• Title/Summary/Keyword: Surgical stability

Search Result 267, Processing Time 0.039 seconds

The Comparison of the Effects of Nicardipine and Remifentanil on Fluctuation of Blood Pressure during Controlled Hypotension (유도 저혈압하 양악 교정술 시 Nicardipine과 Remifentanil의 혈역학적 비교)

  • Kim, Eun-Soo;Hwang, Boo-Young;Kim, Cheul-Hong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.10 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Background: Controlled hypotension is used to reduce bleeding and improve surgical conditions during surgery. Nicardipine and remifentanil have been used to induce controlled hypotension in healthy patients. This study compared controllability of nicardipine and remifentanil on hemodynamic stability during controlled hypotension. Methods: Forty healthy patients scheduled for orthognathic two jaw surgery were randomly allocated to nicardipine (group N) and remifentanil (group R) group. After induction of anesthesia, group N (n = 20) was infused with nicardipine to induce hypotension and group R (n = 20) was infused with remifentanil. Mean arterial pressure (MAP) and heart rate (HR) were measured over 5 minute interval. Surgical field rating and blood loss were measured after surgery. Results: HR was lower in group R than group N. MAP was maintained at 50-60 mmHg during controlled hypotension but the fluctuation of blood pressure and HR were more frequent in group N than group R. There were no significant differences in the surgical field rating and blood loss between the groups. Conclusions: Nicardipine and remifentanil enabled controlled hypotension and provided good surgical conditions, but the fluctuation of hemodynamic parameters was more frequent in nicardipine group.

Surgical Treatment of Chronic Lateral Ankle Instability: Repair versus Reconstruction (만성 족관절 외측 불안정성의 수술적 치료: 봉합술과 재건술의 비교)

  • Kim, Keun Soo;Park, Young Uk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.1
    • /
    • pp.1-5
    • /
    • 2019
  • Surgical treatment to restore stability in the ankle and hindfoot and prevent further degenerative changes may be necessary in cases in which conservative treatment has failed. Anatomical direct repair using native ligament remnants with or without reinforcement of the inferior retinaculum is the so-called gold standard operative strategy for the treatment of lateral ankle instability. Non-anatomical lateral ligament reconstruction typically involves the use of the adjacent peroneus brevis tendon and applies only those with poor-quality ligaments. On the other hand, anatomic reconstruction and anatomic repair provide better functional outcomes after the surgical treatment of chronic ankle instability patients compared to a non-anatomic reconstruction. Anatomical reconstruction using an autograft or allograft applies to patients with insufficient ligament remnants to fashion direct repair, failed previous lateral ankle repair, high body mass index, or generalized ligamentous laxity. These procedures can provide good-to-excellent short-term outcomes. Arthroscopic ligament repair is becoming increasingly popular because it is minimally invasive. Good-to-excellent clinical outcomes have been reported after short and long-term follow-up, despite the relatively large number of complications, including nerve damage, reported following the procedure. Therefore, further investigation will be needed before widespread adoption is advocated.

Stability and Considerations of Total Maxillary Setback Le Fort I Osteotomy for the Correction of Maxillary Protrusion (상악전돌의 치료를 위한 상악 후방이동의 안정성 및 고려사항)

  • Lee, Jae-Yeol;Kim, Yong-Il;Yoon, Sang-Yong;Hwang, Dae-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.320-325
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the stability of the total setback of maxilla. It also discussed the surgical considerations of the procedure. Methods: The study consisted of 15 patients (mean age, $25.53{\pm}5.71$) who were treated with total setback Le Fort I osteotomy (with or without additional posterior maxillary impaction). The cone beam computed tomography was obtained before surgery (T0), 3~4 days after surgery (T1), and 6 months after surgery (T2). The surgical changes as well as the relapse of reference points in relation to the reference planes were statistically analyzed. Results: The mean maxillary setback was 2.35 mm. There were posterior movements of A-point ($0.73{\pm}0.83$ mm) during T2-T1. An opening of the nasolabial angle (mean $12.58^{\circ}$) was noted. Conclusion: Total maxillary setback allows combining satisfactory functional and cosmetic results for a number of carefully selected patients.

