• 제목/요약/키워드: Sustained load

검색결과 113건 처리시간 0.026초

30(kVA) 초전도발전기 제작 및 특성 (Fabrication and Characteristics of 30〔kVA〕 Superconducting Generator)

  • 손명환;권영길;백승규;박도영;이언용;조영식;류강식
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제3권2호
    • /
    • pp.32-38
    • /
    • 2001
  • A 30[kVA] superconducting generator (SCG) is built and tested at Korea Electrotechnology Research Institute (KERI) in Korea. This superconducting generator has an air-gap winding instead of the typical steel teeth structure. The rotor has 4 field coils of race-track type with NbTi superconducting wired. The rotor is composed of two dampers and a liquid helium composed of two dampers and a liquid helium container in which the field poles reside. The space between the outermost damper and the container is vacuum insulated. A ferrofluid seal is used between the stationary part connected to the couping and the rotor. A helium transfer coupling(HTC) has 3 passages of the recovered heilum gas and a gas flow control system. The open circuit test and sustained short circuit test are preformed to obtain the open circuit characteristics (OCC) and short circuit characteristics (SCC) Also. the test results usder the light load (up to 3.6[kW]) are given. The structure, manufacturing and basis test of the 30[kVA]SCG are discussed.

  • PDF

주물 산업의 수익력 극대화를 위한 관리부문의 TPI 최적화 연구 (An Optimization Study on Maximizing the Earning Power of Casting Industry for Management through TPI)

  • 강병노;이창호
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.327-333
    • /
    • 2014
  • Changes in the business environment in which intense and sustained growth and survival must meet a variety of customer needs (Q, C, D) and business side of the enterprise for profit structure reformation is absolutely necessary for innovation activities. So far, management of innovation in method BPR, PI, OVA, 6 Sigma, Strategic Purchasing, PPM, SCM etc. are being introduced. However, they have a limit of partial optimization and improvement-oriented techniques. So this paper studied the TPI(Total Profit Innovation) application in order to derive empirical methodology to maximize profitability for the domestic S foundry factory. To this end, long-term gains through structural analysis and intensity analysis to ensure continued growth and profitability strategy are devised through management Innovation analysis. And improvement projects was presented to solve main issues of five categories(Inventory, Sales Mix, Cost, Quality Cost, Skill and Work-load) We will expect the office productivity improvement and financial performance improvement and then continually accumulate and review the results.

Modeling, Dynamic Analysis and Control Design of Full-Bridge LLC Resonant Converters with Sliding-Mode and PI Control Scheme

  • Zheng, Kai;Zhang, Guodong;Zhou, Dongfang;Li, Jianbing;Yin, Shaofeng
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.766-777
    • /
    • 2018
  • In this paper, a sliding mode and proportional plus integral (SM-PI) control combined with self-sustained phase shift modulation (SSPSM) for LLC resonant converters is presented. The proposed control scheme improves the transient response while preserving good steady-state performance. An averaged large signal model of an LLC converter with the ZVS modulation technique is developed for the SM control design. The sliding surface is obtained based on the input-output linearization concept. A system identification method is adopted to obtain the transform function of the LLC resonant converter, which is used to design the PI control. In order to reduce the inherent chattering problem in the steady state, the combined SM-PI control strategy is derived with fuzzy control, where the SM control is responsive during the transient state while the PI control prevails in the steady state. The combination of SSPSM and the SM-PI control provides ZVS operation, robustness and a fast transient response against step load variations. Simulation and experimental results validate the theoretical analysis and the attractive features of the proposed scheme.

