• 제목/요약/키워드: Synthetic wastewater

검색결과 340건 처리시간 0.027초

군용시설물(軍用施設物) 폐수처리(廢水處理)를 위한 고정생물막공법(固定生物膜工法)의 연구(硏究) (A Study on the Aerated Submerged Fixed-Film Bioreactor for Military Installation Wastewater Treatment)

  • 서형석;유성호
    • 상하수도학회지
    • /
    • 제7권1호
    • /
    • pp.37-45
    • /
    • 1993
  • This research was performed to examined the applicability of a fixed-biofilm process for the wastewater treatment of military installations. Utilizing plastic net media, synthetic wastewater-average $BOD_5$ cocentration was $192mg/l$ treated in the three sets of reactors that have 8 hours, 6 hours, and 4 hours of hydraulic retention time. The results of this experiment showed that the biofilm was not detached easily, and the reactor was not closed by excess biomass. The average soluble $BOD_5$ concentrations of effluent were $6.0mg/l$ with 8 hours of retention time, $11.3mg/l$ with 6 hours of retention time, and $19.4mg/l$ with 4 hours of retention time. Especially it was reduced to $5.7mg/l$ in the second stage reactor with 4 hours of retention time. These resulted that the fixed-biofilm process could be adapted for the treatment of military installation wastewater.

  • PDF

미세조류를 이용한 오·폐수 영양염류 제거효율 평가 (Evaluation of Nutrients Removal Efficiency in Effluents of Sewage and Wastewater using Microalgae)

  • 김숙찬;김한순
    • 생태와환경
    • /
    • 제50권2호
    • /
    • pp.187-194
    • /
    • 2017
  • 본 연구는 경상북도에 위치한 하천과 호소에서 채집한 미세조류의 배양실험을 통해 영양염류 제거에 유용한 미세조류를 탐색하고, 실제 배출되는 폐수, 개인하수 및 가축분뇨 방류수에 미세조류를 접종하여 질소와 인 제거효율을 평가하고자 하였다. 조류를 채집하여 예비 배양조에서 배양한 미세조류 군집의 우점종은 Monoraphidium contortum, Scenedesmus acutus, Coelastrum microporum, Chlorella sp.로 나타났으며, 4000 Lux와 8000 Lux 조도에서 인공폐수를 배양액으로 배양한 미세조류 군집의 우점종은 Chlorella sp., Scenedesmus obliquus로 나타났다. 8000 Lux 조도에서 $NO_3-N$ 제거율은 63.0%~83.6%로 나타났고, 4000 Lux 조도에서 $NO_3-N$ 제거율은 27.2%~88.1%로 나타났다. 4000 Lux와 8000 Lux 조도에서 $PO_4-P$의 제거율은 95.3% 이상으로 $NO_3-N$의 제거율보다 높게 나타났다. $NO_3-N$$PO_4-P$의 제거 효율은 $1.0{\times}10^6cells\;mL^{-1}$ 농도로 접종하였을 때 $1.0{\times}10^5cells\;mL^{-1}$$1.0{\times}10^7cells\;mL^{-1}$ 농도로 접종하였을 때 보다 높게 나타났다. 미세조류를 이용한 인공폐수에서의 TN과 TP 제거율은 각각 94.9%과 90.0%로 나타났으며, TN과 TP 제거속도는 $1.961mg\;L^{-1}\;day^{-1}$, $0.200mg\;L^{-1}\;day^{-1}$로 나타났다. 실험에 사용된 모든 폐수에서 미세조류를 이용하여 영양염류가 제거되었고, 그중 개인하수 방류수가 영양염류 제거율이 가장 높게 나타났다.

역 유동층 생물막 반응기를 이용한 유분함유폐수 처리에 관한 연구 (A study on the treatment of highly-emulsified oily wastewater by an inverse fluidized-bed biofilm reactor)

  • 최윤찬;나영수
    • 한국환경과학회지
    • /
    • 제5권3호
    • /
    • pp.361-367
    • /
    • 1996
  • An inverse fluidized-bed biofilm reactor (IFBBR) was used for the treatment of highly-emulsified oily wastewater. When the concentration of biomass which was cultivated in the synthetic wastewater reached to 6000 mg/1, the oily wastewater was employed to the reactor with a input COD concentration range of 50 mg/1 to 1900 mg/l. Virtually the IFBBR showed a high stability during the long operation period although soma fluctuation was observed. The COD removal efficiency was maintained over 9% under the condition that organic loading rate should be controlled under the value of 1.5 kgCOD/$m^3$/day, and F/M ratio is 1.0 kgCOD/kgVSS/day at $22{\circ}C$ and HRT of 12 hrs. As increasing organic loading rates, the biomass concentration was decreased steadily with decreasing of biofilm dry density rather than biofilm thickness. Based on the experimental jesuits, it was suggested that the decrease in biofilm dry density was caused by a loss of biomass inside the biofilm.

