• Title/Summary/Keyword: Suspension insulator

Search Result 83, Processing Time 0.022 seconds

A study on properties of 400kN porcelain suspension insulator for transmission line by analyzing of raw materials (400kN 송전용 자기애자의 재질에 따른 특성 연구)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il;Jung, Gil-Jo;Min, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1637-1639
    • /
    • 2004
  • In order to analyze the physical and chemical characteristics of the home production porcelain insulators by change of the alumina addition amount, 36000lbs ball socket type suspension insulators which were manufactured in 1989, 1995 and 2001 removed in transmission line and an experiment was performed. By the result, 8 [wt.%] alumina that influences the mechanical properties and arc resistance properties in case of insulators that were manufactured in 1989 was contained, and the relative density and the fracture toughness of insulators appeared by 94.2% and 1.4 [MPa $M^{1/2}$], respectively. However, 12 [wt.%] alumina was contained in case of insulators that were manufactured in 1995, and the relative density and the fracture toughness of insulators appeared preferably lower by 92% and 1.3 [MPa $M^{1/2}$], respectively. Amount of alumina was contained most by 17 [wt.%] in case of insulators that were manufactured in 2001. It was confirmed that the electrical and mechanical characteristics such as the relative density and the fracture toughness appeared excellently by 96% and 1.7 [MPa $m^{1/2}$], respectively.

  • PDF

Accelerating Aging of Transmission Line Porcelain Suspension Insulators by Autoclaving

  • Lee, Won-Kyo;Choi, In-Hyuk;Shin, Koo-Yong;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.147-150
    • /
    • 2008
  • Porcelain suspension insulators aged for 1, 5 and 10 years on Korean transmission lines and new insulators are tested for autoclave expansion. The compressive strength of the insulators aged in an autoclave with conditions of $250\;^{\circ}C$ and at 20 atm for 30 minutes, was about $7.6\;kgf/mm^2$, which is close to that measured on insulators aged for 10 years in the field. From simulation results, the cement displacement changed linearly with temperature. At a temperature of $200\;^{\circ}C$, the shear stress was approximately $7\;kgf/mm^2$; a stress that is brought about by a 0.07 % expansion of the cement. It is evident that the cement would fracture at a 0.07 % expansion, because the cement has about 7 to $9\;kgf/mm^2$ flexure strength. A turning point in the shear stress with mechanical load occurred at 0.02 % cement expansion. From an analysis of the porcelain body it is shown that there is sufficient margin of strength to guard against fracture of the porcelain body even for a cement expansion more than 0.12 %.

The Inner Defect Detection of Suspension Insulators by Lightning Impulse (뇌 임펄스를 이용한 현수애자의 내부결함 검출)

  • 송일근;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.6
    • /
    • pp.83-90
    • /
    • 1995
  • This paper analyzed the electrical field strength of porcelain suspension insulator used various testing methods in order to present the causes and countermeasure for the puncture failure by the inner minute defect. A power frequency puncture test and a step-front-of-wave flashover voltage test were conducted. The failed specimen of these samples was analyzed material characteric observed the cross-sectional picture by the scanning electron microscope, and tested the autoclave expansion for the portland cement using the metal bond agent. The porcelain made a progress the failure by the thermal expansion coefficient of the different material. The inner detecting technique on behalf of the puncture failure protection is presented such as the steep-front-of-wave flashover voltage test.

  • PDF

A Study on Salt Damage Pollution Forecasting by Measuring Leakage Current

  • Lee, Dae-Dong;Hyun, Dong-Seok;Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.7
    • /
    • pp.47-56
    • /
    • 2010
  • Faults due to salt damage prevent the provision of stable power supply because they affect large areas and require much time and man power for recovery. Korea, three sides of which are surrounded by sea, is especially exposed to the impact of sea winds and typhoons. Therefore, salt damage to power facilities is one of the greatest problems of Korea's power system. To prevent salt damage pollution of insulators, the salt damage deposit on the insulators is regularly measured, and the insulators are washed when their salt damage deposits are expected to reach a critical level. When salt is detected on the insulators, however, errors are likely to occur according to different workers and environments. Therefore, a leakage current measurement method was proposed in this study to check the salt damage pollution level and reduce these errors.

FEA Simulations and Tests of Rubber Insulator for Truck Suspension

  • Hur, Shin;Woo, Chang Su
    • Elastomers and Composites
    • /
    • v.52 no.4
    • /
    • pp.303-308
    • /
    • 2017
  • In this study, finite element modeling and material property tests are performed for the finite element analysis of rubber isolator parts which support the engine and isolate the vibration. As a result of the P direction analysis of the rubber isolator parts, the static stiffness in the P direction was 44.2 kg/mm, which is well within the error of 5% as compared with the test result of 46.1 kg/mm. The static stiffness of the rubber isolator parts in the Q direction was calculated to be 7.9 kg/mm, which is comparable to the test result of 8.6 kg/mm, with an error of less than 8%. As a result of the analysis on the Z direction, the static stiffness was calculated as 57.7 kg/mm, and the test results were not available. Through this study, it is expected that the time and cost for prototype development can be reduced through nonlinear finite element analysis for rubber isolator parts.

The Comparison of EPDM and Silicone in Housing Materials of Polymeric Suspension Insulators (EPDM 및 실리콘 재질의 폴리머현수애자의 특성 비교)

  • Lee, Byung-Sung;Lee, Jae-Bong;Song, Il-Keun;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.6-10
    • /
    • 2003
  • In our country, the housing materials of polymeric outdoor insulators have mainly been used EPDM or silicone rubber. EPDM housing materials had been widely used in the field for the first time. The reason why silicone has the high cost of production. But recently, most of the manufacturers that newly developed polymeric insulators make its choice of silicone housing. EPDM showed a good resistance to tracking. We compared the various characteristics for EPDM and silicone insulators that have similar type and design. Silicone insulators have more performance in flashover voltage test and leakage current measurement because of a good water repellent than EPDM ones. Also, the property of EPDM compared with silicone insulators greatly decreased after aging test in combined acceleration ageing facilities for 1000 hours.

