• Title/Summary/Keyword: System Parameter

Search Result 6,813, Processing Time 0.05 seconds

Database Management System Parameter Tuning Processes for Improving Database System Performance (데이터베이스 시스템 성능 향상을 위한 데이터베이스 관리 시스템 파라미터 튜닝 프로세스)

  • 최용락;윤병권;정기원
    • The Journal of Society for e-Business Studies
    • /
    • v.7 no.1
    • /
    • pp.107-127
    • /
    • 2002
  • Database system parameter tuning is one of database system tuning that achieve to improve performance of database system with application program tuning and data model tuning. By parameter tuning adjusts value of entry that is staled in data dictionary's parameter file that is included to database system, it is thing which make relevant database system can display performance of most suitable. And, it is that achievement is one o( possible tuning method immediately without occurrence of additional expense or involved hardware for database system performance elevation and ashes composition of software. But, it is actuality that administration about parameter practical use is not achieved, and is using Default Value of parameter that database management system offers just as it is systematically. So, this paper presents parameter tuning process that can :achieve Parameter tuning of database system that is operating present systematically, and parameter tuning process each activity important input urea and tuning achievement product. And explain about effect and result that happen by sort database system performance and parameters that it is affinity systematically, and grasp relationships between parameter, and change parameter of string database system. And not that parameter uses contents that specify by fixing when establish database administration system, is going to emphasize and explain that must utilize changing continuously during database system operation. It changes parameter entry value how in various kinds different operation environment and present if must apply, and will arrange effect that this parameter enoy value alteration gets in performance liking into account point that is actuality that is using parameter that define database administrators when install the database system just as it is continually without alteration.

  • PDF

The Parameter Estimation of DC-DC Converter by System Identification Method (시스템 식별 기법을 이용한 DC-DC 컨버터 파라메터 추정)

  • Jeon, Jin-Hong;Kim, Tae-Jin;Kim, Kwang-Su;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.503-506
    • /
    • 2003
  • In this paper, we present the results of parameter estimation for do-dc converter model by system identification. The parameter estimation for dc-dc converter aims at the diagnosis of its operating status. we applied the system identification method for parameter estimation. For verification of estimated parameter, we compare bode plot of estimated system transfer function and measurement results of HP4194 instrument.

  • PDF

Parameter Estimation by OE model of DC-DC Converter System for Operating Status Diagnosis

  • Jeon, Jin-Hong;Kim, Tae-Jin;Kim, Kwang-Su;Kim, Kwang-Hwa
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.206-210
    • /
    • 2004
  • This paper deals with a parameter estimation of the DC-DC converter system for its diagnosis. Especially, we present the results of parameter estimation for the DC-DC converter model by the system identification method. The parameter estimation for the DC-DC converter system aims at the diagnosis of its operating status. For the operating status diagnosis of the DC-DC converter system, we assume that the DC-DC converter system is an equivalent model of the Buck converter and estimate the main parameter for on-line diagnosis. In addition, for verification of an estimated parameter, we compare a bode plot of the estimated system transfer function and measurement results of the HP4194 instrument. It is a control system analyzer for system transfer function measurement. Our results confirm that the main parameter for diagnosis of the DC-DC converter system can be estimated by the system identification method and that the aging status of the system can be predicted by these results on operating status.

The Experimental Parameter Identification of Electro-Hydraulic Servo Control System (유압 서어보 제어 시스템의 설계 변수 결정의 실험적 고찰)

  • 김영대;강석종;이관섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.957-961
    • /
    • 1991
  • The parameters of electro-hydraulic servo system are closely dependent on the variation of system characteristics. Especially the parameter sensitivity is incleased in the servo system with heavy load and wide operating range. This paper shows the effect of parameter variation and the experimental parameter values of high power servo system.

  • PDF

EXISTENCE OF OPTIMAL SOLUTION AND OPTIMALITY CONDITION FOR PARAMETER IDENTIFICATION OF AN ECOLOGICAL SPECIES SYSTEM

  • LI CHUNFA;FENG ENMIN
    • Journal of applied mathematics & informatics
    • /
    • v.18 no.1_2
    • /
    • pp.273-286
    • /
    • 2005
  • Parameter identification problem of a three species (predator, mutualist-prey, and mutualist) ecological system with reaction-diffusion phenomenon is investigated in this paper. The mathematical model of the parameter identification problem is constructed and continuous dependence of the solution for the direct problem on the parameters identified is obtained. Finally, the existence of optimal solution and an optimality necessary condition for the parameter identification problem are given.

Robust control of nonlinear system by using pole sensitivity (극점감도를 고려한 비선형 시스팀의 강인한 제어)

  • 서병설;강진식;임동균
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.185-190
    • /
    • 1991
  • In this paper, we present a method of analising a system with nonlinear parameter by pole sensitivity defined by the rate of pole movement with respect of non-linear parameter variation. Pole sensitivity give us not only the rate of pole movement but also the directional information. We present a method of design of a state feedback for a system with nonlinear system parameter by considering the pole sensitivity and show that the suggested method guarantee the stability robustness for a system with nonlinear parameter, parameter perturbation and urimodelled dynamics.

