• Title/Summary/Keyword: System Operation

Search Result 20,270, Processing Time 0.078 seconds

An Analysis of Process-oriented Design in the Invited Entries of International Competition for the Master Plan of the Yongsan Park, Korea (용산공원 설계 국제공모 출품작에 나타난 프로세스적 설계 분석)

  • So, Jin;Sung, Jong-Sang;Pae, Jeong-Hann
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.2
    • /
    • pp.11-26
    • /
    • 2013
  • Designing large parks such as Yongsan Park requires the open-ended process-oriented design approach in complex layers rather than the conventional self-completed master plan method. This study aims to examine the characteristics of process-oriented design in the eight invited entries of "International Competition for the Master Plan of the Yongsan Park, Korea"(2012). For this purpose, it analyzed each entry according to three criteria: objects of process-oriented approach, time factor and its features of phasing plan, and presentation method of the process. This analysis can not only critically review the current level of the process-centered design methodology but also suggest strategic future directions for Yongsan Park. The objects of process-oriented design in the eight works were order of physical space development, restoration process of ecosystem, recovering process of publicity, and economic operation and management. Main considerations in the objects were connections to adjacent urban fabrics, links to regional green and water system, reuse of existing buildings and infrastructures in the site. The temporal criteria of the phasing plan had two aspects. One was planning a certain time and period, and the other was just establishing an order of phases. Most of the presentation method of process was the phasing plan, but some of the entries suggested a scenario plan. The eight works of "International Competition for the Master Plan of Yongsan Park" did not attempt process-oriented designs entirely and completely. Rather, they tried to introduce the phasing plan as part of a process-centered design. Also, they took an eclectic approach between master plan and process-oriented design instead of rejecting the conventional master plan approach.

The Factors Influencing Survival of Out-of-hospital Cardiac Arrest with Cardiac Etiology (병원 밖에서 발생한 심인성 심장정지환자의 생존 관련 요인 7년간 국가심장정지조사사업 자료 활용)

  • Jeong, Su-Yeon;Kim, Chul-Woung;Hong, Sung-Ok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.560-569
    • /
    • 2016
  • Purpose The purpose of this study was not only to explore the factors associated with the survival of OHCA(Out-of-hospital Cardiac Arrest), but to provide ideas for improving the operation of emergency medical system in Korea. Method 90,734 OHCAs(Out-of-hospital Cardiac Arrest) with a cardiac etiology, who had been transported by 119 EMS ambulances for seven years from 2006 to 2012 in Korea, were analyzed. The data had a multilevel structure in that patient's survival in the same region is interrelated, so two-level (patient-region) logistic regression analysis was applied to adjust this correlation. Results The adjusted OR in group who were given CPR(Cardiopulmonary Resuscitation) by a bystander were 1.40 for survival to discharge. In addition, the adjusted OR in the group with an implementation of AED (automated external defibrillator) before arriving in hospital was 2.98 for survival to discharge. we categorized some continuous variables (number of emergency physician, OHCAs volume fo hospital, area deprivation level) into five quintiles. The adjusted OR in the number of emergency physician compared with Q1(lowest) was 1.29(Q2), 2.89(Q3), 3.39(Q4), 4.07(Q5), respectively. the adjusted OR in OHCAs volume of each hospital compared with Q1(lowest) was 2.06(Q2), 3.06(Q3), 3.46(Q4), 4.36(Q5), respectively. Lastly, the adjusted OR in deprivation level compared with Q1(least deprived area) was 0.72(Q4), 0.64(Q5) so that the adjusted OR of survival to discharge tended to decrease in more deprived districts. Conclusion The survival to discharge was better significantly in group given CPR by a bystander and with the implementation of AED before arriving in hospital. The survival to discharge tended to be significantly better in hospitals with a larger number of emergency physicians and higher volume of OHCAs in less deprived districts.

