• 제목/요약/키워드: Surgical material

검색결과 725건 처리시간 0.026초

임프란트 수술 및 보철물에 따른 합병증 연구 (Study about the complications associated with implant surgery and prosthetic treatment)

  • 이지영;김영균;윤필영;배지현;김재승
    • 대한치과의사협회지
    • /
    • 제47권9호
    • /
    • pp.585-595
    • /
    • 2009
  • Purpose : The aim of this study was to compare surgical complications between simple implant placement and implant placement combined with complicated surgical procedures. We also evaluated prosthetic complications according to the specific types of prosthesis. Material and Method : A retrospective analysis of dental chart of patients who was performed implant therapy during the period from June 2003 to December 2005 was carried out. This study was performed on 408 patients (208 male, 200 female). In addition, 1671 implants were performed. Based on their medical record and radiographs, the authors evaluated surgical and prosthetic complications, surgical procedures accompanied at the time of implant, risk factors of implant failure etc. Result : Surgical complications were developed on 358 implants(21.4% on total placed implants) and wound dehiscence was most prevalent complication. On maxillary posterior area, surgical complications developed more frequently on implants with major surgery and showed a significant difference. And complication rate of implants accompanied with GBR was higher than that of simple implants placement and also showed significant difference. The implant supported prosthesis showed no statistical difference in the occurrence of complications according to the types of prosthesis, and food retention was the most common post-prosthetic complication. Also we speculated that length and width of implant showed significant correlation to the failure of implant primary osseointegration. Conclusion : Based on the result, clinician should provide more careful maintenance for patients with implant placement accompanied by complicated surgical procedure. And periodic maintenance for the patient is requested for long-term survival of implant therapy.

  • PDF

Accidental injury of the inferior alveolar nerve due to the extrusion of calcium hydroxide in endodontic treatment: a case report

  • Shin, Yooseok;Roh, Byoung-Duck;Kim, Yemi;Kim, Taehyeon;Kim, Hyungjun
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.63-67
    • /
    • 2016
  • During clinical endodontic treatment, we often find radiopaque filling material beyond the root apex. Accidental extrusion of calcium hydroxide could cause the injury of inferior alveolar nerve, such as paresthesia or continuous inflammatory response. This case report presents the extrusion of calcium hydroxide and treatment procedures including surgical intervention. A 48 yr old female patient experienced Calcipex II extrusion in to the inferior alveolar canal on left mandibular area during endodontic treatment. After completion of endodontic treatment on left mandibular first molar, surgical intervention was planned under general anesthesia. After cortical bone osteotomy and debridement, neuroma resection and neurorrhaphy was performed, and prognosis was observed. But no improvement in sensory nerve was seen following surgical intervention after 20 mon. A clinician should be aware of extrusion of intracanal medicaments and the possibility of damage on inferior alveolar canal. Injectable type of calcium hydroxide should be applied with care for preventing nerve injury. The alternative delivery method such as lentulo spiral was suggested on the posterior mandibular molar.

Reconstruction of extended orbital floor fracture using an implantation method of gamma-shaped porous polyethylene

  • Hwang, Woosuk;Kim, Jin Woo
    • 대한두개안면성형외과학회지
    • /
    • 제20권3호
    • /
    • pp.164-169
    • /
    • 2019
  • Background: The conventional surgical method for reconstructing orbital floor fractures involves restoration of orbital continuity by covering an onlay with a thin material under the periorbital region. However, in large orbital floor fractures, the implant after inserting is often dislocated, leading to malposition. This study aimed to propose a novel implanting method and compare it with existing methods. Methods: Among patients who underwent surgery for large orbital floor fractures, 24 who underwent the conventional onlay implanting method were compared with 21 who underwent the novel ${\gamma}$ implanting method that two implant sheets were stacked and bent to resemble the shape of the Greek alphabet ${\gamma}$. When inserting a ${\gamma}$-shaped implant, the posterior ledge of the orbital floor was placed between the two sheets and the bottom sheet was impacted onto the posterior wall of the maxilla to play a fixative role while the top sheet was placed above the residual orbital floor to support orbital contents. Wilcoxon signed-rank test and Mann-Whitney U test were used for data analyses. Results: Compared to the conventional onlay method, the gamma method resulted in better restoration of orbital contents, better improvement of enophthalmos, and fewer revision surgeries. Conclusion: Achieving good surgical outcomes for extended orbital floor fractures is known to be difficult. However, better surgical outcomes could be obtained by using the novel implantation method of impacting a ${\gamma}$-shaped porous polyethylene posteriorly.

