Dynamic Response of Drill Floor to Fire Subsequent to Blowout

  • Kim, Teak-Keon;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.110-119
    • /
    • 2020
  • Explosions and fires on offshore drilling units and process plants, which cause loss of life and environmental damage, have been studied extensively. However, research on drilling units increased only after the 2010 Deepwater Horizon accident in the Gulf of Mexico. A major reason for explosions and fires on a drilling unit is blowout, which is caused by a failure to control the high temperatures and pressures upstream of the offshore underwater well. The area susceptible to explosion and fire due to blowout is the drill floor, which supports the main drilling system. Structural instability and collapse of the drill floor can threaten the structural integrity of the entire unit. This study simulates the behavior of fire subsequent to blowout and assesses the thermal load. A heat transfer structure analysis of the drill floor was carried out using the assessed thermal load, and the risk was noted. In order to maintain the structural integrity of the drill floor, passive fire protection of certain areas was recommended.

A Study on the Floating House for New Resilient Living (새로운 탄력적인 생활을 위한 플로팅 주택에 대한 연구)

  • Moon, Changho
    • Journal of the Korean housing association
    • /
    • v.26 no.5
    • /
    • pp.97-104
    • /
    • 2015
  • This paper aims to discuss the concept of resilience in floating housing, to investigate the resilient features of floating houses & to review the possibility of floating housing as a new form of resilient living, and to suggest some reference ideas for the planning and design of floating housing projects. Resilient features of the floating house can be summarized as the buoyant characteristics for natural disasters, the easy employment & potential use of renewable and nearly self-sufficient energy systems in locations subject to limited energy sources, the movability, mobility, long life, water recycle system, prefabrication and modular construction with the potential for reduced environmental impact. Additional benefits include the potential for a peaceful and comfortable atmosphere due to direct connections with nature, good relationship with neighbors, a solid social spirit of unity, and sense of security. Considering the resilient features of floating house at a time of serious climate change requires a new paradigm, and floating/amphibious/floatable housing has great possibility as a new form of resilient living.

Designing and Implementing Serious Game for Programming Education (프로그래밍 교육을 위한 기능성 게임의 설계와 구현)

  • Jung, ChanYong
    • Journal of Korea Game Society
    • /
    • v.16 no.6
    • /
    • pp.143-150
    • /
    • 2016
  • Programming is a difficult meat for novices. Educatees nowadays start to play games before they first attend formal education. Serious games offer tools that may have potential to support programming trainers to become more engaged on their learning through a learn while having fun approach. This paper aims to design and implement serious game for programming education. Our serious game substitutes game rules and objects for elements of programming language. We will begin by describing the game mechanics, followed by the general system architecture, finalizing with a small conclusion. We also discuss the implications of our work for the development of the serious game that support the identified features and teach programming concepts.

A Study of Zero Energy Building Verification with Measuring and Model-based Simulation in Exhibition Building

  • Ha, Ju-wan;Park, Kyung-soon;Kim, Hwan-yong;Song, Young-hak
    • Architectural research
    • /
    • v.20 no.3
    • /
    • pp.93-102
    • /
    • 2018
  • With the change in Earth's ecosystems due to climate change, a number of studies on zero energy buildings have been conducted globally, due to the depletion of energy and resources. However, most studies have concentrated on residential and office buildings and the performance predictions were made only in the design phase. This study verifies the zero-energy performance in the operational phase by acquiring and analyzing data after the completion of an exhibition building. This building was a retention building, in which a renewable energy system using a passive house building envelope, solar photovoltaic power generation panels, as well as fuel cells were adopted to minimize the maintenance cost for future energy-zero operations. In addition, the energy performance of the building was predicted through prior simulations, and this was compared with actual measured values to evaluate the energy performance of the actual operational records quantitatively. The energy independence rate during the measurement period of the target building was 123% and the carbon reduction due to the energy production on the site was 408.07 tons. The carbon reduction exceeded the carbon emission (331.5 tons), which verified the carbon zero and zero-energy performances.

A design of Encoder Hardware Chip For H.264 (H.264 Encoder Hardware Chip설계)

  • Kim, Jong-Chul;Suh, Ki-Bum
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.100-103
    • /
    • 2008
  • In this paper, we propose H.264 Encoder integrating Intra Prediction, Deblocking filter, Context-Based Adaptive Variable Length Coding, and Motion Estimation encoder module. This designed module can be operated in 440 cycle for one-macroblock. To verify the Encoder architecture, we developed the reference C from JM 9.4 and verified the our developed hardware using test vector generated by reference C. The designed circuit can be operated in 166MHz clock system, and has 1800k gate counts using Charterd 0.18um process including SRAM memory. Manufactured chip has the size of $6{\times}6mm$ and 208 pins package.

  • PDF

A design of High-Profile IP for H.264 (H.264 High-Profile Intra Prediction 설계)

  • Lee, Hye-Yoon;Lee, Young-Ju;Kim, Ho-Eui;Suh, Ki-Bum
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.112-115
    • /
    • 2008
  • In this paper, we propose H.264 High Profile Encoder Intra Prediction module. This designed module can be operated in 306 cycle for one-macroblock. To verify the Encoder architecture, we developed the reference C from JM 13.2 and verified the our developed hardware using test vector generated by reference C. We adopt plan removal and SAD calculation to reduce the Hardware cost and cycle. The designed circuit can be operated in 133MHz clock system, and has 250K gate counts using TSMC 0.18um process including SRAM memory.