Bilinear elastodynamical models of cracked concrete beams

  • Pandey, Umesh Kumar;Benipal, Gurmail S.
    • Structural Engineering and Mechanics
    • /
    • 제39권4호
    • /
    • pp.465-498
    • /
    • 2011
  • Concrete structures are generally cracked in flexural tension at working loads. Concrete beams with asymmetric section details and crack patterns exhibit different flexural rigidity depending upon the sense of the applied flexural moment. In this paper, three different models, having the same natural period, of such SDOF bilinear dynamical systems have been proposed. The Model-I and Model-II have constant damping coefficient, but the latter is characterized by two stiffness coefficients depending upon the sense of vibration amplitude. The Model-III, additionally, has two damping coefficients as well. In this paper, the dynamical response of Model-III to sinusoidal loading has been investigated and compared with that of Model-II studied earlier. It has been found that Model-III exhibits regular and irregular sub-harmonics, jump phenomena and strong sensitivity to initial conditions, forcing frequency, system period as well as the sense of peak sinusoidal force. The constant sustained load has been found to affect the natural period of the dynamical system. The predictions of Model-I have been compared with those of the approximate linear model adopted in present practice. The behaviour exhibited by different models of the SDOF cracked elastic concrete structures under working loads and the theoretical and practical implications of the approach followed have been critically evaluated.

전원개발계획을 고려한 전력산업의 비용구조 및 규제효과분석 (The Measurement of Efficiency Structure and Regulatory Effects in Korean Electric Industry with Power Development Plan)

  • 이창호;권영한
    • 자원ㆍ환경경제연구
    • /
    • 제11권2호
    • /
    • pp.233-260
    • /
    • 2002
  • This paper tries to analyze the efficiency structure and regulatory effects in electric power industry by using total factor productivity and indices based on cost function method. This paper performed an empirical analysis on the efficiency improvement and optimal scale taking the cost aspect in electricity industry into account. By expanding the cost structure framework, this paper proposes the analytical method regarding the needs of technology regulation and presents the empirical results which can be verified. Hence, this work can play a key role in decision-making of the national power development and regulatory policy. The empirical result indicates that the electricity industry in Korea has been in the state of economies of scale until 1980s, However, due to sustained growth of power generation, economies of scale declined and subsided after 1980s and then diseconomies of scale is shown recent years. The analysis on the effect of technology regulation shows the national large-scale base-load power plant development-oriented policy until so far contributed substantial cost effect to the electricity industry. The empirical result indicates that the reserve requirement as one of means of technology regulation policy did not contribute to the economies of scale but positive effect on the total factor productivity in Korea.

  • PDF

Experimental investigation of creep and shrinkage of reinforced concrete with influence of reinforcement ratio

  • Sun, Guojun;Xue, Suduo;Qu, Xiushu;Zhao, Yifeng
    • Advances in concrete construction
    • /
    • 제7권4호
    • /
    • pp.211-218
    • /
    • 2019
  • Predictions about shrinkage and creep of concrete are very important for evaluating time-dependent effects on structural performance. Some prediction models and formulas of concrete shrinkage and creep have been proposed with diversity. However, the influence of reinforcement ratio on shrinkage and creep of concrete has been ignored in most prediction models and formulas. In this paper, the concrete shrinkage and creep with different ratios of reinforcement were studied. Firstly, the shrinkage performance was tested by the 10 reinforced concrete beams specimens with different reinforcement ratios for 200 days. Meanwhile, the creep performance was tested by the 5 reinforced concrete beams specimens with different ratios of reinforcement under sustained load for 200 days. Then, the test results were compared with the prediction models and formulas of CEB-FIP 90, ACI 209, GL 2000 and JTG D 62-2004. At last, based on ACI 209, an improved prediction models and formulas of concrete shrinkage and creep considering reinforcement ratio was derived. The results from improved prediction models and formulas of concrete shrinkage and creep are in good agreement with the experimental results.

