• Title/Summary/Keyword: Suture materials

Search Result 188, Processing Time 0.029 seconds

Tissue reactions to suture materials in the oral mucosa of beagle dogs

  • Kim, Jae-Seok;Shin, Seung-Il;Herr, Yeek;Park, Joon-Bong;Kwon, Young-Hyuk;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.4
    • /
    • pp.185-191
    • /
    • 2011
  • Purpose: The objective of this study was to compare and evaluate the inflammatory responses of three widely used suture materials in the keratinized gingiva and buccal mucosa of beagle dogs. Methods: Silk, polyglycolic acid, and nylon sutures were placed within the mandibular keratinized gingiva and maxillary buccal mucosa of four male beagle dogs. Biopsies were taken 3, 7, and 14 days after suturing. Specimens were prepared with hematoxylineosin stain for evaluation under a light microscope. Results: The suture materials placed in the oral mucosa elicited more inflammatory reactions than did those placed in the keratinized gingiva. The multifilament suture materials caused more inflammatory tissue reactions than did the monofilament suture materials in the oral mucosa. Conclusions: If oral hygiene is well maintained and suture materials are placed in the keratinized gingiva, silk, nylon, and polyglycolic acid are considered to be proper suture materials for oral surgery. However, it is advisable to use monofilament suture materials if the suture site is within the oral mucosa.

The Mechanical Appearances and Microscopic Tissue Reactions of the Suture Materials in vivo (생체내 이식된 흡수성 봉합사들의 물리적 성질 변화와 조직 소견에 관한 연구)

  • 김남중;김명철
    • Journal of Veterinary Clinics
    • /
    • v.13 no.2
    • /
    • pp.184-194
    • /
    • 1996
  • A comparative study of three absorbable suture materials of chromic catgut, Dexon II (a polyglycolic acid suture with a polycaprolate coating system) and Coated Vicryl (a polyglactin 910 suture with a glycolide-lactide-calcium stearate coating system) was undertaken in terms of tensile strength, breaking elongation, appearances of the suture materials in the subcutaneous layer of rats and of tissue reaction in the intramuscular layer of rats. The initial tensile strength of chromic catgut and the tensile strength after 21 days were about 1.55 kg and 0.19 kg, respectively. Those of Dexon II were about 2.01 kg and 0. 20 kg, respectively. Those of Coated Vicryl were about 2.39 kg and 0.48 kg, respectively. Coated Vicryl showed the highest tensile strength among the three materials during the whole period. On the other hand, Dexon II showed the highest breaking elongation among the three materials during the first week. But the breaking elongation of Dexon II rapidly continuously decreased during the whole period. The appearances of the suture materials in the subcutaneous layer of rats showed that chromic catgut was the fastest among the three materials, whereas it formed comparatively much connective tissue. The intramuscular absorption rate and tissue reaction of Dexon II were similar to those of Coated Vicryl. The intramuscular absorption rate of these was fairly late when compared with chromic catgut. And the tissue reaction appearance of these showed the formation of a granuloma with foreign body giant cells, macrothages and epitheloid cells by the 28th day in the experimental period.

  • PDF

Tissue Reaction to Chromic catgut, Polyglycolic acid and Nylon Sutures in the Rumen Wall of Goats (염소의 제 1위벽에 있어서 Chromic catgut, Polyglycolic acid 및 Nylon 봉합사에 대한 조직반응)

  • Ahn Keun-Seung;Nam Tchi-Chou;Cheong Chang-Kook
    • Journal of Veterinary Clinics
    • /
    • v.3 no.2
    • /
    • pp.299-307
    • /
    • 1986
  • The each rumen of six goats was incised and sutured with chromic catgut, polyglycolic acid and nylon. Tissue reaction to each suture materials was observed and comared at the 7th, 14th and 21st post-operative days. The predominent inflammatory cells around suture materials are macrophages, fibroblast and neutrophils. A few lymphocytes was infiltrated around suture materials. Infiltration of neutrophils was rapidly diminished but infiltration of macrophages, fibroblasts and lymphocytes were persisted. The overall grade of tissue reaction varid by suture materials. At the 7th post-operative days, tissue reaction to chromic catgut was most prominant and that of polyglycolic acid and nylon was moderate. At the 14th and 21st postoperative days, tissue reaction to each suture materials was not greatly different.

