• Title/Summary/Keyword: Surgical mesh

Search Result 75, Processing Time 0.035 seconds

A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

  • Choi, Tae Joon;Burm, Jin Sik;Yang, Won Yong;Kang, Sang Yoon
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.84-87
    • /
    • 2016
  • Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

Anterior Decompression and Internal Fixation with Anterior Instrument and Surgical Titanium Mesh in Thoracolumbar Unstable Spine Injuries (Long-term Follow-up Results) (흉·요추 불안정성 척추 손상 환자에서 전방 감압술과 전방기기 및 Surgical Titanium Mesh를 이용한 내고정술 (장기적 추적 검사 결과))

  • Park, Hwan Min;Lee, Seung Myung;Cho, Ha Young;Shin, Ho;Jeong, Seong Heon;Song, Jin Kyu;Jang, Seok Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.58-65
    • /
    • 2000
  • Objective : Thoracolumbar junction is second most common level of injury next to cervical spine. The object of this study is to study the usefulness of surgical titanium mesh instead of bone graft, as well as to evaluate the correction of spinal deformity and safety of early ambulation in patients with injury at thoracolumbar junction. Patients and Methods : This review included 51 patients who were operated from July 1994 to December 1997. The injured spine is considered to be unstable, if it shows involvement of two or more columns, translatory displacement more than 3.5mm, decrease more than 35% in height of vertebral body and progression of malalignment in serial X-ray. The decision to operate was determined by (1) compression of spinal cord or cauda eguina, (2) unstable fracture, (3) malalignment and (4) fracture dislocation. The procedure consisted of anterior decompression through corpectomy and internal fixation with anterior instrument and surgical titanium mesh which was impacted with gathered bone chip from corpectomy. Results : Fifty-one patients were followed up for at least 12 months. The main causes of injury were fall and vehicle accident. The twelfth thoracic and the first and the second lumbar vertebrae were frequently involved. Complete neural decompression was possible under direct vision in all cases. Kyphotic angulation occurred in a patient. Radiologic evaluation showed correction of deformity and no distortion or loosening of surgical titanium mesh with satisfactory fixation postoperatively. Conclusions : We could obtain neurological improvement, relief of pain, immediate stabilization and early return to normal activities postoperatively. Based on these results, authors recommend anterior decompression and internal fixation with surgical titanium mesh in thoracolumbar unstable spine injuries.

  • PDF

Is Titanium Mesh Cage Safe in Surgical Management of Pyogenic Spondylitis?

  • Heo, Won;Kang, Dong-Ho;Park, Kyung-Bum;Hwang, Soo-Hyun;Park, In-Sung;Han, Jong-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.4
    • /
    • pp.357-362
    • /
    • 2011
  • Objective : To report our experience with pyogenic spondylitis treated with anterior radical debridement and insertion of a titanium mesh cage and to demonstrate the effectiveness and safety of the use of a titanium mesh cage in the surgical management of pyogenic spondylitis. Methods : We retrospectively analyzed the clinical characteristics of 19 patients who underwent surgical treatment in our department between January 2004 and December 2008. The average follow-up period was 11.16 months (range, 6-64 months). We evaluated risk factors, cultured organisms, lab data, clinical outcomes, and radiographic results. Surgical techniques for patients with pyogenic spondylitis were anterior radical debridement and reconstruction with titanium mesh cage insertion and screw fixation. All patients received intravenous antibiotics for at least 6 weeks postoperatively, and some patients received oral antibiotics. Results : The infections resolved in all of the patients as noted by normalization of their erythrocyte sedimentation rates and C-reactive protein levels. The mean pain score on a Visual Analog Scale was 7.8 (range, 4-10) before surgery and 2.4 (range, 1-5) after surgery. The Frankel grade was improved by one grade in seven patients. After surgery, the average difference of the angle was improved about $6.96^{\circ}$ in all patients. At the last follow-up, the mean loss of correction was $4.86^{\circ}$. Conclusion : Anterior radical debridement followed by the placement of instrumentation with a titanium mesh cage may be a safe and effective treatment for selected patients with pyogenic spondylitis. This surgical therapy does not lead to recurrent pyogenic spondylitis.

