Purpose : The aim of this study is the assessment of the clinical outcomes after percutanous pinning of unstable two-parts fracture of surgical neck in humerus. Materials and Methods: This study was based on thirteen cases of non-comminuted unstable surgical neck fracture of humerus among 19 cases, which followed-up more than one year. Follow-up averaged 29 months. We treated with percutaneous pinning techniques and assessed clinical outcomes. Functional evaluation was performed using the standard method of research committee of American Shoulder and Elbow Surgeons(ASES). Results: Last follow-up ROM of shoulder joint were 142 degrees of forward elevation, 57 degrees of external rotation, 72 degrees of external rotation in 90 degrees abduction, and T8 of internal rotation. Pain scale was l(range : 0∼3). ASES scores was 86.2(range : 63.3~98.3). Patient satisfaction based on ASES were excellent in 6 cases, good in 5 cases, fair in 1 case, poor in 1 case. A case of fair result was caused by limitation of motion in shoulder joint and poor case was paraplegia patient after traffic accident. Conclusion : Percutaneous pinning is recommended for non-comminuted unstable fracture of surgical neck in humerus.
Kim, Doo Sup;Yoon, Yeo Seung;Kang, Sang Kyu;Jin, Han Bin;Lee, Dong Woo
Clinics in Shoulder and Elbow
/
v.20
no.2
/
pp.90-94
/
2017
Background: Proximal humerus fracture is considered to be the third most common fracture for patients aged 65 years or older. Conservative treatment has been known to treat most of humerus fracture. However, fractures with severe displacement or dislocation may require surgical treatment. Intramedullary fibular allograft with a locking plate is frequently used in patients accompanying medial metaphyseal disruption. In this study, author intends to evaluate clinical and imaging results based on patients who underwent surgical treatment using fibular allograft with a locking plate. Methods: This study is conducted prospectively at Wonju Severance Christian Hospital, targeting patients who previously underwent surgical treatment using open reduction and intramedullary fibular allograft with a locking plate between 2011 and 2015. A total of 26 patients were evaluated on the following: postoperational clinical assessment measuring Constant score, American Shoulder and Elbow Society (ASES) score, and the Disabilities of the Arm, Shoulder and Hand (DASH) score. Postoperational imaging assessments are evaluated via measuring the neck-shaft angle. The study subject were Neer classification type 3, 4 proximal humerus fracture cases with disrupted medial hinge and having cortical comminution in the region of the surgical neck. Results: The average period of progression was 22.5 months, and the average age of patients was 72.6 years. At the final follow-up, the average Constant, average ASES, and average DASH scores were 80.1, 78.5, and 20.6 respectively. The average neck-shaft angle was $127.5^{\circ}$. Conclusions: In conclusion, fibular allograft augmentation with a locking plate showed satisfying results in both clinical and imaging studies.
Purpose: to determine the results after open intramedullary nailing and tension band suture technique in proximal humerus fracture for improving the stability and decreasing the complications. Materials and Method: Authors reviewed 27 patients treated by open intramedullary nailing and tension band suture technique. Mean follow-up period was 39 months (24-59months). Surgical neck fracture were 6 cases, surgical neck fracture with shaft fracture were 3 cases, three part fracture with greater tuberosity fracture were 17 cases, four part fracture was 1 case and fracture and dislocation were 2 cases Results: We got the bony union in 26 cases. Average pain scale was 1 point (0-6), Neer score was 86 point(45-99) and ASES score was 85 point(40-100). We separate all cases in two groups based on age (65 years), L-spine t-score (-2.5) and Neer classification (2 and 3 part). There is no significance in pain scale, Neer score and ASES score between each group. Conclusion: As a method of surgical treatment on severe proximal humeral fractures, we recommend intramedullary nailing and tension band suture technique and it may have particular advantages in early exercise and satisfactory functional outcome.
Background: The Boileau classification distinguishes three surgical neck fracture patterns: types A, B, and C. However, the reproducibility of this classification on plain radiographs is unclear. Therefore, we questioned what the interobserver agreement and accuracy of displaced surgical neck fracture patterns is categorized according to the modified Boileau classification. Does the reliability to recognize these fracture patterns differ between orthopedic residents and attending surgeons? Methods: This interobserver study consisted of a randomly retrieved series of 30 plain radiographs representing clinical practice in a level 1 and a level 2 trauma center. Radiographs were included from patients (≥18 years) who sustained an isolated displaced surgical neck fracture if they were taken ≤1 week after initial injury. A ground truth was established by consensus among three senior orthopedic surgeons. All images were assessed by 17 orthopedic residents and 17 attending orthopedic trauma surgeons. Results: Agreement for the modified Boileau classification was fair (κ=0.37; 95% confidence interval [CI], 0.36-0.38) with an accuracy of 62% (95% CI, 57%-66%). Comparison of interobserver variability between residents and attending surgeons revealed a significant but clinically irrelevant difference in favor of attending surgeons (0.34 vs. 0.39, respectively, Δκ=0.05, 95% CI, 0.02-0.07). Conclusions: The modified Boileau classification yields a low interobserver agreement with an unsatisfactory accuracy in a panel of orthopedic residents and attending surgeons. This supports the hypothesis that surgical neck fractures are challenging to categorize and that this classification should not be used to determine prognosis if only plain radiographs are available.
