• Title/Summary/Keyword: Sync

Search Result 267, Processing Time 0.028 seconds

Case Study : Cinematography using Digital Human in Tiny Virtual Production (초소형 버추얼 프로덕션 환경에서 디지털 휴먼을 이용한 촬영 사례)

  • Jaeho Im;Minjung Jang;Sang Wook Chun;Subin Lee;Minsoo Park;Yujin Kim
    • Journal of the Korea Computer Graphics Society
    • /
    • v.29 no.3
    • /
    • pp.21-31
    • /
    • 2023
  • In this paper, we introduce a case study of cinematography using digital human in virtual production. This case study deals with the system overview of virtual production using LEDs and an efficient filming pipeline using digital human. Unlike virtual production using LEDs, which mainly project the background on LEDs, in this case, we use digital human as a virtual actor to film scenes communicating with a real actor. In addition, to film the dialogue scene between the real actor and the digital human using a real-time engine, we automatically generated speech animation of the digital human in advance by applying our Korean lip-sync technology based on audio and text. We verified this filming case by using a real-time engine to produce short drama content using real actor and digital human in an LED-based virtual production environment.

Multicontents Integrated Image Animation within Synthesis for Hiqh Quality Multimodal Video (고화질 멀티 모달 영상 합성을 통한 다중 콘텐츠 통합 애니메이션 방법)

  • Jae Seung Roh;Jinbeom Kang
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.4
    • /
    • pp.257-269
    • /
    • 2023
  • There is currently a burgeoning demand for image synthesis from photos and videos using deep learning models. Existing video synthesis models solely extract motion information from the provided video to generate animation effects on photos. However, these synthesis models encounter challenges in achieving accurate lip synchronization with the audio and maintaining the image quality of the synthesized output. To tackle these issues, this paper introduces a novel framework based on an image animation approach. Within this framework, upon receiving a photo, a video, and audio input, it produces an output that not only retains the unique characteristics of the individuals in the photo but also synchronizes their movements with the provided video, achieving lip synchronization with the audio. Furthermore, a super-resolution model is employed to enhance the quality and resolution of the synthesized output.

Effects of a High-Intensity Interval Physical Exercise Program on Cognition, Physical Performance, and Electroencephalogram Patterns in Korean Elderly People: A Pilot Study

  • Sun Min Lee;Muncheong Choi;Buong-O Chun;Kyunghwa Sun;Ki Sub Kim;Seung Wan Kang;Hong-Sun Song;So Young Moon
    • Dementia and Neurocognitive Disorders
    • /
    • v.21 no.3
    • /
    • pp.93-102
    • /
    • 2022
  • Background and Purpose: The effects of high-intensity interval training (HIIT) interventions on functional brain changes in older adults remain unclear. This preliminary study aimed to explore the effect of physical exercise intervention (PEI), including HIIT, on cognitive function, physical performance, and electroencephalogram patterns in Korean elderly people. Methods: We enrolled six non-dementia participants aged >65 years from a community health center. PEI was conducted at the community health center for 4 weeks, three times/week, and 50 min/day. PEI, including HIIT, involved aerobic exercise, resistance training (muscle strength), flexibility, and balance. Wilcoxon signed rank test was used for data analysis. Results: After the PEI, there was improvement in the 30-second sit-to-stand test result (16.2±7.0 times vs. 24.8±5.5 times, p=0.027), 2-minute stationary march result (98.3±27.2 times vs. 143.7±36.9 times, p=0.027), T-wall response time (104.2±55.8 seconds vs.71.0±19.4 seconds, p=0.028), memory score (89.6±21.6 vs. 111.0±19.1, p=0.028), executive function score (33.3±5.3 vs. 37.0±5.1, p=0.046), and total Literacy Independent Cognitive Assessment score (214.6±30.6 vs. 241.6±22.8, p=0.028). Electroencephalography demonstrated that the beta power in the frontal region was increased, while the theta power in the temporal region was decreased (all p<0.05). Conclusions: Our HIIT PEI program effectively improved cognitive function, physical fitness, and electroencephalographic markers in elderly individuals; thus, it could be beneficial for improving functional brain activity in this population.