Computer-aided design/computer-aided manufacturing of hydroxyapatite scaffolds for bone reconstruction in jawbone atrophy: a systematic review and case report

  • Garagiola, Umberto;Grigolato, Roberto;Soldo, Rossano;Bacchini, Marco;Bassi, Gianluca;Roncucci, Rachele;De Nardi, Sandro
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.2.1-2.9
    • /
    • 2016
  • Background: We reviewed the biological and mechanical properties of porous hydroxyapatite (HA) compared to other synthetic materials. Computer-aided design/computer-aided manufacturing (CAD/CAM) was also evaluated to estimate its efficacy with clinical and radiological assessments. Method: A systematic search of the electronic literature database of the National Library of Medicine (PubMed-MEDLINE) was performed for articles published in English between January 1985 and September 2013. The inclusion criteria were (1) histological evaluation of the biocompatibility and osteoconductivity of porous HA in vivo and in vitro, (2) evaluation of the mechanical properties of HA in relation to its porosity, (3) comparison of the biological and mechanical properties between several biomaterials, and (4) clinical and radiological evaluation of the precision of CAD/CAM techniques. Results: HA had excellent osteoconductivity and biocompatibility in vitro and in vivo compared to other biomaterials. HA grafts are suitable for milling and finishing, depending on the design. In computed tomography, porous HA is a more resorbable and more osteoconductive material than dense HA; however, its strength decreases exponentially with an increase in porosity. Conclusions: Mechanical tests showed that HA scaffolds with pore diameters ranging from 400 to $1200{\mu}m$ had compressive moduli and strength within the range of the human craniofacial trabecular bone. In conclusion, using CAD/CAM techniques for preparing HA scaffolds may increase graft stability and reduce surgical operating time.

Retrospective analysis of 79 patients with orbital floor fracture: outcomes and patient-reported satisfaction

  • Senese, Olivier;Boutremans, Edward;Gossiaux, Caroline;Loeb, Isabelle;Dequanter, Didier
    • 대한두개안면성형외과학회지
    • /
    • 제19권2호
    • /
    • pp.108-113
    • /
    • 2018
  • Background: The aim of our retrospective study is to evaluate the management of isolated orbital floor fractures considering the clinical, functional and aesthetic results according to the surgical approach and the type of materials used. Methods: Retrospectively, clinical, radiological, surgical, and ophthalmological data from 79 patients were collected from January 2010 to December 2016. Furthermore, included patients were interrogated on functional and aesthetic satisfaction. Results: The main causes of trauma were physical aggression followed by accidents. The median time between trauma and surgery was 4 days. The most common surgical approaches were the subciliary and the transconjunctival ones. Alloplastic materials were used in 75 patients. In two patients, we used a combination of two grafts. Patients experienced minor immediate complications. On follow-ups, none of our patients suffered from ocular movement restrictions. Patients treated by subciliary approach had higher risk of retractile scaring compared to other surgical approaches. In our study, patients agreed to complete a questionnaire assessing functional and aesthetic outcomes with a high satisfaction score. No association between the implant material used and the results has been assessed. Conclusion: This study describes the results of orbital floor reconstructions. Despite a variety of materials used and surgical approaches performed, we believe that the transconjunctival approach is the most suitable option with a high satisfaction score.

제3D 병기 폐암의 수술성적 (Result of Surgical Treatment of Stage IIIB Lung Cancer)

  • 홍기표
    • Journal of Chest Surgery
    • /
    • 제33권2호
    • /
    • pp.173-178
    • /
    • 2000
  • Background: Though the surgical treatment of stage IIIB lung cancer is not generalized due to low complete remission rate high morbidity and mortality there are several reports on the improvement of long term survival after preoperative and postoperative adjuvant therapy. In this study we analyzed the prognostic factors affecting long term survival after surgical treatment of stage IIIB lung cancer Material and method: We analyzed the long term survival for age pathology invaded mediastinal organ n stage type of operation complete or incomplete resection and adjuvant therapy through a retrospective review of patients underwent surgical treatment. Result: From 1990 to 1998 56 patients(51/male 5/female0 with stage IIIB lung cancer were trated surgically. Forty two patients underwent radical resection and morbidity and mortality were 17% 12% respectively. The survival rate for overall patients and the radical resection group were 9% 12% respectively. In the radical resection group excluding explothoracotomy only(n=14) and the surgical mortality patients(n=5) the age the type of operation celly type resectability and N stage had no influence on the long term survival. The survival rate of radical resection group was significantly better than that of the explothoracotomy only group(p=0.04) The long term survival rate of postoperative combination therapy group was significantly better than chemotherapy or radiotherapy alone(p=0.04) Conclsion: Age type after surgical treatment of stage IIIB lung cancer. We conclude that combined modality of adjuvant treatment after radical resection of stage IIIB lung cancer seems to offer better long term survival in selective patients. The numbers of patients involved was small. Nevertheless these preliminary findings indicate questions that will need to be experienced further in larger studies.