  • PDF

Tracking control of variable stiffness hysteretic-systems using linear-parameter-varying gain-scheduled controller

  • Pasala, D.T.R.;Nagarajaiah, S.;Grigoriadis, K.M.
    • Smart Structures and Systems
    • /
    • v.9 no.4
    • /
    • pp.373-392
    • /
    • 2012
  • Tracking control of systems with variable stiffness hysteresis using a gain-scheduled (GS) controller is developed in this paper. Variable stiffness hysteretic system is represented as quasi linear parameter dependent system with known bounds on parameters. Assuming that the parameters can be measured or estimated in real-time, a GS controller that ensures the performance and the stability of the closed-loop system over the entire range of parameter variation is designed. The proposed method is implemented on a spring-mass system which consists of a semi-active independently variable stiffness (SAIVS) device that exhibits hysteresis and precisely controllable stiffness change in real-time. The SAIVS system with variable stiffness hysteresis is represented as quasi linear parameter varying (LPV) system with two parameters: linear time-varying stiffness (parameter with slow variation rate) and stiffness of the friction-hysteresis (parameter with high variation rate). The proposed LPV-GS controller can accommodate both slow and fast varying parameter, which was not possible with the controllers proposed in the prior studies. Effectiveness of the proposed controller is demonstrated by comparing the results with a fixed robust $\mathcal{H}_{\infty}$ controller that assumes the parameter variation as an uncertainty. Superior performance of the LPV-GS over the robust $\mathcal{H}_{\infty}$ controller is demonstrated for varying stiffness hysteresis of SAIVS device and for different ranges of tracking displacements. The LPV-GS controller is capable of adapting to any parameter changes whereas the $\mathcal{H}_{\infty}$ controller is effective only when the system parameters are in the vicinity of the nominal plant parameters for which the controller is designed. The robust $\mathcal{H}_{\infty}$ controller becomes unstable under large parameter variations but the LPV-GS will ensure stability and guarantee the desired closed-loop performance.

A Parameter Optimization Algorithm for Power System Stabilization (전력 계통 안정화를 위한 선재설계에 관한 연구)

  • 곽노홍;문영현
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.8
    • /
    • pp.792-804
    • /
    • 1990
  • This paper describes an efficient optimization algorithm by calculating sensitivity function for power system stabilization. In power system, the dynamic performance of exciter, governor etc. following a disturbance can be presented by a nonlinear differential equation. Since a nonlinear equation can be linearized for small disturbances, the state equation is expressed by a system matrix with system parameters. The objective function for power system operation will be related to the system parameter and the initial state at the optimal control condition for control or stabilization. The object function sensitivity to the system parameter can be considered to be effective in selecting the optimal parameter of the system.

  • PDF

Parameter Selection Method for Power System Stabilizer of a Power Plant based on Hybrid System Modeling (하이브리드시스템 모델링 기반 발전기 전력시스템 안정화장치 정수선정 기법)

  • Baek, Seung-Mook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.883-888
    • /
    • 2014
  • The paper describes the parameter tuning of power system stabilizer (PSS) for a power plant based on hybrid system modeling. The existing tuning method based on bode plot and root locus is well applied to keep power system stable. However, due to linearization of power system and an assumption that the parameter ratio of the lead-lag compensator in PSS is fixed, the results cannot guarantee the optimal performances to damp out low-frequency oscillation. Therefore, in this paper, hybrid system modeling, which has a DAIS (differential-algebraic-impusive-switched) structure, is applied to conduct nonlinear modeling for power system and find optimal parameter set of the PSS. The performances of the proposed method are carried out by time domain simulation with a single machine connected to infinite bus (SMIB) system.

STABILITY LIMIT PROPERTIES OF CONTROL SYSTEMS ON THE SPACE OF ADJUSTING PARAMETERS (조정파라미터 공간에서의 제어계 안정한계 특성)

  • 최순만
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.135-142
    • /
    • 2000
  • The adjusting parameter set which enable control systems to locate on stability limit can be derived from theoretical or trial methods for an existing real system. The data from the results are much available to keep a system in the Proper stability condition even to site engineers who are inexperienced in the control system. In this paper, a general one loop control system was adopted for a model system the process of which was assumed to consist of a time-delay element and a first order-lag element in series. After obtaining the corresponding parameter set for the model system by mathematical procedures, their loci on the parameter space was taken according to frequency change. The parameter set loci of stability limit showed unique pattern, and particularity , the curves on the Kg-Ti parameter space were able to be generalized in the form of, an unique exponential formula. These properties were also compared with the results taken from experimental procedures by Nyquist response method and Ziegler & Nichols method on the time domain, and both results were confirmed to be nearly same.

  • PDF