Adverse Events in Total Artificial Heart for End-Stage Heart Failure: Insight From the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE)

  • Min Choon Tan;Yong Hao Yeo;Jia Wei Tham;Jian Liang Tan;Hee Kong Fong;Bryan E-Xin Tan;Kwan S Lee;Justin Z Lee
    • International Journal of Heart Failure
    • /
    • v.6 no.2
    • /
    • pp.76-81
    • /
    • 2024
  • Background and Objectives: Real-world clinical data, outside of clinical trials and expert centers, on adverse events related to the use of SyncCardia total artificial heart (TAH) remain limited. We aim to analyze adverse events related to the use of SynCardia TAH reported to the Food and Drug Administration (FDA)'s Manufacturers and User Defined Experience (MAUDE) database. Methods: We reviewed the FDA's MAUDE database for any adverse events involving the use of SynCardia TAH from 1/01/2012 to 9/30/2020. All the events were independently reviewed by three physicians. Results: A total of 1,512 adverse events were identified in 453 "injury and death" reports in the MAUDE database. The most common adverse events reported were infection (20.2%) and device malfunction (20.1%). These were followed by bleeding events (16.5%), respiratory failure (10.1%), cerebrovascular accident (CVA)/other neurological dysfunction (8.7%), renal dysfunction (7.5%), hepatic dysfunction (2.2%), thromboembolic events (1.8%), pericardial effusion (1.8%), and hemolysis (1%). Death was reported in 49.4% of all the reported cases (n=224/453). The most common cause of death was multiorgan failure (n=73, 32.6%), followed by CVA/other non-specific neurological dysfunction (n=44, 19.7%), sepsis (n=24, 10.7%), withdrawal of support (n=20, 8.9%), device malfunction (n=11, 4.9%), bleeding (n=7, 3.1%), respiratory failure (n=7, 3.1%), gastrointestinal disorder (n=6, 2.7%), and cardiomyopathy (n=3, 1.3%). Conclusions: Infection was the most common adverse event following the implantation of TAH. Most of the deaths reported were due to multiorgan failure. Early recognition and management of any possible adverse events after the TAH implantation are essential to improve the procedural outcome and patient survival.

Construction and Validation of a Data Synchronization Server supporting OMA DS Standards (OMA DS 표준을 지원하는 자료동기화 서버 구축 및 적합성 검증)

  • Pak, Ju-Geon;Park, Kee-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.5
    • /
    • pp.79-91
    • /
    • 2011
  • In this paper, a DS (Data Synchronization) server for mobile communication environments is constructed and the suitability and the performance of its operations are validated. The DS server provides a way to update the newest data and keep data consistency for clients (mobile devices). In addition, the DS server constructed in this paper supports various synchronization types, and detects all changes and conflicts. In case of data conflicts, the DS server resolves the conflicts according to the several policies implemented in this work. The DS server conforms to the OMA(Open Mobile Alliance) DS standard protocol for interoperability with other mobile devices and servers. In addition to the transmission-by record scheme proposed by the OMA DS standard protocol, the DS server constructed in this paper also provides the transmission-by field scheme for the enhancement transmission performance between the server and clients. In order to validate its operations, data synchronization between the DS server and the SCTS (SyncML Conformance Test Suit), the suitability validation tool provided by the OMA, is performed. The validation results show that the DS server constructed in this paper satisfies all of the test cases except the Large Object function. The Large Object function will be implemented later because the function is not needed for the personal information synchronization process which this paper aims for. Also, synchronization times of the DS server are measured while increasing the number of data and clients. The results of the performance evaluations demonstrate that the DS server is scalable, in the sense that it has not suffered from any serious bottlenecks with respect to the number of data and clients. We expect that this work will provide a framework for various studies in the future for improving mobile DS operations.

