based on the least square (LS) channel estimator. The performance is analyzed through computer simulations in terms of the iteration number.

Measurement of Ultrasonic Nonlinearity Parameter of Fused Silica and Al2024-T4 (Fused Silica와 Al2024-T4의 비선형 파라미터 측정)

  • Kang, To;Lee, Taekgyu;Song, Sung-Jin;Kim, Hak-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.14-19
    • /
    • 2013
  • Nonlinearity parameter is an inherent property of materials measuring fundamental acoustic amplitude($A_1$) and second harmonic amplitude($A_2$). However, measurement of $A_1$ and $A_2$ has complex calibration procedure, many researchers prefer to measure relative nonlinearity parameter rather than absolute nonlinearity parameter. But, relative nonlinearity parameter is only detect materials degradation with various degradation samples, it is limited application in determining third order elastic constants of materials. Therefore, in this study, the piezoelectric detection method is adopted to measure absolute nonlinearity parameter due to experimental simplicity compare to capacitive detector. Linearity of measurement system is verified by $A_1^2vsA_2$ plot, and we measured ultrasonic nonlinearity parameters of fused silica and Al2024-T4.

Maximum a posteriori CFAR for weibull clutter (Weibull clutter 에 대한 최대사후확률 일정오경보수신기)

  • Yu, Kung-T.;Seo, Jin-H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.146-148
    • /
    • 1995
  • A CFAR algorithm for weibull clutter is discussed. The Maximum a posteriori(MAP) estimator for two parameters(skewness and scale) of the weibull clutter is proposed, assuming the probability density function of skewness parameter is known. And proposed MAP estimator is compared with the Maximum likelihood(ML) estimator. Using this MAP estimator, we can design CFAR detector which is shown to have smaller CFAR loss than ML CFAR detector by the statistical simulation method.

  • PDF

The Demodulation for Bipolar Delta Driven GMSK (바이폴라 델타 구동 GMSK에 대한 복조)

  • Bang, Seung-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.10
    • /
    • pp.824-831
    • /
    • 2013
  • The delta driven GMSK is a modulation scheme to generate the gaussian pulse by the bipolar delta signal and to modulate the phase function with the differential gaussian pulse between $+T_b/2$ and $-T_b/2$. The demodulation of delta driven GMSK differs from conventional GMSK schemes. This paper proposed a demodulation with the differential phase detector at the end of each bit interval. A designed detector then finds the one of the possible region by hard decision, in which the phase difference lies. Finally the binary data can be recovered by state transition process. Through the BER simulation for AWGN channel, it was found that the proposed demodulation effected by the run length of binary data. The simulated BER degradation of about 2[dB] was analyzed, as compared to the theoretical coherent demodulation with $BT_b$=0.3.