  • PDF

Surgical Treatment of Achilles Tendon Rupture with Absorbable Suture Materials Only (흡수성 봉합사만를 이용한 아킬레스건 파열의 수술적 치료)

  • Bae, Su-Young;Park, Jae Gu;Jung, Eui Yub
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.3
    • /
    • pp.196-202
    • /
    • 2013
  • Purpose: To report the clinical results from using absorbable suture materials instead of nonabsorbable materials which have been used more commonly to repair Achilles tendon. Materials and Methods: We retrospectively reviewed 21 cases of acute Achilles tendon rupture, treated surgically from 2004 to 2011. Mean follow-up period is 6 months. We repaired Achilles tendon using size 1 Vicryl (Polyglactin 910, Ethicon) for core suture and size 3-0 Vicryl for epitendinous suture. At three months after surgery, we evaluated clinical results with single heel raise height by centimeters, differences of calf circumference and passive range of motion of ankle joint, compared to contralateral side. Also we recorded clinical results with subjective satisfaction grades. Results: At three months after surgery, 20 of 21 patients were able to perform single heel raise over 5 cm in height. Calf circumference differences were less than 1 cm in 12 cases, between 1 cm to 3 cm in 5 cases, more than 3 cm in 4 cases. There was no difference in range of passive motion in 19 cases. All patients satisfied with daily activity except 2 cases with mild discomfort. There was no complication such as rerupture, elongation or infection. Conclusion: We experienced excellent clinical results from repairing Achilles tendon with using absorbable suture materials in terms of functional outcomes and patient's satisfaction without any complication. So we may consider using absorbable suture materials instead of nonabsorbable materials to repair Achilles tendon.

Comparative Study of Tissue Response of Various Suture Materials in Rats (수종의 봉합사의 조직반응에 관한 비교연구)

  • Kim, Jae-seok;Park, Joon-Bong;Lee, Man-Sup;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.113-127
    • /
    • 2002
  • The purpose of this study is to evaluate histologically the tissue response and resorption of various nonresorbable and resorbable suture materials used for periodontal surgery, using a subcutaneous model on the dorsal surface of the rat. In this study, 10 Sprague-Dawley male rats (mean BW 150gm) were used and the commercially available materials included polyglactin 910, pain gut, nylon, e-PTFE. Animals were sacrificed at 3 days, 1, 2 and 4 weeks after implantation of various nonresorbable and resorbable suture materials. Specimens were prepared with Hematoxylin-Eosin stain for light microscopic evaluation. The results of this study were as follows: 1. Resorption : The resorption of plain gut was showed at 1 week after implantation, was lost their structure and almost resorbed at 4 weeks. The resorption of polyglactin 910 was started at 2 weeks and slowly absorbed untill 4 weeks. 2. Tissue response : Plain gut showed persistent and severe inflammatory reactions from 3 days to 4 weeks. Polyglactin 910, e-PTFE and nylon showed mild inflammatory reactions. Suture material should be biocompatible and be able to be functioned until tissue tensile strength reaches maximum level. In this study, polyglactin 910, nylon and e-PTFE are considered to be proper suture materials for periodontal surgery.

SUTURE TECHNIQUE FOR SUCCESSFUL GUIDED BONE REGENERATION ; PRELIMINARY REPORT OF DOUBLE LAYERED SUTURE TECHNIQUE WITH SUBGINGIVAL SUTURE (성공적인 골유도재생술을 위한 봉합술 : 점막하 봉합법을 이용한 이중 봉합술의 예비 보고)