Effect of Earthing Mat on the Quality of Sleep (어싱매트가 수면의 질에 미치는 영향)

  • Yum, Byeong Soo;Park, Jae Beum;Kim, Ki-Youn
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.1
    • /
    • pp.103-109
    • /
    • 2020
  • Objectives: Using as a sleep evaluation tool the Pittsburgh Sleep Quality Index (PSQI), this paper studied the effects of earthing on the amount and quality of sleep by examining a patient population of people who used and did not use earthing mats and a group of general healthy people. Methods: From September to November 2019, 30 patients who voluntarily used an earthing mat, 40 patients who did not use an earthing mat, and 40 healthy people who did not use an earthing mat were selected. A questionnaire applying the PSQI (Pittsburgh Sleep Quality Index) after being translated into Korean was distributed starting November 29, 2019 to 110 subjects. Out of them, 101 subjects who completed the questionnaire were examined. All statistics used SPSS 25.0. Results: The first overall score showed that all three groups had problems sleeping, with five points or more, but the general population had better sleep quality than the patient group. It also showed that the using matgroup had better quality of sleep than the ones that did not use the earthing mat In addition, the analysis of the third group through the variance analysis showed significance at >0.05 for the general population and the patient group. Based on this, a multi-comparison analysis of the third group showed significantly less than 0.05 in patients who do not use an earthing mat compared to the public. First of all, there are no statistically significant differences between the three groups in subjective sleep quality, sleep latency, and sleep time, but an analysis of multiple comparison analysis with the general population group showed that the quality of sleep was worse compared to those that used the mat. In addition, sleep efficiency, sleep disorder, sleeping pills, and daytime dysfunction were found to be less than >0.05 in the three groups. Conclusions: These results suggest that if you ground your body to Earth during sleep, the secretion of cortisol will decrease night levels, sync more with the natural 24-hour circulation rhythm profile, and that when you sleep, sleep is better and pain and stress are associated with the study. While the preceding study cannot confirm that contact with the ground affects the quality of sleep, it suggests that it is relevant as shown in this paper.

Channel and Data Analysis System for Digital TV Broadcasting Using Modified Hilbert Transform (변형된 힐버트 변환을 이용한 디지털 TV 방송 채널 및 데이터 분석 시스템)

  • Suh, Young-Woo;Lee, Jae-Kwon;Mok, Ha-Kyun;Choi, Jin-Yong;Seo, Jong-Soo
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.438-449
    • /
    • 2009
  • To analyze reception environments of ATSC Digital TV, CIR (Channel Impulse Response) analysis systems are widely applied. The receiving performances of conventional CIR analysis systems are not as good as those of commercial state-of-the-art receivers. There are difficulties in measuring and analyzing reception problems caused by multi-path interferences. To solve these problems, commercial DTV chip sets embedded CIR analysis system is proposed. Generally, commercial chip sets provide baseband (In-phase) channel data and field or segment sync data. For more precise analysis of measured I channel data, it is necessary to extract Q (quadrature) channel data components as well. This paper presents the technical requirements of CIR analysis system for DTV. In order to satisfy such requirements and measure more accurate magnitude and phase of CIR, a method to derive the quadrature data from the measured in-phase channel data is proposed. The proposed channel analysis system is implemented with a commercial DTV chip set and expedites the data analysis for use on DTV field test vehicles. Computer simulation and laboratory test results are provided to demonstrate the performance of the proposed channel analysis system.

The Effects of Wearing Roller Shoes on Muscle Activity in The Lower Extremity During Walking (롤러신발과 일반신발의 착용 후 보행 시 하지근의 근전도 비교)

