• Title/Summary/Keyword: T/R coil

Search Result 42, Processing Time 0.026 seconds

Evaluation of Reproducibility According to Variation of Coil Channel in Quantitative Evaluation Using Synthetic MR (Synthetic MR을 이용한 정량적 평가에서 Coil channel 수 변화에 따른 재현성 평가)

  • Kwon, Soon-Yong;Kim, Seong-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.343-351
    • /
    • 2017
  • T1, T2 relaxation time and relaxation rates were measured and analyzed according to the change of RF coil channel number of MAGiC sequence. T1, T2, R1 and R2 maps were obtained by using MAGiC sequence with phantom (1.0, 0.6, 0.2, 0 mM) on the RF coil with channel number of 1, 8, 16 and 32 respectively. T1, T2, R1, R2 values and relaxation rates were measured for each channel number and concentration, and Relaxivity was calculated according to each concentration. T1, T2, R1, and R2 values were measured in each coil. There was no significant difference between T1 and R1 values (p> 0.05). However, T2 and R2 values were significantly different (p <0.05). In the post-analysis results, T2 value was significantly different from that measured on 1, 8, 16, and 32 channel coils (p <0.05) and There was no difference between 8, 16, and 32 channel coils (p> 0.05). The R2 value was significantly different from that measured on the 8, 16, and 32 channel coils in the 1 channel coil, and the results on the 8 channel coils and the 16 channel coils showed a significant difference (P <0.05). In conclusion, T1 and R1 values were not significantly different according to the number of channels in the coil, but T2 and R2 values were significantly different. Therefore, when quantitative measurement of T2 and R2 values using the MAGiC sequence, the same number of coils should be used for reproducibility.

Eddy Current Signal Analysis for Transmit-Receive Pancake Coil on ECT Array Probe

  • Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.1
    • /
    • pp.25-29
    • /
    • 2006
  • In this paper, the eddy current signals come from a pair oi transmit-receive (T/R) pancake coil on ECT array Probe are analyzed with the variations of the lift-of and of the distance between transmit and receive coils. To obtain the electromagnetic characteristics of the probes, the governing equation describing the eddy current problems is derived from Maxwell's equation and is solved using three-dimensional finite element method. Eddy current signals from T/R coils on ECT array probe have quite different characteristics compared with ones from impedance coil on rotating pancake coil probe. The results in this paper ran be helpful when the field eddy current signals from ECT array probe are evaluated.

Signal Analysis of Eddy Current Test Using T/R Coil Probe for Inspection of Steam Generator Tube in NPP (T/R코일프로브를 이용한 원전 SG세관 검사의 와전류탐상 신호해석)

  • Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.159-165
    • /
    • 2008
  • In this paper the signal analysis of eddy current test using transmit-receive(T/R) pancake coil of ECT array probe using electromagnetic finite element method(FEM) is performed. For characteristics analysis, the notch defect is used. The depth of defect is 40[%] of steam generator tube thickness, and inside defect and outside defect are used as simulation examples. The signal analysis is performed according to the variation of receive coil position. The receive coil is positioned $0[^{\circ}]$, $30[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$ of circumferential position of transmit coil. To obtain e electromagnetic characteristics of robes, the governing equation is derived from Maxwell's equations, and the problem is solved using the 3-dimensional finite element method. The signal magnitude of inside defect is bigger than that of outside defect, and the signal difference can be seen according to the variation of position of receive coil. The experimental signal and numerical signal of ASME standard tube show similar results. The results in this paper can be helpful when the ECT signals from ECT array probe are evaluated and analyzed.

A Study on Optimal Insulation Design of the Distribution Level HTS FCL (배전급 고온초전도 한류기 절연설계 최적화 연구)

  • Seok, B.Y.;Kang, H.;Lee, C.;Nam, K.;Ko, T.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.723-724
    • /
    • 2006
  • In this study, superconducting coil arrangements and cryostat concept design were conducted for the development of 13.2kV/630A bifilar winding type high temperature superconducting(HTS) fault current limiter(FCL) with YBCO coated conductor(CC) wire. The coil consists of several layers with unique non-inductive solenoid winding method. Six types of HTS coil arrangements were investigated for the optimal insulation design of HTS FCL. And, conceptual design of cryostat was conducted for the decrement of thermal invasion and the prevention of low voltage insulation breakdown in the LHe which is used as pressurization gas in sub-cooling condition of liquid nitrogen(LN2). As the results, it was found that the modified suspended type cryostat with horizontal coil arrangement is beneficial to the insulation design of 13.2kV level bifilar winding type HTS FCL.

  • PDF

Study on fabricated RF coil using high-temperature superconductor tape and matching circuit for low field MRI system (고온초전도 선재와 정합회로를 이용한 RF coil 제작에 대한 기초연구)

  • Kim, D.H.;Ko, R.K.;Kang, B.M.;Ha, D.W.;Sohn, M.H.;Mun, C.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.44-47
    • /
    • 2012
  • The substantial improvement of the signal-to-noise ratio (SNR) can be achieved with small-size samples or low-field MRI system by high-temperature superconducting(HTS) RF coil. The typical HTS RF coil made of HTS thin film is expensive and is limited the coil geometry to planar surface coil. In this study, commercial Bi-2223 HTS tapes was used as RF coil for a 0.35T permanent MRI system. It has advantages of both much lower cost and easier fabrication over HTS thin film coil. SNR gain of the image obtained from the HTS RF coil over a conventional Cu RF coil at room temperature was about 2.4-fold and 1.9-fold using the spin echo pulse sequence and gradient echo pulse sequence respectively.

