• Title/Summary/Keyword: T -wave

Search Result 1,258, Processing Time 0.028 seconds

Tsunami wave Simulation y Sign Method - Its application in the East Sea - (Sign Method를 이용한 쯔나미파의 모의실험 - 동해에서의 적용 -)

  • 정종률;김성대
    • 한국해양학회지
    • /
    • v.28 no.3
    • /
    • pp.192-201
    • /
    • 1993
  • To reduce tsunami hazards, it is necessary to develope the methods which can simulate tsunami wave signals of coastal areas. In the present paper, it is attempted t use Sign Method for analyzing and simulating recorded tsunami signals. A tsunami record Y(t) can be represented as the convolution integral of a source evolution function E(t') and a wave propagation function K(t-t') Y(t)=.int. E(t')K(t-t')dt' A source function contains the peculiarities of a tsunami generator. A wave function is a kind of transfer function which contains the characteristics of a wave propagation path. The source functions and the wave function and the wave functions of 9 Korean coast points and 6 Japan coast points are estimated, and the tsunami wave signals are simulated by the convolution integrals of the source functions and the wave functions. According to the results of analysis, the Sign Method is an effective method for simulating tsunami wave signals of Korean coast points which are located far from tsunami source areas. Furthermore, if the source function of a neighboring point ad the wave function of an another tsunami are given, unrecorded tsunami wave also can be estimated.

  • PDF

Source & crustal propagation effects on T-wave envelopes

  • Yun, Suk-Young;Park, Min-Kyu;Lee, Won-Sang
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2010.10a
    • /
    • pp.27-27
    • /
    • 2010
  • There have been several studies about empirical relation between seismic source parameters(e.g., focal mechanisms, depths, magnitudes, etc.) and T-wave observation. In order to delineate the relation, numerical and theoretical approaches to figure out T-wave excitation mechanism are required. In an attempt to investigate source radiation and wave scattering effects in the oceanic crust on T-wave envelopes, we perform three-dimensional numerical modeling to synthesize T-wave envelopes. We first calculate seismic P- and SV-wave energy on the seafloor using the Direct Simulation Monte Carlo based on the Radiative Transfer Theory, which enables us to take into account both realistic seismic source parameters and wave scattering in heterogeneous media, and then estimate excited T-wave energy by normal mode computation. The numerical simulation has been carried out considering the following different conditions: source types (strike and normal faults), source depths (shallow and deep), and wave propagation through homogeneous and heterogeneous Earth media. From the results of numerical modeling, we confirmed that T-wave envelopes vary according to spatial seismic energy distributions on the seafloor for the various input parameters. Furthermore, the synthesized T-wave envelopes show directional patterns due to anisotropic source radiation, and the slope change of T-wave envelopes caused by focal depth. Seismic wave scattering in the oceanic crust is likely to control the shape of envelopes.

  • PDF

T Wave Detection Algorithm based on Target Area Extraction through QRS Cancellation and Moving Average (QRS구간 제거와 이동평균을 통한 대상 영역 추출 기반의 T파 검출 알고리즘)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.2
    • /
    • pp.450-460
    • /
    • 2017
  • T wave is cardiac parameters that represent ventricular repolarization, it is very important to diagnose arrhythmia. Several methods for detecting T wave have been proposed, such as frequency analysis and non-linear approach. However, detection accuracy is at the lower level. This is because of the overlap of the P wave and T wave depending on the heart condition. We propose T wave detection algorithm based on target area extraction through QRS cancellation and moving average. For this purpose, we detected Q, R, S wave from noise-free ECG(electrocardiogram) signal through the preprocessing method. And then we extracted P, T target area by applying decision rule for four PAC(premature atrial contraction) pattern another arrhythmia through moving average and detected T wave using RT interval and threshold of RR interval. The performance of T wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. The achieved scores indicate the average detection rate of 95.32%.