  • Chae, Woen-Sik;Lim, Young-Tae;Lee, Min-Hyung;Kim, Jung-Ja;Kim, Youn-Joung;Jang, Jae-Ik;Park, Woen-Kyoon;Jin, Jae-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to compare muscle activity in the lower extremity during walking wearing jogging and roller shoes. Twelve male middle school students (age: 15.0 yrs, height 173.7 cm, weight 587.7 N) who have no known musculoskeletal disorders were recruited as the subjects. Seven pairs of surface electrodes (QEMG8, Laxtha Korea, gain = 1,000, input impedance >$1012{\Omega}$, CMMR >100 dB) were attached to the right-hand side of the body to monitor the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), tibialis anterior (TA), and medial (GM) and lateral gastrocnemius (GL) while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and EMG recordings. EMG data were filtered using a 10 Hz to 350 Hz Butterworth band-passdigital filter and further normalized to the respective maximum voluntary isometric contraction EMG levels. For each trial being analyzed, five critical instants and four phases were identified from the recording. Averaged IEMG and peak IEMG were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). The VM, TA, BF, and GM activities during the initial double limb stance and the initial single limb stance reduced significantly when going from jogging shoe to roller shoe condition. The decrease in EMG levels in those muscles indicated that the subjects locked the ankle and knee joints in an awkward fashion to compensate for the imbalance. Muscle activity in the GM for the roller shoe condition was significantly greater than the corresponding value for the jogging shoe condition during the terminal double limb stance and the terminal single limb stance. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the GM activity for the roller shoe condition increased. It seems that there are differences in muscle activity between roller shoe and jogging shoe conditions. The differences in EMG pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine joint kinematics during walking with roller shoes.

A Study on the Development of Lightweight Seat Cushion Extension Module (경량형 시트 쿠션 익스텐션 모듈 개발에 관한 연구)

  • Jang, Hanseul;Choi, Seongkyu;Park, Sang-Chul;Lim, Heon-pil;Oh, Eu-Ddeum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.200-207
    • /
    • 2016
  • The automotive seat is an important component that moves in sync with the driver and is actively being developed with various new functions. The aim of this work is to develop a lightweight seat cushion extension module using a lightweight material. To this end, a structural strength analysis, vertical strength test, and durability test were conducted. In the structural analysis, the maximum value of deformation under vertical load was 4.98 mm at the front of the upper panel. The maximum stress was approximately 105 MPa, which occurred at the point of contact between the upper and lower panels of the module. The vertical strength test showed a maximum vertical deformation of 5.31 mm under a vertical load, which differed from the analysis results by approximately 6.45%. The structural safety of the product was verified by the fact that it showed no harmful deformation or damage during operation after the vertical strength test and a durability test for 20,000 cycles. Furthermore, the use of engineering plastics made it possible to reduce the weight by approximately 30% compared to existing products. The lack of damage after tests verified the passenger safety, strength, and rigidity of the product. The results are expected to be applied for improving environmental and fuel efficiency regulations and preventing accidents due to driver fatigue. The applications of this module could be expanded various types of vehicles, as well as other industries in which eco-friendly and lightweight materials are used.

8VSB Equalization Techniques for the Performance Improvement of Indoor Reception (실내 수신 성능 개선을 위한 8VSB의 등화 기법)

  • 김대진;박성우;이종주;전희영;이동두;박재홍
    • Journal of Broadcast Engineering
    • /
    • v.4 no.2
    • /
    • pp.103-118
    • /
    • 1999
  • This paper analyzes the performance of symbol timing recovery and equalizer in 8VSB digital terrestrial TV receiver under various multipath signals and proposes equalization techniques which improve indoor reception performance. Data segment sync is used for symbol timing recovery and timing offset is measured for echoes of various delays and amplitudes by using symbol timing detection filter whose pattern is +1. +1. -1. and -1. Measured timing offsets were below 10% for long echoes with more than 5 symbol delay and above 30% for short echoes with around 1 symbol delay. Indoor reception is always more challenging than outdoor reception due to lower signal strength. large and short multipaths. and moving interfering objects. So it is considered to use FSE (Fractionally Spaced Equalizer) which is very robust to timing offset and blind equalizer which can update equalizer tap coefficients even by information data. We compare the performance of conventional DFE (Decision Feedback Equalizer) and FSE-DFE using LMS algorithm and Stop and Go algorithm for the indoor reception. Experiments reveals FSE has excellent performance for large timing offset and Stop and Go algorithm shows good performance for Doppler shift. so we propose to use FSE-DFE structure with Stop and Go algorithm for the reliable indoor reception.

  • PDF