3D Simulation of Dental Implant Surgery Using Surgical Guide Stents (식립 보조도구를 이용한 3D 치아 임플란트 시술 시뮬레이션)

  • Park, Hyung-Wook;Kim, Myong-Soo;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.3
    • /
    • pp.216-226
    • /
    • 2011
  • Surgeon dentists usually rely on their experiential judgments from patients' oral plaster casts and medical images to determine the positional and directional information of implant fixtures and to perform drilling tasks during dental implant surgical operations. This approach, however, may cause some errors and deteriorate the quality of dental implants. Computer-aided methods have been introduced as supportive tools to alleviate the shortcomings of the conventional approach. In this paper, we present an approach of 3D dental implant simulation which can provide the realistic and immersive experience of dental implant information. The dental implant information is primarily composed of several kinds of 3D mesh models obtained as follows. Firstly, we construct 3D mesh models of jawbones, teeth and nerve curves from the patient's dental images using software $Mimics^{TM}$. Secondly, we construct 3D mesh models of gingival regions from the patient's oral impression using a reverse engineering technique. Thirdly, we select suitable types of implant fixtures from fixture database and determine the positions and directions of the fixtures by using the 3D mesh models and the dental images with software $Simplant^{TM}$. Fourthly, from the geometric and/or directional information of the jawbones, the gingival regions, the teeth and the fixtures, we construct the 3D models of surgical guide stents which are crucial to perform the drilling operations with ease and accuracy. In the application phase, the dental implant information is combined with the tangible interface device to accomplish 3D dental implant simulation. The user can see and touch the 3D models related with dental implant surgery. Furthermore, the user can experience drilling paths to make holes where fixtures are implanted. A preliminary user study shows that the presented approach can be used to provide dental students with good educational contents. With future work, we expect that it can be utilized for clinical studies of dental implant surgery.

Surgical Resection and Polypropylene Mesh Reconstruction for Canine Chest Wall Soft Tissue Sarcoma

  • Youngsoo Hong;Youngrok Song;Woojin Song;Myung-Chul Kim;Joo-Myoung Lee;Hyunjung Park;Jiwhan Moon;Jongtae Cheong
    • Journal of Veterinary Clinics
    • /
    • v.41 no.1
    • /
    • pp.24-29
    • /
    • 2024
  • A 6-year-old spayed female French Bulldog presented with a left-sided chest wall tumor. Physical examination revealed that the tumor was firmly adhered to the chest wall. A preoperative punch biopsy of the tumor revealed a grade 2 soft tissue sarcoma (STS). On computed tomography, the tumor's dimensions were assessed as 6.5 × 5.7 × 3.5 cm, and it exhibited invasiveness near the tissue surrounding the ninth rib. The tumor size was large in comparison to the dog's chest wall area. Hence, if the traditional wide-margin resection surgery were to be performed, primary wound closure seemed impractical and could potentially result in respiratory function complications. Therefore, considering the extent of tumor invasion and grade, deep margins were established to include the removal of the eighth to tenth ribs, and a 1-cm lateral margin was designated to enable primary wound closure. To reconstruct the chest wall, polypropylene mesh was attached to the adjacent ribs and the remaining muscles were sutured and covered over the mesh. The dog exhibited a rapid recovery beginning the day after the operation. Postoperative biopsy confirmed that the tumor was a grade 2 STS, and the surgical margins were evaluated as incomplete. The owner chose to pursue follow-up observation instead of chemotherapy. In this study, the surgical approach was chosen based on the importance of functional recovery after surgery. Recent research indicates that the tumor grade is more critical for postoperative prognosis than the extent of surgical margins when removing an STS.

