• 제목/요약/키워드: Switches

검색결과 1,790건 처리시간 0.031초

능동형 공진 스너버 (Active Resonant Snubber for Ideal Switched PWM Converter)

  • 문건우;이정훈;정영석;윤명중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.412-414
    • /
    • 1994
  • A new active resonant snubber (ARS) circuit providing the ideal switching conditions for PWM converter is presented. By using the proposed ARS circuit to PWM converters, the power switches can be operated to give zero-current and zero-voltage at both the instant of switch off and switch on, without increasing voltage/current stresses of the switches. Furthermore, the PWM converters employed ARS circuit has the advantage that it can operate at constant frequency, giving better definded EMI and filter ripple, and it is also suited for high-power application regardless of the semiconductor devices (such as MOSFETs or IGBTs) used as a power switches.

  • PDF

SCR의 영전류 스위칭에 의한 HID 램프용 조도제어형 자기식 안정기 개발 (Development of Dimmable Magnetic Ballast for HID-Lamps by Zero Current Switching on SCRs)

  • 이현진;유재웅;박종연
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.9-16
    • /
    • 2010
  • In this paper, we have proposed a new dimmable magnetic ballast for HID(High Intensity Discharge) lamps consisted of AC switches to variate inductance value by using Silicon Controlled Rectifiers and the isolated zero current detector on inductor. Conventional dimming ballast has used relays or Solid State Relays in AC switches. However, a relay is difficult to zero current switching, because it has long operating time(10[ms]), and price competitiveness of SSR is very low. The proposed AC switches are suitable to switch at zero inductor current and it is accurately detected by using a opto-coupler. SCR is cheaper than SSR, and it is suitable to switch at zero inductor current because SCR is automatically turned off under holding current at no gate signal. Operating principles, simulation results and experimental results of the proposed ballast are described.

Hybrid Cascaded MLI topology using Ternary Voltage Progression Technique with Multicarrier Strategy

  • Venugopal, Jamuna;Subarnan, Gayathri Monicka
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1610-1620
    • /
    • 2015
  • A major problem in conventional multilevel inverter is that an increase in power semiconductor switches causes an increase in cost and switching losses of the inverter. The multicarrier strategy adopted for the multilevel inverters has become more popular due to reduced cost, lower harmonic distortion, and higher voltage capability than the conventional switching strategy applied to inverters. Various topologies and modulation strategies have been reported for utility and drive applications. Level shifted based pulse width modulation techniques are proposed to investigate the performance of the multilevel inverter. The proposed work focuses on reducing the utilized switches so that the cost and the switching losses of the inverter do not go up and the consistent efficiency could be achieved. This paper presents the detailed analysis of these topologies. The analysis is based on the number of switches, DC sources, output level, maximum voltage, and the efficiency. As an illustration, single phase cascaded multilevel inverter topologies are simulated using MATLAB/SIMULINK and the experimental results demonstrate the viability of these inverters.

배전자동화 시스템에서 전력설비 부하균등화를 고려한 피더간 연계점 최적위치선정 (A Method for Optimal Location of Feeder Tie Switches for Improving Equal Load of Electric Power Equipment in Distribution Automation System)

  • 임일형;임성일;최면송;이승재;신창훈;하복남
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.821-828
    • /
    • 2007
  • This paper proposes a new algorithm to find optimal location of open switches connecting feeders in distribuion system. In order to enhance power system reliability by minimizing outage area in case of fault, the load balance among the facilities such as transformers and feeders is considered to optimize. The combination of optimal position of normal open switches can be found by moving tie along the direct path connecting two feeders related to the open switch while the whole optimization problem is separated into many small problems. The proposed algorithm is shown by case study results that, it is simple and takes short calculation time to apply to the DAS (Distribution Automation System) in KEPCO (Korea Electric Power Cooperation).

버스트 트래픽 환경에서의 이중 평면 패킷 스위치의 성능 분석 (Performance Analysis of Dual-Plane Nonblocking Switches under Burst Traffic)

  • 이현태;손장우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 춘계종합학술대회
    • /
    • pp.142-145
    • /
    • 1999
  • 본 논문에서는 이중 평면 패킷 스위치 구조를 가지는 이중 입력 /이중 스위칭 평면 구조(DQDP) 평면 선택 능력을 가진 DQDP(DQDP-PS) 구조, 출력 그룹 큐잉 능력을 가진 DQDP(DQDP-OGQ) 구조에 대한 지연 성능 분석을 연구하였다. 성능 분석을 통하여 랜덤 트래픽하에서는 거의 동일한 성능을 보이지만 버스트 트래픽 환경에서는 DQDP-PS와 DQDP-OGO 스위치만이 이상적인 출력 버퍼 패킷 스위치의 성능에 가까운 지연 특성을 얻을 수 있었다.