  • Kim, Young-Bin;Cho, Sung-Dae;Leem, Dae-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.1
    • /
    • pp.86-91
    • /
    • 2009
  • The success of implants essentially depends on a sufficient volume of healthy bone at the recipient site during implant placement. In patients who have the severe alveolar bone resorption or pneumatized maxillary sinus, it should be performed that bone regeneration procedure before implant placement. Development of barrier membrane makes it possible that predictable result of alveolar bone reconstruction. Many kind of materials used for barrier membrane technique are introduced, non-absorbable or absorbable membranes. But, when operation site was ruptured with membrane exposure, bacterias can be grow up at the bone graft site. Then morphology and migration of fibroblast will be changed. It works as a negative factor on healing process of bone graft site. In oral and maxillofacial department of Chonbuk national university dental hospital, we use variable suture technique like as subgingival suture, vertical mattress suture, simple interrupted suture, if need, tenting suture after GBR or block bone graft. Within these suture technique, wound healing was excellent without complication, so now we take a report of suture technique in reconstruction of alveolar bone surgery.

Changes of Tracheal Anastomosis Site in Growing Rats (흰쥐에서 기관절제 단단 문합부의 성장에 따른 변화)

  • 박희철
    • Journal of Chest Surgery
    • /
    • v.26 no.5
    • /
    • pp.343-348
    • /
    • 1993
  • Growth of suture line and anastomosis is required for long-term success after the tracheal and bronchial surgery in infant and pediatric patient. We used various suture materials in these cases, but the results were differ. To select the adequate suture material in tracheal surgery, we tried next. Tracheal anastomoses were performed in 150 Sprague Dawley rats, aged 4 to 8 [mean 5.8] weeks and weight 62 to 106[mean 83.6] gram, to compare polydioxanone[PDS] 7-0, polyglactin 910[Vicryl]7-0, and polypropylene [prolene] 8-0 suture materials. In 150 rats, only 29[20%] were lived over 300 days, and the weight was 250 to 320[mean 289.5]gram. Cross sectional area of the anastomoses and two or three tracheal rings below anastomosis site were measured under microscope, and calculated and compared as Hsieh`s equition. Cross-sectional area,anastomosis site/normal site 100, were 89.4 $\pm$ 5.34% in PDS group[n=9], 75.7 $\pm$ 6.06% in Vicrylgroup [n = 10], and 80.8$\pm$ 4.06% in Prolene group[n = 10]. Histopathologic studies were done for all autopsies or put in death around 300 days postoperatively. PDS absorblion was not seen 16 weeks after suture but disappeared over 24 weeks slide. Vicryl absorbtion was noted postoperative 8 to 16 weeks, with marked tissue reaction. Prolene showed least tissue reaction, but the suture material was persisted with regional fibrotic capsule.Causes of death were respiratory failure in 76 cases, tracheal rupture in 22 cases, hemorrhage, biting, starvation and etc. in 23 cases. With the brief review of literatures, we report the results.

  • PDF

AN EXPERIMENTAL STUDY OF TISSUE REACTION OF ABSORBABLE SUTURE MATERIALS (수종(數種)의 흡수성(吸收性) 봉합사(縫合絲)가 조직반응(組織反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Song, Sun-Chul;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.4
    • /
    • pp.381-390
    • /
    • 1991
  • The purpose of this study was to select the absorbable suture material with the lowest level of foreign body reaction in the extraoral field. The absorbable sutures tested were polyglactin 910(Vicryl), polyglycolic acid(Dexon), and chromic gut. Black silk served as to control suture. Eighteen domestic rabbits served as the animal model for testing purposes. After shaving the fur, A six centimeter incision was made in the hind quarter of all eighteen animals. Each wound was then closed wit two Vicryl, two Dexon, and two chromic gut sutures. All wounds were closed in the same manner. A similar wound was made on the oppsite side and closed with black silk suture. Three rabbits were then sacrificed on postoperative day one, three, seven fourteen, twenty-one, and twenty-eight. The surgical sites were then examined histologically. 1. On days one, three, and seven all suture materials as a similar severe level of inflammatory response. On the fourteenth day the inflammatory reaction of Vicryl was minimal, chromic gut was moderate, and Dexon was severe, Black silk control groups demosnstrated the most severe levels of inflammation of all sutures tested from day fourteen to twenty-eight. 2. On the fourteenth day all absorbable suture materials demonstrated similar minimal levels of resorption. At twenty-eight days Vicryl demonstrated a greater amount of resorption than Dexon or cromic gut suture. There was no resorption noted in the black silk control groups through day twenty-eight. 3. Due to its decreased level of inflammatory response in the animal model, Vicryl might be expected to as a decreased level of response in humans. It is felt that Vicryl is preferred to Dexon or chromic gut for extraoral suturing.

