• Title/Summary/Keyword: Switchgear

Search Result 358, Processing Time 0.027 seconds

Discharge Phenomena of Glass Tube Vacuum under AC Applied Voltage (AC 전압하에서 유리진공관의 방전현상)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.371-372
    • /
    • 2008
  • In this paper, we experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and $SF_6$. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

An Information Transmission Method of the DC Switchgear for Light Railway Vehicle (경량전철용 직류배전반의 정보 전송방식)

  • Lee, H.D.;Kim, S.N.;Ryu, S.P.;Lee, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.143-145
    • /
    • 2005
  • This paper describes the transmission method of an information using communication networks between RTU(Remote Terminal Unit) and PCU(Protection and Control System) of the DC switchgear for Light Railway Vehicle. Also the test result carried out in the laboratory was represented. In this test, transmission signal waveform, polling time, response time and request/response frame between RTU and PCU were measured. The field test including the measurements of analog signal and status of the digital logic operation of PCU was conducted in Gyeongsan Test Track.

  • PDF

Application of UHF Partial discharge sensing technology in AC withstand voltage test of gas-insulated switchgear (345 kV GIS AC 내전압 시험의 UHF 부분방전 검출기술 적용)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yeol;Jung, Kil-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1843-1845
    • /
    • 2000
  • GIS(Gas insulated switchgear)내부에서 발생한 부분방전 신호를 검출 할 수 있는 UHF(Ultra-high frequency) 부분방전 검출 센서를 345 kV GIS의 AC 내전압 시험에 적용하였다. 부분방전 센서를 적용한 상태에서 각 상별로, bus별로 나누어 계통 최고전압의 1.0 p.u, 1.5 p.u, 1.73 p.u 전압을 단계적으로 인가하였으며 간헐적으로 부분방전 신호가 검출됨을 확인하였다. 간헐적인 부분방전 신호는 GIS 내부에 있던 이물질에서 약한 방전이 시작되고 인가전압을 높임에 따라 방전의 강도가 증가하다 소멸되었다. 방전을 일으킨 이물질이 모두 증발되었거나 위치 변화에 의해 방전이 소멸된 것으로 판단된다.

  • PDF

A Study on the Design of the rated insulation voltage of 690V for the low-voltage switchgear and controlgear (저압기기 정격절연전압 690V 개발시 고려사항에 대한 연구)

  • Kim, Myoung-Seok;Kim, Jong-Yeok;Park, Sang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.961-963
    • /
    • 2000
  • Most of the application standard of the low-voltage devices have applied one the IEC standard another the UL standard. European union applied the IEC60947-1 standard has not exceed 1000V a.c. or 1500V d.c.. Therefore. it is necessary to the low-voltage device has expended for rated operational voltage with our products. The export of European market shall be made for the CE-Marking in accordance with IEC60947-1 ( Low-voltage switchgear and controlgear). We shall be considered for the requirement with the IEC standard. In this time to study for power supply system at EU ( European union. At that time for design and development in order to the construction and test method among the study for the rated insulation voltage at less then 690V.

  • PDF

Studies of Internal UHF Partial Discharge Sensors for the Gas Insulated Switchgear (GIS 부분방전 검출용 내장형 UHF 센서의 특성조사)

  • Goo, Sun-Geun;Park, Ki-Jun;Yoon, Jin-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1840-1842
    • /
    • 2000
  • GIS(Gas Insulated Switchgear) 내부에서 부분방전 신호를 검출 할 수 있는 UHF(Ultra High Frequency) 센서를 제작하고 그 특성을 조사하였다. UHF 센서는 GIS 내부에서 전기적, 기계적으로 안정된 형태로 제작되었으며, 영국의 NGC(National Grid Company)에서 제시한 규격을 충분히 만족함을 확인하였다. 부분방전 신호가 발생되는 모형 GIS 내에 UHF 센서를 장착하여 실제 부분방전 산호가 잘 측정됨을 확인하였다.

