• Title/Summary/Keyword: Symmetric axis

Search Result 156, Processing Time 0.025 seconds

Immunohistochemical and Ultrastructural Characterization of the Choline Acetyltransferase-immunoreactive Nerve Cells in the Diagonal Band of Broca of the Rat Basal Forebrains (흰쥐의 전뇌 기저부 대각 Broca대에서 Choline Acetyltransferase 면역반응 신경세포에 대한 면역조직화학 및 미세구조)

  • Back, Seung-Keun;Chung, Young-Wha
    • Applied Microscopy
    • /
    • v.29 no.3
    • /
    • pp.383-403
    • /
    • 1999
  • This study was performed to investigate the immunohistochemical and ultrastructural characterization of the choline acetyltransferase (ChAT)-immunoreactive nerve cells in the diagonal band of Broca of the rat basal forebrains, utilizing techniques of immunohistochemical and immunocytochemical microscopy. The ChAT-immunoreactivities were shown within neuronal cell bodies and processes by the light micoscope. According to cell shape and ratio of long axis vs short axis of cell body, the ChAT-immunoreaclive nerve cells in both vertical and horizontal limbs of the diagonal band of Broca were classified into 6 types. at the light microscopic level; round, oval, elongated, fusiform, triangular and polygonal types. As a result of the electron microscopic observation, the ChAT-immunoreactivated products appeared on the outer nuclear envelope, membranes of rough endoplasmic reticula (rER), free ribosomes and polysomes. Each cell type was subdivided into subtype I and II according to the several criteria such as volume of cell body, nuclear size relative to the cytoplasm, kinds and distribution of cell organelles and numbers and sorts of synapses. The subtype I of immnunoreactive nerve cells had large cell body and a small nucleus showing shallow indentations of nuclear evelope. In this subtype I with abundant cytoplasm, rER were well differentiated. Their long cisternae were parallelly ditributed and lamellated. One or two lamellar bodies and nematosomes were observed. The subtype II cell had small cell body and a large nucleus with deep indentations of nuclear envelope. In this subtype II with small cytoplasm, the rER were irregularly distributed and the lamellar body and nematosome were not found. A few axosomatic synapses in the subtype I and II were shown to be symmetric or asymmetric. The ratios of the symmetric synapse to the asymmetric one were investigated to be 1 : 2 and 1 : 4 in the subtype I and II, respectively. The axodendritic ones were almost asymmetric. But, the fusiform and triangular immunoreactive nerve cells were shown only to be subtype I. According to observations in this study, it is considered that the ultrastructural characterization in the 2 subtypes of each cell type may reflect the differences of the metabolic activities and projecting distances to the target cells.

  • PDF

Face Detection Using A Selectively Attentional Hough Transform and Neural Network (선택적 주의집중 Hough 변환과 신경망을 이용한 얼굴 검출)

  • Choi, Il;Seo, Jung-Ik;Chien, Sung-Il
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.4
    • /
    • pp.93-101
    • /
    • 2004
  • A face boundary can be approximated by an ellipse with five-dimensional parameters. This property allows an ellipse detection algorithm to be adapted to detecting faces. However, the construction of a huge five-dimensional parameter space for a Hough transform is quite unpractical. Accordingly, we Propose a selectively attentional Hough transform method for detecting faces from a symmetric contour in an image. The idea is based on the use of a constant aspect ratio for a face, gradient information, and scan-line-based orientation decomposition, thereby allowing a 5-dimensional problem to be decomposed into a two-dimensional one to compute a center with a specific orientation and an one-dimensional one to estimate a short axis. In addition, a two-point selection constraint using geometric and gradient information is also employed to increase the speed and cope with a cluttered background. After detecting candidate face regions using the proposed Hough transform, a multi-layer perceptron verifier is adopted to reject false positives. The proposed method was found to be relatively fast and promising.

