• Title/Summary/Keyword: Synchronous shift

Search Result 32, Processing Time 0.026 seconds

Phase Shift Controlled GM ZVS-MRC with Synchronous Rectifier (동기 정류기를 이용한 위상 변위 제어 클램프 모드 포워드 다중 공진형 컨버터)

  • Song, Jong-Hwa;Kim, Chang-Sun;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2016-2019
    • /
    • 1997
  • To solve the low efficiency problem of low-voltage power supplies, it has been studied to replace the schottky barrier diode with the MOSFET synchronous rectifier. In this paper, Phase Shift-Controlled Clamp Mode Zero Voltage Switching-Multi Resonant Converter with Synchronous Rectifier (PSC CM ZVS-MRC with SR) is presented to achieve high efficiency in low-voltage power supplies. The characteristics analysis of synchronous rectifier is established by using the MOSFET equivalent circuit and efficiency comparison is established between the Synchronous Rectifier and the schottky barrier diode. To verify the validity of the analysis, 33W(3.3V, 10A) PSC CM ZVS-MRC with self-driven synchronous rectifier at switching frequency of 1MHz is designed and tested. And it is confirmed that the experimental results are well consistent with the theoretical results. The maximum efficiency of the converter is 83.4% at full load, which is 3.3% higher than conventional schottky diode rectification.

  • PDF

ZVS Operating Range Extension Method for High-Efficient High Frequency Linked ZVS-PWM DC-DC Power Converter

  • Sato S.;Moisseev S.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.227-230
    • /
    • 2003
  • In this paper, a full bridge edge-resonant zero voltage mode based soft-switching PWM DC-DC power converter with a high frequency center tapped transformer link stage is presented from a practical point of view. The power MOSFETS operating as synchronous rectifier devices are implemented in the rectifier center tapped stage to reduce conduction power losses and also to extend the transformer primary side power MOSFETS ZVS commutation area from the rated to zero-load without a requirement of a magnetizing current. The steady-state operation of this phase-shift PWM controlled power converter is described in comparison with a conventional ZVS phase-shift PWM DC-DC converter using the diodes rectifier. Moreover, the experimental results of the switching power losses analysis are evaluated and discussed in this paper. The practical effectiveness of the ZVS phase-shift PWM DC-DC power converter treated here is actually proved by using 2.5kW-32kHz breadboard circuit. An actual efficiency of this converter is estimated in experiment and is achieved as 97$\%$ at maximum.

  • PDF

POSSIBILITIES TO IMPROVE TRANSIENT GEAR SHIFT NOISE (SHIFT CLONK) IN A PASSENGER CAR

  • BIERMANN J. W.;REITZ A.
    • International Journal of Automotive Technology
    • /
    • v.6 no.1
    • /
    • pp.23-28
    • /
    • 2005
  • The presented investigation of shift clonk in a vehicle with front-wheel drive shows how a detailed analysis of the complete acoustic system with respect to excitation, transfer and radiation foremost enables possibilities of noise reduction to be worked out. One of the most important basics for the shift clonk analysis was a synchronous measurement of both, torsional vibrations in the drive train on the excitation side as well as airborne and structure-borne noise signals on the transfer and radiation side. Thus, root causes could be identified and improvement measures of the internal shift system could be worked out. An analysis of the transfer paths by means of airborne and structure borne noise measurements made evident that the side shafts were responsible for the disturbing frequencies in the transfer paths. With the help of the FE-simulation it was possible to develop measures of structure optimisation for the side shaft system. The realisation of these measures clearly reduced the shift-noises in the vehicle interior.

Performance of M-ary Turbo Coded Synchronous FHSS Multiple Access Networks with Noncoherent MFSK under Rayleigh Fading Channels

  • Hong, Sungnam;Cheun, Kyungwhoon;Lim, Hyuntack;Cho, Sunghye
    • Journal of Communications and Networks
    • /
    • v.15 no.6
    • /
    • pp.601-605
    • /
    • 2013
  • The performance of M-ary turbo coded synchronous, fast frequency-hopping spread spectrum multiple-access (FHSS-MA) networks with M-ary frequency shift keying (MFSK) and noncoherent detection is analyzed under Rayleigh fading. Results indicate that M-ary turbo codes dramatically enhance the performance of FHSS-MA networks using MFSK compared to binary turbo codes.

An Upshift Improvement in the Quality of Forklift's Automatic Transmission by Learning Control (학습제어를 이용한 지게차 자동변속기 상향 변속품질 개선)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.19 no.2
    • /
    • pp.17-26
    • /
    • 2022
  • Recently, automatic transmissions caused a good improvement in the shift quality of a forklift. An advanced shift control algorithm, which was based on TCU firmware, was applied with embedded control technology and microcontrollers. In the clutch-to-clutch shifting, one friction element is released and the other friction element is activated. During this process, if the release and application timings are not synchronized, an overrun or tie-up occurs and ultimately leads to a shift shock. The TCU, which measures only the speed of the forklift, inevitably applies the open-loop shift control. In this situation, the speed ratio does not change during the clutch fill. The torque phase occurs until the clutch is disengaged. In this study, an offline shift logic of the learning control was proposed. It induced a synchronous shift when the learning control progressed. During this process, the reference current trajectory of the release clutch was corrected and applied to the next upshift. We considered the results of the overrun/tie-up characteristics of the upshift performed immediately before. The vehicle test proved that the deviation in shift quality, which was caused by the difference in the mechanical characteristics of the clutch, could be improved by the learning control.

