• Title/Summary/Keyword: System Loss Factor

Search Result 594, Processing Time 0.031 seconds

A Critique of Designing Resource Adequacy Markets to Meet Loss of Load Probability Criterion

  • Yoon, Yong T.;Felder, Frank A.
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.1
    • /
    • pp.35-41
    • /
    • 2003
  • To ensure resource adequacy in restructured electricity markets, policymakers have adopted installed capacity (ICAP) markets in some regions of the United States. These markets ensure that adequate generation exists to satisfy regional Loss of Load Probability(LOLP) criterion. Since the incentives created through ICAP mechanisms directly impact new generation and transmission investment decisions we examine one important factor that links ICAP markets with LOLP calculations;, determining the amount of ICAP credit assigned to particular generation units. First, we review and critique the literature on electric power systems' market failure resulting from demand exceeding supply. We then summarize the method of computing (the LOLP) as a means of assessing reliability and relate this method to ICAP markets. We find that only the expected value of available generation is used In current ICAP markets while ignoring the second and higher order moments, which tends to mis-state the ICAP value of a specific resource. We then consider a proposal whose purpose is to avoid this ICAP assignment issue by switching from ICAP obligations to options. We find that such a proposal may fail to not provide the benefits claimed and suffers from several practical difficulties. Finally, we conclude with some policy recommendations and areas for future research.

Effect on Ice Slurry Flowing in the Elbow of Various Angle (다양한 각도의 곡관 내에서 아이스슬러리의 유동에 따른 영향)

  • 김규목;박기원;권일욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.142-149
    • /
    • 2004
  • Recently, the government introduced the thermal storage system for reducing the electric power load. Especially, the ice slurry type has gained lots of interest due to its good heat transfer and flowing characteristics. This study was peformed to understand the effects of transporting ice slurry through elbows of various angle. Propylene glycol water solution was used and about 2 mm ice particles were circulated. The experiments were carried out under various conditions, such as concentration and velocity of water solution ranging between 0∼20 wt%, 1.5∼2.5 m/s, respectively. And elbows with 4 different angles of 30$^{\circ}$, 45$^{\circ}$, 90$^{\circ}$, 180$^{\circ}$. The differential pressure and IPF (ice packing factor) between the pipe entry and exit were measured. The tendency of pressure loss and outlet IPF in elbow is that the pressure loss was reduced as concentration and flow velocity of water solution is increased, and low value appeared at 10 wt% and 2.5 m/s. The variation of outlet IPF was compared with the inlet IPF in the range of $\pm$20%.

Element loss analysis of concentrically braced frames considering structural performance criteria

  • Rezvani, Farshad Hashemi;Asgarian, Behrouz
    • Steel and Composite Structures
    • /
    • v.12 no.3
    • /
    • pp.231-248
    • /
    • 2012
  • This research aims to investigate the structural behavior of concentrically braced frames after element loss by performing nonlinear static and dynamic analyses such as Time History Analysis (THA), Pushdown Analysis (PDA), Vertical Incremental Dynamic Analyses (VIDA) and Performance-Based Analysis (PBA). Such analyses are to assess the potential and capacity of this structural system for occurrence of progressive collapse. Besides, by determining the Failure Overload Factors (FOFs) and associated failure modes, it is possible to relate the results of various types of analysis in order to save the analysis time and effort. Analysis results showed that while VIDA and PBA according to FEMA 356 are mostly similar in detecting failure mode and FOFs, the Pushdown Overload Factors (PDOFs) differ from others at most to the rate of 23%. Furthermore, by sensitivity analysis it was observed that among the investigated structures, the eight-story frame had the most FOF. Finally, in this research the trend of FOF and the FOF to critical member capacity ratio for the plane split-X braced frames were introduced as a function of the number of frame stories.

Stand-Alone PV System by Parallel Operation Control of Current-Source Inverter without Battery (전류원 인버터의 병렬운전에 의한 축전지 없는 태양광 시스템의 구성)

  • 박성준;김종달
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.291-297
    • /
    • 2003
  • This paper presents a current-source-inverter based on a buck-boost configuration and its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150 [W] prototype equipped with digital signal processor TMS320F241.

Behavior of the Flexural Vibration Damping of a Sandwich Beam System with a Partially Inserted Viscoelastic Layer (점탄성층이 부분적으로 삽입된 샌드위치보의 횡진동 감쇠특성)

  • Park, Jin-Taek;Yu, Hyeong-Won;Jang, Seok-Won;Choe, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.225-233
    • /
    • 2002
  • The flexural vibration characteristics of a sandwich beam system with a partially inserted viscoelastic layer have been quantitatively studied using a finite element analysis in combination with a sine-sweep test. Antisymmetric mode shapes of the flexural vibration were visualized by the holographic interferometry and agreed with those calculated by the finite element simulation. Effects of the beam thickness as well as the length and thickness of partial viscoelastic layers on the system loss factor(η$\_$s/) and resonant frequency($\omega$$\_$r/) were significantly large fur the symmetric and antisymmetric modes of the beam system.