Wall Tie Member Force Curve for the Construction Tower Crane (건축용 타워크레인 마스트의 횡방향 지지요소인 월타이 부재력 특성곡선)

  • Ko, Kwang IL;Oh, W.H.;Lee, E.T.
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.6
    • /
    • pp.697-706
    • /
    • 2006
  • Tower crane's wall tie is generally used for extending of mast height according to rising of lifting height. In order to get wall tie member force this problem, this study concerning wall tie is based on load data described in manual book of 290HC model. This study made the equation of wall tie member force and computer programming for calculating wall tie member force and then get ${\theta}-P$ curves(angle-wall tie force). After considering the ${\theta}-P$ curves, optimum angle range ($48.4^{\circ}{\sim}77.2^{\circ}$) about wall ties (A), (C) members was obtained. Member force of wall tie (B) was changed from tension to compression or from compression to tension at $74^{\circ}$ in service and $54^{\circ}$ in out of service. When both horizontal force($H_A$) and torsional moment ($M_D$) were varied from (+) to (-), wall tie force(A, B, C) were changed almost symmetrically about ${\theta}$-axis. Because this study was based on wall tie analysis conditions, wall tie members in symmetric and ideal geometry shape used for analizing wall tie of tower crane, it is necessary to have more careful verification in order to apply generally the results of this study.

Seismic Traveltime Tomography in Inhomogeneous Tilted Transversely Isotropic Media (불균질 횡등방성 매질에서의 탄성파 주시토모그래피)

  • Jeong, Chang-Ho;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.229-240
    • /
    • 2007
  • In this study, seismic anisotropic tomography algorithm was developed for imaging the seismic velocity anisotropy of the subsurface. This algorithm includes several inversion schemes in order to make the inversion process stable and robust. First of all, the set of the inversion parameters is limited to one slowness, two ratios of slowness and one direction of the anisotropy symmetric axis. The ranges of the inversion parameters are localized by the pseudobeta transform to obtain the reasonable inversion results and the inversion constraints are controlled efficiently by ACB(Active Constraint Balancing) method. Especially, the inversion using the Fresnel volume is applied to the anisotropic tomography and it can make the anisotropic tomography more stable than ray tomography as it widens the propagation angle coverage. The algorithm of anisotropic tomography is verified through the numerical experiments. And, it is applied to the real field data measured at limestone region and the results are discussed with the drill log and geological survey data. The anisotropic tomography algorithm will be able to provide the useful tool to evaluate and understand the geological structure of the subsurface more reasonably with the anisotropic characteristics.

A Study on Dose Distribution around Fletcher-Suit Colpostat Containing Cs-137 Source by a Computer (컴퓨터 의한 Fletcher-Suit Colpostat 주변의 Cs-137의 선량분포에 관한 연구)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.2
    • /
    • pp.305-311
    • /
    • 1989
  • Fletcher-Suit colpostat has an internal structure to reduce dose to bladder and rectum. Some programs were developed to calculate dose at any point in water in three dimension around the colpostat containing Cs-137 tube, to find the shielding effect to dose by the internal structure, and to draw isodose curves and iso-shielding effect curves. Computer was an IBM compatible AT with EGA card and language was MS-Basic V6.0, Material, shape and geometry of the strucure, tube and colpostat were considered in algorithm for calculation of dose. Dose rates per unit mg. Ra. eq. in water calculated by a program were stored in auxiliary memory devices and retrieved in another programs. Isodose curves on medial side shrinked. Dose distribution was not symmetric about a transverse axis bisecting the colpostat. Reduction of dose was more excessive on top side than on bottom. Iso-shielding effect curve showed that the shielding effect was higher on top side than on bottom, and that there was shielding effect over almost all area of medial side. Such results were related to both shifted position of tube in the colpostat and asymmetric distribution of active source in the tube. Maximum of shielding effect was $49\%$ on top side and $44\%$ on bottom side. The direction of iso-shielding effect curve was generally radial from the center of active source. In treatment planning using Fletcher-Suit colpostat, the internal structure should be considered to find precise doses to bladder and rectum, etc.

  • PDF

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF