• Title/Summary/Keyword: System $B^{TM}$

Search Result 101, Processing Time 0.035 seconds

Evaluation of Damaged Stand Volume in Burned Area of Mt. Weol-A using Remotely Sensed Data (위성자료를 이용한 산화지의 입목 손실량 평가)

  • Ma, Ho-Seop;Chung, Young-Gwan;Jung, Su-Young;Choi, Dong-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.2 no.2
    • /
    • pp.79-86
    • /
    • 1999
  • This study was carried out to estimate the area of damaged forest and the volume of stand tree in burned area, Mt. Weol-A in eastern Chinju, Korea using digital maps derived from supervised classification of Landsat thematic mapper(TM) imagery as reference data. Criterion laser estimator and WinDENDRO$^{tm}$(v. 6.3b) system as a computer-aided tree ring measuring system were used to measure a volume and age of sampled tree. The sample site had been chosen in unburned areas having the same terrain condition and forest type of burned areas. The tree age, diameter at breast height, tree height and volume of the sample tree selected from sample site in unburned area were 27years, 20.9cm, 9.7m and $0.1396m^3$ respectively. Total stand volume of sample site was estimated $2.9316m^3$/0.04ha, Damaged stand volume evaluated to about $16,007m^3$ in the burned area of 218.4ha.

  • PDF

Comparative Analysis of Treatment Planning System and Dose Distribution of Gamma knife PerfexionTM using EBT-3 Film (EBT-3 필름을 사용한 감마나이프 퍼펙션TM의 치료 계획 시스템 및 선량 분포 비교 분석)

  • Jin, Seongjin;Kim, eongjin;Seo, Weonseop;Hur, Beongik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.509-515
    • /
    • 2017
  • The purpose of this study is to measure the 3 dimensional dose distribution of Gamma knife $Perfection^{TM}$, make a comparative analysis of the result and establish the measurement method for the procedures using EBT3 film. The dose distributions of the Gamma knife $Perfection^{TM}$ installed in two hospitals were evaluated in accuracy and precision. For accuracy, the difference between the mechanical center axis and the dose center axis was assessed on a 4 mm collimator. The allowed difference in accuracy is within 0.3 mm and it was measured as 0.098 mm, 0.195 mm for A hospital and 0.229 mm, and 0.223 mm for B hospital. For precision the difference between the FWHM(Full Width at Half Maximum) of Gamma Plan and measurement in the 4, 8, and 16 mm collimators was calculated. The allowed difference in precision is less than ${\pm}1mm$. The value of the hospital A was -0.283 ~ 0.583 mm, and the hospital B was -0.857 ~ 0.810 mm. When analyzing the dose distributions using the image-j program, it is necessary to establish a clearer reference point of the measurement point, and it is considered that the comparison of the dose distribution should be performed in actual treatment irradiation dose with a high dose usable film.

MPEG-2 Video Watermarking in Quantized DCT Domain (양자화된 DCT 영역에서의 MPEG-2 비디오 워터마킹)

  • Im, Yong-Soon;Kang, Eun-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.81-86
    • /
    • 2011
  • Watermarking is one of the methods that insist on a copyright as it append digital signals in digital informations.(image, video, ets) In this paper, we proposed a digital watermarking algorithm which improved Gradient of DCT Coefficient. This method targets MPEG-2 TM5 system and watermarking process is to be performed during Quantization DCT. Watermark was inserted on Y components of each frames. The PSNR difference between the compressed images with and without watermarking was only 0..23dB. In each case that the resulting image was reusable the normalized correlation between the extracted watermark and the original one was above 0.99.