  • PDF

가미의이인탕(加味薏苡仁湯)의 투염증작용(投炎症作用)에 대(對)한 실험적(實驗的) 연구(硏究) (STUDIES ON THE ANTI-INFLAMMATORY EFFECT OF THE KAMI EUI YEE IN TANG ON RAT)

  • 윤태여
    • 대한한방내과학회지
    • /
    • 제1권1호
    • /
    • pp.64-69
    • /
    • 1976
  • Kami Eui In Tang is being used as a treatment oral medicament on the appendicitis and peritonitis without surgical operation resulting good effect. The component of the medicament are as follow : Coix ma yuen, Paeonia moutan, Patrinia scabiosifolia, Rheum, Coreanum, Cory-dalis nakaii, Trichosanthes kirilowii, Lonicera japonica, Prunus persica, Tarxacum officinale, Author tried to make clear the ant inflammatory effect on rat paw which has become edema formation by carrageenin and detect the active ingredients by thin layer chromatography method. The material was extracted with three kind of solvent; distilled water, 50% ethyl alcohol, and ether which were immersed in material for 48 hours and concentrated to 10ml by evaporation of solvents. The result was as follow: 1. The anti-inflammatory effect of the sample material on the. edema formed at the rat paw was obviously clear. 2. Many spots of active ingredients were detected on the silica gel G plate spotted by ether extracted material than water one. 3. The good developing solvent was the mixture of $CHCl_3$ ; Acetone : Diethylamine (5:4:1).

  • PDF

The Vestibuloplasty Using Non-eugenol-based Non-zinc Oxide Oral Dressing Material

  • Ku, Jeong-Kui;Leem, Dae Ho
    • Journal of Korean Dental Science
    • /
    • 제14권1호
    • /
    • pp.46-50
    • /
    • 2021
  • This study describes a patient with insufficient vestibular depth who was operated with a vestibuloplasty using a non-eugenol-based non-zinc oxide oral dressing material. Partial thickness flap was elevated on recipient. After stabilization of apical positioned flap, the dressing material was applied on the recipient site with additional fixation by suture. The patient presented minimal discomfort such as in pain, food impaction and management of oral hygiene. Adequate vestibular depth without relapse was observed until 4 weeks after surgery. The vestibuloplasty with the oral dressing material may be an option for obtaining proper vestibular depth without complications.

Recent advances in the reconstruction of cranio-maxillofacial defects using computer-aided design/computer-aided manufacturing

  • Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.2.1-2.7
    • /
    • 2018
  • With the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology, it has been possible to reconstruct the cranio-maxillofacial defect with more accurate preoperative planning, precise patient-specific implants (PSIs), and shorter operation times. The manufacturing processes include subtractive manufacturing and additive manufacturing and should be selected in consideration of the material type, available technology, post-processing, accuracy, lead time, properties, and surface quality. Materials such as titanium, polyethylene, polyetheretherketone (PEEK), hydroxyapatite (HA), poly-DL-lactic acid (PDLLA), polylactide-co-glycolide acid (PLGA), and calcium phosphate are used. Design methods for the reconstruction of cranio-maxillofacial defects include the use of a pre-operative model printed with pre-operative data, printing a cutting guide or template after virtual surgery, a model after virtual surgery printed with reconstructed data using a mirror image, and manufacturing PSIs by directly obtaining PSI data after reconstruction using a mirror image. By selecting the appropriate design method, manufacturing process, and implant material according to the case, it is possible to obtain a more accurate surgical procedure, reduced operation time, the prevention of various complications that can occur using the traditional method, and predictive results compared to the traditional method.

Bowel Obstruction Due to Less-Digestible Pet Food with No Shadowing on Ultrasonography in a Small-Breed Puppy

  • Junyoung Kim;Jihye Choi;Junghee Yoon
    • 한국임상수의학회지
    • /
    • 제41권2호
    • /
    • pp.127-132
    • /
    • 2024
  • A 6-month-old intact female Bichon Frise dog weighing 0.9 kg presented with vomiting, anorexia, and lethargy persisting for 3 days. No remarkable abnormalities were detected on the history or physical examination. Laboratory findings were mostly normal, except for elevated levels of alkaline phosphatase (ALP) and blood urea nitrogen (BUN). Abdominal radiography revealed a fluid-dilated stomach and gas-dilated intestinal loops in the regional areas. Abdominal ultrasonography was performed to investigate the cause of gastrointestinal dilation, which revealed a rectangular, homogeneous, echogenic foreign material with no shadowing in the small intestine, causing mechanical obstruction. Upon further inquiry involving detailed re-take of history with the owner, a history of ingesting dog gum 4 days prior was identified. On surgical enterotomy, the hard pet food was identified and removed from the distal duodenum. Postoperatively, the patient's clinical signs showed complete improvement, with a return to normal appetite. The present case demonstrates that less-digestible, hard pet food, despite showing no shadowing on ultrasonography, can act as a foreign material, causing mechanical intestinal obstruction in a small-breed puppy. Furthermore, surgical removal of these materials is necessary in cases of intestinal obstruction.