Successful management of absent sternum in an infant using porcine acellular dermal matrix

  • Semlacher, Roy Alfred;Nuri, Muhammand A.K.
    • Archives of Plastic Surgery
    • /
    • v.46 no.5
    • /
    • pp.470-474
    • /
    • 2019
  • Congenital absent sternum is a rare birth defect that requires early intervention for optimal long-term outcomes. Descriptions of the repair of absent sternum are limited to case reports, and no preferred method for management has been described. Herein, we describe the use of porcine acellular dermal matrix to reconstruct the sternum of an infant with sternal infection following attempted repair using synthetic mesh. The patient was a full-term male with trisomy 21, agenesis of corpus callosum, ventricular septal defect, patent ductus arteriosus, right-sided aortic arch, and congenital absence of sternum with no sternal bars. Following removal of the infected synthetic mesh, negative pressure wound therapy with instillation was used to manage the open wound and provide direct antibiotic therapy. When blood C-reactive protein levels declined to ${\leq}2mg/L$, the sternum was reconstructed using porcine acellular dermal matrix. At 21 months postoperative, the patient demonstrated no respiratory issues. Physical examination and computed tomography imaging identified good approximation of the clavicular heads and sternal cleft and forward curvature of the ribs. This case illustrates the benefits of negative pressure wound therapy and acellular dermal matrix for the reconstruction of absent sternum in the context of infected sternal surgical site previously repaired with synthetic mesh.

Single-Stage Reconstruction with Titanium Mesh for Compound Comminuted Depressed Skull Fracture

  • Eom, Ki Seong
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.631-639
    • /
    • 2020
  • Objective : Traditionally, staged surgery has been preferred in the treatment of compound comminuted depressed fracture (FCCD) after traumatic brain injury (TBI) and involves the removal of primarily damaged bone and subsequent cranioplasty. The main reason for delayed cranioplasty was to reduce the risk of infection-related complications. Here, the author performed immediate reconstruction using a titanium mesh in consecutive patients with FCCD after TBI, reported the surgical results, and reviewed previous studies. Methods : Nineteen consecutive patients who underwent single-stage reconstruction with titanium mesh for FCCD of the skull from April 2014 to June 2018 were retrospectively analyzed. The demographic and radiological characteristics of the patients with FCCD were investigated. The characteristics associated with surgery and outcome were also evaluated. Results : The frequency of TBI in men (94.7%) was significantly higher than that in women. Most FCCDs (73.7%) occurred during work, the rest were caused by traffic accidents. The mean interval between TBI and surgery was 7.0±3.9 hours. The median Glasgow coma scale score was 15 (range, 8-15) at admission and 15 (range, 10-15) at discharge. FCCD was frequently located in the frontal (57.9%) and parietal (31.6%) bones than in other regions. Of the patients with FCCDs in the frontal bone, 62.5% had paranasal sinus injury. There were five patients with fractures of orbital bone, and they were easily reconstructed using titanium mesh. These patients were cosmetically satisfied. Postoperatively, antibiotics were used for an average of 12.6 days. The mean hospital stay was 17.6±7.5 days (range, 8-33). There was no postoperative seizure or complications, such as infection. Conclusion : Immediate bony fragments replacement and reconstruction with reconstruction titanium mesh for FCCD did not increase infectious sequelae, even though FCCD involved sinus. This suggests that immediate single-stage reconstruction with titanium mesh for FCCD is a suitable surgical option with potential benefits in terms of cost-effectiveness, safety, and cosmetic and psychological outcomes.

Cranioplasty and temporal hollowing correction with a three-dimensional printed bioresorbable mesh and double vertical suture anchor muscle sling: a case report

  • Choi, Jae Hyeok;Roh, Tai Suk;Lee, Won Jai;Baek, Wooyeol
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.4
    • /
    • pp.178-182
    • /
    • 2022
  • Postoperative temporal hollowing is a common complication of craniotomy. Damage and repositioning of the temporalis muscle can lead to a depression in the temporal side of the skull with inferior bulging, worsening aesthetic outcomes. We report a case of cranioplasty with three-dimensional (3D) printed mesh involving an additional correction using a temporalis muscle sling to help address this problem. A 3D-printed bioabsorbable mesh was prepared based on preoperative facial computed tomography, and was fixed to the hollowed area for tissue augmentation. The temporalis muscle was elevated and fanned out to its original position, and a sling was attached to a screw that was fixed to the mesh. For reinforcement, an additional sling was attached to another screw fixed to the mesh 2-3 cm vertically above the first screw. Aesthetic results were confirmed immediately after surgery and later during outpatient follow-up. Both depression and lateral bulging were resolved, and there was no delayed drooping of the temporalis muscle on 6-month follow-up. There were no complications, and the patient was satisfied with the appearance. This is a simple yet effective technique with a low risk of complications, and should be considered for postoperative temporal hollowing patients, especially those with severe lateral bulging.

