• Title/Summary/Keyword: System A/C

Search Result 21,579, Processing Time 0.066 seconds

Exergy Analysis and Optimization of Chiller System in Hydrogen Fueling Station Using R290 Refrigerant (R290 냉매를 이용한 수소 충전소 냉각시스템 엑서지 분석 및 공정 최적화)

  • HYEON, SOOBIN;CHOI, JUNGHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.5
    • /
    • pp.356-364
    • /
    • 2021
  • During the hydrogen fueling process, hydrogen temperature inside the compressed tank were limited below 85℃ due to the allowable pressure of tank material. The chiller system to cool compressed hydrogen used R407C, greenhouse gas with a high global warming potential (GWP), as a refrigerant. To reduce greehouse gas emission, it should be replaced by refrigerant with a low GWP. This study proposes a chiller system for fueling hydrogen with R290, consisted in propane, by applying the C3 pre-cooled system use d in the LNG liquefaction process. The proposed system consisted of hydrogen compression and cooling sections and optimized the operating pressure through exergy analysis. It was also compared to the exergy efficiency with the existing system at the optimal operating pressure. The result showed that the optimal operating pressure is 700 kPa in 2-stage, 840 kPa/490 kPa in 3-stage, and the exergy efficiency increased by 17%.

An Experimental Study on Performance Characteristics of Refrigeration System Using R134a Refrigerating System (R134a를 이용한 냉동장치의 성능특성에 관한 실험적 연구)

  • Kim, Jin-Hyun;Kim, Jong-Kil;Kim, Sung-Bae;Ha, Ok-Nam
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2188-2193
    • /
    • 2007
  • Since the use of CFCs and HCFCs refrigerants are to be restricted due to the depletion of ozone layer, this experiment applies the R134a gas to study the performance characteristic from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1.5 MPa to 1.6 MPa by 0.05 MPa and for superheat temperature from 0$^{\circ}C$ to 5$^{\circ}C$ by 1$^{\circ}C$ at each condensing pressure. As a result of experiment, when the superheat temperature is 1$^{\circ}C$ at each condensing pressure, the refrigeration system has the highest performance.

  • PDF

Measurement and Prediction of Autoignition Temperature of n-Butanol + n-Decane System (n-Butanol과 n-Decane계의 최소자연발화온도 측정 및 예측)

  • Ha, Dong-Myeong;Hong, Soo-Kang
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.184-189
    • /
    • 2011
  • This study measured the AITs of n-butanol + n-decane system from ignition delay time (time lag) by using ASTM E659 apparatus. The AITs of n-butanol and n-decane which constituted binary system were $340^{\circ}C$ and $212^{\circ}C$, respectively. The experimental AITs of n-butanol + n-decane system were a good agreement with the calculated AITs by the proposed equations with a few A.A.D. (average absolute deviation).

Surveillance System For Extra High Voltage Cable (초고압 CABLE 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Jeon, S.I.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.789-793
    • /
    • 1992
  • For improving the power supply reliability and minimizing maintenance work of E.H.V. underground transmission line, new surveillance systems are strongly desired for use in the field of electric power transmission. For underground installation, high system reliability is required because E.H.V. cables, if an accident happen, can have a serious impact on social activities and human life. In answer to this requirement, applications of optical fiber transmission system have been widely developed in a variety of field. The main function of this system are cable fault location, oil leak detection, and surveillance of the cable circuit and tunnel condition.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

A Study for Cyber Situation Awareness System Development with Threat Hunting (위협 헌팅을 적용한 사이버 상황인식 시스템 개발에 관한 연구)

  • Lee, Jaeyeon;Choi, Jeongin;Park, Sanghyun;Kim, Byeongjin;Hyun, Dae-Won;Kim, Gwanyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.807-816
    • /
    • 2018
  • Threat hunting is defined as a process of proactively and iteratively searching through networks to detect and isolate advanced threats that evade existing security solutions. The main concept of threat hunting is to find out weak points and remedy them before actual cyber threat has occurred. And HMM(Hunting Maturity Matrix) is suggested to evolve hunting processes with five levels, therefore, CSOC(Cyber Security Operations Center) can refer HMM how to make them safer from complicated and organized cyber attacks. We are developing a system for cyber situation awareness system with pro-active threat hunting process called unMazeTM. With this unMaze, it can be upgraded CSOC's HMM level from initial level to basic level. CSOC with unMaze do threat hunting process not only detecting existing cyber equipment post-actively, but also proactively detecting cyber threat by fusing and analyzing cyber asset data and threat intelligence.