강재로 구속된 프리스트레스트 콘크리트 합성거더의 정적 및 피로거동 (A Study on the Static and Fatigue Behavior of Steel-Confined Prestressed Concrete Girder)

  • 김정호;박경훈;황윤국;이상윤
    • 한국강구조학회 논문집
    • /
    • 제16권6호통권73호
    • /
    • pp.725-736
    • /
    • 2004
  • 최근 국내에서 I형 거더의 외부가 강재로 이루어지고 내부에 무근콘크리트가 채워져 합성된 거더에 프리스트레스를 도입하여 경간을 장대화할 수 있는 새로운 개념의 합성거더인 '강재로 구속된 프리스트레스트 콘크리트 합성거더(Steel-Confined Prestressed Concrete Girder; SCP Girder)'가 개발되었다. 또한 개발된 거더를 실물크기로 제작하여 시공성을 확인하고 정적하중 재하에 의한 파괴실험을 통해 공용 중 안전성에 대한 실험적 검증이 수행되었다(김정호 등, 2002). 그러나 SCP 합성거더의 실용화를 위해서는 교량 파손의 주원인이 주행하중의 영향에 의한 피로파손인 점을 고려하여 반복하중에 대한 피로거동의 연구 및 피로 안전성 확보가 요구된다. 따라서 본 연구에서는 SCP 합성거더에 대한 피로거동 특성을 파악하고 피로설계를 위한 기초적인 자료를 제시하기 위해 피로실험을 실시하였다. 피로실험을 위한 시험체의 제작은 1등교에 해당하는 설계활하중(DB-24)에 대하여 10m 지간으로 설계 제작하였으며, 실험결과 도로교설계기준(한국도로교통협회, 2000)의 상세피로범주에 따른 허용피로응력범위를 초과하지 않는 것으로 나타났다. 또한 초기정적재하를 통해 설계의 타당성과 구조적 거동을 분석하였으며, 피로실험 종료 후 거더 외부를 이루고 있는 강재를 제거하여 내부콘크리트의 상태를 관찰하였다.

무피복 합성보의 내화성능에 대한 실험 및 해석적 연구 (Experimental and Numerical Study of Fire Resistance of Composite Beams)

  • 안재권;이철호
    • 한국강구조학회 논문집
    • /
    • 제27권2호
    • /
    • pp.143-153
    • /
    • 2015
  • 본 연구에서는 매립형 합성보와 슬림플로어보의 내화성능평가를 위한 재하가열실험 및 수치해석연구를 수행하였다. 이를 통해 화재 시 합성보의 온도 및 처짐 변화를 분석하고 하중비, 철근, 화재노출면 등의 합성보 설계변수들이 내화성능에 미치는 영향을 비교하였다. 화재실험결과 매립형 합성보와 슬림플로어보의 경우 강재의 온도상승이 일반형 합성보에 비해 상당히 지연됨을 확인하였다. 그리고 매립콘크리트 내에 보강된 철근은 최소 90분까지는 상온강도를 발휘할 수 있는 온도이하를 유지하였다. 무보강 매립형 합성보, 철근을 보강한 매립형 합성보와 슬림플로어보의 경우 처짐량 제한 기준만으로도 2시간 이상의 내화성능을 달성하였다. 이는 무피복 매립형 합성보와 슬림플로어보가 강재보의 내화성능을 증진하는 합리적인 대안이 될 수 있음을 시사한다. 합성보 재하가열실험에 대하여 ABAQUS를 활용한 유한요소해석을 수행한 결과 전체적인 처짐 양상 및 내화시간의 예측에 있어서 해석결과가 실제 실험결과를 신뢰성 있게 구현하고 있음을 확인하였다.

측두하악관절의 골관절염 (Osteoarthritis of the Temporomandibular Joint)

