• Title/Summary/Keyword: System Loss Factor

Search Result 594, Processing Time 0.038 seconds

State Feedback Control of PWM Current Source Converter and Inverter System (PWM 전류형 컨버터 및 인버터 시스템의 상태궤환 제어)

  • Ko, Sung-Beom;Lee, Dong-Choon;Ro, Chae-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.501-503
    • /
    • 1996
  • In this paper, a novel control strategy for PWM current source converter and inverter is proposed, applying a multivariable state feedback control. The PWM converter controls line current to be sinusoidal and make input power factor unity. In addition, the modulation index control of dc link current is carried out, which produces lower loss of switching devices. Since the voltage control of inverter output filter capacitor is performed a decoupling of the d-q current of the induction motor is well retained. With the proposed algorithm, both high dynamic responses and satisfactory static performance can obtained.

  • PDF

Numerical Studies on Thermo-Hydro-Mechanical Couplings for Underground Heat Storage. (암반내 축열시스템의 열-수리-역학적 상호작용에 대한 수치해석적 연구)

  • 이희석;김명환;이희근
    • Tunnel and Underground Space
    • /
    • v.8 no.1
    • /
    • pp.17-25
    • /
    • 1998
  • This paper investigates coupled thermal, mechanical and hydraulic phenomena in deep rock mass especially for underground heat storage system. Firstly, concepts of underground heat storage were presented and coupling phenomena in this area were illustrated. In order to understand the basic mechanism of thermal, hydraulic and deformation behavior in rock cavern disturbed by thermal gradient about 10$0^{\circ}C$, various numerical experiments were conducted using several codes. The study involves the behavior of fractured rock mass including rock joint. In spite of the limitation of codes modelling fully coupled effects, these codes could be applied in analysis of underground heat storage. The heat loss in rock mass, which is a major factor in heat storage, is insignificant in all results.

  • PDF

Calculation of Equivalent Feeder Geometries for CANDU Transient Simulations

  • Cho, Seungyon;Muzumdar, Ajit
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.429-436
    • /
    • 1995
  • This paper describes a methodology for determination of representative CANDU feeder geometry and the pressure drops between inlet/outlet header and fuel channel in the primary loop. A code, MEDOC, was developed based on this methodology and helps perform a calculation of equivalent feeder geometry for a selected channel group on the basis of feeder geometry data (fluid volume, mass flow rate, loss factor) and given property data pressure, quality, density) at inlet/outlet header. The equivalent feeder geometry calculated based on this methodology will be useful fur the transient thermohydraulic analysis of the primary heat transport system for the CANDU heavy water-cooled pressure tube reactor.

  • PDF

Loss Calculation and Reduction Method for Wind Power System (풍력 발전 계통에서의 손실 계산 및 손실 저감 대책)

  • Cho, Sung-Don;Hong, Sa-Il;Jun, Hyun-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.372-373
    • /
    • 2011
  • 대규모 풍력발전 단지의 전력 계통에서 발생되는 전력손실의 종류를 분석하고 손실 저감 대책을 경제성 평가를 통해서 검토하였다. 검토결과 풍력발전 단지의 경우 부지면적이 넓어 배전선로에 의한 손실이 크고, 풍력발전설비의 설비 이용율(Capacity Factor)과 전력판매단가가 타 발전설비에 비해 상대적으로 높기 때문에 발전소내의 가공전선의 크기를 크게 선정하는 경우 투자비 대비 전력 손실 감소로 인한 발전량 증가로 얻는 경제적 이득이 더 크므로 경제적인 손실 저감 대책인 것으로 검토되었다.

  • PDF

A Study on Development of Power Supply for High Frequency Induction Heating (고주파 유도가열용 전원장치의 개발에 관한 연구)

  • Lee, Bong-Seob
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.3
    • /
    • pp.179-186
    • /
    • 2002
  • This paper proposed LC resonant current fed high frequency inverter for high frequency induction heating using leakage inductance of transformer and, its described operating principle. The analysis of circuit presented by using normalized parameter in considering leakage inductance of transformer and, discussed characteristic evaluation of inverter circuit in detail. The proposed inverter is operating ZVS to reduce turn-on and turn-off loss of switching devices so, raised an efficiency. And, the experimental apparatus was made on base characteristic evaluation of theoretical analysis to discuss possibility on high frequency source and confirmed a rightfulness theoretical analysis. A result of study, the proposed inverter is higher utilizing factor using on leakage inductance of transformer and show possibility, which is application on high frequency power system.

  • PDF

Intersymbol Interferences Due to Mismatched Roll-off Factors and Sampling-Time Jitter in a Gaussian Noise Channel

  • Park, Seung Keun;Mok, Jin Dam;Na, Sang Sin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2E
    • /
    • pp.47-54
    • /
    • 1997
  • This paper presents two results on intersymbol interferences in baseband digital communication over an additive white Gaussian noise channel-the interferences due to mismatched square-root raised-cosine filters, in which the filters have different roll-off factors, and / or due to sampling-time jitter. The result for the mismatched filters is that even the jitter-free sampling causes intersymbol interference and it is negligibly small for a wide range of signal-to-noise ratio up to 10dB, for the roll-off factor ranging from 0.2 to 0.5, the mismatch loss being within 0.1dB from the optimum at around 10-6 .For jitter interference an approximation formula for the bit error probability is derived in case of the matched filters, which shows how the roll-off factors and the amount of jitter affect the system performance. The formula is reasonably accurate.

  • PDF

A Numerical Study on the Heat Transfer Performance of Single-Tube Annular Baffle System (단관 환형배플 시스템의 전열성능에 대한 수치해석)

  • Hong, Jeong-Ah;Jun, Yong-Du;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.621-626
    • /
    • 2012
  • A new baffle configuration, an annular baffles, are considered in the present study as an alternative to reduce the excessive pressure drop associated with the conventional segmental ones in typical operating conditions. The heat transfer and pressure drops are numerically simulated for a single tube shell-and-tube model and compared against the conventional-baffle cases. Baffle blockage ratio and number of baffles are considered as the major variables for the present study specifying a fixed baffle spacing. It is found that the heat transfer increases 1.4~2.2 times without significant pressure loss compared to the bare tube cases and the goodness factor increases 1.35 times compared to the conventional-baffle model.

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

A Study on the Measurement of Dynamic Properties of the Rubber Mount in the Impeller Fan Motor of the Air-conditioner (에어컨 실내기 팬 모터용 방진고무의 동특성 측정에 관한 연구)

  • Choi, Hyun;Kim, Jun-Woo;Kang, Tae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.185-190
    • /
    • 2001
  • The structure borne noise of the air-conditioner, which degrades the noise quality, is hardly reduced by the general noise treatments. It can be effectively reduced by eliminating the structural vibration which the noise originates from. The rubber vibration isolator prevents the dynamic force induced by the fan driving motor from exciting the chassis structure, which finally reduces the structure borne noise. The dynamic properties of the vibration isolation system such as the natural frequency of the vibration isolation and loss factor of the rubber isolator, need to be experimentally evaluated. In this paper, these dynamic properties were obtained by the resonant method using the impact hammer for 3 types of the isolator specimens. It is known that the isolation natural frequency of the axial direction of the rubber isolator is two times higher than that of the radial direction, and is proportional to the hardness of the rubber specimen.

  • PDF

A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock (철도차량 견인전동기의 가속열화수명평가 기술현황)

  • Wang, Jong-Bae;Kim, Ki-Jun;Choi, Young-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF