• Title/Summary/Keyword: System analyzer

Search Result 1,147, Processing Time 0.03 seconds

A Protocol Analyzer for SW based Multimedia Communication System (SIP 기반 멀티미디어 통신 시스템을 위한 프로토콜 분석기)

  • Jung In-hwan
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.11 no.4
    • /
    • pp.312-333
    • /
    • 2005
  • SIP(Session Initiation Protocol) has been proposed for session control protocol of Internet multimedia communication system like VoIP(Voice over IP). SIP has complicated session control steps to support various kinds of audio and video formats and to assure service quality of real time data communication. Up until now, existing protocol analyzers can not provide such detailed information of SIP based communication system. In this paper, therefore, we propose a new protocol analyzer as a tool that can analyze and diagnose SIP based multimedia communication system throughout the session initiation, data exchange and session change steps. The propose traffic analyzer, which is called STAT(SIP based Traffic Analysis Tool), Is implemented on Winder's environment so that it is generally usable and extensible. Since STAT analyze low level packets captured via Ethernet broadcasting property, it is able to provide session status and real time traffic monitoring information without any affection to the communication system. The STAT which is implemented in this paper. therefore, is expected to be a useful tool for developing and managing of a SIP based multimedia communication system.

A Study of LLVM-based Embedded System Performance Analyzer (LLVM 기반의 임베디드 시스템 성능 분석기의 연구)

  • Cho, Doosan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.577-582
    • /
    • 2022
  • For developing a new embedded system, an application program/an emulator and a compiler are developed simultaneously. In order to provide the optimal performance of all system components, local optimization should be carried out for the developing process. For this purpose, if a source-level performance analyzer is developed, it is possible to optimize the application program's source code by the performance evaluation. In general, the performance of an application program is determined in the loop iterations. The Intermediate Representation (IR) code generator generates IR code from the source code, and evaluates the execution time with the instructions in the intermediate representation code. If the source code is improved based on the evaluated result, better results can be obtained in the final application code. This study describes the source-level performance analyzer that can be used during the simultaneous development of the new embedded system and its application programs. The performance analyzer makes it possible to more quickly optimize the performance of the new embedded system.

Development of Protocol Analyzer Suited for Maintenance of LonWorks Netwo가 for Safety Management of Underground Facilities (지하시설의 안전관리를 위한 LonWorks 네트워크의 유지보수에 적합한 프로토콜 분석기의 개발)

  • Kim, Hyung-Ki;Choi, Gi-Sang;Choi, Gi-Heung
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.203-209
    • /
    • 2010
  • A compact ANSI/EIA 709.1 protocol analyzer system suited for maintenance of LonWorks network for safety management of underground facilities was developed and tested. The hardware is based on the TMS320LF2406A embedded system, and the software was designed using Visual C++6.0 under Windows XP environment. Connected to the LonWorks network the developed protocol analyzer decodes the raw packets and pass them to the master PC through USB port. Then on the PC the packets are processed and analyzed in various aspects and the key features that are essential to the maintenance of LonWorks network installed at underground facilities are displayed in a user-friendly format. Performance of the developed protocol analyzer was evaluated through a series of experiments, by measuring the speed of packet analysis and the error rate. The protocol analyzer proved to work reliably even under the increased bandwidth. However, more comprehensive tests under various underground environmental conditions are desired.

Real-Time Harmonic Parameters Analyzer for Evaluating Induction Motor Drive System (유도전동기 구동시스템 평가를 위한 실시간 고조피 파라미터 분석장치)

  • Lim, Young-Cheol;Jung, Young-Gook
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.479-483
    • /
    • 1997
  • In general, motor parameters can be divided into mechanical/electrical parameters and harmonic parameters. Mechanical/electrical parameters identification of motor have been studying systematically for a long time. But, systematical study on harmonic parameters analysis for efficient motor drive system are very poor. The goal of this paper is to propose analyzing method of harmonic parameters for motor drive system with various experimental graphic screens and numerical results and to develope harmonic parameters analyzer. A developed analyzer is made up 586-PC and DSP (digital signal processor) board, motor drive system, power and harmonic parameters analyzing software for windows. Harmonic parameters are analyzed using correlation signal processing techniques based on the correlation between voltage and current waveforms. Analysis results are visualized by 3-D current coordinates, and it is compared and evaluated with conventional time/frequency domain. To verify the validity of the proposed system, 1/4HP capacitor run type single phase induction motor and thyristor speed controller is used for analyzing. Harmonic parameters of motor drive system is analyzed and verified, with varying fire angle of thyristor speed controller, and the proposed approach is to confirm validity.

  • PDF

Development of a Data Bus Analyzer for Avionics Interfaces of Various Types (다종 항공전자 인터페이스를 위한 데이터 버스 분석 장비 개발)

  • Kim, Min-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.9
    • /
    • pp.825-832
    • /
    • 2016
  • This paper describes the development of a data bus analyzer for use in avionics systems integration test. The data bus analyzer is equipped with MIL-STD-1553B, CAN and Ethernet interface cards which is incorporated in a majority of the avionics systems to accommodate a variety of interfaces. It has an individual hardware for a capture engine and a analyzing engine in order to perform the collection and the analysis of the bus data at the same time efficiently. It provides a data display function of the grid, 2-dimensional and 3-dimensional form to increase the data analysis efficiency. Verification of the data bus analyzer was carried out module unit testing and inter-module integration testing on the basis of the test procedures. Verification of interlocking requirement and usefulness of developed equipment was confirmed through an integration test result performed on a system integration laboratory of aircraft which is an actual testing environment.