  • PDF

The Influence of Unit Plan Shapes to the Energy Efficiency of Collective Housing Simulated by ECO2 Software (ECO2 프로그램을 이용한 공동주택의 단위세대 평면 형태에 따른 에너지 효율 평가)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.89-94
    • /
    • 2015
  • Purpose: Various policies to reduce the energy consumption have been carried out to save Earth environment against global warming and environmental pollution in many countries. Energy consumption of buildings in Korea has reached 24% of total energy consumption, and energy consumption of apartment has been continuously increasing. Therefore, Korea government has executed building energy efficiency rating certification system to control energy consumption of buildings. Method: This study was conducted to evaluate the energy performance of apartment unit plans according to the increasement of front width of unit plans, and tried to present the basic data to design more energy conscious unit plans for apartments. For the study, three shapes of unit plans -the 2Bay, 3Bay and 4bay unit- were selected for imput models. They were simulated using ECO2 software to assess building energy efficiency rating certification in Korea. Result: According to the results, in cases that balcony windows were not installed, the primary energy consumption of the 3Bay and 4Bay units were less than 2Bay unit, respectively, 0.1% and 2,5%. The primary energy consumption of the 3Bay and 4Bay units, in cases that balcony windows were installed, was less than 2Bay unit, respectively, 1.7% and 3.2%.

Design of Function Point Evaluation for WOA-based System (WOA 기반 시스템을 위한 기능점수평가 설계)

  • Kim, Kyu-Eok;Han, Yong-Man;Park, Hae-Yoon;Choi, Jong-Moo;Yoo, Hae-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06b
    • /
    • pp.202-204
    • /
    • 2012
  • 새로운 비즈니스 환경 변화에 가장 빠르게 대응하는 것이 중요한 IT 환경에서 빠른 서비스의 생성과 컴포넌트의 재활용성이 중요해지고 있다. 한편, 기존 Legacy 시스템의 한계를 극복한 WOA(Web Oriented Architecture)가 부각되고 있지만 Web 기반 시스템의 경우 Legacy 시스템 측정에 알맞게 구축된 비용산정에 어려움을 겪고 있으며, 잘못된 비용 산정의 결과로 인하여 다수의 프로젝트가 실패할 위험을 안고 있다. 따라서 본 논문은 현재 국내 소프트웨어 개발 규모 산정을 위한 국제 표준인 FP(Function Point)를 통한 규모 산정 방식을 제안한다. 본 논문은 기존 FP방식이 가질수 있는 문제점을 제시하고, 기존 산정방식의 문제점을 개선한 연계 기능을 포함한 FP 산출 방법의 제안을 통해 WOA 도메인의 특징을 반영한 FP의 산출이 가능하다. 이를 통하여 WOA 기반 시스템의 정확한 예산 측정이 가능하며, 프로젝트의 실패를 감소할 수 있다.

Study on the LAN/ISDN Interface Through Frame Relay (프레임릴레이를 통한 LAN/ISDN 인터페이스 연구)

  • 양충렬;김진태
    • Information and Communications Magazine
    • /
    • v.11 no.4
    • /
    • pp.62-70
    • /
    • 1994
  • This paper discusses the LAN interface technics physically applicable to the ISDN exchange system through frame relay without changing of the basic exchange architecture. To ensure the success of frame relaying, it's interworking with the existing X.25 services is very imported, and for this purpose both X.75 and 1.122-based interworking alternative must be considered. Definition required to frame relay, interconnection of remote bridge and ways to design the Frame Handler carrying a frame realying in the ISDN node was introduced here. Subsequently, alternatives using the X.25 and X.75 or 1.122 as well as interconnection mechanism LAN and ISDN for the LAN interface and LAN and/or LAN interface and ISDN through frame relay was individually introduced. Through frame relay applications in the major countries, the achievement of high speed frame relaying service to the LAN was introduced.

  • PDF

Optimal Harvest-Use-Store Design for Delay-Constrained Energy Harvesting Wireless Communications

  • Yuan, Fangchao;Jin, Shi;Wong, Kai-Kit;Zhang, Q.T.;Zhu, Hongbo
    • Journal of Communications and Networks
    • /
    • v.18 no.6
    • /
    • pp.902-912
    • /
    • 2016
  • Recent advances in energy harvesting (EH) technology have motivated the adoption of rechargeable mobile devices for communications. In this paper, we consider a point-to-point (P2P) wireless communication system in which an EH transmitter with a non-ideal rechargeable battery is required to send a given fixed number of bits to the receiver before they expire according to a preset delay constraint. Due to the possible energy loss in the storage process, the harvest-use-and-store (HUS) architecture is adopted. We characterize the properties of the optimal solutions, for additive white Gaussian channels (AWGNs) and then block-fading channels, that maximize the energy efficiency (i.e., battery residual) subject to a given rate requirement. Interestingly, it is shown that the optimal solution has a water-filling interpretation with double thresholds and that both thresholds are monotonic. Based on this, we investigate the optimal double-threshold based allocation policy and devise an algorithm to achieve the solution. Numerical results are provided to validate the theoretical analysis and to compare the optimal solutions with existing schemes.