P-wave Detection Using Wavelet Transform (Wavelet Transform을 이용한 P파 검출에 관한 연구)

  • 윤영로;장원석
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.507-514
    • /
    • 1996
  • The automated ECG diagnostic systems in hospital have a low P-wave detection capacity in case of some diseases like conduction block. The purpose of this study is to improve the P-wave detection ca- pacity using wavelet transform. The first procedure is to remove baseline drift by subtracting the median filtered signal from the original signal. The second procedure is to cancel ECG's QRS-T complex from median filtered signal to get P-wave candidate. Before we subtracted the templete from QRS-T complex, we estimated the best matching between templete and QRS-T complex to minimize the error. Then, wavelet transform was applied to confirm P-wave. In particular, haiti wavelet was used to magnify P-wave that consisted of low frequency components and to reject high frequency noise of QRS-T complex cancelled signal. Finally, p-wave was discriminated and confirmed by threshold value. By using this method, We can got the around 95.1% P-wave detection. It was compared with contextual information.

  • PDF

A Study on Effects of incense smokes of 'Cheung-Woon' on Concentration (한방(韓方) 훈법(熏法)을 이용한 '청운(淸雲)'의 집중력 효과에 관한 연구)

  • Uhm, Ji-Tae;Kim, Byoung-Soo;Kim, Kyoung-Shin
    • Journal of Oriental Neuropsychiatry
    • /
    • v.23 no.2
    • /
    • pp.33-48
    • /
    • 2012
  • Objectives : This study aimed to assess the effects of incense smokes of 'Cheung-Woon' on the concentration and EEG in healthy individuals. Methods : A total of 48 healthy volunteers participated in this study. The volunteers were examined with K-MAS, CBT(Corsi block tapping task), and EEG before and after smelling the incense smokes of 'Cheung-Woon'. K-MAS measured the recalled words, and CBT measured the recalled positions and orders of the color boxes. EEG measured the relative power of ${\theta}$ wave, ${\alpha}$ wave, SMR wave, mid-${\beta}$ wave, high-${\beta}$ wave, ${\gamma}$ wave and T(concentraion index T = (SMR wave + mid-${\beta}$ wave) / ${\theta}$ wave). 'Cheung-Woon' consists of 7 herbal powder, known as a useful effect on the concentration and memory. Results : After smelling 'Cheung-Woon', K-MAS were increased significantly(p<0.05). In relative power of ${\theta}$ wave, F4, T3, and P4 were decreased significantly(p<0.05) and P3 was also decreased significantly(p<0.01). In the relative power of ${\alpha}$ wave, SMR wave, and mid-${\beta}$ wave, the values were not significant. In the relative power of high-${\beta}$ wave, Fp1, and P4 were increased significantly(p<0.05). In relative power of ${\gamma}$ wave, T3 were increased significantly (p<0.05). In T value, F4, T3, T4, and P4 were increased significantly(p<0.05) and P3 were also increased significantly(p<0.01). Conclusions : This results show that smelling incense smokes of 'Cheung-Woon' is an effective way of increasing concentration and memory.

BLOW-UP OF SOLUTIONS FOR WAVE EQUATIONS WITH STRONG DAMPING AND VARIABLE-EXPONENT NONLINEARITY

  • Park, Sun-Hye
    • Journal of the Korean Mathematical Society
    • /
    • v.58 no.3
    • /
    • pp.633-642
    • /
    • 2021
  • In this paper we consider the following strongly damped wave equation with variable-exponent nonlinearity utt(x, t) - ∆u(x, t) - ∆ut(x, t) = |u(x, t)|p(x)-2u(x, t), where the exponent p(·) of nonlinearity is a given measurable function. We establish finite time blow-up results for the solutions with non-positive initial energy and for certain solutions with positive initial energy. We extend the previous results for strongly damped wave equations with constant exponent nonlinearity to the equations with variable-exponent nonlinearity.