COMPARISON OF THE INFLUENCE OF CANAL CURVATURE ON THE SEALING ABILITY OF LATERAL CONDENSATION AND SYSTEM BTM (측방가압법과 System BTM를 이용한 근관충전시 근관만곡도에 따른 폐쇄효과의 비교)

  • Lim, Dong-Yeul;Lee, Hee-Joo;Hur, Buck
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.482-489
    • /
    • 1999
  • The purpose of this study was to compare sealing ability between lateral condensation and continuous wave of condensation in depend of root canal curvature. In this study, we divided fifty-six human molar teeth into two group in depend of Schneider method, and then subdivided them into four experimental group (each group is composed of twelve teeth) by canal curvature and obturation method, and eight teeth were served as positive and negative controls. Specimens were prepared by Quantac 2000 series file and obturated by lateral condensation or System B. Specimens were immersed in india ink for 7 days, decalcified by 10% nitric acid, dehydrated by 75, 95 and 100% alcohol in order, cleared by methyl salicylate and then measured of dye penetration with stereomicroscope(${\times}6.5$ magnification) and Image Pro plus. The data were analyzed stastically by one-way ANOVA and Scheffe test. The data were as follows: 1. The mean leakage was $0.725{\pm}1.167$ for group A, $0.813{\pm}0.921$ for group B, $0.809{\pm}0.997$ for group C, $1.111{\pm}1.147$ for group D, but no significant difference among them(p>0.05). 2. Lateral condensation had better sealing ability than continuous wave of condensation, but no significant difference among them(p>0.05). 3. There was no significant difference between root canal curvature degree and microleakage(p>0.05).

  • PDF

A Study on Generation and Operation of Dynamic Pattern at Micro-stereolithography using $DMD^{TM}$ ($DMD^{TM}$를 이용한 마이크로 광 조형 시스템에서 다이나믹 패턴 생성 및 구동에 관한 연구)

  • Kim H.S.;Choi J.W.;Ha Y.M.;Kwon B.H.;Won M.H.;Lee S.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1214-1218
    • /
    • 2005
  • As demands for precision parts are increased, existing methods to fabricate them such as MEMS, LIGA technology have the technical limitations like high precision, high functionality and ultra miniaturization. A micro-stereolithography technology based on $DMD^{TM}$(Digital Micromirror Device) can meet these demands. In this technology, STL file is the standard format as the same of conventional rapid prototyping system, and 3D part is fabricated by stacking layers that are sliced as 2D section from STL file. Whereas in conventional method, the resin surface is cured as scanning laser beam spot according to the section shape, but in this research, we use integral process which enables to cure the resin surface at one time. In this paper, we deal with the dynamic pattern generation and $DMD^{TM}$ operation to fabricate micro structures. Firstly, we address effective slicing method of STL file, conversion to bitmap, and dynamic pattern generation. Secondly, we suggest $DMD^{TM}$ operation and optimal support manufacturing for $DMD^{TM}$ mounting. Thirdly, we examine the problems on continuous stacking layers, and their improvements in software aspects.

  • PDF

Development and evaluation of a model for management of plant pests in organic cucumber cultivation

  • Ko, S.J.;Kang, B.R.;Kim, D.I.;Choi, D.S.;Kim, S.G.;Kim, H.K.;Kim, H.J.;Choi, K.J.;Kim, Y.C.
    • Korean Journal of Organic Agriculture
    • /
    • v.19 no.spc
    • /
    • pp.263-266
    • /
    • 2011
  • Crop protection strategies in organic horticulture aim to prevent insect pest and plant disease problems through utilization of non-chemical based control means. In order to develop a model for management of plant diseases and insects in organic cucumber cultivation, we compared efficacies between chemical pesticide spraying system and biological control means in semi-forcing and retarding cucumber cultivation during 2005 and 2006. Conventional chemical spray program using various chemical pesticides was applied 5 - 10 days intervals, while two different non-chemical pesticide application programs using two formulated biopesticides Topseed$^{TM}$ and Q-fect$^{TM}$, Suncho$^{TM}$, and Sangsungje$^{TM}$ (biocontrol agents 1) and using egg-yolk and cooking oil(EYCO), Bordeaux mixture, Suncho$^{TM}$, and Sangsungje$^{TM}$ (biocontrol agents 2) were applied 5 - 7 days intervals during entire cucumber cultivation period. Efficacy of both biocontrol agents programs was effective to comparable to conventional chemical pesitice spray program to control plant diseases such as powdery mildew and downy mildew as well as insect pests such as aphids and thrips which are known as major threats in cucumber organic cultivation. In this study, we established and evaluated an effective and economic crop protection strategy using various biological resources can be used to control plant diseases and pests simultaneously in organic cucumber cultivation field.

