• Title/Summary/Keyword: SystemC

Search Result 26,370, Processing Time 0.05 seconds

A study on Software Reuse System Using Reverse Engineering (역공학을 이용한 소프트웨어 재사용 시스템에 관한 연구)

  • Choe, Eun-Man
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.1
    • /
    • pp.97-106
    • /
    • 1997
  • Software reuse techniques make reapplication of various well-organized information knowledge to system development so that improve productivity and make it easy to maintain software. This paper describes the design and implementation of CSORUS(C and C++ SOurce ReUse System) which can extract reuse components using reverse engineering, and store, retrieve, merge them written with C of C++ programming language. The construction components using reverse engineering has advantage in quality assurance because they are reliable components already tested in real environments.

  • PDF

Development of Reliability Evaluation System for I&C System Upgrade (원자력발전소 I&C계통 설비개선을 위한 평가시스템 개발)

  • Chung, Hak-Young;Kang, Hyeon-Tae;Sung, Chan-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1852-1858
    • /
    • 2007
  • To Increase availability and to enhance the safety, the modernization of Instrumentation & Control (I&C) systems is considered. The extended use of the digital technology lets nuclear power plants(NPPs) to replace their old analog systems with some proven digital systems. To adapt digital equipment to plants effectively and systematically, however, there must be an essential prerequisite, which is to evaluate current I&C equipment. This paper shows a practical methodology to evaluate the current status and reliability of I&C systems of NPPs using Reliability Evaluation System(RES) before performing upgrades or replacements for systems. The proposed method was applied to KORI Unit 2. The proposed method shows the current status of operating I&C systems effectively for upgrading I&C systems.

A Study on the Analysis of Combat Effectiveness of the Army C2A System (육군 방공자동화체계 전투효과 분석에 관한 연구)

  • Choi Woo-Chan;Lee Jea-Young
    • Journal of the military operations research society of Korea
    • /
    • v.30 no.2
    • /
    • pp.63-80
    • /
    • 2004
  • This paper develops a methodology which can be used to quantify the combat effectiveness of the army C2A system by modifying C2 theory and using Air Defense Engagement Simulation. In this paper, by using Schutzer's C2 theory and Measures of Effectiveness, we modified the MOE formula he designed. Because the combat effectiveness by enhancement of C2(Command and Control) system will increase combat power of individual asset independently. In addition, we developed simulation analysis of air defense scenario by using Air Defense Engagement Simulation. The results show that modified the MOE formula is proper as compared with Air Defense Engagement Simulation method. The combat effectiveness can be obtained as a result of improved probability of detection and information accuracy through real-time information sharing and coordination by C2A system.

Thermal Energy Characteristics for Greenhouse Heating System with Far-Infrared Heater (원적외선 면상발열체에 의한 온실 난방시스템의 열특성 분석)

  • Ro, J.G.;Kim, H.J.;Li, H.;Han, C.S.;Cho, S.C.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.6 s.119
    • /
    • pp.529-534
    • /
    • 2006
  • The greenhouse heating system with far-infrared heater was built to analyze various thermal characteristics, such as greenhouse air temperature, soil temperature, energy flow, energy consumption in far-infrared heater, and other factors, which could be used in comparison with other greenhouse heating system in this study. The results showed that the inside air temperature of the far-infrared greenhouse heating system was $5^{\circ}C$ higher than that of hot air heating system. Heat loss of daytime was found to be larger than that of night time as much as 44.8% for the heating system with far-infrared heater. In the heating system with far-Infrared heater, when the lowest ambient temperature was -8 $\sim$ -7$^{\circ}C$, the air temperature of greenhouse was 12 $\sim$ 15$^{\circ}C$, thus the far-infrared heating system was shown to be feasible for heating system. Energy consumption of far-infrared heating system was shown to be less than that of hot air heating system.

Digital Asset Analysis Methodology against Cyber Threat to Instrumentation and Control System in Nuclear Power Plants (원자력발전소의 디지털계측제어시스템의 사이버보안을 위한 디지털 자산분석 방법)

  • Koo, In-Soo;Kim, Kwan-Woong;Hong, Seok-Boong;Park, Geun-Ok;Park, Jae-Yoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.6
    • /
    • pp.839-847
    • /
    • 2011
  • Instrumentation & Control(I&C) System in NPP(Nuclear Power Plant) plays a important role as the brain of human being, it performs protecting, controling and monitoring safety operation of NPP. Recently, the I&C system is digitalized as digital technology such as PLC, DSP, FPGA. The different aspect of digital system which use digital communication to analog system is that it has potential vulnerability to cyber threat in nature. Possibility that digital I&C system is defected by cyber attack is increasing day by day. The result of cyber attack can be adverse effect to safety function in NPP. Therefore, I&C system required cyber security counter-measures that protect themselves from cyber threat efficiently and also cyber security design should be taken into consideration at concept stage in I&C system development process. In this study, we proposed the digital asset analysis method for cyber security assessment of I&C system design in NPP and we performed digital asset analysis of I&C system by using the proposed method.