Analysis of Postural Stability and Daily Energy Expenditure to Manage Tumor Patients' Functional Expectation

  • Caliskan, Emrah;Saygi, Evrim Karadag;Gencer, Zeynep Kardelen;Kurtel, Hizir;Erol, Bulent
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.491-499
    • /
    • 2018
  • Background: Advances in surgical techniques, implant technology, radiotherapy, and chemotherapy have increased the recovery chances of patients with bone sarcomas. Accordingly, patients' expectations on life quality have also increased, highlighting the importance of objective evaluation of the functional results of reconstruction. Methods: Thirteen patients with distal femoral endoprosthesis, who had been followed for an average of 2.9 years were evaluated. Postural stability, daily energy expenditure, muscle power, and range of motion were the four parameters analyzed in this study. The Musculoskeletal Tumor Society (MSTS) score and Toronto Extremity Salvage Score (TESS) were used to assess postoperative function and examine correlations with other parameters. Results: Patients had sedentary activities in 84% of their daily lives. They exhibited a slower speed in the walk across test and a higher sway velocity in the sit-to-stand test (p = 0.005). MSTS scores were significantly correlated with the daily energy expenditure and walking speed. Conclusions: Objective functional results acquired from various clinics will provide significant data to compare reconstruction techniques, rehabilitation protocols, and surgical techniques. In this way, it will be possible to satisfy the expectations of patients that increase in relation to enhanced recovery.

Computer-aided design/computer-aided manufacturing of hydroxyapatite scaffolds for bone reconstruction in jawbone atrophy: a systematic review and case report

  • Garagiola, Umberto;Grigolato, Roberto;Soldo, Rossano;Bacchini, Marco;Bassi, Gianluca;Roncucci, Rachele;De Nardi, Sandro
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.2.1-2.9
    • /
    • 2016
  • Background: We reviewed the biological and mechanical properties of porous hydroxyapatite (HA) compared to other synthetic materials. Computer-aided design/computer-aided manufacturing (CAD/CAM) was also evaluated to estimate its efficacy with clinical and radiological assessments. Method: A systematic search of the electronic literature database of the National Library of Medicine (PubMed-MEDLINE) was performed for articles published in English between January 1985 and September 2013. The inclusion criteria were (1) histological evaluation of the biocompatibility and osteoconductivity of porous HA in vivo and in vitro, (2) evaluation of the mechanical properties of HA in relation to its porosity, (3) comparison of the biological and mechanical properties between several biomaterials, and (4) clinical and radiological evaluation of the precision of CAD/CAM techniques. Results: HA had excellent osteoconductivity and biocompatibility in vitro and in vivo compared to other biomaterials. HA grafts are suitable for milling and finishing, depending on the design. In computed tomography, porous HA is a more resorbable and more osteoconductive material than dense HA; however, its strength decreases exponentially with an increase in porosity. Conclusions: Mechanical tests showed that HA scaffolds with pore diameters ranging from 400 to $1200{\mu}m$ had compressive moduli and strength within the range of the human craniofacial trabecular bone. In conclusion, using CAD/CAM techniques for preparing HA scaffolds may increase graft stability and reduce surgical operating time.