  • 이정윤
    • Journal of Oral Medicine and Pain
    • /
    • 제38권1호
    • /
    • pp.87-95
    • /
    • 2013
  • 측두하악관절 골관절염은 측두하악장애의 한 형태로 관절조직의 생리적 내성을 초과하는 기능적 부하가 지속적으로 관절에 가해졌을 때 관절연골 및 연골하 골조직의 점진적 파괴와 이차적 염증을 특징으로 하는 질환이다. 관절면에 가해지는 물리적 하중은 관절내에서 기질파괴 단백효소나 염증성 cytokine, 유리기의 활성을 증가시키고, 그에 따라 골조직의 퇴행과 재형성 사이의 균형을 깨뜨려 골조직의 흡수를 야기한다. 최근에는 물리적 하중 이 외에 비만세포에서 유래하는 adipokine이 골흡수를 증가시킨다는 보고들이 있으나 측두하악관절에 적용하기에는 아직 추가적인 연구가 필요하므로 현재로서 골관절염의 치료는 관절의 기능적 부하를 줄이고 환자의 생리적 내성을 증가시키는 방향으로 이루어져야 한다. 임상증상은 충분한 기간 정확한 술식대로 시행한 물리치료, 약물치료, 교합안정 장치치료 등의 보존적 처치와 관절강내 주사요법이나 관절세척술 및 관절경 수술과 같은 추가적인 외과적 처치에 의해 성공적으로 조절될 수 있으나, 임상증상의 개선이 골파괴의 중지와 재형성을 담보하는 것은 아니므로 임상증상의 개선 이 후에도 지속적인 골변화의 추적관찰이 필요하다. 또한, 골변화 활성 자체를 직접적으로 조절할 수 있는 활용 가능한 치료법이 없는 한, 지속적인 동기유발과 행동조절을 통해 관절에 가해지는 기능적 부하를 환자 스스로 조절할 수 있도록 끊임없이 교육하는 것이 골변화를 겪는 측두하악관절로 하여금 보다 이른 시기에 보다 유리한 정형적 안정에 도달하게 함으로써 골관절염을 보다 성공적으로 조절할 수 있는 길이라고 할 수 있다.

장기하중이 FRP-보강근 콘크리트 보의 휨균열폭에 미치는 영향 (Effect of Long-Term Load on Flexural Crack Widths in FRP-Reinforced Concrete Beams)

  • 최봉섭
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.694-701
    • /
    • 2018
  • FRP-보강근 콘크리트 부재들은 FRP-보강근이 철근에 비해 낮은 탄성계수와 부착강도를 갖고 있어 철근콘크리트 부재에 비해 과도한 균열폭의 가능성이 클 수 있다. 따라서 외국의 기준들에서는 FRP-보강근 콘크리트 부재의 균열제어를 위하여 허용균열폭의 제한규정을 두고 있는데, ACI 440.1R-15 설계지침에서는 최대 보강근 간격으로 제어하는 간접적인 방법으로 제안하고 있다. 그러나 제안식은 아직까지 장기하중이 균열폭에 미치는 시간종속적인 효과를 반영하지 못하고 있다. 이에 본 연구에서는 장방형단면뿐만 아니라 T형단면의 FRP-보강근 콘크리트 보를 대상으로 장기실험을 통하여 얻어진 실험결과를 바탕으로 단면형태별 균열폭 특성을 구분하여 파악하므로 써 장기균열폭 예측모델을 제안하는데 필요한 기초자료를 제공하고자 하였다. 따라서 단면형태별로 각각 한 개씩 의 철근콘크리트 비교시험체를 포함한 4개의 장방형보와 4개의 T형 보로 구성된 총 8개의 시험체를 제작하여 시공하중의 영향을 고려한 1년간 4점 가력 장기휨실험을 수행하였다. 결과로서 시간종속적인 영향을 받는 순수장기균열폭은 철근 시험체에 비해 보강근의 탄성계수가 낮은 GFRP나 AFRP-보강근 시험체에서는 2.6~3.0배 증가하였으나 CFRP-보강근 시험체에서는 1.1~1.4배 증가에 그쳤다. 또한 즉시균열폭을 포함한 총장기균열폭은 장방형단면과 T형단면 시험체에서 평균적으로 각각 즉시균열폭의 약 2.4와 3.1배 증가를 보여주어 보수적으로 각각 2.5와 3.5의 시간종속계수를 구분하여 제안하였다.