  • PDF

Analysis of Partial Discharge Signals Using Statistical and Pattern Recognition Technique (통계처리와 패턴 인식 기법에 의한 부분방전 해석)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.12
    • /
    • pp.1231-1234
    • /
    • 2006
  • In this study, we detected electromagnetic waves generated in an enclosed switchgear and applied various statistical methods for detecting signals. We calculated the various statistical factors via the appropriate statistical methods. Further, we used these statistics to recognize the characteristics for each pattern by identifying the partial discharge in each case for normal, proceeding and abnormal states. The characteristics of electromagnetic wave patterns occurred in various states at electric power facilities and were used as an output variable for more efficient diagnosis. In this paper, we confirmed that the pattern of partial discharge signal can be used as one of the factors used to analyze the insulation state and to consider while estimating diagnosis of insulation states by recognizing the signal pattern to intelligence. We will utilize the proposed diagnosis method to determine insulation degradation states.

A Study on the Algorithm for Detection of Partial Discharge in G15 Using Wavelet Transform (웨이브렛 변환을 이용한 GIS의 부분방전 검출 알고리즘에 관한 연구)

  • 강진수;김철환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.1
    • /
    • pp.25-34
    • /
    • 2003
  • Gas insulated switchgear(GIS) is an important equipment in a substation. It is highly desirable to measure a partial discharge(PD) in GIS which is a symptom before insulation breakdown occurs. The issue is that the PD signal is weak and sensitive to external noise. In this paper, the algorithm for detection of PD in GIS using wavelet transform is proposed. The wavelet transform provides a direct quantitative measure of spectral content, "dynamic spectrum", in the time-frequency domain. The recommended mother wavelet is 'Daubechies' wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, can be used most properly in disturbance phenomena which occurs rapidly for a short time. Through the procedure of wavelet transform, noise extraction and reconstruction, the signal is Analyzed to determine the magnitude of PD in GIS. In experimental results, we can know that partial discharge is exactly detected in combination of Dl and D2 using wavelet transform.transform.

A study on of drive mechanism for 245kV 40kA high-voltage Gas Insulated Switchgear(GIS) using SPMSM (SPMSM을 이용한 245kV 40kA GIS 조작기 개발에 관한 연구)

  • Jeong, Kyun-Ha;Oh, Young-Jin;Yeo, Chang-Ho;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.114-116
    • /
    • 2007
  • Mechanical spring and hydraulic pressure operated mechanisms are applied in most of today's High Voltage Gas Insulated Switchgear(GIS)s. This paper proposes a new type of operation mechanism for GIS circuit breakers rated at 245kV and 40kA. The Motor-Direct-Drive-Mechanism (MDDM) has many advantages compared to conventional operating mechanisms. It has a very simple structure with only one moving part, low mechanical stress and audible noise. It also allows monitoring, operation speed control and self-diagnosis functions.

  • PDF

Thermal Analysis using CFD of Cubicle type Gas Insulated Switchgear (CFD를 이용한 C-GIS의 열해석)

  • Ahn, Heui-Sub;Hong, Doo-Young;Lee, Han-Shin;Kim, Young-Geun;Oh, Il-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.882-884
    • /
    • 2003
  • In this paper, thermal analysis of Cubicle type Gas Insulated Switchgear(C-GIS) was investigated through experiments and numerical analysis. To predict 3-dimensional temperature and velocity distribution, the commercial package was used. Although some assumptions and simplifications were introduced to simulate the model, results from the computational model were in good agreement with actual temperature rise measurements obtained from experiments.

  • PDF

Development of Ubiquitous based Digital Switchgear Prototype for Home Automation (주택 자동화를 위한 유비쿼터스 기반의 디지털 분전반 프로토타입 개발)

  • Ko, Yun-Seok;Yun, Tae-Min;Yun, Seok-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.555-556
    • /
    • 2007
  • This paper proposes a new concept's IDSFHA(Intelligent Digital Switchgear For Home Automation) which can obtain the safety, the reliability and the easy to correspond to the request of the general electric customer or electric power company under the ubiquitous-based home automation environments The IDSFHA is designed by analyzing their requirement functions, a 32-bit micro processor is adopted as main controller to support efficiently the designed functions. The single phase power IC(ADE7753) is utilized to collect the electric power information, and makes it possible to communicate as internet among the IDSFHA and their using the ethernet convertor. In the proposed IDSFHA, the several functions are implemented such as the earth leakage level display and waveform transmitting, the electric power using fee display, voltage management, load management and load control function. Finally, the prototype of the IDSFHA is made experimently based on the designed results.

  • PDF