• 제목/요약/키워드: System-Level Simulator

검색결과 276건 처리시간 0.029초

Collaboration to Enhance Development and Application of Shiphandling Simulators

  • Shi, Chaojian;Chen, Jinbiao;Xiao, Baojia;Ding, Baocheng
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.1
    • /
    • pp.459-464
    • /
    • 2006
  • It has been well proved that shiphandling simulators are efficient and useful facilities for training and education of cadets and seafarers. Most of the maritime universities and many maritime training institutes all over the world have installed shiphandling simulators, which play important roles in maritime education and training. However, most of the Shiphandling simulators are standalone facilities with diversities on system architectures, layouts and functions. STCW78/95 requires simulators used for simulator-based training shall be suitable for the selected objectives and training tasks. To ensure the shiphandling simulator facilities meet the requirements of STCW convention and other expanded applications, collaborated research and coordination are needed in development and application of shiphandling simulators. Performance standard should be established for shiphandling simulator systems considering the advanced research needs as well as the needs in education, training, and assessment of competence. Standardizing and exchanging shiphandling mathematical models will improve critical performance of the system. Cooperated research on model course and training assessment approaches will enhance the training standard. In addition, the rapid spread of the internet technology has shown a promising future of application of shiphandling simulators through internet. Research has been carried out on internet based integration of multiple shiphandling simulators. A multi-agent based system, including necessary hardware, has been developed. Collaborated operation of the system can be of benefit in filling the gaps of the technical and operational level and methodology between maritime universities, enhancing mutual understanding of the navigation customs and culture background among cadets and seafarers from different countries, facilitating communication and maritime English training, and extending the functions of shiphandling simulators.

  • PDF

논리회로 설계 자동화를 위한 시뮬레이션 시스템 (A Simulation System for the Automation of Logic Circuit Design)

  • 한창호
    • 한국시뮬레이션학회논문지
    • /
    • 제3권1호
    • /
    • pp.107-114
    • /
    • 1994
  • This paper describes an integrated environment for logic circuit simultion which is an important step of logic circuit design. The system consists of a logic simulator kernel, an expandible element routine library. a functional level element routine generator, several HDL input parsers, and a postprocessor. The system can simulate the same system in several levels of hierarchy. The experimental result shows that the system is very efficient and useful for design of logic circuits.

  • PDF

A control of wound-rotor induction generator for random wave input generation system

  • Kim, Moon-Hwan
    • Journal of information and communication convergence engineering
    • /
    • 제5권3호
    • /
    • pp.223-228
    • /
    • 2007
  • This paper deals with the secondary excited induction generator applied to random wave input generation system. As it is preferred to stabilize the output voltage and frequency in the constant level, microcomputer controlled CSI connected to the secondary windings supplies the secondary current with slip frequency. For testing this method, the input torque simulator is constructed, according to the power flow analysis. The experimental and numerical results show the advantage of secondary excited induction generator system for the random input wave generation system.

Spartan-3 FPGA를 이용한 ECG 시뮬레이터 설계 (ECG simulator design with Spartan-3 FPGA)

  • 우성희;이원표;류근택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.834-837
    • /
    • 2015
  • 본 논문은 0-5 볼트의 범위에서 실시간 아날로그 ECG 신호를 생성하는 FPGA 하드웨어 기반 ECG 시뮬레이터를 설계하고 기능 및 특성을 기술하였다. 시뮬레이터에 의해 생성된 ECG 신호는 실험실 실험, 의료 기기 교정 및 연구에 사용되거나 다양하게 응용할 수 있다. 시뮬레이터의 ECG 신호는 신호 데이터를 생성하기 위하여 기존의 24bit 양자화로 획득한 후 실 데이터로 사용할 때에는 1kHz의 샘플링과 8비트로 분해, 양자화 되었다. 제안 시뮬레이터는 xilix Spartan-3를 이용하여 구현하였으며 PC와 설계 FPGA 시뮬레이터 간에 RS-232를 통하여 데이터를 전송할 수 있도록 하였다. 전송된 데이터는 메모리에 저장하고 저장된 데이터는 DAC(0808) 통하여 아날로그 ECG 신호로 출력되게 하였다. 또한 두 개의 버튼 수위를 통하여 심박수(HR)를 UP-DOWN할 수 있도록 하였다. 설계된 시스템의 평가를 위하여 기존의 심전도 입력을 사용하여 출력신호와 QRS파형의 획득을 위한 미분회로 통과 결과를 평가한 결과 적합한 결과를 얻을 수 있었다.

  • PDF

고정익 유/무인기의 협업 모의를 위한 원격공중통제 시뮬레이터 개발 및 활용방안 (Development and Application of Remote Airborne Control Simulator for Experimentation of Manned-Unmanned Teaming of Fixed Wing UAV)

  • 최영미
    • 항공우주시스템공학회지
    • /
    • 제15권1호
    • /
    • pp.56-62
    • /
    • 2021
  • 본 논문은 고정익 유·무인기 협업을 모의하는 원격공중통제 시뮬레이터에 관하여 기술한다. 무인기의 급격한 기술개발을 통해 무인기의 임무 능력은 크게 성장하였다. 무인기의 역할은 단순 정찰 임무에서 부터 전자전, 근접 공중 지원, 유·무인 협업과 같은 복합 임무까지 수행할 수 있도록 발전하고 있다. 이에, 지상에서 이러한 복합 임무를 모의할 수 있는 환경에 대한 개발 요구가 커지고 있다. 원격공중통제 시뮬레이터는 고정익 유·무인기 협업 기술 개발을 위해 지상에서 유·무인 협업 임무모의 수행을 위하여 개발되었다. 최신의 유·무인 협업 연구 사례와 더불어 원격공중통제 시뮬레이터의 무인기 임무 수행 모의 환경 활용과 적용에 대하여 기술하고자한다.