ZEUS Co. Ltd

  • 강신국
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.50-50
    • /
    • 2000
  • 당사는 1970년 제우스 콤 상사로부터 출발하여 1988년 12우러 주식회사 제우스로 법인 전환한 후 현재 한국반도체 산업협회 및 회원으로 등록 활동하고 있다. 이번 발표에서는 회사에 대한 소개와 함께 취급품목을 설명하고자 한다. 취급품목은 Ion beam sources(CSC), E-beam evaporator & E-beam source(Temescal), Residual Gas Analyzer(SPECTRA), Cryopump & Waterpump(CTI-Cryogenics), Thickness Monitor & Controller, Electrical Feedthrough, RTP system, Thin Film Analyzer, PECVD, RIE 등이다.

  • PDF

Development of a Human Motion Analyzer (인체 동작 분석기의 개발)

  • 김민기;김성호
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.217-222
    • /
    • 1995
  • We propose some applications of image processing techniques to extract quantitative measurements by using a camera system developed in Korea university and Catholic Medical School. From now on the system will be called as KCMOTION. The purpose of this study is to provide basic kinematic and kinetic data for the analysis of human movements and to find the clinical usefulness and reliability of the proposed motion analysis system. Two tests, sit-to-stand (STS) movements and pendulum test, are conducted by the system. The aims of the tests are to identify variability and reliability of KCMOTION to give some quantitative comparisons to the other systems. The result of STS movement are compared to the LOCUS IIID motion analyzer by the ratio of maximum flexion movement per body weight to the actual maximum flexion extension torque per body weight. That result in 29 % and 33 % for hip and knee joint, respectively in KCMOTION and 27 % and 30 % in LOCUS IIID System. The results of the pendulum movements are compared to that of using Cybex and Electrogoniometer with relaxation index, amplitude ratio, swing number and swing time. The results of relaxation index and amplitude ratio of the KCMOTION are between those of the Cybex and Electrogoniometer. We also observed that the KCMOTION detect more natural movement, from the results of swing number and time.

  • PDF

Mixed-mode S-parameter Measurement System of Twisted Pairs (연선의 혼합 모드 산란 계수 측정 시스템)

  • Ahn, Jungsik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.888-894
    • /
    • 2018
  • In this paper, we proposed a mixed-mode s-parameter measurement system for measuring the performance of twisted pairs. A twisted pair is a balanced type component, its characteristics can not be directly measured using network analyzer, which is generally implemented as a unbalanced type. It is possible to convert between balanced signal and unbalanced signal by using a balun but it restricts the frequency range of the measurement system. The proposed system measures the performance of twisted pairs by measuring mixed-mode s-parameters using a 4-port vector network analyzer and a designed fixture, without using a balun. We measured the performance of a commercial Ethernet cable and compared with the results which measured by using baluns. The results showed that the proposed system is capable of measuring the performance of twisted pairs.

Implementation of 4-Channel Electrolyte Analyzer using ISFET Microsensors (ISFET 마이크로센서를 이용한 4-채널 전해질 분석기의 구현)

  • Bae, S.K.;Kim, K.Y.;Won, C.H.;Cho, B.W.;Kim, C.S.;Sohn, B.K.;Cho, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.22-26
    • /
    • 1996
  • In this paper, we designed 4-channel electrolyte analyzer that can measure simultaneousely the 4 electrolytes - pH, $pNa^{+}$, $pCa^{2+}$, and $pK^{+}-$ using 2-point calibration and implemented it. Developed electrolyte analyzer consists of singal processing part, actuator part and control unit for sample flow system. To implement reliable instrument, design considerations are emphasized on flow system and sample chamber that requires small sample volume and prevent air contact with sample solution. In addition to the hardware design, we developed system software which controls full measuring process. After system developed, we verified the system performance by the test measurement for pH, $pNa^{+}$, $pCa^{2+}$, and $pK^{+}$ value.

  • PDF

Design and Fabrication of a LabView Based Partial Discharge Analyzer (LabView 기반 부분방전 분석장치의 설계 및 제작)

  • Cha, Hyeon-Kyu;Lee, Jung-Yoon;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.3
    • /
    • pp.229-235
    • /
    • 2012
  • This paper dealt with the fabrication of a partial discharge (PD) analyzer for insulation diagnosis of power facilities like transformers, cables and gas-insulated switchgears. An analytic algorithm for the phase (${\phi}$), the magnitude (q), and the pulse count (n) of PD pulse was designed and a time-frequency (TF) map algorithm was applied in the system to eliminate noises by analyzing the time and the frequency component of signals. All the algorithms were operated by a LabView graphical program. The detection circuit consists of a coupling capacitor, a detection impedance, and a low noise amplifier. A plane-plane and a point-plane electrode system were fabricated to simulate different types of insulation defects. In the experiment, we could easily understand the characteristics of PD pulses using the prototype PD analyzer.