  • PDF

Three-Switch Active-Clamp Forward Converter with Low Voltage Stress

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.505-507
    • /
    • 2008
  • A conventional active-clamp forward (ACF) converter is a favorable candidate in low-to-medium power applications. However, the switches suffer from high voltage stress, i.e., sum of the input voltage and the reset capacitor voltage. Therefore, it is not suitable for high input voltage applications such as a front-end converter of which the input voltage is about 400-$V_{dc}$. To solve this problem, three-switch ACF (TS-ACF) converter, which employs two main switches and one auxiliary switch with low voltage stress, is proposed. Utilizing low-voltage rated switches, the proposed converter is promising for high input voltage applications with high efficiency and low cost.

  • PDF

Mitigation of Voltage Sag and Swell Using Direct Converters with Minimum Switch Count

  • Abuthahir, Abdul Rahman Syed;Periasamy, Somasundaram;Arumugam, Janakiraman Panapakkam
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1314-1321
    • /
    • 2014
  • A new simplified topology for a dynamic voltage restorer (DVR) based on direct converter with a reduced number of switches is presented. The direct converter is fabricated using only three bi-directional controlled switches. The direct converter is connected between the grid and center-tapped series transformer. The center-tapped series transformer is used to inject the compensating voltage synthesized by the direct converter. The DVR can properly compensate for long-duration, balanced, and unbalanced voltage sag and swell by taking power from the grid. The switches are driven by ordinary pulse width modulation signals. Simulation and hardware results validate the idea that the proposed topology can mitigate sag of 50% and swell of unlimited quantity.

MEMS형 RF Switch 구조물 제작 (Fabrication of MEMS Type RF Switch Structure)

  • 구찬규;김홍락;김영덕;정우철;김동수;남효덕
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.809-812
    • /
    • 2002
  • This paper presents the structures for a CPW shunt RF switch using MEMS(Micro Electro Mechanical System). Recent development in MEMS technology has made the design and fabrication of micro-mechanical switches as new switching elements. The micro-mechanical switches have low insertion loss, negligible power consumption, and good isolation compared to semiconductor switches. The fabricated structure shows an insertion loss of 2dB at 20GHz When a bias voltages of 12V is apply.

  • PDF

Synchronous Carrier-based Pulse Width Modulation Switching Method for Vienna Rectifier

  • Park, Jin-Hyuk;Yang, SongHee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.604-614
    • /
    • 2018
  • This paper proposes a synchronous switching technique for a Vienna rectifier that uses carrier-based pulse width modulation (CB-PWM). A three-phase Vienna rectifier, similar to a three-level T-type converter with three back-to-back switches, is used as a PWM rectifier. Conventional CB-PWM requires six independent gate signals to operate back-to-back switches. When internal switches are operated synchronously, only three independent gate signals are required, which simplifies the construction of gate driver circuits. However, with this method, total harmonic distortion of the input current is higher than that with conventional CB-PWM switching. A reactive current injection technique is proposed to improve current distortion. The performance of the proposed synchronous switching method and the effectiveness of the reactive current injection technique are verified using simulations and experiments performed with a set of Vienna rectifiers rated at 5 kW.

출력 스위치의 열화를 고려한 주파수 가변 구동 방식의 전자식 안정기 설계 (Design of Electronic Ballasts applied with Variable Frequency Driving Technique with regard for Thermal Degradation of Output Switches)

  • 오성근;최명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.157-161
    • /
    • 2000
  • The electronic ballasts for low pressure discharge lamps are produced and commercialized. However, the electronic ballasts for high pressure lamps are now in progress because of poor reliability and high cost. The major case of troubles with electronic ballasts are thermal destruction of semiconductor output switches due to non ideal i-v characteristics of switch. The loss converts to heat and rises the temperature of switch and it increases proportionally to switching frequency and value of current and voltage. This study shows the variable frequency ballasts which can suppress the heating of switches efficiently. It is used for the limitation the switch current and the rising temperature of switch by impedance variation of lamp inductor. As a result, initial warm-up time of the proposed ballasts was faster than that of magnetic ballasts about 90 msec. Power factor of tested ballasts follow as ; input and output average of magnetic ballasts are 93 [%] and 86 [%], respectively, And proposed ballasts are 97 [%] and 99 [%], respectively.

  • PDF