Study on the Consequence Effect Analysis & Process Hazard Review at Gas Release from Hydrogen Fluoride Storage Tank (최근 불산 저장탱크에서의 가스 누출시 공정위험 및 결과영향 분석)

  • Ko, JaeSun
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.449-461
    • /
    • 2013
  • As the hydrofluoric acid leak in Gumi-si, Gyeongsangbuk-do or hydrochloric acid leak in Ulsan, Gyeongsangnam-do demonstrated, chemical related accidents are mostly caused by large amounts of volatile toxic substances leaking due to the damages of storage tank or pipe lines of transporter. Safety assessment is the most important concern because such toxic material accidents cause human and material damages to the environment and atmosphere of the surrounding area. Therefore, in this study, a hydrofluoric acid leaked from a storage tank was selected as the study example to simulate the leaked substance diffusing into the atmosphere and result analysis was performed through the numerical Analysis and diffusion simulation of ALOHA(Areal Location of Hazardous Atmospheres). the results of a qualitative evaluation of HAZOP (Hazard Operability)was looked at to find that the flange leak, operation delay due to leakage of the valve and the hose, and toxic gas leak were danger factors. Possibility of fire from temperature, pressure and corrosion, nitrogen supply overpressure and toxic leak from internal corrosion of tank or pipe joints were also found to be high. ALOHA resulting effects were a little different depending on the input data of Dense Gas Model, however, the wind direction and speed, rather than atmospheric stability, played bigger role. Higher wind speed affected the diffusion of contaminant. In term of the diffusion concentration, both liquid and gas leaks resulted in almost the same $LC_{50}$ and ALOHA AEGL-3(Acute Exposure Guidline Level) values. Each scenarios showed almost identical results in ALOHA model. Therefore, a buffer distance of toxic gas can be determined by comparing the numerical analysis and the diffusion concentration to the IDLH(Immediately Dangerous to Life and Health). Such study will help perform the risk assessment of toxic leak more efficiently and be utilized in establishing community emergency response system properly.

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy (재발한 Vulvar 종양의 근접치료 시 Modified Mupit Applicator의 적용)

  • Kim, Jong-Sik;Jung, Chun-Young;Oh, Dong-Gyoon;Song, Ki-Won;Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.13-19
    • /
    • 2006
  • Purpose: To evaluate whether modified MUPIT applicator can effectively eradicate recurrent tumor in uterine cervix cancer and reduce rectal complication after complete radiation treatment. Materials and Methods: Modified MUPIT applicator basically consists of an acrylic cylinder with flexible brain applicator, an acrylic template with a predrilled array of holes that serve as guides for interstitial needles and interstitial needles. CT scan was peformed to determine tumor volume and the position of interstitial needles. Modified MUPIT applicator was applied to patient in operation room and the accuracy for position of interstitial needles in tumor volume was confirmed by CTscan. Brachytherapy was delivered using modified MUPIT applicator and RALS(192-lr HDR) after calculated computer planning by orthogonal film. The daily dose was 600cGy and the total dose was delivered 3,000 cGy in tumor volume by BID. Rectal dose was measured by TLD at 5 points so that evaluated the risk of rectal complication. Results: The application of modified MUPIT applicator improved dramatically dose distributions in tumor volume and follow-up of 3 month for this patient was clinically partial response without normal tissue complication, Rectal dose was measured 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy at each points, especially the rectal dose including previous EBRT and ICR was 34.1 cGy, 57.1 cGy. Conclusion: Patients with locally recurrent tumor in uterine cervix cancel treated with modified MUPIT applicator can expect reasonable rates of local control. The advantages of the system are the fixed geometry provided by the template and cylinders. and improved dose distributions in irregular tumor volume without rectal complication.

