• Title/Summary/Keyword: Switching Time

Search Result 1,898, Processing Time 0.037 seconds

Separation Inverter Noise and Detection of DC Series Arc in PV System Based on Discrete Wavelet Transform and High Frequency Noise Component Analysis (DWT 및 고주파 노이즈 성분 분석을 이용한 PV 시스템 인버터 노이즈 구분 및 직렬 아크 검출)

  • Ahn, Jae-Beom;Jo, Hyun-Bin;Lee, Jin-Han;Cho, Chan-Gi;Lee, Ki-Duk;Lee, Jin;Lim, Seung-Beom;Ryo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.271-276
    • /
    • 2021
  • Arc fault detector based on multilevel DWT with analysis of high-frequency noise components over 100 kHz is proposed in this study to improve the performance in detecting serial arcs and distinguishing them from inverter noise in PV systems. PV inverters generally operate at a frequency range of 20-50 kHz for switching operation and maximum power tracking control, and the effect of these frequency components on the signal for arc detection leads to negative arc detection. High-speed ADC and multilevel DWT are used in this study to analyze frequency components above 100 kHz. Such high frequency components are less influenced by inverter noise and utilized to detect as well as separate DC series arc from inverter noise. Arc detectors identify the input current of PV inverters using a Rogowski coil. The sensed signal is filtered, amplified, and used in 800kSPS ADC and DWT analysis and arc occurrence determination in DSP. An arc detection simulation facility in UL1699B was constructed and AFD tests the proposed detector were conducted to verify the performance of arc detection and performance of distinction of the negative arc. The satisfactory performance of the arc detector meets the standard of arc detection and extinguishing time of UL1699B with an arc detection time of approximately 0.11 seconds.

Training and Management of Pets using Lego Mind Storms (레고 마인드스톰을 활용한 반려동물 훈련 및 관리에 관한 연구)

  • Jang, Donghwan;Kim, Sihyun;Yoon, Hosik;Kim, Minju;Lee, Sungjin;Moon, Sangho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.383-385
    • /
    • 2021
  • According to a paper on estimating and forecasting the size of the pet-related industry published in 2018, 26.9% of the nation's pet-owned households were in their 30s and one-person households, consisting only of couples, as of 2015. Regarding the social increase in single-person households and double-income couples, it is believed that the surge in neglect time and lack of training time that pets do not want is a problem. This paper conducted the development of hardware and software products for the training and management of companion animals using Lego Mind Storm. Lego mind Storm is equipped with a variety of sensors and can produce equipment to train or care pets with simple programming through easy assembly and visual scripting. It is also expected that switching to new equipment will be easy because it is well modularized. We hope that this study will help the training and management of pets when the expansion of the pet market becomes active through this study.

  • PDF

A Method of Determination of the Number of Tests for Reliability Growth Management (신뢰성 성장관리 시험의 시험 시료 수 결정 방안)

  • Yangwoo Seo;Daeung Choi;Chunsup Um;Yonggeun Kim;Jungtae Kim
    • Journal of The Korean Institute of Defense Technology
    • /
    • v.5 no.1
    • /
    • pp.1-6
    • /
    • 2023
  • The number of test samples was calculated by setting the reliability growth management test period considering the weapon system development period. The optimal reliability growth management test design condition was 80% reliability, 60% confidence level, and 6 months of test period. At this time, it was analyzed that 4 test samples were required if 0 failure occurred, and 9 test samples were required if 1 failure occurred. Using the method of determining the number of samples presented in this paper, it can be used as a basis for acquiring a budget for the number of samples for reliability growth management when switching from the exploratory development stage to the system development stage.

  • PDF

Development of Real-Time Vision Aided Navigation Using EO/IR Image Information of Tactical Unmanned Aerial System in GPS Denied Environment (GPS 취약 환경에서 전술급 무인항공기의 주/야간 영상정보를 기반으로 한 실시간 비행체 위치 보정 시스템 개발)

  • Choi, SeungKie;Cho, ShinJe;Kang, SeungMo;Lee, KilTae;Lee, WonKeun;Jeong, GilSun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.6
    • /
    • pp.401-410
    • /
    • 2020
  • In this study, a real-time Tactical UAS position compensation system based on image information developed to compensate for the weakness of location navigation information during GPS signal interference and jamming / spoofing attack is described. The Tactical UAS (KUS-FT) is capable of automatic flight by switching the mode from GPS/INS integrated navigation to DR/AHRS when GPS signal is lost. However, in the case of location navigation, errors accumulate over time due to dead reckoning (DR) using airspeed and azimuth which causes problems such as UAS positioning and data link antenna tracking. To minimize the accumulation of position error, based on the target data of specific region through image sensor, we developed a system that calculates the position using the UAS attitude, EO/IR (Electric Optic/Infra-Red) azimuth and elevation and numerical map data and corrects the calculated position in real-time. In addition, function and performance of the image information based real-time UAS position compensation system has been verified by ground test using GPS simulator and flight test in DR mode.

