Nonconstrained Blood Pressure Measurement by Photoplethysmography

  • Yoon Young-Zoon;Yoon Gil-Won
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.91-95
    • /
    • 2006
  • Blood pressure was predicted from photoplethysmography (PPG). To obtain PPG, backscattered light from a fingertip was measured and its waveform was analyzed. Systolic upstroke time and diastolic time in the pulse waveform were used as parameters to predict blood pressure. The experiment was carried out with five subjects on five different days. The systolic upstroke time had a correlation coefficient of -0.605 with respect to systolic blood pressure and the diastolic time had a correlation coefficients of -0.764 for diastolic pressure. This PPG method does not require an air-cuff installation on the arm and can predict blood pressure continuously. This simple LED/photo detector setup can be a good candidate for nonconstrained monitoring of blood pressure variations.

Blood Pressure and Heart Rate Responses to Concentric, Eccentric, Isometric Exercises (구심성, 원심성, 등척성 운동방법에 따른 혈압과 심박수의 변화)

  • Jung, Yeon-Tai;Kim, Ki-Hun;Current, Marion E.;Han, So-Young
    • Physical Therapy Korea
    • /
    • v.1 no.1
    • /
    • pp.75-82
    • /
    • 1994
  • The purpose of this study is to determine cardiovascular reponses to concentric, eccentric and isometric exercise applied to the knee extensor muscle group. Exercise types studied were concentric, eccentric and isometric. The subjects were sixty healthy male volunteers who had no hypertension or cardiac disease. Heart rate, systolic and diastolic blood pressure were recorded prior to starting exercise. The subjects also performed 10RM on right lower extremity. A N-K table was used for three exercises to right knee extensors. Each exercise was selected randomly and applied to each subject 10 times in a 10 second. After each exercise, heart rate, systolic and diastolic blood pressure were recorded immediately. Findings were as follows concectric contractions had a greater effect on the increase of systolic blood pressure and heart rate than eccentric or isometric contractions. Diastolic blood pressure is influenced only by isometric contractions. Eccentric contractions have less effect on the increase of systolic blood pressure and heart rate than concentric or isometric contractions. We hope that the results of this experiment can be adapted to exercise programs for patients with cardiac disease.

  • PDF

Verification of Reliable Blood Pressure Monitor in a Moving Ambulance during an Emergency (응급상황시 이송중인 구급차에서 신뢰할 수 있는 혈압계 검증)

  • Jeon, Jai-In
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.91-97
    • /
    • 2022
  • The purpose of this study was to analyze the measurements of blood pressure and time using manual and automatic blood pressure monitors in various road conditions to verify reliable blood pressure monitor in a moving ambulance. First, the manual blood pressure monitor palpation on unpaved roads showed a systolic pressure deviation of 5 mmHg. However, the automatic blood pressure monitor showed two measurement failures, one reading failure, and the measured systolic pressure deviation was 35 mmHg. The measurement time was 102 seconds faster on average than the automatic blood pressure monitor. Second, the palpation of the manual blood pressure monitor while going over speed bumps remained constant at 130 mmHg. However, the automatic blood pressure monitor had a systolic pressure deviation of 52 mmHg. The measurement time was 61 seconds faster on average than the automatic blood pressure monitor. Finally, the manual blood pressure monitor palpation on the sharp curve road showed a systolic pressure deviation of 5 mmHg. The automatic blood pressure monitor had one reading failure and the measured systolic pressure deviation was 21 mmHg. The measurement time showed that the manual blood pressure monitor was 101 seconds faster than the automatic blood pressure monitor. As a result, in a moving ambulance during an emergency, the manual blood pressure monitor showed high reliability because the blood pressure measurement was constant and the measurement time was short.

A Study on Correlation between Blood Pressure and Dietary Na, K Intakes Pattern in the Family Members of Normal and Cerebrovascular Disease Patients (뇌졸중 환자 가족과 정상인에 있어서 혈압과 Na, K 섭취경향간의 상관관계 연구)

  • Kim, Jong-Dai;Choe, Myeon;Ju, Jin-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.1
    • /
    • pp.24-29
    • /
    • 1995
  • Purpose of this study was to investigate correlation between blood pressure (systolic and diastolic) and dietary sodium, potassium intake pattern in the family members of normal cerebrovascular (CVA) disease, excluding patients themselves. Both mean values of systolic (125.8$\pm$23.7 vs 119.3$\pm$19.2mmHg) and diastolic(76.1$\pm$16.7 vs 71.6$\pm$12.5mmHg) bllood pressure in the family members of cerebrovascular disease patients were significantly higher than those of normal subjects. Systolic blood pressure was positively correlated with age, weibght, sodium in soybean paste, potassium in hotpepepr paste, soybean paste and meats in normal subjects group. In the family members of cerebrovascular patient, systolic blood pressure was possively correlated with age, weight, sodium in soy sauce, drinking water and potassium in soups. Interestingly, table salt intake was positively correlated with systosolic blood pressure in the family members of cerebrovascular disease patients. Diastolic bolld pressure was positively correlated with age, weight, table salt intake potassium in hotpepper paste and soybean paste in normal subjects group. Diastolic blood pressure was positively correlated with age, weight and table salt intake in the family members of cerebrovascular disease patients. Urinary potassium excretion was negatively correlated with both systolic and diastolic blood pressure in the family members of cerebrovascular disease patients.