  • PDF

Action Plan of Security Service against a Fire case in a Tall Building Event (경호행사시 초고층건물 화재 대응방안)

  • Son, Kyung-Hwan
    • Korean Security Journal
    • /
    • no.39
    • /
    • pp.37-61
    • /
    • 2014
  • Nowadays the world is threatened because of terrors that take aim at Soft-Targets available and easy to access to the people rather than more secured Hard-Targets. The inspection department of the Presidential Security Service develops and acts a perfect safety plan wherever the President stays so that it is possible to get immediate actions for various contingencies. Some events, in which the President take part, could be held in a lower or higher store in a tall building. Additional to the routine work at this case it is to emphasize on a plan of fire precaution to check the spot and respond to a real fire situation, so that the damage could be minimized. First, the agents of the President Security Service should possess basic knowledge concerning to the fire accidents and be trained on their manuals, even in a busy events plan. An organization, whatever it is, could be improved in that it tries to develop not only the personal abilities, but also education programs of the organization continually. And enhanced abilities of the members lead to the driving force for the advance. The knowledge of fire accident should be able to adapt to the real situation. Second, related to the event, it should be cooperated with the relevant departments, so that it is possible to conduct and control the system. It is urgently required to know that the security event could not be done perfectly with only one part or department. Third, from the time of recognizing of the event it is necessary for the fire department to get an action plan with fire fighting measures, evacuation measures based of the instructions given by the Security Service. Fourth, on the knowledge of the action plan of the fire department the Security Service should inspect the safety activities of the spot and establish the practical operation plan through the fire fighting and evacuation plan. Fifth, the Security Service should share final informations and plan of fire fighting in a high-rise building with the other relevant departments. If not, it could cause a great confusion that could lead to a great damage.

  • PDF

Comparison of Greenhouse Gas Emission from Liquid Swine Manure According to Aeration Levels in Summer (돈분뇨 액비의 폭기수준에 따른 여름철 온실가스 배출량 비교)

  • Choi, Dong-Yoon;Park, Kyu-Hyun;Cho, Sung-Back;Yang, Seong-Hak;Hwang, Ok-Hwa;Kwag, Jung-Hoon;Ahn, Hee-Kwon;Yoo, Yong-Hee
    • Journal of Animal Environmental Science
    • /
    • v.17 no.3
    • /
    • pp.163-170
    • /
    • 2011
  • This study was carried out to investigate greenhouse gas (GHG), $CH_4$ and $N_2O$, emission from liquid swine manure according to aeration levels in summer. To evaluate the influence of operation methods on GHG emissions, liquid swine manure were applied with different rates of aeration (store without aeration, $1m^3/ton/h$, $2.5m^3/ton/h$, and $5m^3/ton/h$). Following are the results of this study. The liquid swine manure applied no aeration, $1m^3/ton/h$, $2.5m^3/ton/h$, and $5m^3/ton/h$ aeration rates released 315.6, 13.9, 17.9 and $9.6{\mu}g/m^2/s$ of $CH_4$ and 0.173, 0.157, 0.131, and $0.241{\mu}g/m^2/s$ of $N_2O$, respectively. Liquid swine manure applied no aeration released the most amount of GHG ($6,681.4{\mu}g/m^2/s$ $CO_2$-Eq.) and followed by $5m^3/ton/h$ ($276.4{\mu}g/m^2/s$ $CO_2$-Eq.), $2.5m^3/ton/h$ ($416.0{\mu}g/m^2/s$ $CO_2$-Eq.), and $1m^3/ton/h$ ($340.8{\mu}g/m^2/s$ $CO_2$-Eq.). Our results reveal that the aerated system may reduce GHG emissions compared to no aeration. Consequently, aeration and mixing were effective at reducing GHG emissions during liquid swine manure storage.