Preparation and Characterization of a Propofol-loaded Polymeric Micellar System: Nanoparticular Stability

  • Cho, Jae-Pyoung;Cho, Jin-Cheol;Oh, Eui-Chaul
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.393-398
    • /
    • 2008
  • A propofol delivery system was prepared using two biocompatible polymeric surfactants, poloxamer 407 and PEG 400. The nanoparticular stability of the micellar system was evaluated in terms of temperature change, storage time and composition. The particle size of the system was slightly increased with elevating temperature from $4^{\circ}C$ to $25^{\circ}C$, but its distribution was unimodal. At $40^{\circ}C$, the system presented a bimodal particle size distribution and the increase in the fraction of particles larger than 15 nm. This result might be due to the expansion of the nanoparticles through micellar swelling at the high temperature. It was found that propofol was gradually come out of the system, stored for a month at three different temperatures (4, 25 and $40^{\circ}C$). The drug loss was apparently dependent on temperature and the system composition. Increasing temperature induced the acceleration of the drug loss of $7{\sim}10%$ at $4^{\circ}C$ and $14{\sim}16 %$ at $40^{\circ}C$. This may be owing to the high diffusivity resulting from the swelling of the hydrophilic surface of the nanoparticle at high temperature. However, the addition of PEG 400 to the system led to the reduction of the drug loss. This result is associated with the previous investigation that PEG coverage decreased diffusion coefficient because of the formation of the denser structure on the surface of nanoparticulate. Nevertheless, the limited amount of PEG, less than 2% (w/v), should be used to prevent the precipitation and discoloration of the system.

Assessment of System Reliability and Capacity-Rating of Concrete Box-Girder High-Girder Highway Bridges (R.C 박스거더교의 체계신뢰성해석 및 안전도평가)

  • 조효남;이승재;임종권
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.195-200
    • /
    • 1993
  • This paper develops practical and realistic reliability models and methods for the evalusion of system reliability and system reliability-based rating of R.C box-girder bridge superstructures. The precise prediction of reserved carrying capacity of bridge as a system is extremely difficult expecially when the bridges are highly redundant and significantly deteriorated or damaged. This paper proposes a new approach for the evaluation of reserved system carrying capacity of bridges in terms of equivalent system-strength, which may be defined as a bridge system-strength corresponding to the system reliability of the bridge. This can be derived from an inverse process based on the concept of FOSM form of system reliability index. The strength limit state models for R.C box-girder bridges suggested in the paper are based on the basic bending and shear strength. and the system reliability problem of box-girder superstructure is formulated as parallel-series models obtained from the FMA(Failure Mode Approach) based on major failure mechanism or critical failure states of each girder. AFOSM and IST(Importance Sampling Technique) simulation algorithm is used for the reliability analysis of the proposed models.

  • PDF

Study on Analysis of Suitable Site for Development of Floating Photovoltaic System (수상태양광 발전시스템 개발을 위한 적지조사에 관한 연구)

  • Lee, Sung-Hun;Lee, Nam-Hyung;Choi, Hyeong-Cheol;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.30-38
    • /
    • 2012
  • Recently, interests in renewable energy have gradually increased. Photovoltaic system of various renewable energy is the most interest in power sources. Nowadays, the market of photovoltaic system is expected to be expanded due to the introduction of RPS(Renewable Portfolio Standard). Floating photovoltaic system is a new power system using the water surface above the dam and reservoir water. Floating photovoltaic system is different from the traditional approach to the development of solar power system causing problems such as environmental degradation. This paper investigates the analysis methods of suitable site for the development of floating photovoltaic system. The A,B,C as the optimal candidates were selected in hap cheon dam. The C is the best suitable site in A,B,C considering the expected power generation. Applied methods have effectively done to develop floated photovoltaic system.

Microstructure and Mechanical Properties of Cr-Mo-Si-C-N Coatings Deposited by a Hybrid Coating System (하이브리드 코팅시스템에 의해 제조된 Cr-Mo-Si-C-N 박막의 미세구조 및 기계적 특성연구)

  • Yun, Ji-Hwan;Ahn, Sung-Kyu;Kim, Kwang-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.6
    • /
    • pp.279-282
    • /
    • 2007
  • Cr-Mo-Si-C-N coatings were deposited on steel and Si wafer by a hybrid system of AIP and sputtering techniques using Cr, Mo and Si target in $Ar/N_2/CH_4$ gaseous mixture. Instrumental analyses of XRD and XPS revealed that the Cr-Mo-Si-C-N coatings must be a composite consisting of fine(Cr, Mo and Si)(C and N) crystallites and amorphous $Si_3N_4$ and SiC. The hardness value of Cr-Mo-Si-C-N coatings significantly increased from 41 GPa of Cr-Mo-C-N coatings to about 53 GPa with Si content of 9.3 at.% due to the refinement of (Cr, Mo and Si)(C and N) crystallites and the composite microstructure characteristics. A systematic investigation of the microstructures and mechanical properties of Cr-Mo-Si-C-N coatings prepared with various Si contents is reported in this paper.