• Title/Summary/Keyword: Syringe

Search Result 360, Processing Time 0.022 seconds

On Effluent Concentration and Time of Fading Out of Carbon Monoxide and Sulful Dioxide in Atmosphere (대기중(大氣中) 배출(排出)된 일산화탄소(一酸化炭素)와 아황산(亞黃酸)가스의 지속시간(持續時間))

  • Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.373-375
    • /
    • 1974
  • The concentration of Carton momoxide(CO) and Sulful dioxide($SO_2$) by burning time of coal, and its time of fading out in atmosphere after effluence from stove were measured with Kitagawa gas detector, January, 1974. Gas for measurement was sampled by gas syringe at the point distanced 60cm. from first junction of garvanized pipe of stove. CO concentration was directly proportional to the burning temperature of coal but $SO_2$ was generally constant durning burning time or also in proportion to burning temperature. CO gas of effluent mixed with air(relative humidity, 40%) was maintained for long period relatively, but $SO_2$ gas was early faded out within short time. The period decreasing to allowable limit was about 4 days in former and about 30 minutes in later, respectiively.

  • PDF

Characteristics of Surface Lamination according to Nozzle Position in Liquid Direct Writing SFF (액체 재료 직접주사방식 SFF에서 노즐 위치에 따른 적층 특성)

  • Jung, Hung Jun;Lee, In Hwan;Kim, Ho-Chan;Cho, Hae Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.41-48
    • /
    • 2014
  • Direct writing(DW) is a method of patterning materials to a substrate directly, without a mask. It can use a variety of materials and be applied to various fields. Among DW systems, the flow-based type, using a syringe pump and nozzle, is simpler than other types. Furthermore, the range of materials is exceptionally wide. In additive processes, a three dimensional structure is made of stacking layer. Each layer is made of several lines. In this regard, good surface roughness of fabricated layers is essential to three dimensional fabrication. The surface roughness of any fabricated layer tends to change with the dispensing pattern. When multiple layers fabricated by a nozzle dispensing system are stacked, control of the nozzle position from the substrate is important in order to avoid interference between the nozzle and the fabricated layer. In this study, a fluid direct writing system for three dimensional structure fabrication was developed. Experimentsto control the position of the nozzle from substrate were conducted in order to examine the characteristics of the material used in this system.

Development of Solenoid RF coil for 4.7 T Magnetic Resonance Velocimeter to Improve Resolution (해상도 향상을 위한 4.7 T 자기공명유속계 용 솔레노이드 RF 코일 개발)

  • Yang, Byungkuen;Cho, Jee-Hyun;Song, Simon
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.40-45
    • /
    • 2016
  • Magnetic resonance velocimeter (MRV) is a powerful tool to non-invasively measure the velocity of a fluid flow in various fields ranging from medicine to engineering. However, since the demands for accurate measurement in the solid/liquid interface for cardiovascular diseases and porous media increase, the improvement of spatial resolution is required. In this study, a solenoid RF coil is developed for high spatial resolution measurement. The signal-to-noise ratio in solenoid RF coil is increased seventeen times better than that in commercial coil. Moreover, the velocity distribution of Hagen-Poiseuille flow is measured with in-plane resolution of $36{\mu}m$ by $36{\mu}m$ and the accuracy of the measured velocity is compared with theoretical distribution of the laminar flow. Flow rate calculated by MRV is estimated with the flow rate injected by syringe pump.

Application of new external total ring prostheses made by drip chamber of intravenous administration set in normal dogs (정상 견에서 수액세트 점적통을 이용한 새로운 기관 외부 보철링의 적용)

  • Jeong, Sang-hyi;Jeong, Soon-wuk
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.137-141
    • /
    • 2004
  • The purpose of this study was to compare easiness of application of polypropylene external total ring prosthesis (PPTRP, Group A) with that of polyvinylchloride external total ring prosthesis (PVCTRP, Group B), which were used for surgical correction of tracheal collapse in dogs. PPTRP was made from 3 ml syringe and PVCTRP from the drip chamber of intravenous administration set. Prostheses of group A (n=5) and B (n=5) were placed to cervical trachea in clinically normal 10 dogs, respectively weighing between 4 kg and 6 kg. There were mild coughing and swelling in one to three dogs of both groups for 3 days after surgery. No exercise intolerance was observed in both groups after surgery. There were no different results of clinical signs and radiographic views after surgery between group A and group B. The time (mean${\pm}$SD) to make total ring prosthesis, group A took $23.2{\pm}1.9$ minutes which was remarkably longer than that $(4.6{\pm}0.3)$ of group B. Also, the time to place around trachea, group A required $61.8{\pm}8.8$ minutes and group B $38.4{\pm}8.0$ minutes. Conclusionly, PVCTRP was timesaving and easier to make, fix, and suture than those of PPTRP. PVCTRP may be used alternatively to PPTRP for the tracheal collapse to treat in dogs.

Effect of Hexane Extract of Galla Rhois on Inflammatory Alveolar Bone Loss

  • Kim, Hyun-Jin
    • International Journal of Oral Biology
    • /
    • v.41 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • One of functions of Galla Rhois (GR) is reportedly an anti-inflammatory effect on the several inflammatory diseases. However, an effect of GR related to periodontitis has not been investigated. In the present study, we examined the effect of the hexane extract of Galla Rhois (GR-H) on periodontitis. Cytotoxicity was assessed by MTS analysis using human gingival fibroblast (hGF) cells. Experimental periodontitis was induced by injecting E.coli LPS into the palatal gingiva maxillary molar thrice weekly for 3 weeks (LPS group). GR-H diluted in 1xPBS was orally administrated using a syringe at 30 mg/kg body weight and 100 mg/kg body weight once a day (GR-H group). GR-H effect on the alveolar bone loss (ABL) was digitized with a micro-CT. GR-H treatment at concentrations exceeding 0.5 mg/ml showed cytotoxic effect in hGF cells. The micro-CT among groups were presented for the different distances from cemento-enamel junction (CEJ) to alveolar bone crest (ABC). The results indicated an inhibitory effect on alveolar bone loss for orally administered GR-H in a model of LPS-induced periodontitis.

A Study on the Characteristics of NOx Reduction by Urea-SCR System for a Light-Duty Diesel Engine (Urea-SCR 시스템에 의한 소형 디젤엔진의 NOx 저감 특성에 관한 연구)

  • Nam, Jeong-Gil;Lee, Don-Chool;Choi, Joo-Yol;Choi, Jae-Sung
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.521-527
    • /
    • 2005
  • The effects of an urae injection at the exhaust pipe for a 4-cylinder DI(Direct Injection) diesel engine are investigated experimentally. The urea quantity was controlled by NOx quantity and MAF(Manifold Air Flow). The urea injection must be precisely metered and then I used the urea syringe pump. I have tested 4 kinds of items that were with the EGR base engine and without the EGR engine. Then I tested each urea-SCR(Selective Catalytic Reduction) system. As the results, I can caculate the SUF(Stoichiometric Urea Flow) and visualize the NOx results by variation of engine speed and engine load. Also, I can make the NOx map. Therfore, I knew that NOx reduction effects of the urea-SCR system without the EGR engine were better than the with EGR base engine except of low load and low speed.

  • PDF

High Spinal Block following Epidural Block for Postoperative Pain Control -A case report- (수술후 통증조절을 위한 경막외 차단후 발생한 고위척추차단 -증례 보고-)

  • Chung, Sung-Su;Yoo, Kyung-Yeon;Chae, Young-Mi
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.260-263
    • /
    • 1996
  • High spinal block is a rare complication during epidural block, but it may result in serious events. 56-year-old man with gall stones was scheduled for cholecystectomy under general anesthesia. After operation, lumbar epidural catheterization was done at $T_{8-9}$ interspace for postoperative pain control. At the recovery room, initial bolus drug (0.1% bupivacaine 10 ml containing fentanyl $100{\mu}g$) was administered via epidural catheter and observed carefully. 15 minutes later, hypotension and bradycardia ouccurred. Hartman' solution was administered rapidly and ephedrine 5 mg was injected. 30 minutes after drug administration, loss of consciousness and respiratory arrest developed. Tracheal intubation was done immediately. Cardiovascular and respiratory functions were monitored continuously. The location of intrathecal catheter was confirmed by cerebrospinal fluid (CSF) seen in syringe after aspiration of catheter. The patient recovered gradually and was placed in the ward 4 hours after drug administration, without any problems. He was discharged 1 week later in good health.