Dual Birdcage RF Coil for Leg MR Angiography (하지 MR Angiography를 위한 Dual Birdcage RF 코일)

  • 양윤정;김선경;최환준;김호철;오창현
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.75-78
    • /
    • 1997
  • A dual birdcage RF coil is proposed for MRI and MRA of the human leg. The proposed coil c can be used to cover the whole human leg by imaging upper and lower parts of the leg separately. In the conventional leg imaging scheme using a single RF coil, the leg has to be r relocated when changing the position of the RF coil thus causing problems in matching the i images from two sets of coils. When using the proposed dual RF coil, however, only the bed h has to be moved to select the imaging region while only one part of the dual coil is used each t time by using current switching and PIN diodes. The utility of proposed coil has been verified b by volunteer MRI and MRA and the imaging results show that the coil is useful for the clinical MRI and MRA of the leg.

  • PDF

A Study on sorting out base metal using eddy current sensor (와전류 센서를 이용한 금속 모재 선별에 관한 연구)

  • Lee G.S.;Kim T.O.;Kim H.Y.;Ahn J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1788-1792
    • /
    • 2005
  • Eddy current sensor is representative instrument measuring gap to base metal and sensing trouble in base metal. The existing eddy current sensor works as measuring variance of sensor coil's inductance. But, sensor coil have phenomenon that not only inductance but also real resistance varies in real action. Conductivity and Permeability are main variable in sensor coil's varying impedance(inductance, real resistance). By searching relationship between conductivity-permeability and sensor coil's impedance, eddy current sensor gain advantage of elevation of accuracy, removal of alignment to each base metal, and continuous sensing to varying base metal.

  • PDF

Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Kim, Min-Ji;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

Postmortem analysis of a failed liquid nitrogen-cooled prepolarization coil for SQUID sensor-based ultra-low field magnetic resonance

  • Hwang, Seong-Min;Kim, Kiwoong;Yu, Kwon Kyu;Lee, Seong-Joo;Shim, Jeong Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.44-48
    • /
    • 2014
  • A liquid nitrogen-cooled prepolarization ($B_p$) coil made for ultra-low field nuclear magnetic resonance and magnetic resonance imaging (ULF-MR) designed to generate 7 mT/A was fabricated. However, with suspected internal insulation failure, the coil was investigated in order to find out the source of the failure. This paper reports detailed build of the failed $B_p$ coil and a number of analysis methods utilized to figure out the source and the mode of failure. The analysis revealed that pyrolytic graphite sheet linings put on either sides of the coil for better thermal conduction acted as an electrical bridge between inner and outer layers of the coil to short out the coil whenever a moderately high voltage was applied across the coil. A simple model circuit simulation corroborated the analysis and further revealed that the failed insulation acted effectively as a damping resistor of $R_{d,eff}=6{\Omega}$ across the coil. This damping resistance produced a 50 ms-long voltage tail after the coil current was ramped down, making the coil not suitable for use in ULF-MR, which requires complete removal of magnetic field from $B_p$ coil within milliseconds.

3T MR Imaging에 적합한 RF Surface Coil의 개발 : 피부 미세구조에 대한 예비 연구

  • 윤성익;이정우;최보영;이형구;서태석
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.48-48
    • /
    • 2003
  • Abstract: 현대 질병의 최종진단은 세포수준의 해부형태학적 연구가 일반적이며 광학현미경이나 전자현미경을 이용한 병리조직학적 소견을 바탕으로 진단되어지고 있다. 이러한 진단에는 In vivo 검사가 거의 불가능하여 주로 생검을 통한 연구만 수행되고 있어 진단함에 있어 단계적인 불편이 초래될 뿐만 아니라 악성 종양의 전이를 유발시킬 수 있고 또한 생리 및 생화학적 분석이 어렵다. 이러한 문제점을 해결하기 위해 고분해능의 RF Surface Coil을 개발하여 In vivo 및 비침습적인 방법인 MR Technology를 이용하고자 한다. Introduction: 피부조직과 같은 미세 인체구조 연구를 위해 고해상도 3T MRI 시스템에 적합한 고분해능의 RF surface coil을 개발하고 있다. In vivo 연구를 위한 여러 parameter를 최적화하여 기능영상에도 부합된다. 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준으로 향상되어 질병의 정확한 진단이 가능해지게 될 것이다. Method: 고분해능의 RF Surface Coil을 제작하여 3T MR 장비에서 피부 미세구조연구에 보다 적합하도록 In vivo 및 In vitro 실험을 수행하였다. In vitro 실험은 In vivo 연구를 위한 여러 parameter들을 최적화하기 위한 기초 실험을 하였고 다양한 팬톰들을 이용하여 Tl 강조영상, T2 강조영상을 획득하였으며, SNR을 높이기 위한 개선에 대한 연구를 수행하였다. In vivo 실험은 정상피부에서 다양한 부위에 대한 피부영상의 예비 연구를 수행하였다. Result and Discussion: 비침습적인 In vivo 검사에 의한 세포수준의 극 미세구조의 연구가 가능해짐으로써 과거 시행하던 침습적인 생검없이 각종질환의 진단적 접근이 병리학적 수준에서 가능해짐으로써 질병의 정확한 진단이 가능해지게 될 것이다. Acknowledgement: 본 연구는 2002 년도 한국과학재단 목적기초연구사업 (과제번호 : R0l-2002-000-00294-0 (2002)) 지원아래 수행되었다.

  • PDF