STABILITY OF ORTHOGNATHIC SURGERY FOR CLEFT LIP AND PALATE PATIENTS (구순구개열환자에 대한 악교정수술후 안정성에 대한 연구)

  • Kwon, Tae-Geon;Mori, Yoshihide;Minami, Katsuhiro;Kim, Jong-Bae
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.4
    • /
    • pp.407-413
    • /
    • 2000
  • To evaluate the stability after orthognathic surgery in cleft lip and palate patients using rigid fixation, 20 patients underwent primary repair in childhood and later developed a jaw deformity and malocclusion that required orthognathic surgery were reviewed. Two groups, one of 10 patients performed Le Fort I osteotomy with sagittal split ramus osteotomy and one of 10 patients with sagittal split ramus osteotomy of the mandible, were evaluated. Each group had unilateral cleft only and all alveolar cleft sites had been grafted with autogeneous bone before the orthognathic surgery. The amount of surgical movement and relapse were compared in both horizontal and vertical dimensions. Two-jaw surgery group was more stable than mandibular surgery only group in mandibular position (p< 0.05). Statistically significant relapse was observed in mandibular skeletal point in mandibular surgery group (p<0.05). There was no statistically significant relapse in the skeletal point of two-jaw surgery group. However, the correlation between the horizontal surgical movement and relapse was detected (r = 0.88). This correlation indicates the need of overcorrection. The presence of scar tissues and relatively deficient maxillary bone could be attributed to this close relation between the surgical change and relapse.

  • PDF

Orthognathic surgery for patients with fibrous dysplasia involved with dentition

  • Udayakumar, Santhiya Iswarya Vinothini;Paeng, Jun-Young;Choi, So-Young;Shin, Hong-In;Lee, Sung-Tak;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.37.1-37.7
    • /
    • 2018
  • Background: Fibrous dysplasia (FD) is characterized by the replacement of normal bone by abnormal fibro-osseous connective tissue and typically treated with surgical contouring of the dysplastic bone. When dysplastic lesions involve occlusion, not only is surgical debulking needed, orthognathic surgery for correction of dentofacial deformity is mandatory. However, the long-term stability of osteotomized, dysplastic bone segments is a major concern because of insufficient screw-to-bone engagement during surgery and the risk of FD lesion re-growth. Case presentation: This case report reviewed two patients with non-syndromic FD that presented with maxillary occlusal canting and facial asymmetry. Le Fort I osteotomy with recontouring of the dysplastic zygomaticomaxillary region had been performed. The stability of osseous segments were favorable. However, dysplastic, newly formed bone covered the previous plate fixation site and mild bony expansion was observed, which did not influence the facial profile. Including the current cases, 15 cases of orthognathic surgery for FD with dentition have been reported in the literature. Conclusion: The results showed that osteotomy did not appear to significantly reduce the long-term stability of the initial fixation insufficiency of the screw to the dysplastic bone. However, based on our results and those of the others, long-term follow-up and monitoring are needed, even in cases where the osteotomized segment shows stable results.

INFLUENCE OF IMPLANT FIXTURE DESIGN ON IMPLANT PRIMARY STABILITY (임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향)

  • Oh, Gap-Yong;Park, Sung-Hwa;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.98-106
    • /
    • 2007
  • Statement of problem: Current tendencies of the implant macrodesign are tapered shapes for improved primary stability, but there are lack of studies regarding the relationship between the implant macrodesign and primary stability. Purpose: The purpose is to investigate the effect of implant macrodesign on the implant primary stability by way of resonance frequency analysis in the bovine rib bones with different kinds of quality. Material and method: Fifty implants of 6 different kinds from two Korean implant systems were used for the test. Bovine rib bones were cut into one hundred pieces with the length of 5 cm. Among them forty pieces of rib bones with similar qualities were again selected. For the experimental group 1, the thickness of cortical part was measured and 20 pieces of rib bones with the mean thickness of 1.0mm were selected for implant placement. For the experimental group 2, the cortical parts of the remaining 20 pieces of rib bones were totally removed and then implants were placed on the pure cancellous bone according to the surgical manual. After placement of all implants, the implant stability quotient(ISQ) was measured by three times, and its statistical analysis was done. Results: There are statistically significant differences in ISQ values among 4 different kinds of Avana system implants in the experimental group 2. For the experimental group 1, Avana system implants showed significantly different ISQ values, but when differences in the thickness of cortical parts were statistically considered, did not show any significant differences in ISQ values. Among Oneplant system implants, there are no significant differences in ISQ values for the experimental group 2 as well as for the experimental group 1. Conclusion: Within the limits of this study, bone quality and implant design have some influences on the primary stability of implants. Especially in the bone of poor quality, tapered shape of implants are more favorable for the primary stability of implants.