  • PDF

다양한 난분해성 방향족 탄화수소를 분해하는 pseudomonas 개발균주의 폐수에의 적용 (Application of the genetically engineered strains of pseudomonas degrading various persistent aromatic hydrocarbons to wastewater)

  • 송재욱;박경량;박용근;이영록
    • 미생물학회지
    • /
    • 제28권3호
    • /
    • pp.243-248
    • /
    • 1990
  • Genetically engineered strains of Pseudomonas, which could degrade the various aromatic hydrocarbons, were acclimated to the synthetic wastewater with increasing substrate concentration. All of the tested strains except KUD101 showed 70-90% of the COD removal efficiencies. Acclimated strains, Pseudomonas putida KUD106, KUD107 and KUD108 were inoculated into the ordinary activated sludge and these sludges were used in the dyeing or alkylbenzene wastewater treatment system. In the case of the wastewater containing alkylbenzene compounds, COD removal efficiency was 12-14% higher than that of the ordinary activated sludge, while it was not effective for dyeing wastewater. On the other hand, the floc formation of the activated sludge inoculated with genetically engineered strains was more rapid in both wastewaters tested than that of the activated sludge by the ordinary natural strains.

  • PDF

합류식 하수관거 월류수 처리를 위한 섬유사 여과 장치의 처리특성 (Performance of fiber media filter device for combined sewer overflows treatment)

  • 손상미;주티담롱판;박기영;박철휘
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.231-236
    • /
    • 2010
  • A compressible media filtration process with synthetic fiber media was studied for combined sewer overflows (CSOs) treatment. Since the operation performance of fiber media filtration was dependent on the pattern of CSOs, the flow rate of CSOs was investigated and it was characterized by a big fluctuation. Thus, in this study, the fiber media filtration process was tested with wide range of filtration velocity. The removal efficiency was proportion to the increase in compressibility. As the filtration velocity was increased, the treatment efficiency was decreased and consequently leveled off when the velocity exceeded 750 $m^3/m^2$/d. An exponential equation was introduced to express the relationship between the removal efficiency and up-flow velocity. At columm test, six repetition of filtration and backwash cycle did not after the filtering velocity under the constant pressure condition.

Removal of a synthetic broad-spectrum antimicrobial agent, triclosan, in wastewater treatment systems: A short review

  • Lee, Do Gyun
    • Environmental Engineering Research
    • /
    • 제20권2호
    • /
    • pp.111-120
    • /
    • 2015
  • Contaminants of emerging concern (CECs) including endocrine disrupting compounds (EDCs) and pharmaceuticals and personal care product chemicals (PPCPs) have recently received more attention because of their occurrence in water bodies and harmful impacts on human health and aquatic organisms. Triclosan is widely used as a synthetic broad-spectrum antimicrobial agent due to its antimicrobial efficacy. However, triclosan detected in aquatic environment has been recently considered as one of CECs, because of the potential for endocrine disruption, the formation of toxic by-products and the development of cross-resistance to antibiotics in aquatic environment. This comprehensive review focuses on the regulations, toxicology, fate and transport, occurrence and removal efficiency of triclosan. Overall, this review aims to provide better understanding of triclosan and insight into application of biological treatment process as an efficient method for triclosan removal.

Bone Charcoal에 의한 폐수증의 중금속 흡착특성 (Adsorption Characteristics of Heavy Metals in Wastewater on Bone Charcoal)

  • 정팔진;곽동희;이재욱
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.555-563
    • /
    • 2000
  • The study was conducted to evaluate the adsorption equilibrium of heavy metals on bone charcoal made of livestock bone which was sintered at $550{\sim}600^{\circ}C$. Analysis of bone charcoal by XRD and FT-IR showed that crystal structure was similar to that of synthetic hydroxyapatite. Adsorption equilibrium capacity of single component (Pb, Cd, and Zn) on bone charcoal could be expressed as Langmuir, Freundlich, and Sips equations. Sips isotherm was best among the three isotherms. The values predicted by IAST(ideal adsorbed solution theory) showed good relationship to the experimental data in multicomponent adsorption equilibrium. Adsorption affinity was in order of Pb, Cd, and Zn. The order was same in case of activated carbon or synthetic hydroxyapatite. Through the study results. it would be expected that bone charcoal made of livestock could be used in field of wastewater treatment plants as adsorbent to remove heavy metal.