Contingency Selection Using Eigen-Sensitivity Analysis for Voltage Stability. (고유치감도 해석에 의한 전압안정도의 상정사고 선택)

  • Song, S.G.;Nam, H.K.;Shim, K.S.;Moon, Y.H.;Choi, H.K.;NamKung, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.66-68
    • /
    • 2000
  • The Eigen analysis in large power system provides much useful information that is not got in nose curve. The branch participation factor is not quantitative information and is an indirect method calculating incremental change in branch reactive loss. But the Eigen sensitivity analysis to each mode is direct and provides of quantitative information but this method because of needing much time is used in large power system. In this paper the Hessenberg method is used to obtaining dominant eignvalues and corresponding eigenvectors of Jacobian matrix. Ranking the critical contingencies is done by computing the Eigen sensitivity of each dominant eignvalues for changes of each line. The proposed algorithm is tested on the New England 30-bus system and KEPCO system in the year of 2000, which comprises of 791-bus and 2500-branches.

  • PDF

A Study on the Design, Fabrication and Characteristics Test of 25KJ Superconducting Magnetic Energy Storage (25KJ 초전도 에너지 저장장치의 설계,제작 및 특성 시험)

  • 홍원표;원종수;이송엽;이승원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.10
    • /
    • pp.683-693
    • /
    • 1988
  • For the economical and reasonable operation of electric power system according to continual increase of electric power demand and decrease of load factor, the potential application of superconducting magnertic energy storage [SMES] with high efficiency and fast response in the electric utility is receiving attractive attension. In the light of this background, to confirm the basic principle of SMES, theoretical study, design technique and fabrication procedure for superconducting coil, current lead, cryostat, measuring and protection system of SMES are described in detail. Especially, a new design technique for superconducting coil and current lead is porposed and it was proved experimentally by the performance test of SMES which is developed for the first time in our country. At the peak operating current 200A, the maximum magnetic field amd stored energy of the coil are 3.52T and 2500J, espectively. The thermal and mechanical stability of 2500J SMES is also confirmed experimetally by its characteristics test, AC loss, protection system, charge and discharge test. The experimetal results show good characteristics of energy storage system.

  • PDF

An Evaluation of Large Scale Distribution system Unbalance (3상 조류계산에 의한 대규모 배전계통의 불평형상태 평가)

  • 송현선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.1
    • /
    • pp.86-93
    • /
    • 1999
  • It is necessary to calculate the system's factor for reasonable operation and security enhancerrent of large scale distribution system This paper presents an effective three phase load flow calculation for distribution system unbalance evaluation. It takes into account an untranspoed transmission line, the core loss as a functioo of voltage on the serondary side of the transformer, and a generator unbalance mxle1 which is also suitable for a salient pole machine. The load flow algorithm is used Newton-RaiDson method of load flow equations in bus phase voltage.oltage.

  • PDF

Interface between Photovoltaic System and Utility Line using Current-Source PWM Inverter (전류원형 PWM 인버터를 이용한 태양광 시스템과 계통 연계를 위한 연구)

  • Kang, Feel-Soon;Park, Sung-Jun;Park, Han-Woong;Kim, Cheul-U
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.57-61
    • /
    • 2002
  • This paper presents a current-source-inverter based on a buck-boost configuration and its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150 W prototype.

  • PDF

A Study on Grid-connected Photovoltaic Current-Source Inverter using Parallel Connection (병렬연결을 이용한 계통연계형 태양광 전류형 인버터에 관한 연구)

  • Lim, Joung-Min;Cheang, Eui-Heang;Moon, Chae-Joo;Chang, Young-Hak;Kim, Eui-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1222-1223
    • /
    • 2007
  • This paper suggests a 6-pulse-shift converter with PWM current-source inverter based on buck-boost configuration to improve the efficiency and to reduce the switching frequency of inverter for photovoltaic generation system, the device can be operated as interface system between solar module system and power system grid without energy storage cell. the circuit has six current-source buck-boost converter which operate chopper part has one full bridge inverter which make a decision the polarity of AC output. Therefore, the proposed PWM power inverter has advantages such as the reduction of witching loss and realization of unity power factor operation. the theoretical backgrounds are discussed and the input-output characteristics for the implemented prototype inverter using TMS320F2812 are verified experimentally in this paper.

  • PDF