• 제목/요약/키워드: System Analysis Code

검색결과 2,227건 처리시간 0.033초

열수력 기기해석용 CUPID 코드 개발 및 평가 전략 (THE DEVELOPMENT AND ASSESSMENT STRATEGY OF A THERMAL HYDRAULICS COMPONENT ANALYSIS CODE)

  • 박익규;조형규;이재룡;김정우;윤한영;이희동;정재준
    • 한국전산유체공학회지
    • /
    • 제16권2호
    • /
    • pp.30-48
    • /
    • 2011
  • A three-dimensional thermal-hydraulic code, CUPID, has been developed for the analysis of transient two-phase flows at component scale. The CUPID code adopts a two-fluid three-field model for two-phase flows. A semi-implicit two-step numerical method was developed to obtain numerical solutions on unstructured grids. This paper presents an overview of the CUPID code development and assessment strategy. The governing equations, physical models, numerical methods and their improvements, and the systematic verification and validation processes are discussed. The code couplings with a system code, MARS, and, a three-dimensional reactor kinetics code, MASTER, are also presented.

MIDLOOP Code Analysis of a ROSA-IV/LSTF Experiment for the Loss of Residual Heat Removal System Event During Mid- loop Operation

  • Han, Kee-Soo;Lee, Cheol-Sin;Park, Chul-Jin;Kim, Hee-Cheol
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.683-690
    • /
    • 1996
  • The MIDLOOP code has been developed for the evaluation of RES pressurization transients initiated from a loss-of-Residual Heat Removal System (RHRS) during mid-loop operation after reactor shutdown. It provides a fast running and realistic tool for studying parametrically the response of important plant parameters such as pressure, temperature, and level to various plant combinations of the primary side vent, makeup, and leakage procedures and the steam generator (SG) conditions. The code consists of ten nodes representing the primary and secondary sides of a nuclear power plant and can analyze the effect of air on the primary system pressurization and primary to secondary heat transfer. The analysis results of the MIDLOOP code are in good agreement with the ROSA-IV/LSTF experiment without opening in the RCS.

  • PDF

Verification of HELIOS-MASTER System Through Benchmark of Critical Experiments

  • Kim, Ha-Yong;Kim, Kyo-Youn;Oh, Cho-Byung;Lee, Chung-Chan;Zee, Sung-Quun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.22-22
    • /
    • 1999
  • The HELlOS-MASTER code system is verified through the benchmark of the critical experiments that were performed by RRC "Kurchatov Institute" with water-moderated hexagonally pitched lattices of highly enriched Uranium fuel rods (8Ow/o). We also used the same input by using the MCNP code that was described in the evaluation report, and compared our results with those of the evaluation report. HELlOS, developed by Scandpower A/S, is a two-dimensional transport program for the generation of group cross-sections, and MASTER, developed by KAERI, is a three-dimensional nuclear design and analysis code based on the two-group diffusion theory. It solves neutronics model with the AFEN (Analytic Function Expansion Nodal) method for hexagonal geometry. The results show that the HELIOSMASTER code system is fast and accurate enough to be used as nuclear core analysis tool for hexagonal geometry.ometry.

  • PDF

Establishment of DeCART/MIG stochastic sampling code system and Application to UAM and BEAVRS benchmarks

  • Ho Jin Park;Jin Young Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권4호
    • /
    • pp.1563-1570
    • /
    • 2023
  • In this study, a DeCART/MIG uncertainty quantification (UQ) analysis code system with a multicorrelated cross section stochastic sampling (S.S.) module was established and verified through the UAM (Uncertainty Analysis in Modeling) and the BEAVRS (Benchmark for Evaluation And Validation of Reactor Simulations) benchmark calculations. For the S.S. calculations, a sample of 500 DeCART multigroup cross section sets for two major actinides, i.e., 235U and 238U, were generated by the MIG code and covariance data from the ENDF/B-VII.1 evaluated nuclear data library. In the three pin problems (i.e. TMI-1, PB2, and Koz-6) from the UAM benchmark, the uncertainties in kinf by the DeCART/MIG S.S. calculations agreed very well with the sensitivity and uncertainty (S/U) perturbation results by DeCART/MUSAD and the S/U direct subtraction (S/U-DS) results by the DeCART/MIG. From these results, it was concluded that the multi-group cross section sampling module of the MIG code works correctly and accurately. In the BEAVRS whole benchmark problems, the uncertainties in the control rod bank worth, isothermal temperature coefficient, power distribution, and critical boron concentration due to cross section uncertainties were calculated by the DeCART/MIG code system. Overall, the uncertainties in these design parameters were less than the general design review criteria of a typical pressurized water reactor start-up case. This newly-developed DeCART/MIG UQ analysis code system by the S.S. method can be widely utilized as uncertainty analysis and margin estimation tools for developing and designing new advanced nuclear reactors.

