• Title/Summary/Keyword: System Integration Test

Search Result 503, Processing Time 0.024 seconds

Evaluation of Field Applicability of Shotcrete for Fiber-net Integrated Tunnel Support System through Mock-up Test (목업 테스트를 통한 숏크리트용 섬유 그물망 일체형 터널 지보시스템의 현장 적용성 평가)

  • Kim, Jiyoung;Choi, Seongcheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.72-78
    • /
    • 2020
  • The present study developed shotcrete for fiber-net integrated tunnel support system, which consists of fiber-net support materials including netlike fiber and shotcrete and integration technology between support materials. In addition, in order to evaluate the field applicability of the developed tunnel support system and compare with the performance of steel fiber reinforced shotcrete, mock -up test was conducted on the mock -up structure. The test results show that in the case of shotcrete containing coarse aggregate(S20A5RP10-C), the excessive rebound rate occurred as the secondary shotcrete was dropped during construction due to the degradation in bond performance with fiber-net. Also, in the case of steel fiber reinforced shotcrete, the amount of cast shotcrete fell short of target value due to the fiber ball and the degradation of pumpability. On the other hand, the amount of cast mortar shotcrete(S20A5RP10-M) and the installation position of fiber-net were almost close to the target values, and the lower rebound rate occurred compared to the steel fiber reinforced shotcrete.

Design of Enhanced IEEE 1500 Wrapper Cell and Interface Logic For Transition Delay Fault Test (천이 지연 고장 테스트를 위한 개선된 IEEE 1500 래퍼 셀 및 인터페이스 회로 설계)

  • Kim, Ki-Tae;Yi, Hyun-Bean;Kim, Jin-Kyu;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.109-118
    • /
    • 2007
  • As the integration density and the operating speed of System on Chips (SoCs) become increasingly high, it is crucial to test delay defects on the SoCs. This paper introduces an enhanced IEEE 1500 wrapper cell architecture and IEEE 1149.1 TAP controller for the wrapper interface logic, and proposes a transition delay fault test method. The method proposed can detect slow-to-rise and slow-to-fall faults sequentially with low area overhead and short test time. and simultaneously test IEEE 1500 wrapped cores operating at different core clocks.

A Novel Efficiency Optimization Strategy of IPMSM for Pump Applications

  • Zhou, Guangxu;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.515-520
    • /
    • 2009
  • According to the operating characteristics of pump applications, they should exhibit high efficiency and energy saving capabilities throughout the whole operating process. A novel efficiency optimization control strategy is presented here to meet the high efficiency demand of a variable speed Permanent Magnet Synchronous Motor (PMSM). The core of this strategy is the excellent integration of mended maximum torque to the current control algorithm, based on the losses model during the dynamic and the grade search method with changed step by fuzzy logic during the steady. The performance experiments for the control system of a variable speed high efficiency PMSM have been completed. The test results verified that the system can reliably operate with a different control strategy during dynamic and steady operation, and the system exhibits better performance when using the efficiency-optimization control.

Compressible Parabolized Stability Equation in Curvilinear Coordinate System and integration

  • Gao, Bing;Park, S.O.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.7 no.2
    • /
    • pp.155-174
    • /
    • 2006
  • Parabolized stability equations for compressible flows in general curvilinear coordinate system are derived to deal with a broad range of transition prediction problems on complex geometry. A highly accurate finite difference PSE code has been developed using an implicit marching procedure. Compressible and incompressible flat plate flow stability under two-dimensional and three¬dimensional disturbances has been investigated to test the present code. Results of the present computation are found to be in good agreement with the multiple scale analysis and DNS data. Stability calculation results by the present PSE code for compressible boundary layer at Mach numbers ranging from 0.02 to 1.5 are also presented and are again seen to be as accurate as the spectral method.

Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 - (현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 -)

  • Kim, Seon-Chil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF

RESTful Architecture of Wireless Sensor Network for Building Management System

  • Dinh, Ngoc-Thanh;Kim, Young-Han
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.1
    • /
    • pp.46-63
    • /
    • 2012
  • The concept of an "intelligent building" received significant attention from academic, industry and standard development organizations when technically termed a building management system (BMS). Wireless sensor networks (WSNs) and their recent development enhanced monitoring and control applications for the building's areas. This paper surveys and analyzes advantages of the main current and emerging approaches that may be fit for BMS. Specifically, we discuss challenges including interoperability, integration, overhead, and bandwidth limitation of WSNs in BMS. Based on analyses, we highlight the advantages of an IP-based and RESTful architecture approach as the most suitable solution for BMS using WSNs (BMS-WSN). The paper also describes our future direction and design for BMS-WSN based on these advantages. The purpose is to enable interaction of users with BMS-WSN in the same way as with any website while ensuring energy efficiency. A test-bed implementation and evaluation of a BMS application is also introduced in this paper to demonstrate the feasibility and benefits of IP-based and RESTful architecture for BMS.

CCD Signal Processing for Optimal Non-Uniformity Correction

  • Kong, Jong-Pil;Lee, Song-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.6
    • /
    • pp.645-652
    • /
    • 2010
  • The performance of the payload Electro-Optical System (EOS) in satellite system is affected by various factors, such as optics design, camera electronics design, and the characteristics of the CCD (Charge Coupled Device) used, etc. Of these factors, the camera electronics design is somewhat unique in that its operational parameters can be adjusted even after the satellite launch. In this paper, the effect of video gain on the non-uniformity correction performance is addressed. And a new optimal non-uniformity correction scheme is proposed and analyzed using the data from real camera electronics unit based on a TDI (Time Delayed Integration) type of CCD. The test results show that the performance of the conventional non-uniformity correction scheme is affected significantly when the video gain is added. On the other hand, in our proposed scheme, the performance is not dependent on the video gain. The insensitivity of the non-uniformity performance on the video-gain is mainly due to the fact that the correction is performed after the dark signal is subtracted from system response.

KO AC/DC Converter System Installation Status and Commissioning Plan at ITER Site (이터 초전도자석 전원공급장치 현장 설치현황 및 시운전 계획)

  • Song, Inho;Oh, Jong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.397-401
    • /
    • 2022
  • The construction of the ITER tokamak machine is ongoing at a 77% process rate to achieve the first plasma in 2025. The 18 sets of power supply systems comprising 400 MVA thyristor AC/DC converters for the superconducting magnets supplied by Korea (KO) are being installed with other systems, such as PF converters (China), DC busbars (Russia), and cooling water systems (India), in two buildings (Europe). The system interfaces have been defined during the design stage, and the systems have been manufactured. However, during the on-site installation work, several installation and integration issues emerged due to the manufacturing tolerance and design mistakes. To continue the installation and testing, the engineers of each system resolved the interface issues, planned the commissioning, and integrated the test plan. This paper describes the on-site installation status and issues and the commissioning plan of KO AC/DC converters.

Test Driver Generation for Integration Test between Real-Time Operating System and PLC Application (실시간 운영체제와 PLC 어플리케이션의 통합 테스트를 위한 테스트 드라이버 생성 방안)

  • Jang, Jin-A;Sung, Ah-Young;Choi, Byoung-Ju
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10c
    • /
    • pp.448-452
    • /
    • 2006
  • PLC 프로세서 모듈의 시스템 태스크는 RTOS 커널 및 PLC 어플리케이션과 유기적으로 연관되어 있기 때문에 단독으로 테스트 할 수 없고, 어플리케이션을 테스트 드라이버로 활용해야 한다. 본 논문에서는 RTOS와 PLC 어플리케이션의 통합 테스트 단계에서, 시스템 태스크를 테스트 하기 위한 테스트 드라이버를 생성하는 방안을 기술하고, 이를 원자력 발전소의 PLC 프로세서 모듈에 적용한 실험 결과를 기술한다.

  • PDF

Pseudo-Dynamic Tests on Base-Isolated Liquid Storage Tanks (기초분리(基礎分離)된 액체저장(液體貯藏)탱크의 유사(類似) 동적실험(動的實驗))

  • Kim, Nam Sik;Lee, Dong Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.51-64
    • /
    • 1993
  • Base-isolated liquid storage tanks under seismic loading were tested by the Pseudo-dynamic test method. Substructuring technique in which a mixed integration method was adopted and the liquid tanks were simply modeled as a discrete system. This study gave experimental verification on the advantage of mounting the liquid tanks on base isolators in order to reduce the hydrodynamic forces on the tank wall.

  • PDF