• Title/Summary/Keyword: Swing out

Search Result 146, Processing Time 0.028 seconds

Kinematic Analysis of Swing of Golfer on Professional Golf Tour (투어프로골퍼 스윙의 운동학적 분석)

  • Lim, Jung;Na, Sung-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.3
    • /
    • pp.43-80
    • /
    • 2008
  • The purpose of this research is to analysis the swing of driver used by professional golfers during on-season. In order to collect on-season driver swings of research objects, which are three KPGA(Korean Professional Golfer Association) professional golfers, measurements were carried out right after the last game of a season. The analysis range was set to down-swing point while analysis was conducted to after-impact, release point. As a result, systematic process between leading segments of the previous precise kinematic analysis research seems to turn up the same. However, there were different results compared to the preceding research. All three testers expressed adduction of left hand which could not be described with forming cocking angle, in consequence, adduction of left hand does not have a big effect on formation of cocking. Moreover, chest movement right before the impact; which was emphasized in previous research, the direction was not opposite but the same with the ball.

Clinical Study with Impedance Audiometry -Euatachian tube function and impedance audiometry- (Impedance audiometry의 임상적 연구 - III. impedance audiometry에 의한 구씨관 기능검사 -)

  • 민양기;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1976.06a
    • /
    • pp.85.2-85
    • /
    • 1976
  • Harford has pointed out that the application of impedance audiometry in the Eustachian tube function is of special value. As you know, with excessive negative pressure in the middle ear cavity with intact eardrum tympanograms reveal indirect evidence of Eustachian tube insufficiency. With normal Eustachian tube function eardrum should be pushed laterally by Valsalva maneuver, resulting in a temporary decrease in the compliance of the system, indicated by a swing of the balance meter needle. Therefore the authors measured the swing of the balance meter needle by the Valsalva maneuver in persons with intact eardrums, intact middle ear cavities, and intact Eustachian tube function. The results are as follows; The swing of the eardrum by Valsalva maneuver is 1.0 to 4.0 (mean $1.6{\pm}0.06$) and we conclude that the persons under 1.0 of the swing is suggestive of some disfunctions of the Eustachian tube.

  • PDF

Kinematic Analysis on Giant Swing Backward to Handstand on Parallel Bars (평행봉 뒤 휘돌리기 동작의 운동학적 분석)

  • Ahn, Wan-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.2
    • /
    • pp.27-40
    • /
    • 2004
  • The objective of this study is to identify the kinematic variables of giant swing backward to handstand as well as individual variations of each athlete performing this skill, which in turn will provide the basis for developing suitable training methods and for improving athlete's performance in actual games. For this end, 3 male athletes, members of the national team, who are in ${\Box}{\Box}H{\Box}{\Box}$ University, have been randomly chosen and their giant swing backward to handstand performance was recorded using two digital cameras and analyzed in 3 dimensional graphics. This study came to the following conclusion. 1. Proper time allocation for giant swing backward to handstand are: Phase 1 should provide enough time to attain energy for swing track of a grand round movement. The phase 3 is to throw the body up high in the air and stay in the air as long as possible to smoothen up the transition to the next stage and the phase 4 should be kept short with the moment arm coefficient of the body reduced. 2. As for appropriate changes of locations of body center, the phase 1 should be comprised of horizontal, perpendicular, compositional to make up a big rotational radius. Up to the Phase 3 the changes of displacements of vertical locations should be a good scale and athlete's body should go up high quickly to increase the perpendicular climbing power 3. When it comes to the speed changes of body center, the vertical and horizontal speed should be spurred by the reaction of the body in Phase 2 and Phase 3. In the Phase 4, fast vertical speed throws the body center up high to ensure enough time for in-the-air movement. 4. The changes of angles of body center are: in Phase 2, shoulder joint is stretching and coxa should be curved up to utilize the body reaction. In the Phase 4, shoulder joint and coxa should be stretched out to get the body center as high as possible in the air for stable landing. 5. The speeds of changes in joints angles are: in the Phase 2 should have the speed of angles of shoulder joints increase to get the body up in the air as quickly as possible. The Phase 3 should have the speed of angles in shoulder joint slow down, while putting the angles of a knee joint up to speed as quickly as possible to ensure enough time for in-the-air movement.

Protection Measure of Transmission Jumper Line by Gap Winds (협곡풍에 의한 송전선로점퍼선 횡진고장 방지대책)

  • Koh, Bong-Eon;Pyo, Gwang-Chan;Park, Jae-Hyung;Kang, Bum-Young;Jung, Hyun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1071-1077
    • /
    • 2009
  • Because several winds cause the a fault of transmission supply, KEPCO trys to protect the the trouble and supply the power stably. Kepco find out the weak mountains by winds and strengthen the power equipment annually. Power quality is the competition power in the international world and satisfy the customer using th power Therefore this paper deals with the fault relation between winds and transmission line.

A study on modeling and construction of Field Robot (Field Robot의 모델링과 구축에 관한 연구)

  • 임태형;양순용;이병룡;안경관;김승수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.481-486
    • /
    • 2002
  • Automation of Field Robot has many advantages for efficiency and convenience. In this paper, mathematical equation of field robot is established and automation system is constructed. Hydraulic and Dynamic equation of field robot are constructed in this paper. Inputs of system are angle data from each link (boom, arm, bucket, swing) and pressure data from in, out port of each cylinder. Outputs of system are voltage into electo-proportional valve.