  • PDF

The Depressive Effect of Hwa-acupuncture Treatment in Hypertension Patients (고혈압 환자에서 화침법(和針法)의 혈압강하 효과)

  • Han, Chang-Hyun;Park, Kyung-Ho;Shin, Mi-Suk;Shin, Seon-Hwa;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.23 no.6
    • /
    • pp.165-176
    • /
    • 2006
  • Objectives : Aim of this study was to investigate the antihypertensive effect of Korean Hwa-Acupuncture in hypertensive patients. Methods: We measured the blood pressure of 14 patients who were admitted in the Oriental Medical Clinic of Balance & Harmony Korean Acupuncture Association from 25th March 2006 to 21th July 2006. Eligible participants had systolic blood pressure ${\geq}120mmHg$ diastolic blood $pressure{\geq}80mmHg$. Blood pressure and pulse rate measurements were after the patient had been bed rest for at least 30 min. 10 times of Hwa-Acupuncture treatment over 3 weeks period were performed in the patiants. To evaluate the effect of the Hwa-Acupuncture, the blood pressure, pulse rate were measured 2 times before and after each acupuncture treatment for total of 10 times. Results : After 3 weeks, there were significant decreased in the systolic blood pressure(P<0.0297) and significant decreased in diastolic blood pressure(P<0.0223) treated by Hwa-Acupuncture 10 times but pulse rate was failed to decreased. The effects of Hwa-Acupuncture by measuring time on blood pressure were as follows : systolic blood pressure were deceased significantly from 1st to 10th visit (P<0.0207) but diastolic blood pressure and pulse rate was not decreased significantly. Conclusion : The results suggest that Hwa-Acupuncture is effective in decreasing the systolic blood pressure.

  • PDF

Automatic blood pressure measurement device using oscillometric method and Korotkoff sounds

  • Wei, Ran;Lim, Young Chul;Im, Jae Joong
    • International journal of advanced smart convergence
    • /
    • v.1 no.2
    • /
    • pp.20-25
    • /
    • 2012
  • The oscillometric method and Korotkoff sound method are the most common ways to measure the blood pressure. A new automatic blood pressure measurement device, which uses both oscillometric method and Korotkoff method, was developed. A pressure sensor was used to obtain cuff pressure and oscillation signal, and a microphone was used to detect Korotkoff sounds. Forty-five measurements from fifteen subjects were used for analysis. Correlation coefficients between the traditional auscultatory method and Korotkoff sound method were 0.9820 and 0.9721 for the systolic and diastolic blood pressure values, respectively. Standard deviations of differences for the systolic and diastolic blood pressure values were 1.3019 and 1.4495, respectively. Correspondingly, correlation coefficients between the traditional auscultatory method and oscillometric method using newly developed algorithm were 0.9651 and 0.9136 for the systolic and diastolic blood pressure values, with the standard deviations of 1.42 and 1.73, respectively. The results showed that the newly developed algorithm for oscillometirc method provide accurate blood pressure values, moreover, Korotkoff sound method using microphone provides even higher accuracy. Therefore, a new automatic device which utilizes both oscillometric method and Korotkoff sound method would provide the accurate and reliable blood pressure values.

The Antihypertensive Effect of Gyeok pal sang saeng yeok chim Acupuncture Treatment in Hypertension Patients (고혈압 환자에서 격팔상생역침범(隔八相生易鐵法)의 혈압강하 효과)

  • Han, Chang-Hyun;Han, Choong-Hee;Shin, Mi-Suk;Shin, Seon-Hwa;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.23 no.4
    • /
    • pp.49-60
    • /
    • 2006
  • Objectives : The aim of the study was to investigate the antihypertensive effect of Gyeok pal sang saeng Yeok chim Acupuncture in hypertensive patients. Methods : We measured the blood pressure of the patients who were admitted in the Oriental Medical Clinic of Brother from 13th February 2006 to 13th May 2006. We included the patients only in case of the systolic blood pressure was over 120mmHg or diastolic blood pressure was over 80mmHg, thirty patients were treated by Gyeok pal sang saeng Yeok chim Acupuncture. In order to evaluate the effect of the Gyeok pal sang saeng Yeok chim Acupuncture, the blood pressure and pulse rate were measured before and after Acupuncture procedure total 10 times. Results : There were significant decrease in the systolic blood pressure and significant decrease in the diastolic blood pressure treated by Gyeok pal sang saeng Yeok chim Acupuncture 10 times but pulse rate was not significantly decreased. The effect of Gyeok pal sang saeng Yeok chim Acupuncture by measurement time on blood pressure were follows: In a systolic blood pressure and diastolic blood pressure was gradually deceased significantly from 1st to 10th but pulse rate was not significantly decreased. Conclusion : These results suggest that Gyeok pal sang saeng Yeok chim Acupuncture is effective in decreasing the systolic and diastolic blood pressure.