The Study on the Marine Eco-toxicity and Ecological Risk of Treated Discharge Water from Ballast Water Management System Using Electrolysis (전기분해원리를 이용한 선박평형수관리장치의 배출수에 대한 해양생태독성 및 해양환경위해성에 관한 연구)

  • Shon, M.B.;Son, M.H.;Lee, J.;Son, Y.J.;Lee, G.H.;Moon, C.H.;Kim, Y.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.88-101
    • /
    • 2013
  • The International Convention for the Control and Management of Ship's Ballast Water and Sediments was adopted at 2004 and then various BWMS (ballast water management system) have been developed. In this study, WET (whole effluent toxicity) test with algae (diatom) Skeletonema costatum as primary producer, invertebrate (rotifera) Brachionus plicatilis as 1st consumer and fish (olive flounder) Paralichthys olivaceus as predator, chemical analysis and ERA (environmental risk assessment) were conducted to assess the unacceptable effect on marine ecosystem by emitting the discharge water treated with AquaStar$^{TM}$ BWMS using electrolysis as main treatment equipment for removing the marine organisms in the ship's ballast water. The most sensitive test organism on discharge water treated with AquaStar$^{TM}$ BWMS was S. costatum that gave the NOEC value of 25.00%, LOEC value of 50.00% and 72hr-$EC_{50}$ value of 69.97% from WET test result for 20 psu salinity treated discharge water. NOEC and LOEC value of B. plicatilis and P. olivaceus exposed at 20 psu salinity treated discharge water were 50.00% and 100.00%, respectively. In the chemical analysis results, total number of substances produced by AquaStar$^{TM}$ BWMS was 18 which were bromate, 7 volatile halogenated organic compounds, 7 halogenated acetic acids, 3 halogenated acetonitriles and chloropicrin. Eighteen substances did not consider as persistence and bioaccumulative chemicals. Uncertainty of toxic property of 18 substances was high. PECs of 18 substances calculated by MAMPEC model were ranged from $4.58{\times}10^{-4}$ to $4.87{\mu}g\;L^{-1}$, PNECs of them were ranged from $1.6{\times}10^{-2}$ to $3.2{\times}10^2{\mu}g\;L^{-1}$. And, the PEC/PNEC ratio of 18 substances did not exceed 1. Therefore, ERA for produced substances indicate that the discharge water treated with AquaStar$^{TM}$ BWMS does not pose unacceptable effect on marine life. And $EC_{50}$ value of S. costatum on discharge water treated by BWMS using the electrolysis had positive correlation with initial TRO concentration, concentration and kind & level of HAAs.

Pharmacokinetic Evaluation of Ketorolac Tromethamine Sustained-Release Pellets after Oral Administration in Rabbits (케토롤락트로메타민 서방성 펠렛의 약물속도론적 평가)

  • Kwak, Son-Hyok;Hwang, Sung-Joo;Jiang, Ge;Nam, Kyung-Wan;Moon, Young-Girl;Lee, Hai-Bang;Cho, Sun-Hang;Yuk, Soon-Hong;Lee, Han-Koo;Jeong, Sang-Young;Lee, Young-Won
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.241-246
    • /
    • 2000
  • To develop a sustained-release preparation containing ketorolac tromethamine, two sustained-release pellet formulations were evaluated with a pharmacokinetic study as compared with a conventional commercial tablets (10 mg $Tarasyn^{TM}$, Roche Korea Ltd.). Two sustained-release formulations were as follows; formulation A was composed of an inner layer containing 75% of drug coated with $Eudragit^{TM}$ RS 100 membrane and an outer layer containing 25% of drug mixed with $Eudragit^{TM}$ NE30D, and formulation B was composed of only an inner layer containing 100% of drug coated with $Eudragit^{TM}$ RS 100 membrane. The dissolution test was performed for two formulations. In case of conventional tablets, 2.5 mg of drug per a dose was administered orally into male Albino rabbit (2.0-2.3 kg of body weight) 3 times at intervals of 4 hours. In case of two sustained formulations, 7.5 mg of drug was administered once orally. Blood samples were withdrawn periodically after the administration, and the blood concentration was determined by HPLC. The conventional tablets showed very high peak-trough fluctuation between administered doses, but two sustained formulations showed less fluctuation. Formulation A with the loading dose showed the time to reach minimum effective concentration (MEC) i.e. the onset time was less than 20 min, while Formulation B had more than 1 hr of the onset time. Formulation A had the more constant plasma level than formulation B. However, formulation B had a time lag, so the plasma level was less than MEC for an initial period of 1 hr. In formulation A, the plasma level was maintained within the therapeutic window $(0.3-5\;{\mu}g/ml)$ for a long period. Formulation A was thought to be an ideal sustained-release formulation for ketorolac tromethamine oral delivery system.