Park, Kyoung-Jin;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Keum, Sang-Wook;Kil, Kyoung-Min;Lim, Chae-Wook;Park, Sang-Jun
Clinics in Shoulder and Elbow
/
v.17
no.3
/
pp.134-137
/
2014
To report the fracture of proximal humerus in the lateral anchor site after suture bridge repair. A 57-year-old female patient with shoulder pain on the right-side was admitted through the emergency room following a car accident. Seven weeks before the accident, the patient had undergone surgery at a different hospital for the repair of supraspinatus tendon rupture on the right-side via suture bridge technique. Humerus surgical neck fracture was confirmed by X-ray, and proximal humerus fracture at the anchor site was confirmed by magnetic resonance imaging. Following 7 months of conservative treatment resulted in satisfactory bone union and motion of the shoulder joint. We report the need of close observation during and after the arthroscopic repair of the rotator cuff in patients with osteoporosis.
Purpose: This study is to analyze the result and complications of internal fixation with T-plate for two-part fracture of the neck of the humerus. Materials and Methods: The clinical results of fourteen patients who had been performed with this method mentioned above were reviewed. Their average age was 49.6. Postoperative mean follow up period was 24.1 months. Radiological evaluation was done by Kronberg's and shoulder function by Neer's. Results: By Kronberg evaluation, nine cases were good, two cases acceptable and three cases poor. By Neer's, mean score of shoulder function was 77.6 and 4 cases were excellent, one satisfactory, five unsatisfactory and four failure. The complications were the sfiff shoulder, loss of reduction and avascular necrosis of humeral head. Conclusion: In this study, there were differences according to the age. And we obtained an unsatisfactory result in patients over 50 years old. We consider that in patients over 50 years old, the differences were due to the muscle weakness through wide surgical approaches, postoperative implant loosening or the stiffness caused by poor rehabilitation.
Purpose: Evaluate the clinical results of humerus neck nonunion treated with Polarus intramedullary nail. Materials and Methods: 8 patients who underwent surgery for nonunion of humerus surgical neck fracture were included. All patients were female, the average age was 65 years. 5 out the total 8 cases initially received surgery, open reduction and internal fixation with metal plate in 1 case, Ender nail insertion in 2 cases, external fixator in 1 case and closed reduction and percutaneous pinning in 1 case. The other 3 non union cases initial received conservative managemnent. The average period of nonunion was 9 months in the operated group and 6.2 months in the conservative group. All 8 cases received closed reduction with intrameedullary Polarus nail and auto iliac bone graft. Union was confirmed radiologically, and functional evaluation was done with the UCLA functional criteria. Results: All 8 cases showed union on radiologic evaluation. Average time to union was 3.5 months, average follow up period was 27 months. Average UCLA shoulder evaluation score was 7.6 points preoperatively which improved to 26.3 points after surgery. Active shoulder flexion was 40.7 degrees preoperatiely which increased to 104 degrees after surgery. Shoulder abduction improved from 32.9 degrees preoperatively to 96.3 degrees after surgery. UCLA functional criteria was good in 5 cases and fair in 3 cases, which no poor cases. Conclusion: Polarus IM nailing and AIBG is a useful method for treating nonunion of humerus neck fracture with improvement in union and function.
The present study aimed to obtain basic knowledge of a customized artificial joint based on the convergence research of Digital Imaging and Communications in Medicine(DICOM) and 5-axis machining technology. In the case of the research method, three-dimensional modeling was generated based on the medical image of the humerus bone, and the shape was machined using a chemical wood material. Then, the anatomical characteristics and the modeling machining computation times were compared. The results showed that the Stereolithography (STL) modeling required twice more time for semi-finishing and 10 times more time for finishing compared to the Initial Graphics Exchange Specification(IGES) modeling. For the 5-axis machining humerus bone, the anatomical structures of the anatomic neck, greater tubercle, lesser tubercle, and intertubercular groove were similar to those in the three-dimensional medical image. In the future, the convergence machining technology, where 5-axis machining of various structures(e.g., the surgical neck undercut of the humerus bone) is performed as described above, can be efficiently applied to the manufacture of a customized joint that pursues the precise model of a human body.
Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.
Proximal humerus fracture can be defined as a fracture that occurs in the surgical neck or proximal part of the humerus. Despite the appropriate treatment, however, various complications and sequelae can occur, and the treatment is quite difficult often requiring surgical treatment, such as a shoulder replacement. The classification of sequelae after a proximal humerus fracture is most commonly used by Boileau and can be divided into two categories and four types. Category I is an intracapsular impacted fracture that is not accompanied by important distortions between the tuberosities and humeral head. An anatomic prosthesis can be used without greater tuberosity osteotomy. In category I, there are type 1 with cephalic collapse or necrosis with minimal tuberosity malunion and type 2 related to locked dislocation or fracture-dislocation. Category II is an extracapsular dis-impacted fracture with gross distortion between the tuberosities and the humeral head. To perform an anatomic prosthesis, a tuberosity osteotomy should be performed. In category II, there are type 3 with nonunion of the surgical neck and type 4 with severe tuberosity malunion. In type 1, non-constrained arthroplasty (NCA) without a tuberosity osteotomy should be considered as a treatment. On the other hand, reverse shoulder arthroplasty (RSA) should be considered if types 1C or 1D accompanied by valgus or varus deformity or severe fatty degeneration of the rotator cuff. In general, the results are satisfactory when NCA is performed in type 2 sequelae. On the other hand, RSA can be considered as an option when there is no bony defect of the glenoid and a defect of the rotator cuff is accompanied. In type 3, it would be effective to perform internal fixation with a bone wedge graft rather than shoulder replacement arthroplasty. Recent reports on the results of RSA are also increasing. On the other hand, recent reports suggest that good results are obtained with RSA in type 3. In type 4, RSA should be considered as a first option.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.