• 제목/요약/키워드: Sweep gas

검색결과 34건 처리시간 0.042초

마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정 (Temperature measurement of the spray flame using micro scale absorption bands and line strength)

  • 최경민
    • 한국분무공학회지
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

공급가스 및 스윕가스 유량에 따른 Ba0.5Sr0.5Co0.8Fe0.2O3-δ 분리막의 산소투과특성 (Effect of Flow Rates of Feed and Sweep Gas on Oxygen Permeation Properties of Ba0.5Sr0.5Co0.8Fe0.2O3-δ Membrane)

  • 박세형;손종석;이홍주;박정훈
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.407-411
    • /
    • 2015
  • 고상반응법으로 제조된 $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ 조성의 페롭스카이트 산화물 상용분말을 압축 성형 후 $1100^{\circ}C$에서 2시간 동안 소결한 후, 1.0 mm의 두께를 가지는 평판형 분리막을 제조하였다. $Ba_{0.5}Sr_{0.5}Co_{0.8}Fe_{0.2}O_{3-{\delta}}$ 분리막의 산소투과량은 온도와 산소분압이 증가함에 따라 증가하였고, 산소투과의 활성화에너지는 산소분압이 증가할수록 높은 값을 나타내었다. $950^{\circ}C$에서 공급가스와 스윕가스의 유량 변화에 따른 투과 특성 분석 결과, 유량이 증가할수록 높은 산소투과량을 보였으며, 공급가스보다 스윕가스의 유량에 따라 크게 변함을 확인하였다.

투과증발공정의 기초 이론

  • 염충균
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 심포지움시리즈 Jan-96 투과증발막과 응용
    • /
    • pp.1-23
    • /
    • 1996
  • 투과증발(Pervaporation)이란 어원적으로 "permeation"과 "evaporation"의 합성어인데 액체혼합물이 치밀한 비다공질막을 통해 이동하는 동안 증기화되면서 분리되는 막분리 공정이다. 이 공정에서 막 한쪽면은 액체공급액과 접하고 있고 다른 한쪽면은 낮은 투과물의 증기압과 접하고 있는데 낮은 증기압은 진공(vacuum pervaporation)을 가하거나 혹은 불활성의 담체가스(sweep gas pervaporation)를 흐르게 하므로써 얻을 수 있다. 이때 막 내부에 트과증발막공정의 추진력인 화학 포텐셜(chemical potential) 구배가 발생하여 막을 통한 물질투과가 이루어지는데 각 투과성분의 투과속도는 투과성분과 막재료간의 물리화학적 인력에 의해 결정된다.의 물리화학적 인력에 의해 결정된다.

  • PDF

Decrease in hydrogen crossover through membrane of polymer electrolyte membrane fuel cells at the initial stages of an acceleration stress test

  • Hwang, Byung Chan;Oh, So Hyeong;Lee, Moo Seok;Lee, Dong Hoon;Park, Kwon Pil
    • Korean Journal of Chemical Engineering
    • /
    • 제35권11호
    • /
    • pp.2290-2295
    • /
    • 2018
  • An acceleration stress test (AST) was performed to evaluate the durability of a polymer membrane in a polymer electrolyte membrane fuel cell (PEMFC) for 500 hours. Previous studies have shown that hydrogen crossover measured by linear sweep voltammetry (LSV) increases when the polymer membrane deteriorates in the AST process. On the other hand, hydrogen crossover of the membrane often decreases in the early stages of the AST test. To investigate the cause of this phenomenon, we analyzed the MEA operated for 50 hours using the AST method (OCV, RH 30% and $90^{\circ}C$). Cyclic voltammetry and transmission electron showed that the electrochemical surface area (ECSA) decreased due to the growth of electrode catalyst particles and that the hydrogen crossover current density measured by LSV could be reduced. Fourier transform infrared spectroscopy and thermogravimetric/differential thermal analysis showed that -S-O-S- crosslinking occurred in the polymer after the 50 hour AST. Gas chromatography showed that the hydrogen permeability was decreased by -S-O-S- crosslinking. The reduction of the hydrogen crossover current density measured by LSV in the early stages of AST could be caused by both reduction of the electrochemical surface area of the electrode catalyst and -S-O-S- crosslinking.

분리막 반응기를 이용한 천연가스 개질반응의 성능에 관한 비교 분석 (Comparative studies for the performance of a natural gas steam reforming in a membrane reactor)

  • 이보름;임한권
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.95-101
    • /
    • 2016
  • 본 연구에서는 다양한 수소 생산 방법 중 하나인 천연가스 수증기 개질반응(natural gas steam reforming reaction)에 대해 일반적인 충전층반응기와 반응기와 수소분리기가 결합된 새로운 형태의 분리막 반응기에서의 성능에 대한 비교분석을 수행하였다. Xu 와 Froment에 의해 기존에 발표된 실험결과를 바탕으로 상업용 화학공정모사기인 Aspen $HYSYS^{(R)}$ 모델이 개발되었으며, 반응온도, $H_2$ 투과량, Ar 유량 등이 분리막 반응기에서의 반응물의 전환율 및 $H_2$ 수율 향상도에 미치는 영향에 대해 분석한 결과 분리막 반응기에서 보다 많은 양의 수소수율 및 메탄전환율이 확인되었다. 더 나아가, 전체 시스템에서 필요로 하는 열량을 공급하기 위해 요구되는 천연가스의 양에 초점을 맞춰 분리막 반응기에서의 원가절감 가능성을 평가한 결과, 분리막 반응기에서 10.94%의 원가절감이 관찰되었다.

반도체레이져를 이용한 온도 및 농도의 계측 (Temperature and Concentration measurement using Semi-conductor diode laser)

  • 정대헌;노동순;지전유이
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.168-174
    • /
    • 2000
  • A diode laser sensor system based on absorption spectroscopy techniques has been developed to measure $CO_2$ concentration and temperature non-intrusively in high temperature combustion environments using a 2.0 ${\mu}m$ DFB(Distributed Feedback) laser. Two optics was fabricated in pig-tail fashion and all optical components were implemented in a single box. The evolution of measurement sensitivity was done using test cell by changing sweep frequency and $CO_2$ concentration. Gas temperature was determined from the ratio of integrated line strengths. Species concentration was determined from the integrated line intensity and the measured temperature. The result show that the system has 2% error in wide operation frequency range and accuracy of $CO_2$ concentration was about 3%. The system was applied to measure temperature and concentration in the combustion region of a premixed $CH_4$ +air triangular flame. The measurement results of gas temperature agreed well with thermocouple results. Many considerations were taken into account to reduce optical noise, etalon effect, beam steering and base line matching problem. The evaluations results and actual combustion measurement demonstrate the practical and applicability for in-situ and real time combustion monitoring in a practical system.

  • PDF

과산화수소 농축을 위한 투과증발공정 모델링 (Modeling of a Pervaporation Process for Concentrating Hydrogen Peroxide)

  • 구옌후휴;이성택;최수형
    • Korean Chemical Engineering Research
    • /
    • 제49권5호
    • /
    • pp.560-564
    • /
    • 2011
  • 본 연구의 목적은 과산화수소 농축을 위한 투과증발공정의 수학적 모델을 제시하는 것이다. 대상공정은 NASA에서 개발한 것으로 쉘과 멤브레인 튜브들로 구성되어 있다. 쉘과 튜브에는 각각 과산화수소용액과 sweep gas가 향류로 흐른다. 이때 막을 통해 투과증발되는 기체에는 과산화수소보다 물분자가 더 많기 때문에 과산화수소를 농축할 수 있다. 이 공정의 수학적 모델은 투과물의 흡수-확산 메커니즘에 기초한 비선형 편미분 및 대수 방정식, 투과물 플럭스의 온도 의존성에 대한 아레니우스 관계, 그리고 막 모듈 내의 액상 농도와 흐름에 대한 질량 및 운동량 수지식의 형태로 개발하였다. 과산화수소 농축물 농도의 동적 거동은 제안된 모델의 단순화된 형태를 풀어 모사하였고 그 결과값을 NASA 특허에서 보고된 실험자료와 비교하였다.

Analytical and sensitivity approaches for the sizing and placement of single DG in radial system

  • Bindumol, E.K.;Babu, C.A.
    • Advances in Energy Research
    • /
    • 제4권2호
    • /
    • pp.163-176
    • /
    • 2016
  • Rapid depletion of fossil based oil, coal and gas reserves and its greater demand day by day necessitates the search for other alternatives. Severe environmental impacts caused by the fossil fire based power plants and the escalating fuel costs are the major challenges faced by the electricity supply industry. Integration of Distributed Generators (DG) especially, wind and solar systems to the grid has been steadily increasing due to the concern of clean environment. This paper focuses on a new simple and fast load flow algorithm named Backward Forward Sweep Algorithm (BFSA) for finding the voltage profile and power losses with the integration of various sizes of DG at different locations. Genetic Algorithm (GA) based BFSA is adopted in finding the optimal location and sizing of DG to attain an improved voltage profile and considerable reduced power loss. Simulation results show that the proposed algorithm is more efficient in finding the optimal location and sizing of DG in 15-bus radial distribution system (RDS).The authenticity of the placement of optimized DG is assured with other DG placement techniques.

The Fault Diagnosis of a Transformer Using Neural Network and Transfer Function

  • Park, Byung-Koo;Kim, Jong-Wook;Kim, Sang-Woo;Park, Poo-Gyeon;Park, Tae-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.127.2-127
    • /
    • 2001
  • A transformer is one of the most important elements in the power network. Transformer faults could cause costly repairs and be dangerous to personnel. To avoid this, its reliable operation has great significance and, therefore, the diagnosis system of the transformer is necessitated. The dissolved gas-in-oil analysis (DGA) is the worldwide popular method of detecting faults such as a hot spot or partial discharges inside the transformer. DGA, however, is not a reliable technique to identify aging phenomena and mechanical faults including insulation failure, inter-turn short, etc. To overcome the drawbacks of DGA, the transfer function method is used to identify effectively these kinds of the mechanical faults. The transformer has a unique transfer function independent of the shape of the input waveform, which can be evaluated through sweep test. This transfer function changes by winding ...

  • PDF

표면처리 공정에서 발생하는 혼합 폐수의 전기화학적 처리에 의한 중금속의 재활용 및 유기물의 제거에 관한 연구 (A Study on the Recycling of Metals and Removal of Organics By Electrochemical Treatment of Mixed Waste Water of Surface Finishing Industry)

  • 김영석;이중배
    • 한국표면공학회지
    • /
    • 제36권2호
    • /
    • pp.184-193
    • /
    • 2003
  • Cyclic sweep voltametry was performed to investigate the electrochemical behavior of heavy metal ions and the organic additives in surface finishing process. And electrolysis using parallel plate electrode electrolyzer was carried out to simulate the treatment of real waste water. Results showed that more than 99 percent of Cu was recovered and selective recovery of Cu in mixed waste water was possible, but the possibility of economical recovery of Ni and Cr were very low due to the evolution of hydrogen gas. Electrochemical oxidation of cyanide and organic additives on anode showed very excellent removal rate. The complete removal of several hundred ppm of cynide was possible within several tens minutes and organics within 2 or 3 hours. Even in case of concentrate waste water, the complete removal of COD by using NaCl and air stirring seemed to be possible.