Performance Analysis of The CCITT X.25 Protocol (X. 25 Protocol의 성능 분석)

  • 최준균;은종관
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.11 no.1
    • /
    • pp.25-39
    • /
    • 1986
  • In this paper, we analyze the performance, particularly the flow control mechanism, of the CCITT X.25 protocol in a packet-switched network. In this analysis, we consider the link and packet layers separately, and investigate the performance in three measures; normalized channel throughput, mean transmission time, and transmission efficiency. Each of these measures is formulated in terms of given protocol parameters such as windos size, $T_1$ and $T_2$ values, message length, and so forth. We model the service procedure of the inpur traffic based on the flow control mechanism of the X.25 protocol, and investigate the mechanism of the sliding window flow control with the piggybacked acknowlodgment scheme using a discrete-time Markov chain model. With this model, we study the effect of variation of the protoccol parameters on the performance of the X.25 protocol. From the numerical results of this analysis one can select the optimal valuse of the protocol parameters for different channel environments. it has been found that to maintain the trasnmission capacity satisfactorily, the window size must be greater than or equal to 7 in a high-speed channel. The time-out value, $T_1$, must carefully be selected in a noisy channel. In a normal condition, it should be in the order of ls. The value of $T_2$ has some effect on the transmission efficiency, but is not critical.

  • PDF

Empirical Study of the PLSP (Priority Land and Signal Preemption for Emergency Vehicles (긴급차량의 우선차로 및 우선신호 도입효과 -청주시를 대상으로-)

  • Lee, Jun;Ham, Seung Hee;Lee, Sang Jo
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.650-657
    • /
    • 2020
  • Purpose: In this study, the effectiveness of pilot project of PLSP (Priority Lane and Signal Preference) system, which was operated in Cheongju City, was analyzed. Method: The priority signal was operated by a police officer switching to a blue signal when approaching a fire truck through CCTV, and the priority lane of emergency vehicles was displayed on the road to enable preferential traffic. VISSIM simulation analysis was performed for the 1.2km section (3.8km) of the pilot project section and vehicle data was analyzed for some of the test operation sections. Result: Simulation analysis shows that the moving speed of the emergency vehicle can be increased by 42 km/h with the introduction of PLSP, which can be increased by approximately twice the speed. Travel time was reduced by about 3 minutes, and considerable improvements of 69% compared to cities that are not operating was analyzed. The pilot operation of Cheongju City showed a time-shortening effect of about two minutes on average, with the average time reaching 4 minutes and 14 seconds in the first period and the average time reaching 5 minutes and 40 seconds in the second period. Conclusion: The system has been shown to be effective in minimizing time-to-site arrival of emergency vehicles.

A Study on Power Conversion System for Fuel Cell Controlled by Micro-Processor (마이크로프로세서에 의해 제어되는 연료전지용 전력변환장치에 관한 연구)

  • Kim, Ju-Yong;Jung, Sang-Hwa;Mun, Sang-Pil;Ryu, Jae-Yup;Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.10-24
    • /
    • 2007
  • In the dissertation, a power conversion system for fuel cell is composed of a PWM inverter with LC filter in order to convert fuel cell voltage to a single phase 220[V]. In addition, new insulated DC-DC converters are proposed in order that fuel cell voltage is boosted to 380[V]. In this paper, it requires smaller components than existing converters, which makes easy control. The proposed DC-DC converter controls output power by the adjustment of phase-shift width using switch $S_5\;and\;S_6$ in the secondary switch which provides 93-97[%] efficiency in the wide range of output voltage. Fuel cell simulator is implemented to show similar output characteristics to actual fuel cell. Appropriate dead time td enables soft switching to the range where the peak value of excitation current in a high frequency transformer is in accordance with current in the primary circuit. Moreover, appropriate setting to serial inductance La reduces communication loss arisen at light-load generator and serge voltage arisen at a secondary switch and serial diode. Finally, TMS320C31 board and EPLD using PWM switching technique to act a single phase full-bridge inverter which is planed to make alternating current suitable for household

Bioequivalence of Stapin ER Tablet to Splendil ER Tablet (Felodipine 5 mg) (스프렌딜 지속정(펠로디핀 5 mg)에 대한 스타핀 지속정의 생물학적동등성)