  • PDF

Comparison of Anesthesiologist Controlled Sedation and Patient Controlled Sedation during Neurolytic Pain Block and Regional Anesthesia (통증치료를 위한 신경차단과 부위 마취시 Anesthesiologist Controlled Sedation과 Patient Controlled Sedation의 비교)

  • Kim, Ik-Gon
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.199-204
    • /
    • 1994
  • The purpose of this study is to evaluate the feasibility, advantages/disadvantages of patient-controlled sedation (PCS) compared to anesthesiologist-controlled sedation (ACS) during neurolytic pain block and regional anesthesia. Forty patients were divided randomly into two groups of 20 patients each. Group 1(ACS) received 0.01 $mg{\cdot}kg^{-1}$ intravenous midazolam and 0.5 ${\mu}g{\cdot}kg^{-1}$ fentanyl intravenously by anesthesiologist just before, 30, and 60 minutes after the procedure to acheive sedation; Group 2 (PCS) patients self-administered a mixture of midazolam (0.4 mg) and fentanyl ($20{\mu}g$) using a syringe type infusion pump (Terumo, Japan) to acheive sedation. Considering the dermographics of patients, the types and durations of procedure performed, the level of average sedation the comfort level were similar in both groups. But the doses of midazolam and fentanyl administerd in group 2 were smaller than those in group 1 (p<0.01). Patients in PCS group showed their level of sedation more proper than did those in ACS group. However, patients in ACS group rated their level of comfort higher than did those in PCS group. The findings of this study indicate that PCS using a combination of midazolam and fentanyl is a fafe and effective technique. More studies are, however, needed to determinc the best choice of drug(s), doses, lock-out intervals, and possible use of continuous infusion with patient-controlled sedation.

  • PDF

Changes in Pressure-Flow Control Characteristics of Shunt Valves by Intracranial Pressure Pulsation: an In Vitro Study

  • Lee, Chong-Sun;Kim, Joo-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.4
    • /
    • pp.193-197
    • /
    • 2005
  • Shunt valves used to treat patients with hydrocephalus were tested to investigate influence of intracranial pressure pulsation on their flow control characteristics. Five commercial shunt valves were tested in the flow loop that simulates pulsed flow under pressure pulsation. As 20cc/hr of flow rate was adjusted at a constant pressure, application of $40mmH_2O$ of pressure pulse increased the flow rate by $67.9\%.$ As a 90cm length catheter was connected to the valve outlet, increase in the flow rate was substantially reduced to $17.5\%.$ As the flow rate was adjusted to 40cc/hr at a constant pressure, increase in the flow rate was $51.1\%$ with the same pressure pulsation of $40mmH_2O$. The results indicated that pressure-flow control characteristics of shunt valves implanted above human brain ventricle is quite different from those obtained by syringe pump test at constant pressures right after manufacture. The influence of pressure pulsation was observed to be more significant at low flow rate and the flexibility of the outlet silicone catheter was estimated to significantly reduce flow increase due to pressure pulsation.

The concentration differences of dental caries induced organic acids which are produced after intake of sucrose and carbonated drinks (자당 및 탄산음료 섭취 후 생성되는 구강 내 치아우식 유발성 유기산의 농도 차이)

  • Park, Jung-Eun;Jang, Jong-Hwa
    • Journal of Korean society of Dental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.381-394
    • /
    • 2017
  • Objectives: This study aims to evaluate carbonated drinks induced dental caries with qualitative analysis and to compare with oral organic acids including lactate, acetate, propionate, formate, butyrate, pyruvate and valerate which cause caries when taking either 10% sucrose drinks or carbonated drinks. Methods: Saliva was collected from six study subjects before and after (start, 5, 10, 30 minutes) taking water intake upon (A) 10% sucrose intake, (B) 10% sucrose intake, and (C) carbonated drink intake, then they were centrifuged at 1,200 rpm followed by removing bacteria and enzymes with syringe filtering, performing a qualitative analysis with HPLC conductivity detection (GP50 gradient pump, ED 50 detector) after saliva pre-treatment under isocratic 100 mM NaOH mobile phase. Results: Higher risk of dental caries was evaluated in order of C>B>A, with the results of total oral organic acids' concentration, lactates of organic acids and organic acids produced after 5 minutes from the 3 types of drinks intake. Conclusions: Carbonated beverages were estimated to develop higher dental caries induction than beverages containing 10% sucrose because of the high organic acid concentration in the mouth after its intake.