Development of a one-dimensional system code for the analysis of downward air-water two-phase flow in large vertical pipes

  • Donkoan Hwang;Soon Ho Kang;Nakjun Choi;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.19-33
    • /
    • 2024
  • In nuclear thermal-hydraulic system codes, most correlations used for vertical pipes, under downward two-phase flow, have been developed considering small pipes or pool systems. This suggests that there could be uncertainties in applying the correlations to accident scenarios involving large vertical pipes owing to the difference in the characteristics of two-phase flows, or flow conditions, between large and small pipes. In this study, we modified the Multi-dimensional Analysis of Reactor Safety KINS Standard (MARS-KS) code using correlations, such as the drift-flux model and two-phase multiplier, developed in a plant-scale air-inflow experiment conducted for a pipe of diameter 600 mm under downward two-phase flow. The results were then analyzed and compared with those based on previous correlations developed for small pipes and pool conditions. The modified code indicated a good estimation performance in two plant-scale experiments with large pipes. For the siphon-breaking experiment, the maximum errors in water flow for modified and original codes were 2.2% and 30.3%, respectively. For the air-inflow accident experiment, the original code could not predict the trend of frictional pressure gradient in two-phase flow as / increased, while the modified MARS-KS code showed a good estimation performance of the gradient with maximum error of 3.5%.

Analysis of Locked Rotor Event Using TASS Code

  • Lee, Byung-Il;Kim, Jong-Jin;Baek, Seung-Su;Um, Kil-Sub;Kim, Hee-Cheol
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.598-603
    • /
    • 1996
  • When locked rotor event. occurs, instantaneously affected loop and core flow were quickly reduced, which resulted in an increase in coolant temperature and system pressure. Analysis method of this event was that constant core inlet temperature and system pressure as well as change in core flow calculated from COAST code were statically used as an input variable to HERMITE code, because of no tools to simulate NSSS behavior and 1-D core neutronics transient coincidently. With employing TASS code revised with 1-D neutronics model, this event was analyzed in point of DNBR. By doing so, analysis procedure could be simplified and unreasonable conservatism might be removed in DNBR calculation by consideration of pressure increase.

  • PDF

Application of Hyperbolic Two-fluids Equations to Reactor Safety Code

  • Hogon Lim;Lee, Unchul;Kim, Kyungdoo;Lee, Won-Jae
    • Nuclear Engineering and Technology
    • /
    • 제35권1호
    • /
    • pp.45-54
    • /
    • 2003
  • A hyperbolic two-phase, two-fluid equation system developed in the previous work has been implemented in an existing nuclear safety analysis code, MARS. Although the implicit treatment of interfacial pressure force term introduced in momentum equation of the hyperbolic equation system is required to enhance the numerical stability, it is very difficult to implement in the code because it is not possible to maintain the existing numerical solution structure. As an alternative, two-step approach with stabilizer momentum equations has been selected. The results of a linear stability analysis by Von-Neumann method show the equivalent stability improvement with fully-implicit solution method. To illustrate the applicability, the new solution scheme has been implemented into the best-estimate thermal-hydraulic analysis code, MARS. This paper also includes the comparisons of the simulation results for the perturbation propagation and water faucet problems using both two-step method and the original solution scheme.

다양한 알고리즘 개발 툴 기반의 소스 코드를 적용한 생체신호 분석 시스템 개발 (Development of bio-signal analysis system applying source code based on various algorithm development tools)

  • 주문일;김원일;김희철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2018년도 추계학술대회
    • /
    • pp.238-240
    • /
    • 2018
  • 최근에는 다양한 생체신호 분석 툴을 활용하여 건강관리서비스가 개발 및 연구되고 있다. 대부분의 생체신호 분석 연구는 Matlab 및 R Programming을 활용한다. 그러나, Matlab과 R Programming으로 개발한 알고리즘을 시스템에 적용하기 위해서는 소스 코드의 변환 작업이 필요하다. 본 논문은 소스 코드의 변환 작업을 생략할 수 있는 스마트 인터페이스를 제공하고자 한다.

  • PDF

Numerical Analysis on Letdown System Performance Test for YGN 3

  • Seo, Ho-Taek;Sohn, Suk-Whun;Seo, Jong-Tae;Boo, Jung-Sook
    • Nuclear Engineering and Technology
    • /
    • 제29권2호
    • /
    • pp.158-166
    • /
    • 1997
  • Integrated performance test of Chemical and Volume Control System was successfully performed in 1994. However, an extensive effort to correct hardware and software problems in the letdown line was required mainly due to the lack of adequate simulation code to predict the test accurately. Although the LTC computer code was used during the YGN 3'||'&'||'4 NSSS design process, the code can not satisfactorily predict the test due to it insufficient letdown line modeling. This study developed a numerical model to simulate the letdown test by modifying the current LTC code, and then verified the model by comparing with the test data. The comparison shows that the modified LTC computer code can predict the transient behavior of letdown system lese very well. Especially, the model was verified to be able to predict the "Stiction (composition of stick and friction)" phenomena which caused instantaneous fluctuations in the letdown backpressure and flowrate. Therefore, it is concluded that the modified LTC computer code with the ability of calculating the "Stiction" phenomena will be very useful for future plant design and test predictions.predictions.

  • PDF

The Video on Demand System Failure Evaluation of Software Development Step

  • Jang, Jin-Wook
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권4호
    • /
    • pp.107-112
    • /
    • 2019
  • Failure testing is a test that verifies that the system is operating in accordance with failure response requirements. A typical failure test approaches the operating system by identifying and testing system problems caused by unexpected errors during the operational phase. In this paper, we study how to evaluate these Failure at the software development stage. Evaluate the probability of failure due to code changes through the complexity and duplication of the code, and evaluate the probability of failure due to exceptional situations with bugs and test coverage extracted from static analysis. This paper studies the possibility of failure based on the code quality of software development stage.