P Wave Detection based on QRST Cancellation Zero-One Substitution

  • Cho, Ik-Sung
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2021
  • Cardiac arrhythmias are common heart diseases and generally cause sudden cardiac death. Electrocardiogram (ECG) is an effective tool that can reveal the electrical activity of the heart and diagnose cardiac arrhythmias. We propose detection of P waves based on QRST cancellation zero-one substitution. After preprocessing, the QRST segment is determined by detecting the Q wave start point and T wave end point separately. The Q wave start point is detected by digital analyses of the QRS complex width, and the T wave end point is detected by computation of an indicator related to the area covered by the T wave curve. Then, we determine whether the sampled value of the signal is in the interval of the QRST segment and substitute zero or one for the value to cancel the QRST segment. Finally, the maximum amplitude is selected as the peak of the P wave in each RR interval of the residual signal. The average detection rate for the QT database was 97.67%.

A P-wave and T-wave detection algorithm in EGG by using slope tracing waves (기울기 추적파를 이용한 심전도의 P-파 및 T-파 검출 알고리즘)

  • Kim, Min-Kyu;Byun, Mi-Kyung;Lee, Ki-Young;Kim, Jung-Kuk;Jeong, Byung-Doo;Huh, Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.35-37
    • /
    • 2005
  • In this study, a P- and T-wave detection algorithm in ECG, obtained by minimized filtering to prevent waveform distortion, has been realized. The algorithm uses two slope tracing waves, the descending slope tracing wave and the ascending slope tracing wave, developed for efficient determination of slope inverting points and sudden slope changing points. The algorithm generates the slope tracing waves which trace the original ECG wave, and subtracts one tracing wave from the other to detect P- and T-waves. The algorithm has been applied to MIT/BIH database in order to verify its efficacy and validity in practical applications.

  • PDF

Low Rayleigh Number Thermal Convection Between Two Horizontal Plates with Sinusoidal Temperature Distributions (정현적인 온도 분포를 갖는 두 수평 평판 사이에서의 작은 Rayleigh 수 열 대류)

  • 유주식;김용진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.145-152
    • /
    • 2001
  • Low Rayleigh number thermal convection in a fluid layer confined between two-infinite horizontal walls kept at spatially sinusoidal temperature distributions, T_L=T_m+\Delta T\sin \kappax,\;T_U=T_m+\Delta T\sin(\kappax-\beta)$, is theoretically investigated by a regular perturbation expansion method. For small wave numbers, an upright cell is formed between the two walls at $\beta$=0. The cell is tilted, as the phase difference increases, and a flow with tow counter-rotating eddies occurs at $\beta=\pi$. when the wave number is large, isolated eddies are formed near the lower and upper walls, for all the phase differences. There exists a wave number at which maximum heat transfer rate at the walls occurs, at each of the phase differences. And the wave number increases with increase of the phase difference. for a fixed wave number, the heat transfer rate decrease with increase of the phase difference.

  • PDF

R and T Wave Amplitude as a Parameter to Detect Coronary Artery Disease (관상동맥질환을 진단하기 위한 R파와 T파의 크기에 대한 연구)

  • Lim, Hyun-Kyoon;Yu, Kwon-Kyu;Kim, Jin-Mok;Kim, In-Seon;Kang, Chan-Seok;Park, Yong-Ki
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.6-11
    • /
    • 2008
  • Multi-channel magnetocardiography (MCG) has been proposed to detect ischemic heart disease because its sensitivity is quite high comparing with other conventional diagnostic tools. Especially, current map and magnetic field map of MCG provide crucial information on whether myocardiac muscles maintain the normal conduction pathway. In addition, MCG parameters derived from repolarization are useful to detect coronary artery disease. Recently, there was a study reporting that R- and T- wave amplitude are highly correlated with ischemic heart disease. In this study, we studied R- and T-wave amplitude and their ratio as well as MCG parameters. MCG data from 20 young, 20 age-matched controls, and 20 myocardial infarction (MI) patients were analyzed. As a result, MCG parameters showed significant change in MI patients comparing to those of controls. R- and T-wave amplitude of MI patients showed a feature of severe ischemic heart disease even though it was difficult to find consistent values. Further study is needed to reveal the relations between small T-wave amplitude and coronary artery disease.

  • PDF