A Clinical Analysis of Surgical Treatment for Spontaneous Spinal Infection

  • Lee, Dong-Geun;Park, Kyung-Bum;Kang, Dong-Ho;Hwang, Soo-Hyun;Jung, Jin-Myung;Han, Jong-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.317-325
    • /
    • 2007
  • Objective : The purpose of the study was to determine the clinical effects of anterior radical debridement on a series of patients with spontaneous spinal infection. Methods : We retrospectively analyzed the clinical characteristics of 32 patients who underwent surgical treatment from January 2000 to December 2005 in our department. The average follow-up Period was 33.4 months (range, 6 to 87 months). Thirty-two patients presented with the following : 23 cases with pyogenic spondylitis, eight with tuberculous spondylitis and one with fungal spondylitis. The indications for surgery were intractable pain, failure of medical management, neurological impairment with or without an associated abscess, vertebral destruction causing spinal instability and/or segmental kyphosis. Results : The study included 15 (46.9%) males and 17 (53.1%) females ranging in age from 26 to 75 years (mean, 53.1 years). Diabetes mellitus (DM) and pulmonary Tbc were the most common predisposing factors for pyogenic spondylitis and tuberculous spondylitis. Staphylococcus aureus (13%) was the main organism isolated. The most prevalent location was the lumbar spine (75%). Changes in the pain score, Frankel's classification, and laboratory parameters demonstrated a significant clinical improvement in all patients. However, there were recurrent infections in two patients with tuberculous spondylitis and inappropriate debridement and intolerance of medication and noncompliance. Autologous rib, iliac bone and allograft(fibular) were performed in most patients. However, 10 patients were grafted using a titanium mesh cage after anterior radical debridement. There were no recurrent infections in the 10 cases using the mesh cage with radical debridement. Conclusion : The findings of this study indicate that surgery based on appropriate surgical indications is effective for the control of spinal infection and prevention of recurrence with anterior radical debridement, proper drug use and abscess drainage.

Preliminary Surgical Result of Cervical Spine Reconstruction with a Dynamic Plate and Titanium Mesh Cage

  • Chung, Dae-Yeong;Cho, Dae-Chul;Lee, Sun-Ho;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.111-117
    • /
    • 2007
  • Objective : The objective of this study was to validate the effects of a titanium mesh cage and dynamic plating in anterior cervical stabilization after corpectomy. Methods : A retrospective study was performed on 31 consecutive patients, who underwent anterior cervical reconstruction with a titanium mesh cage and dynamic plating, from March 2004 to February 2006. Twenty-four patients had 1-level and 7 had 2-level corpectomies. Ten patients underwent surgery with a cage of 10-mm diameter and 21 with 13-mm diameter. Neurological status and outcomes were assessed according to Odom's criteria. Sagittal angle, coronal angle, settling ratio, sagittal displacement, and cervical lordosis were used to evaluate the radiological outcomes. Results : In overall, 26 [83.9%] of 31 showed excellent or good outcomes. Thirteen percent [4 cases] of the patients developed surgical complications, such as hoarseness, transient dysphagia, or nerve root palsy. Seven [22.6%] patients had reconstruction failure:5 [20.8%] in the 1-level corpectomy group and 2 [28.5%] in the 2-level corpectomy group. Revisions were required in 2 patients with plate pullout due to significant instability. However, none of 5 patients who demonstrated cage displacement or screw pullout, underwent a revision. Radiographs revealed bony consolidation in 96.3% of the patients, including 6 patients with implantation failure during the follow-up period. Conclusion : Based on our preliminary results, the titanium mesh cage and dynamic plating was effective for cervical reconstruction after corpectomy. The anterior cervical reconstruction performed with dynamic plates is considered to reduce stress shielding and greater graft compression that is afforded by the unique plate design.