  • Cho, Hea-Young;Kang, Hyun-Ah;Lee, Suk;Baek, Seung-Hee;Park, Eun-Ja;Choi, Hoo-Kyun;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.4
    • /
    • pp.311-317
    • /
    • 2003
  • Felodipine is a calcium antagonist that lowers blood pressure by reducing peripheral resistance by meas of a direct, selective action on smooth muscle in arterial resistance vessels. Futhermore, it have been approved for the effective in angina pectoris and cardiac failure. The purpose of the present study was to evaluate the bioequivalence of two felodipine extended release (ER) tablets, Splendil (YuHan Corporation) and Stapin (Hana Pharmaceutial Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). The felodipine release from the two felodipine formulations in vitro was tested using KP VIII Apparatus II method at pH 6.5 buffer solution. Twenty six healthy male subjects, $22.73{\pm}1.78$ years in age and $66.66{\pm}7.28\;kg$ in body weight, were divided into two groups and a radomized $2{\times}2$ cross-over study was employed. After two tablets containing 5 mg as felodipine were orally administered, blood sample was taken at predetermined time intervals and the concentrations of felodipine in serum were determined using column-switching HPLC method with UV detector. The dissolution profiles of two formulations were similar at pH 6.5 buffer solution. Besides, the pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t\;and\;C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the Splendil were 2.53%, 1.32% and 18.32% for $AUC_t,\;C_{max}\;and\;T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance rage of log(0.86) to log(1.25) $(e.g.,\;log(0.86){\sim}log(1.20)\;and\;log(0.89){\sim}log(1.23)\;for\;AUC_t,\;C_{max},\;respectively)$. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Stapin ER tablet and Splendil ER tablet are bioequivalent.

A Study on Definition and Types of Migration Path of Multiple Generation Technology: Case of Customers' and Suppliers' Migration Paths in Semiconductor Technology (다세대 기술 이동경로(Migration path)의 정의 및 종류에 대한 연구: 반도체 기술의 고객 및 공급자 이동경로 사례)

  • Park, Changhyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.181-188
    • /
    • 2019
  • The migration path of a multiple-generation technology that occurs during a technological substitution by a new technology is important to understanding the phenomenon of technological substitution, and can contribute to understanding the process of technological innovation. This research defines the concept of migration path and develops a model of the types of migration paths by multiple dimensions (actor, generation, and time) in a multiple-generation technology. Based on a literature review and tracking of migration paths according to multiple dimensions, the definitions and types of migration paths were provided, and the accuracy of the model was verified based on a case study of the semiconductor industry. The migration paths of suppliers are modeled with three types (switching, leapfrogging, and new entrance paths), and the migration paths of customers are modeled with four types (switching, leapfrogging, new entrance, and diffusion paths) in a multiple-generation technology. This research will be useful for understanding the migration paths in the phenomenon of technological substitution, and can be applied to other industries in addition to the semiconductor industry, including various actors. In addition, suppliers and customers can understand technological substitution and can establish a technology strategy against their competitors.

Bioequivalence of Hana Loxoprofen Sodium Tablet to Dongwha Loxonin® Tablet (Loxoprofen Sodium 60 mg)

  • Kang, Hyun-Ah;Cho, Hea-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.2
    • /
    • pp.117-123
    • /
    • 2011
  • Loxoprofen sodium, a 2-phenylpropionate non-steroidal anti-inflammatory drug (NSAID), has marked analgesic and antipyretic activities and relatively weak gastrointestinal ulcerogenicity. The purpose of the present study was to evaluate the bioequivalence of two loxoprofen sodium tablets, Hana loxoprofen sodium tablet (Hana Pharm. Co., Ltd.) and Dongwha Loxonin$^{(R)}$ tablet (Dongwha Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The in vitro release of loxoprofen from the two loxoprofen sodium formulations was tested using KP IX Apparatus II method with various dissolution media. Twenty four healthy Korean male volunteers, $22.83{\pm}1.862$ years in age and $69.92{\pm}9.14$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ crossover study was employed. After a single tablet containing 60 mg as loxoprofen sodium was orally administered, blood samples were taken at predetermined time intervals and the concentrations of loxoprofen in serum were determined using a online column-switching HPLC method with UV/Vis detection. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC^t$, $C_{max}$ and $T_{max}$ were calculated, and computer programs (Equiv Test and K-BE Test 2002) were utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and un-transformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, Dongwha Loxonin$^{(R)}$ tablet, were 2.03, 2.99 and -9.49% for $AUC_t$, $C_{max}$, and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log0.8 to log1.25 (e.g., log0.9831~log1.0535 and log0.9455~log1.1386 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Hana loxoprofen sodium tablet was bioequivalent to Dongwha Loxonin$^{(R)}$ tablet.