Improving of the Fishing Gear and Development of the Automatic Operation System in the Anchovy Boat Seine-I -Underwater Geometry of the Model Net- (기선권현망어업의 어구 개량과 자동화 조업시스템 개발-I -시험어구의 수중형상-)

  • 장충식;김용해;안영수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.4
    • /
    • pp.299-308
    • /
    • 2000
  • A model experiment on the anchovy boat seine was carried out in the southern sea of korea to analyze the vertical opening and the underwater geometry. The model net A was made of half size in the length and width of the prototype net. The model net B was attached floats and chain to the model net-A. The vertical opening and the underwater geometry of the model net were determined by distance of Minilog position with the combinations of the distance between paired boats and the towing speed. The results obtained can be summarized as follows; 1. Vertical opening of the model net was gradually lowered according to the increase of the distance between paired beats and the towing speed. 2. Vertical opening of Wing net, In side wing net, Square, Fore bag net, Flapper and After bag net of the model net A according to the distance between paired boats were varied in the range of 10.8~9.0, 12.0~8.3, 12.6~9.0, 10.4~6.6, 4.6~5.2, 8.8~7.7m respectively, varied in the range of 36~30, 21~15, 31~22, 80~51, 80~96, 59~51% of the normal opening respectively 3. Vertical opening of Wing net, In side wing net, Square, Fore bag net, Flapper and After bag net of the model net B according to the distance between paired boats were varied in the range of 9.1~8.5, 9.8~6.5, 11.2~8.0, 11.0~8.1, 4.7~5.0, 7.0~7.5m respectively, varied in the range of 30~28, 18~12, 27~20, 85~62, 87~93, 47~50% of the normal opening respectively 4. Vertical opening of each a part of the model net according to the towing speed was as same as the former. 5. Model net was appeared apparent the pocket shape, because Wing net and Inside wing net was opened 30% of the normal opening. 6. The bosom and the bag net of the model net A were risen up to the upper lazer, this phenomenon was more apparent as the distance between paired boats and the towing speed increase, but the model net B was almost constant. 7. Working depth of the model net was gradually hallowed according to the increase of the distance between paired boats and the towing speed

  • PDF

Electrochemical Decontamination of Metallic Wastes Contaminated with Uranium Compounds (우라늄화합물로 오염된 금속폐기물의 전해제염)

  • 양영미;최왕규;오원진;유승곤
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • A study on the electrolytic dissolution of SUS-304 and Inconel-600 specimen was carried out in neutral salt electrolyte to evaluate the applicability of electrochemical decontamination process for recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant in Korea. Although the best electrolytic dissolution performance for the specimens was observed in a Na2s04 electrolyte, a NaNO$_3$ neutral salt electrolyte, in which about 30% for SUS-304 and the same for Inconel-600 in the weight loss was shown in comparison with that in a Na$_2$SO$_4$ solution, was selected as an electrolyte for the electrochemical decontamination of metallic wastes with the consideration on the surface of system components contacted with nitric acid and the compatibility with lagoon wastes generated during the facility operation. The effects of current density, electrolytic dissolution time, and concentration of NaNO$_3$ on the electrolytic dissolution of the specimens were investigated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as UO$_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion facility were performed in 1M NaNO$_3$ solution with the current density or In mA/$\textrm{cm}^2$. it was verified that the electrochemical decontamination of the metallic wastes contaminated uranium compounds was quite successful in a NaNO$_3$ neutral salt electrolyte by reducing $\alpha$ and $\beta$ radioactivities below the level of self disposal within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

Study on the Small Grain Bin for the Improvement of Grain Drying and Storage (곡물건조저장법 개선을 위한 농가용 Grain Bin에 관한 연구)

  • 김성래
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.1
    • /
    • pp.3263-3291
    • /
    • 1974
  • Experimental work of grain bin was carried out to develop the methods of natural air in-bin drying and storage. The method is considered to be more economical, labour saving, and an effective countermeasure to grain loss. To examine the possibility of farm use of the grain bin and to analyze the related factors concerned with in-bin grain drying and storage, ambient air conditions (especially the change of air temperature and relative humidity) and grain quality during drying and storage periods were investigated. A laboratory model bin was constructed to investigate the effect of different forced air conditions on the drying characteristics of rice. In addition, a grain bin with 2.2m diameter and 1.8m height, considered to be the optimum size for the average Korean farm, was constructed and tested to examine the drying and storing characteristics of rice. The weather data analyzed in this study was the nine-year (from 1964 to 1972) record of air temperature and relative humidity in the Suweon area, and the thirty-year (from 1931 to 1960) record of pentad normal relative humidity and air temperature in the Seoul area. From the results of the weather data analyses, the adequate air delivery hours (which was arbitrary defined as the condition to give less than 75% relative humidity) to dry the rice during October were about nine hours (from approximately 10 A.M. to 7 P.M, ) a day, in which the average air temperature was about 15.9$^{\circ}C$ and average relative humidity was 66%. The occurence of days having three hours of such conditions was 1, 2, and 1-day within the 1st, 2nd add last 10-day periods for the month of October, respectively. Therefore, it may be considered that the weather condition in October was satisfactory for the forced natural air drying. The results of the laboratory model bin test were analyzed to obtain the drying curve and drying rate for different drying stages and grain layers in the bin corresponding to various conditions of forced natural air. A drying experiment with a prototype grain bin showed that an approximate 5 percent grain moisture gradient through a 1.6 meter grain deposit was observed after 80 hours of intermittent drying, giving an over dried zone in the lower grain layers and an extremely high grain moisture zone in the upper layers. This indicates that an effective measure should be taken to reduce this high moisture gradient. In order to investigate the drying characteristics of bulk grain in a layerturning operation a grain bin test was performed. This showed a significant improvement of uniform drying. In this test, approximate 107 hours were required to dry a depth of 1.6 meter of grain from an initial moisture content of 22.2 percent to a moisture content of 16.7 percent using an air delivery rate of 2.8 cubic meter per a minute per every cubic meter of grain. This resulted in a 2 percent moisture gradient from the top to the bottom of the bin. During storage period, till the end of June the average temperature of grain was 2~3$^{\circ}C$ higher than ambient air temperature. But during July when the grain moisture content went up slightly (less than 1 percent), the average temperature of the grain also increased to 3~5$^{\circ}C$ higher than ambient air temperature. It is therefore recommended that for safe grain storage, grain should not be stored in sheet metal bins after mid May. From the above results, in-bin rice drying and storage can be used effectively on Korean farms. It is strongly recommended that the use of grain-bin system should be implemented for farm use to improve farm drying and storage of rice.

  • PDF

The Survey of Particle Size of Total Mixed Ration in Korea (국내 TMR의 입자도에 관한 조사 연구)

  • Ki, K.S.;Kim, H.S.;Jeong, H.Y.;Lee, H.J.;Ahn, B.S.;Kim, J.S.;Kwang, S.W.;Kim, Y.K.;Ha, J.K.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.813-818
    • /
    • 2003
  • This study was carried out to survey operation system of self-making TMR and particle size of self-making and commercial TMR, then to compare TMR particle size recommended by Penn State Particle Size Separator. Daily mixing time in self-making TMR averaged 48.6${\pm}$28.0min., 2 augar type of mixer was most by 55.5% and daily 2 times of mixing in summer and other season was 44.4 and 22.2%, respectively. Percentage of residual feed in upper sieve(19mm diameter), middle sieve(8 to 18mm diameter) and lower pen was 21.5~25.6%, 16.0~25.8%, 52.8~61.4%, respectively, at self-making TMR mixer. Percentage of particle sizes of more than 19mm in self-making and commercial TMR was 24.9${\pm}$1.4 and 26.2${\pm}$1.7%, that of 8-10mm 22.8${\pm}$1.0 and 12.8${\pm}$1.2 and that of less than 8mm 52.3${\pm}$1.7 and 61.0${\pm}$1.5, respectively, which in particle length of 8~13mm in self-making and commercial TMR was lower by 82.6 and 100% compared to that recommended by Penn State particle separator, respectively. Especially there was not particle length of more than 19mm in commercial TMR at all. It is necessary to check the number of cows ruminating in a farm in order to estimate the particle size of TMR; it is recommended to change the TMR mixing time or the TMR formulae if the proportion of ruminating cows in a farm is less than 40 %.