  • PDF

TISSUE HEALING RESPONSE OF INCISED WOUND SUTURED BY STAPLES AND VARIOUS SUTURE MATERIALS (Staple과 수종의 봉합물의 봉합부위 창상치유 조직반응)

  • Suh, Min-Jung;Lee, Jae-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.500-514
    • /
    • 1996
  • The purpose of this study was to observe the tissue response in applying staples and various suture materials to both scalp and buccal mucosa in rabbits. 18 rabbits were divided into 6 groups. The incised wounds of both scalp and buccal mucosa were sutured with staples, polyglactin 910, chromic catgut, mer silk and nylon. The experimental animals were sacrificed after 1, 3, 5, 7, 10, 14 days posto peratively 3 animals at one time. The tissue was stained with Hematoxylin and eosin, and Masson's Trichrom. In light microscopic examinations, the sutured sites were examined histologi cally according to 6 degrees about inflammation and collagen deposit. The results were obtained as follows, 1. The chromic catgut, an absorbable suture material, was absorbed by 7 days, whereas polyglactin 910 and mersilk began to get absorbed after 7 days. 2. Mersilk manifested a broad range of inflammation in the scalp, and both staple and nylon showed a severe inflammatory reaction in the buccal mucosa. 3. With polyglactin 910, both tissue samples showed only minor foreign body reaction, however in the scalp, the process of fibrosis took place compara tively slowly, whereas in the buccal mucosa, it occurred promptly and manifested active fibrosis by 7 days. 4. Mersilk showed widespread a matrix formation in both scalp and buccal mucosa, and showed the most severe inflammatory reaction by 3 days, which did not seem to decrease even after 7 days. 5. Both staple and nylon showed relatively a severe inflammatory reaction, however fibrosis took place rather promptly compared to the other groups. 6. Generally, in the buccal mucosa fibrosis occurred more promptly than in the scalp in both control and experimental groups. 7. Retention of the suture material and stability of the knot were the best with the staple, and better stability was manifested by the multi-stranded poly glactin 910 and mersilk than singlestranded chromic catgut and nylon. From above results, in the buccal mucosa absorbable suture materials especially polyglactin 910 showed better response in the aspect of inflammatory reaction, while in the scalp monofilament suture materials such as staple and nylon manifested a early fibrosis and collagen formation.

  • PDF

Evaluation of the Midpalatal Suture Maturation in Young Koreans Using Cone-Beam Computed Tomography

  • Kim, In-Seok;Kim, Hye-Won;Choi, Young-Jun;Choi, Won-Cheul
    • Journal of Korean Dental Science
    • /
    • v.11 no.1
    • /
    • pp.1-4
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the ossification and maturation of the midpalatal suture in young Koreans using cone-beam computed tomography (CBCT). Materials and Methods: The study sample consisted of 40 patients with ages from 8.2 to 23.6 years who visited the Department of Orthodontics, Chung-Ang University Dental Hospital. CBCT images were taken for diagnosis. From the CBCT image, morphological stages and Hounsfield units (HU) of midpalatal suture were obtained to evaluate the midpalatal suture maturation. Spearman's correlation coefficients were calculated to analyze relationships between chronological age, morphological stage, and HU. Result: There was a wide variation in the morphology of the midpalatal suture in each age group. It showed a modest relationship between the chronological age and the degree of morphological stages. Also there was a modest relationship between the chronological age and HU. In contrast, there was a significant relationship between morphological stages and HU of midpalatal suture (P<0.01). Conclusion: CBCT images can be used for the evaluation of midpalatal suture maturation. For the estimation of the prognosis of rapid maxillary expansion, CBCT may be reliable for the assessment of the maturation of the midpalatal suture.