Choice of Efficient Sampling Rate for GNSS Signal Generation Simulators

  • Jinseon Son;Young-Jin Song;Subin Lee;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권3호
    • /
    • pp.237-244
    • /
    • 2023
  • A signal generation simulator is an economical and useful solution in Global Navigation Satellite System (GNSS) receiver design and testing. A software-defined radio approach is widely used both in receivers and simulators, and its flexible structure to adopt to new signals is ideally suited to the testing of a receiver and signal processing algorithm in the signal design phase of a new satellite-based navigation system before the deployment of satellites in space. The generation of highly accurate delayed sampled codes is essential for generating signals in the simulator, where its sampling rate should be chosen to satisfy constraints such as Nyquist criteria and integer and non-commensurate properties in order not to cause any distortion of original signals. A high sampling rate increases the accuracy of code delay, but decreases the computational efficiency as well, and vice versa. Therefore, the selected sampling rate should be as low as possible while maintaining a certain level of code delay accuracy. This paper presents the lower limits of the sampling rate for GNSS signal generation simulators. In the simulation, two distinct code generation methods depending on the sampling position are evaluated in terms of accuracy versus computational efficiency to show the lower limit of the sampling rate for several GNSS signals.

Development of KOMPSAT-2 Vehicle Dynamic Simulator for Attitude Control Subsystem Functional Verification

  • Suk, Byong-Suk;Lyou, Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1465-1469
    • /
    • 2003
  • In general satellite verification process, the AOCS (Attitude & Orbit Control Subsystem) should be verified through several kinds of verification test which can be divided into two major category like FBT (Fixed Bed Test) and polarity test. And each test performed in different levels such as ETB (Electrical Test Bed) and satellite level. The test method of FBT is to simulate satellite dynamics with sensors and actuators supported by necessary environmental models in ETB level. The VDS (Vehicle Dynamic Simulator) try to make the real situation as possible as the on-board processor will undergo after launch. The purpose of FBT test is to verify that attitude control logic function and hardware interface is designed as expected with closed loop simulation. The VDS is one of major equipments for performing FBT and consists of software and hardware parts. The VDS operates in VME environments with target board, several commercial boards and custom boards based on the VxWorks real time operating system. In order to make time synchronization between VDS and satellite on-board processor, high reliable semaphore was implemented to make synchronization with the interrupt signal from on-board processor. In this paper, the real-time operating environment used on VDS equipment is introduced, and the hardware and software configurations of VDS summarized in the systematic point of view. Also, we try to figure out the operational concept of VDS and AOCS verification test method with close-loop simulation.

  • PDF

광대역 CDMA 셀룰러 표준을 위한 시스템 수준 시뮬레이터의 설계 방법론 (Design Methodology of System-Level Simulators for Wideband CDMA Cellular Standards)

  • 박성경
    • 한국시뮬레이션학회논문지
    • /
    • 제22권1호
    • /
    • pp.41-51
    • /
    • 2013
  • 이 논문에서는 EV-DO나 브로드캐스트 멀티캐스트 서비스와 같은 CDMA 셀룰러 표준을 목표로 하는 시스템 수준 시뮬레이터의 설계 방법론을 소개한다. 셀 레이아웃, 모바일 분포, 채널 모델링, 수신 전력 계산, 스케줄링, 패킷 에러 예측, 트래픽 생성 등의 절차를 따라 가면서, 시스템 수준 시뮬레이터의 기본 구조와 시뮬레이션 흐름을 기술하였다. 시뮬레이터를 모델링하기 위해, CDMA 시스템과 EV-DO 방송 시스템의 순방향 링크에서의 패킷 데이터 전송을 고려하였다. 셀룰러 표준을 위한 시스템 수준 시뮬레이터는 상위 수준 언어로 모델링 및 개발 되었고, 용량과 커버리지를 포함한 에어 접속부 성능 지표들을 계산 및 예측하는 데에 이용되었다.

Acceptance Test and Clinical Commissioning of CT Simulator

  • An, Hyun Joon;Son, Jaeman;Jin, Hyeongmin;Sung, Jiwon;Chun, Minsoo
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.160-166
    • /
    • 2019
  • This study examined the clinical use of two newly installed computed tomography (CT) simulators in the Department of Radiation Oncology. The accreditation procedure was performed by the Korean Institute for Accreditation of Medical Imaging. An Xi R/F dosimeter was used to measure the CT dose index for each plug of the CT dose index phantom. Image qualities such as the Hounsfield unit (HU) value of water, noise level, homogeneity, existence of artifacts, spatial resolution, contrast, and slice thickness were evaluated by scanning a CT performance phantom. All test items were evaluated as to whether they were within the required tolerance level. CT calibration curves-the relationship between CT number and relative electron density-were obtained for dose calculations in the treatment planning system. The positional accuracy of the lasers was also evaluated. The volume CT dose indices for the head phantom were 22.26 mGy and 23.70 mGy, and those for body phantom were 12.30 mGy and 12.99 mGy for the first and second CT simulators, respectively. HU accuracy, noise, and homogeneity for the first CT simulator were -0.2 HU, 4.9 HU, and 0.69 HU, respectively, while those for second CT simulator were 1.9 HU, 4.9 HU, and 0.70 HU, respectively. Five air-filled holes with a diameter of 1.00 mm were used for assessment of spatial resolution and a low contrast object with a diameter of 6.4 mm was clearly discernible by both CT scanners. Both CT simulators exhibited comparable performance and are acceptable for clinical use.