  • PDF

Experimental modeling and Robust Control of an Industrial Overhead Crane

  • Park, B.S.;T.G. Song;Lee, J.Y.;D.H. Hong;J.S. Yoon;E.S. Kang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.45.2-45
    • /
    • 2001
  • In case that the perfect model following conditions are not satisfied in the system, a perfect model-following controller is difficult to apply to the system. To deal with this problem, in this paper, a robust imperfect stable model-following controller is designed by combining time delay controller and sliding mode controller based on the concept of two degrees of freedom(2-DOF) controller design method. The experimental dynamic modeling of the commercial overhead crane with capacity of two tons is carried out. To remove the noise of the measuring signals from the swing angle measurement device and estimate the state of the swing angles of the transported object at each time instant, realtime tracker is designed using Kalman filter. The performance of the designed robust controller is tested through the commercial overhead. The experimental results show that the designed controller is robust and applicable to real systems.

  • PDF

Observation of Gait Analysis of the Stroke Patient (뇌졸중환자의 보행 관찰분석)

  • Bae, Sung-soo;Kim, Sik-hyun;Kim, Sang-soo
    • PNF and Movement
    • /
    • v.6 no.1
    • /
    • pp.21-25
    • /
    • 2008
  • Purpose : The purpose of this study was conducted to find out observation at gait analysis of the stroke patient with proprioceptive neuromuscular facilitation(PNF) concept. Methods : This is a literature study with books, seminar note and international PNF course book. Results : Stroke patient gait was poor initial contact by weakness of tibialis anterior or weakness of contralateral plantar flexor, poor loading response by loss of deep sensation, poor mid stance by loss of deep sensation, weakness of tibialis anterior and weakness of plantar flexors eccentric control, poor terminal stance, pre-swing, initial swing by loss of deep sensation and stiffness fo deep toe flexors. Conclusion : Stroke patient gait determine on loss of mobility, pain, fear, trunk muscle weakness, loss of coordination, loss of deep sensation, neglect and apraxia. Therefore observational gait analysis of the stroke patient focus on gait cycle and take out hypotheses from the gait cycle. These hypotheses have to define accept or not by parameters. Treatment plan made with the hypotheses.

  • PDF

CLINICAL STUDY ON THE POSITIONAL CHANCE OF THE MANDIBLE AFTER TREATMENT OF CLASS III MALOCCLUSION(Permanent Dentition) (III급 부정교합 치료후의 하악골의 위치변화에 관한 임상적 고찰(영구치열에서))

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.24 no.1 s.44
    • /
    • pp.63-86
    • /
    • 1994
  • The purpose of this study was to find out some relationship between the positional change of mandible during treatment and the prognosis after treatment of ClassIII malocclusion. The patients selected for this study were sucessfully treated two patients, and three patients who wert also sucessful in active treatment but showed relapse during observation. Serial Cephalograms, photos, models, treatment record of these patients were analysed in each term of treatment and observation period. The results might be summarized as follows: The patient with swing back type in which mandible rotated posteroinferiorly during active treatment showed good dental md skeletal relationship during observation. Among the patients with Y-axis type, one who had harmonious growth between maxilla and mandible showed stable dental relationship during observation, the other who had not showed relapse. The swing back type was not changed during and after treatment but the patients who had Y-axis type were unchanged in some patients, and changed into forward type in the others. During active treatment, was lower facial height(ANS-Me) increased in all 5 patients, and in observation period the patients showing increase in lower facial height had stable occlusion but the others having decrease showed unstable dental relationship.

  • PDF

Quantitative Difference in the Extinguishing Concentration of Inert Gases with Fire Suppression Criteria in a Cup Burner Test (컵버너시험에서 소화기준에 따른 불활성기체의 소화농도에 대한 정량적 차이)

  • Cho, Jae-Ho;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.34-42
    • /
    • 2014
  • The concentrations of inert gases ($N_2$, Ar, $CO_2$ and He) required to induce the flame instabilities such as swing, rotation, lifted and blow-out were measured in a cup burner nonpremixed flames for $CH_4$ and $C_3H_8$ fuels. Quantitative differences in the extinguishing concentration with fire suppression criteria (i.e. blow-out or onset of flame instability) were also examined. It was found that the difference in extinguishing concentration was increased with the appearance of lifted flame and the low extinguishing performance of inert gaseous. The maximum difference in extinguishing concentration with the suppression criteria was approximately 35% at the highest fuel velocity condition (1.3 cm/s) for the $C_3H_8$-air nonpremixed flame. It can be also expected that the extinguishing concentration by the criteria based on the onset of flame instability will provide the useful information from the viewpoint of the accurate and economical design concentration.

Double-Gate MOSFET Filled with Dielectric to Reduce Sub-threshold Leakage Current

  • Hur, Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.283-284
    • /
    • 2012
  • In this work, a special technique called dielectric filling was carried out in order to reduce sub-threshold leakage current inside double-gated n-channel MOSFET. This calibration was done by using SILVACO Atlas(TCAD), and the result showed quite a good performance compared to the conventional double-gate MOSFET.

  • PDF