  • PDF

평판형 막모듈을 이용한 합성염료 폐수처리에 있어서 염농도 및 온도의 영향 (Effect of Salt Concentration and Temperature in Synthetic Dyestuff Wastewater Treatment using Plate and Frame Membrane Module)

  • 김선일;이봉우;윤영재
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.209-216
    • /
    • 1998
  • Nanofiltration[NF45] and reverse osmosis membrane(HR98PP) separation treatment of dyestuff wastewater was carried out In order to separate relatively pure water from synthetic dyestuff wastewater, which consists of reactive dye, acid dye, basic dye, direct dye, and disperse dye. The experiments were performed by using the plate and frame membrane module. In the nanofiltration and reverse osmosis membrane separation, When the NaCl concentration was 0.1, 5.0, and 20.091, retention was 63.0, 46.0, 0.9%, respectively. When permeate flux was 125.0, 67.5, and 45.0 L/$m^2$ h, the osmotic pressure increased with Increasing the NaCl concentration. Permeate flux of two membranes Increased as temperature Increased due to segmental movement of polymer of the membrane and the rejection rate of dyestuff was decreased gradually. It was found that the rejection rate was about 95% in the nanofiltratlon, while the reverse osmosis membrane showed a high rejection rate of 99% under all temperature and pressures conditions.

  • PDF

Biodegradation of Evercion Blue P-GR and Ostazin Black H-GRN in synthetic textile wastewater by membrane bioreactor system using Trametes versicolor

  • Gul, Ulkuye D.;Acikgoz, Caglayan;Ozan, Kadir
    • Advances in environmental research
    • /
    • 제9권2호
    • /
    • pp.85-95
    • /
    • 2020
  • In this study, the decolorization of Evercion Blue P-GR (EBP) and Ostazin Black H-GRN (OBH) was investigated using white-rot fungi named as Trametes versicolor (T. versicolor) by Membrane Bioreactor (MBR) system. This study involved experiments employing synthetic textile wastewater in Membrane Bioreactor (MBR) system (170 ml), initially inoculated with a pure culture of fungi, but operated, other than controlling pH (4.5±0.2) and temperature (25±1℃), under non-sterile conditions. The effect of dye concentrations on fungal biodegradation was also investigated. The decolorization efficiencies were 98%, 90%, and 87% respectively, for EBP when the initial dye concentration of 50, 100, and 200 mg L-1 were used. However, the decolorization percentages for OBH dye were obtained 95% for 50 mg L-1 dye solution in 2 days and 66% for 100 mg L-1 dye solution in 5 days. Possible interactions between dye molecules and the fungal surface were confirmed by SEM, EDX, and FTIR analyses.

Semi-batch Jet Loop Reactor에서 연소 배가스중 CO2를 이용한 알칼리 폐수 중화 (Neutralization of Synthetic Alkaline Wastewater with CO2 in a Semi-batch Jet Loop Reactor)

  • 손민기;성호진;이제근
    • 한국연소학회지
    • /
    • 제18권2호
    • /
    • pp.17-22
    • /
    • 2013
  • In this study, we tested the absorption of $CO_2$ in combustion gas into an alkaline wastewater to simultaneously control $CO_2$ and wastewater. During the experiment, we investigated the effects of operating parameters on neutralization characteristics of the wastewater by using $CO_2$ in a bench-scale semi-batch jet loop reactor (0.1 m diameter and 1.0 m in height). The operating parameters investigated in the study are gas flow rate of 1.0-2.0 L/min, liquid recirculation flow rate of 4-32 L/min, and liquid temperature of $20-25^{\circ}C$. It was shown that the initial pH of wastewater rapidly decreased with increased gas flow rate for a given liquid recirculation flow rate. This was due to the increase in the gas holdup and the interfacial area at higher gas flow rate in the reactor. At constant gas flow rate, the time required to neutralize the wastewater initial pH of 10.1 decreased with liquid recirculation flow rate ($Q_L$), reached a minimum value in the range of $Q_L$ = 16-24 L/min, and then increased with further increase in $Q_L$. Further, the time required to neutralize the wastewater was shortened at higher temperatures.