Simulations of Two-Dimensional Electronic Correlation Spectra

  • Kim, Hak Jin;Jeon, Seong Jun
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.807-815
    • /
    • 2001
  • Two-dimensional (2D) correlation method, which generates the synchronous and the asynchronous 2D spectrum by complex cross correlation of the Fourier transformed spectra, is an analysis method for the changes of the sample spectrum induced by vari ous perturbations. In the present work, the 2D electronic correlation spectra have been simulated for the cases where the sample spectrum composed of two gaussian bands changes linearly. When only the band amplitudes of the sample spectrum change, the synchronous spectrum shows strong peaks at the band centers of the sample spectrum, but the asynchronous spectrum does not make peaks. When the sample spectrum shifts without changing intensity and width, the synchronous spectrum shows peaks around the initial and final positions of the band maximum and the asynchronous spectrum shows long peaks spanning the shifting range. The band width change produces the complex 2D correlation spectra. When the sample spectrum shifts with band broadening, the width change by 50% of full width at half maximum (FWHM) does not give so large an effect on the correlation spectrum as the spectral shift by one half of FWHM of the sample spectrum.

Phase-Shift Full-Bridge DC/DC Converter with Fixed-Phase Operation Inverter (고정 위상 동작 인버터를 포함하는 위상천이 풀 브리지 DC/DC 컨버터)

  • Kim, Jin-Ho;Park, Jae-Sung;Kim, Hong-Kwon;Park, Jun-Woo;Shin, Yong-Saeng;Ji, Sang-Keun;Cho, Sang-Ho;Roh, Chung-Wook;Hong, Sung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.131-137
    • /
    • 2013
  • In this paper, the phase-shift full-bridge DC/DC converter with fixed-phase operation inverter is proposed. The proposed circuit consists of two full-bridge inverters which are connected in parallel. While one full-bridge inverter operates as the fixed-phase, it regulates the output voltage by adjusting the phase of the other inverter. During the normal operation period, the proposed circuit makes the less amount of conduction loss of the primary switches and secondary synchronous rectifiers, as well as the less amount of the current ripple of the output inductor, than the conventional phase-shift full-bridge DC/DC converter does. Also, it achieves high efficiency by reducing the snubber loss of the secondary synchronous rectifier. To sum up, the present inquiry analyzes the theoretical characteristics of the proposed circuit, and shows the experimental results from a prototype for 450W power supply.

Performance and Transmission Efficiency Analysis of 2-Mode Hydro Mechanical Transmission (2-모드 기계유압식 무단변속기의 성능 및 전달효율해석)

  • Jung Gyuhong;Kim Hyoungeui;Kim Jongki
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.1
    • /
    • pp.90-98
    • /
    • 2005
  • HMT is a type of continuously variable transmission which has split power flow path characteristics with gear train and hydro static unit. The benefit of improved fuel economy and high power capacity enables it to be a promising application fur large vehicles. This paper presents the analysis results including velocity, static torque, transmission efficiency and dynamic model of the HMT that is developed for city buses. The speeds or gear shafts, the static clutch torque and split power ratio for each mode are detailed here. From the analysis of HMT transmission efficiency considering the power loss in meshed gear and hydraulic unit, we can conclude that minimization of hydraulic power is necessary for improved fuel economy design. Also, the dynamic simulation result for mode shift characteristics shows that little shift shock is observed because of the synchronized rotation speed in clutch.

Analysis and Design of a Three-Phase Synchronous Solid-state Var Compensator using Neutral-Point-Clamped Inverter (NPC 인버터를 이용한 3상 동기형 SVC의 해석 및 설계)

  • Lim, Su-Saeng;Lee, Eun-Woong;Kim, Sung-Heon;Lee, Dong-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.42-45
    • /
    • 1997
  • A synchronous solid-state var compensator(SSVC) system which employs a three-phase neutral-point-darned (NPC) inverter is presented and analyzed for high voltage and high power applications. The proposed SSVC system can compensate for leading and lagging displacement factor. An optimal pulse-width-modulation (PWM) is used as a means of reducing the size of reactive components. A equivalent model is obtained using DQ-transform, and the characteristic of open-loop system are archived from DC and AC analyzes. A $\alpha$ phase-shift control is suggested using a self-controlled dc bus.

  • PDF

High Density Cell Culture of Mucor sp. KCTC 8405P for Production of ${\gamma}-Linolenic$ Acid in Fed-Batch Culture

  • Park, Jong-Hyun;Shin, Hyun-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.1 no.2
    • /
    • pp.126-129
    • /
    • 1991
  • In order to produce ${\gamma}-linolenic$ acid by Mucor sp. KCTC 8405P. the fungus was cultivated in fed-batch culture with two phases. i.e., growth in yeast-like form and induction to hyphal growth by pH shift of the culture medium during cultivation. The synchronous growth of the fungus into the appropriate sizes was important for the high density cell culture of this dimorphic fungus. Dissolved oxygen concentration in the medium did not affect degree of unsaturation of fatty acids and ${\gamma}-linolenic$ acid content. Under the culture conditions applied in this experiment. the fungus was found to produce 100 g/l dry mycelia containing 40% of the lipids, where ${\gamma}-linolenic$ acid comprised about 9% of the total extractable fatty acids.

  • PDF