  • PDF

A CONFOCAL MICROSCOPIC STUDY ON DENTINAL INFILTRATION OF ONE-BOTTLE ADHESIVE SYSTEMS AND SELF-ETCHING PRIMING SYSTEM BONDED TO CLASS V CAVITIES (제 5급 와동에서의 단일용기 상아질 접착제와 자가 산부식 접착제의 상아질에 대한 침투도 평가)

  • Kim, Hyung-Su;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.3
    • /
    • pp.257-269
    • /
    • 2002
  • Objective : The purpose of this study was to evaluate the resin infiltration into dentin of one-bottle adhesive systems and self-etching primer bonded to Class V cavities using confocal laser scanning microscope(CLSM). Material and Methods : Forty Class V cavities were prepared from freshly extracted caries-free Human teeth. These teeth were divided into two groups based on the presence of cervical abrasion: Group I, cervical abrasion : Group II, wedge-shaped cavity preparation. Resin-dentin interfaces were produced with two one-bottle dentin bonding systems-ONE COAT BOND(OCB; Coltene$^R$) and Syntac$^R$SPrint$^{TM}$(SS; VIVADENT)-, one self-etching priming system-CLEARFIL$^{TM}$ SE BOND (SB : KURARAY)- and one multi-step dentin bonding system-Scotchbond$^{TM}$Multi-Purpose (SBMP, 3M Dental Products)-as control according to manufacturers' instructions. Cavities were restored with Spectrum$^{R}$(Dentsply). Specimens were immersed in saline for 24 hours and sectioned longitudinally with a low-speed diamond disc. The resin-dentin interfaces were microscopically observed using CLSM. The quality of resin-infiltrated dentin layers were evaluated by five dentists using 0~4 scale. Results : Confocal laser scanning microscopal investigations using primer labeled with rhodamine B showed that the penetration of the primer occurred along the cavity margins. Statistical analysis using one-way ANOVA followed by Duncan's Multiple Range test revealed that the primer penetration of the group 2(wedge-shaped cavity preparation) was more effective than group 1(cervical abrasion) and that of the gingival interfaces was more effective than the occlusal interfaces. In the one-bottle dentin bonding systems, the resin penetration score of OCB was compatible to SBMP, but those of SS and self-etching priming system, SB were lower than SBMP.

DESIGN AND FABRICATION OF S-BAND DIPLEXER FOR LEO TT&C APPLICATION (저궤도 위성 관제용 S-대역 다이플렉서 설계 및 제작)

  • Ahn, Sang-Il;Park, Dong-Chul
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.397-408
    • /
    • 2007
  • Diplexer is one of core devices needed to communicate with satellite using single ground antenna by separating uplink and downlink signal. This paper presents the design of the S-band diplexer for LEO TT&C application, especially for KOMPSAT (KOrea Multi-Purpose SATellite). To cope with requirements such as high handling power, low insertion loss, air-cavity resonator with high quality factor was considered as one of design drivers. Design was started with predicting unloaded Q and equivalent circuit from the structure of air-cavity resonator. For the convenience of adjustment, the coupling factor placed between resonators was estimated from COTSEM (Electro-Magnetic) simulator, EESOF $ADS^{TM}$, and expressed with 2-order polynomial regression. To improve the isolation between transmitting part (Tx) and receiving part (Rx), the inductive and capacitive attenuation poles were inserted between $4^{th}\;and\;6^{th}$ resonator respectively. The fabricated diplexer consists of two bandpass filters and each filter has eight resonants. From the measurement, it was shown that major requirements such as 0.5dB of insertion loss, 20dB of return loss and 100dB of isolation were fully satisfied within passband.