Incidence and Clinical Features of Urethral Injuries with Pelvic Fractures in Males: A 6-Year Retrospective Cohort Study at a Single Institution in South Korea

  • Sun, Hyun Woo;Kim, Hohyun;Jeon, Chang Ho;Jang, Jae Hoon;Kim, Gil Hwan;Park, Chan Ik;Park, Sung Jin;Kim, Jae Hun;Yeom, Seok Ran
    • Journal of Trauma and Injury
    • /
    • v.34 no.2
    • /
    • pp.98-104
    • /
    • 2021
  • Purpose: Severe pelvic fractures are associated with genitourinary injuries, but the relationship between pelvic trauma and concomitant urethral injuries has yet to be elucidated. This study evaluated the incidence, mechanism, site, and extent of urethral injuries in male patients with pelvic fractures. Methods: A retrospective cohort study was performed involving patients with urethral injuries accompanying pelvic fractures who visited Pusan National University Hospital from January 1, 2014 to December 31, 2019. Demographics, mechanisms of injury, clinical features of the urethral injuries, concomitant bladder injuries, methods of management, and the configuration of the pelvic fractures were analyzed. Results: The final study population included 24 patients. The overall incidence of urethral injury with pelvic fracture was 2.6%, with the most common mechanism of urethral injury being traffic accidents (62.5%). Complete urethral disruption (16/24, 66.7%) was more common than partial urethral injuries (8/24, 33.3%), and unstable pelvic fractures were the most common type of pelvic fracture observed (70.8%). There was no definitive relationship between the extent of urethral injury and pelvic ring stability. Conclusions: The present study provides a 6-year retrospective review characterizing the incidence, mechanism, and clinical features of urethral injury-associated pelvic fractures. This study suggests that the possibility of urethral injury must be considered, especially in unstable pelvic fracture patients, and that treatment should be chosen based on the clinical findings.

Remote digital monitoring during the retention phase of orthodontic treatment: A prospective feasibility study

  • Sangalli, Linda;Savoldi, Fabio;Dalessandri, Domenico;Visconti, Luca;Massetti, Francesca;Bonetti, Stefano
    • The korean journal of orthodontics
    • /
    • v.52 no.2
    • /
    • pp.123-130
    • /
    • 2022
  • Objective: To evaluate if a remote digital monitoring system added at the end of orthodontic treatment could positively influence the retention phase by reducing the occurrence of misfit of removable appliances, number of emergency appointments (EA), and orthodontic relapse. Methods: Twenty-seven patients who completed active orthodontic treatment were divided into the study and control groups. In addition to the standard chairside follow-up appointments at month 1 (T1), month 3 (T2), month 6 (T3), the study group patients were monitored using Dental Monitoring® with monthly intra-oral scans. Occurrence of misfit of removable retainers, number of EAs, and intercanine width change were recorded for both groups. Differences in EAs and retainer fit were assessed using the chi-square test. Intra-group and inter-group differences in the intercanine width were assessed with Friedman test and Mann-Whitney U test, respectively (α = 0.05). Results: The study group showed a significantly lower occurrence of misfit of removable retainers (p = 0.027) compared to the control group. No significant inter- and intra-group difference was found in the EAs and intercanine width change at each time-point. Conclusions: Integrating remote monitoring systems, such as Dental Monitoring®, to the retention phase of the orthodontic treatment may lower the occurrence of misfit of removable retainers. However, a small sample size and a short observation period limit the strength of this evidence. These preliminary results tentatively suggest that remote monitoring technologies may be beneficial, especially during the COVID-19 pandemic, when the regularity of in-office visits might be disrupted.