  • PDF

Effectiveness of Hwang-gu acupuncture treatment in hypertension patients; case report (황구침법(黃丘鍼法)을 이용한 고혈압 환자의 혈압강하 효과에 대한 증례보고)

  • Han, Chang-Hyun;Hwang, Chi-Won;Shin, Mi-Suk;Shin, Seon-Hwa;Choi, Sun-Mi
    • Korean Journal of Acupuncture
    • /
    • v.23 no.3
    • /
    • pp.37-50
    • /
    • 2006
  • Objectives : The aim of the study was to investigate the antihypertensive effect of Hwang-gu Acupuncture in hypertensive patients. Methods : We measured the blood pressure of the patients who were admitted in the Oriental Medical Clinic of Brother from 25th November 2005 to 27th March 2006. We included the patients only in case of the systolic blood pressure was over 140mmHg or diastolic blood pressure was over 90mmHg, Twenty two patients were treated by Hwang-gu Acupuncture. In order to evaluate the effect of the Hwang-gu Acupuncture, the blood pressure was measured before and after Acupuncture procedure total 4 times, 10times. Results : There were a significant decrease in the systolic blood pressure and significant decrease in the diastolic blood pressure by Hwang-gu Acupuncture 4 times. The effect of Hwang-gu Acupuncture by measurement time on blood pressure were follows: In a systolic blood pressure was gradually deceased significantly from 1st to 4th but diastolic blood pressure was significantly decreased after 2nd and 4th only. Conclusions : These results suggest that Hwang-gu Acupuncture is effective in decreasing the systolic and diastolic blood pressure.

  • PDF

Estimation of Systolic Blood Pressure using PTTL (PTTL을 이용한 수축기 혈압추정)

  • Kil, Se-Kee;Kwan, Jang-Woo;Yoon, Kwang-Sub;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1095-1101
    • /
    • 2008
  • The desirable method to diagnose abnormal blood pressure is to measure and manage blood pressure continuously and regularly. However, the sphygmomanometers that are based on a cuff have faults in that they can not measure the blood pressure continuously and they cause an unpleasant feeling. Therefore, it is essential to develop a new measuring method that causes no pain and that can obtain blood pressure continuously without any unpleasant feeling. Thus, we propose here a regression method to estimate the systolic blood pressure by using the PTTL(pulse transit time on leg) with some body parameters which are chosen from the relational analysis with systolic blood pressure. The data we use to make the regression model were obtained in triplicate from each of 50 males who were from 18 to 35 years. And we made estimation experiments of blood pressure on 10 males who did not take part in the making the regression model. According to the results, the proposed method showed a mean error of 4.00 mmHg and the standard variance was 2.45 mmHg. When we comparing the results of the proposed method with the rule of American National Standards Institute of the Association of the Advancement of Medical Instruments(ANSI/AAMI), the results satisfied the rule of a mean error less than 5 mmHg and a standard variance less than 8 mmHg. Therefore we were able to validate the usefulness of the proposed method.

A Comparative Study of Blood Pressure According to Cuff Size and Measurement Site (커프크기와 측정부위에 따른 혈압측정치 비교 연구)

  • Song, Mi-Ryeong;Kim, Eun-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.16 no.1
    • /
    • pp.6-13
    • /
    • 2009
  • Purpose: The purpose of this study was to identify differences in blood pressure according to cuff size and measurement sites of the participants. Method: The participants consisted of 50 women and 50 men whose upper arm circumference was $26\sim30cm$. They had no chronic illness and gave consent to participate. Blood pressure of the wrist was measured in the sitting position, the upper arm with a standard cuff, large and small cuffs were used for measurement in supine position and the thigh in prone position. The data were analyzed with paired t-test using SPSS 12.0 program. Result: The data for the upper arm showed a difference in systolic and diastolic blood pressure depending on the site of measurement. There was a significant difference between measurements with a standard cuff and measurements with large and small cuffs. The systolic blood pressure of the wrist and the thigh were significantly lower than that of the upper arm. Conclusion: These results suggest that the selection of an appropriate cuff is an essential element in ensuring accuracy when measuring blood pressure and differences in systolic blood pressure for the upper arm, wrist and thigh indicate the need to record the measuring site when measuring blood pressure.

  • PDF