  • PDF

Technology of Reliability Evaluation for Suspension Composite Insulator in the Overhead Distribution Lines (배전급 폴리머 현수애자의 신뢰성 평가기술)

  • Park, Hoy-Yul;Kang, Dong-Pil;Kim, Ik-Soo;Shin, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1440-1442
    • /
    • 2002
  • 폴리머 애자는 여러 가지의 외부환경에 의하여 시간의 경과에 따라서 재료의 열화가 진행된다. 폴리머 애자를 평가하는 방법으로 기계적 특성, 전기적 특성, 환경적 특성 등의 평가방법이 있으나 각각의 특성평가에 있어서 국제, 국가 및 단체에 따라서 서로 다르다. 신뢰성 평가기준도 서로 달라 국내 실정에 맞는 폴리머 애자의 신뢰성 향상에 어려움이 있었다. 이러한 문제를 해결하기 위하여 폴리머 애자의 신뢰성 평가기준을 표준화할 필요성이 있다. 본 원고에서는 특고압 가공배전선로에 사용하는 폴리머 현수애자의 신뢰성 평가기준에 대하여 설명하였다. 장기신뢰성 평가를 위하여 다양한 외부환경을 모의하여 복합적인 스트레스를 가할 수 있는 복합가속열화설비에 대하여 설명하고 복합가속열화시험법을 결정하였다.

  • PDF

Thermal Impact Characteristics by Forest Fire on Porcelain Insulators for Transmission Lines

  • Lee, Won-Kyo;Choi, In-Hyuk;Choi, Jong-Kee;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.4
    • /
    • pp.143-146
    • /
    • 2008
  • In this study the thermal impact characteristics by forest fire are extensively investigated using temperature controlled ovens. The test conditions for thermal impact damage are simulated according to the characteristics of natural forest fire. The test pieces are suspension porcelain insulators made by KRI in 2005 for transmission lines. In the thermal impact cycle tests with $300\;^{\circ}C$ thermal impact gradient (-70 to $230\;^{\circ}C$), cycling in 10 minute periods, no critical failures occurred in the test samples even with long cycle times. But in tests with thermal impact gradient from room temperature to $200-600\;^{\circ}C$, cycling in 10 to 30 minute periods, there were critical failures of the porcelain insulators according to the thermal impact gradient and quenching method. In the case of thermal impact by forest fire, it was found of that duration time is more important than the cycling time, and the initiation temperature of porcelain insulator failures is about $300\;^{\circ}C$, in the case of water quenching, many cracks and fracture of the porcelain occurred. It was found that the thermal impact failure is closely related to the displacement in the cement by thermal stress as confirmed by simulation. It was estimated that the initiation displacement by the thermal impact of $300\;^{\circ}C$ is about 0.1 %. Above 1% displacement, it is expected that the most porcelain insulators would fail.

A Numerical Algorithm for Fault Location Estimation and Arc Faults Detection for Auto-Reclosure (자동 재폐로기의 동작책무를 위한 아크전압 판정 및 사고거리 표정 알고리즘)

  • Kim, Byeong-Man;Chae, Myeong-Suk;Zheng, Tai-Ying;Kang, Yong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1294-1303
    • /
    • 2009
  • This paper presents a new numerical algorithm for fault discrimination and fault location estimation when occur to arcing ground and arcing line to line on transmission lines. The object of this paper is developed from new numerical algorithm to calculate the fault distance and simultaneously to make a distinction between transient and permanent faults. so the first of object for propose algorithm would be distinguish the permanent from the transient faults. This arcing fault discrimination algorithm is used if calculated value of arc voltage amplitude is greater than product of arc voltage gradient and the length of the arc path, which is equal or greater than the flashover length of a suspension insulator string[1-3]. Also, each algorithm is separated from short distance and long distance. This is difference to with/without capacitance between short to long distance. To test the validity of the proposed algorithms, the results of algorithm testing through various computer simulations are given. The test was simulated in EMTP/ATP simulator under a number of scenarios and calculate of algorithm was used to MATLAB.

A Study on the Properties of 36,000lb Porcelain Insulators by Contained Alumina of Raw Materials

  • Choi In-Hyuk;Choi Jang-Hyun;Jung Yoon-Hwan;Lee Dong-Il
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.1
    • /
    • pp.8-13
    • /
    • 2005
  • In order to analyze the properties of domestically produced 36,000lb porcelain insulators by change of the alumina addition to raw materials, 36000lb ball socket type suspension insulators that were manufactured in 1989, 1995 and 2001 were removed from transmission lines and an experiment was performed. The results indicated that 8 [wt.%] alumina, which influences the mechanical properties and arc resistance properties in the case of insulators that were manufactured in 1989 was contained, and the relative density and the fracture toughness of insulators appeared by 94.2% and 1.4 [MpaㆍM/sup 1/2/], respectively. However, 12 [wt.%] alumina was contained in the case of insulators that were manufactured in 1995, and the relative density and the fracture toughness of insulators appeared preferably lower by 92% and 1.3 [MpaㆍM/sup 1/2/], respectively. The greatest amount of alumina was contained by 17 [wt.%] in the case of insulators that were manufactured in 2001. It was confirmed that the electrical and mechanical characteristics such as the relative density and the fracture toughness appeared remarkably by 96% and 1.7 [Mpaㆍm/sup 1/2/], respectively.