A Design of Main Control Unit in CRCS/CEDMCS (원자로 제어봉구동장치제어시스템 주제어부 설계)

  • Cheon, Jong-Min;Lee, Jong-Moo;Kim, Choon-Kyoung;Kwon, Soon-Man;Shin, Jong-Ryeol
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.559-561
    • /
    • 2004
  • In this paper, we design two types of Main Control Unit for Control Rod Control System and Control Element Drive Mechanism Control System, respectively, using a domestic Distributed Control System(DCS) developed to localize the instrumentation and control(I&C) system for nuclear power plant(NPP). There are many parts developed by domestic skills and being operated successfully in NPP, but the development of I&C system as an essential part has been slow in progress. We will show the great possibility of developing peculiar Korean I&C system by applying this domestic DCS to nuclear I&C system and confirming its successful operation.

  • PDF

Geothermal Effects on the Underground Water Conveyance Pipe System from Han River (한강수계 광역상수도 원수관의 지열 영향 조사)

  • Cho, Yong;Park, Jin-Hoon;Park, Tae Jin;Kim, Youngjoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.171.2-171.2
    • /
    • 2010
  • Geothermal effects on the underground water conveyance pipe system have been investigated through the multiregional water supply system from Paldang water intake station. To make an investigation of raw water thermal energy, temperature sensors are installed the surface of the pipes of metropolitan area water supply system. In 2009 winter and early spring seasons, the monthly averaged temperatures at Paldang 2 intake stations are $1.94^{\circ}C$ in February, $4.96^{\circ}C$ in March, and $10.56^{\circ}C$ in April. After the transfer in 26.0 km distance of tunnel and buried pipe, the raw water temperatures are raised to $3.13^{\circ}C$, $6.04^{\circ}C$, and $11.39^{\circ}C$ respectively. As the temperature difference between the raw water and the air reduces, the temperature increasement is reduced by $1.19^{\circ}C$ in Feb., $1.08^{\circ}C$ in Mar., and $0.83^{\circ}C$ in Apr. Since the flowrate is over 1,150,000 $m^3$/day, it is estimated that the water exchanges a huge amount of heat over 1.0 Tcal a day with the ground.

  • PDF

Studies on the Biological Function and Antibacterial Effect of Lactoperoxidase System in Raw Milk 2. Antibacterial Effect of Lactoperoxidase System Against Listeria monocytogenes (우유내의 LP system의 생리기능 및 항균성에 관한 연구 2. Listeria monocytogenes에 대한 항균효과)

  • 정충일;남은숙;김대원;이원창;정동관
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.2
    • /
    • pp.83-86
    • /
    • 1998
  • This study was carried out to measure the antibacterial effect of lactoperoxidase system against L. monocytogenes. When the initial inoculum levels ($10^{2},\;10^{4},\;10^{7}\;CFU/ml$), concentration of LP (10 ppm, 20 ppm, 30 ppm), culture media (TSB-YE, UHT milk) and storage temperatures ($5^{\circ}C,\;10^{\circ}C,\;15^{\circ}C$) were set up differently for the experiment and the antibacterial effect was compared, the highest antibacterial effect of LP system was shown at $10^{2}\;cfu/ml$ of initial inoculum level, 10 ppm of LP concentration and $5^{\circ}C$ of incubaction temperature. The antibacterial effect of LPS in UHT milk was similar to that in Tryptic soy broth.

  • PDF

C2JNI: An Embedded C to JNI Translator (C2JNI: 내장 C 언어에서 JNI 코드를 생성하는 변환기)

  • 유재우;최종명;김영철
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.11
    • /
    • pp.1551-1559
    • /
    • 2004
  • Java, a platform independent object-oriented programming language, is widely used, however it should be integrated with JNI to use system services or to reuse legacy systems. Though JNI provides the standard APIs which allow Java to be combined with C/$C^{++}$, it is very hard and cumbersome for developers to use JNI APIs. In order to address this problem, we introduce a translator named C2JNI, which converts the embedded C program into a JNI compatible C program. With C2JNI, developers can Integrate Java and C programs without JNI APIs, and it will reduce the complexity caused by JNI APIs.

Selective chemical vapor deposition of $\beta$-SiC on Si substrate using hexamethyldisilane/HCl/$H_{2}$ gas system (Hexamethyldisilane/HCl/$H_{2}$ gas system을 이용한 Si 기판에서 $\beta$-SiC의 선택적 화학기상증착)

  • 양원재;김성진;정용선;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.1
    • /
    • pp.14-19
    • /
    • 1999
  • Using a single precursor of hexamethyldisilane $(Si_{2}(CH_{3})_{6})$, $\beta$-SiC film was successfully deposited on a Si substrate at $1100^{\circ}C$ by a chemical vapor deposition method. Selectivity of SiC deposition on a Si substrate partially covered with a masking material was investigated by introducing HCl gas into hexamethyldisilane/$H_{2}$ gas system during the deposition. The schedule of the precursor and HCl gas flows was modified so that the selectivity of SiC deposition between a Si substrate and a mask material should be improved. It was confirmed that the selectivity of SiC deposition was improved by introducing HCl gas. Also, the pulse gas flow technique was effective to enhance the selectivity.

  • PDF