• 제목/요약/키워드: Surgical Stent

검색결과 141건 처리시간 0.027초

A Review of the Techniques, Current Status and Learning Curves of Laparoscopic Bile Duct Exploration

  • Poh Benjamin Ruimin;Tan Siong San;Lee Lip Seng;Chiow Adrian Kah Heng
    • Journal of Digestive Cancer Research
    • /
    • 제5권1호
    • /
    • pp.37-43
    • /
    • 2017
  • Laparoscopic cholecystectomy is of one the most common general surgical operations performed today. Concomitant choledocholithiasis occurs in roughly 10-20% of patients with symptomatic gallstones. Laparoscopic bile duct exploration (LBDE) offers a single-stage minimally-invasive solution to the management of choledocholithiasis. LBDE may be performed either via the transcystic route or via laparoscopic choledochotomy. A number of strategies to improve success are available to the surgeon to help in the problem of complicated choledocholithiasis, these range from simple maneuvers to the use of laser or mechanical lithotriptors. With the advances in laparoscopic surgery, it is also possible to handle complex surgical conditions such as Mirizzi syndrome or recurrent pyogenic cholangitis laparoscopically, even though these have yet to be accepted as standard of care. Following laparoscopic choledochotomy, options for closure include: primary closure, closure over a T-tube, and closure over an endobiliary stent. T-tube placement has been associated with increased operating time and hospital length of stay compared to primary closure, with no significant differences in morbidity. Based on the available literature, LBDE appears comparable to ERCP with regards to procedural efficacy and morbidity. LBDE remains relevant to the general surgeon and is best viewed as being complementary to endoscopic therapy in the management of choledocholithiasis.

  • PDF

컴퓨터 시뮬레이션 기반의 외과용 스텐트를 이용한 임플란트 시술과 영상융합기술을 이용한 평가 (Implant surgery based on computer simulation surgical stent and the assessment with the image fusion technique)

  • 이지호;김성민;팽준영;김명진
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권5호
    • /
    • pp.402-407
    • /
    • 2010
  • Introduction: The planning of implant surgery is an important factor for the implant prosthesis. Stereolithographic (SLA) surgical stents based on a computer simulation are quite helpful for clinicians to perform the surgery as planned. Although many clinical and technical trials have been performed for computed tomography (CT)-guided implant stents to improve the surgical procedures and prosthetic treatment, there are still many problems to solve. We developed a system of a surgical guide based on 3 dimensional (3D) CT for implant therapy and achieved satisfactory results in the terms of planning and operation. Materials and Methods: Fifteen patients were selected and 30 implant fixtures were installed. The preoperative CT data for surgical planning were prepared after obtaining informed consent. Surgical planning was performed using the simulation program, Ondemend3D In2Guide. The stents were fabricated based on the simulation data containing information of the residual bone, the location of the nerve, and the expected design of the prostheses. After surgery with these customized stents, the accuracy and reproducibility of implant surgery were evaluated based on the computer simulation. The data of postoperative CT were used to confirm this system using the image fusion technique and compare the implant fixtures between the planned and implanted. Results: The mean error was 1.18 (${\pm}0.73$) mm at the occlusal center, 1.23 (${\pm}0.67$) mm at the apical center, and the axis error between the two fixtures was $3.25^{\circ}C$ (${\pm}3.00$). These stents showed superior accuracy in maxilla cases. The lateral side error at the apical center was significantly different from the error at the occlusal center but there were no significant differences between the premolars, 1st molars and 2nd molars. Conclusion: SLA surgical stents based on a computer simulation have the satisfactory accuracy and are expected to be useful for accurate planning and surgery if some errors can be improved.

Stent-Assisted Coil Trapping in a Manual Internal Carotid Artery Compression Test for the Treatment of a Fusiform Dissecting Aneurysm

  • Seung, Won-Bae;Kim, Jin-Wook;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권5호
    • /
    • pp.296-300
    • /
    • 2012
  • Internal carotid artery (ICA) trapping can be used for the treatment of giant intracranial aneurysms, blood blister-like aneurysms, and fusiform dissecting aneurysms. Fusiform dissecting aneurysms are challenging to treat surgically and endovascularly because of no definite neck and critical perforators. Surgical or endovascular trapping of the ICA with or without an extracranial-intracranial bypass has commonly been used as an effective method to treat these lesions, but balloon test occlusion (BTO) must be performed. Here, we report a case of a ruptured fusiform dissecting aneurysm of the distal ICA, which was successfully treated using an endovascular ICA trapping with a manual ICA compression test instead of BTO.

Endovascular Treatment of Blood Blister-Like Aneurysms Using Multiple Self-Expanding Stents

  • Kim, Young-Woo;Park, Ik-Seong;Baik, Min-Woo;Jo, Kwang-Wook
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권2호
    • /
    • pp.116-119
    • /
    • 2011
  • The surgical as well as endovascular treatment of blood-blister-like aneursysms (BBAs) is extremely difficult because of these pathological natures, such as small and the fragile necks. The optimal treatment of BBAs has remained uncertain. Stents are known to divert blood flow and induce thrombosis of intracranial aneurysms. We report 3 cases of successful obliteration of BBAs after multiple stents placement.

A Simple Surgical Guide for Horizontal Bone Graft: A Technical Note

  • Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권2호
    • /
    • pp.90-92
    • /
    • 2016
  • Horizontal bone defect in the anterior maxilla makes it difficult to place dental implant. The golden standard for bone augmentation is autogenous block bone graft. Tight contact with recipient site and rigid fixation are two key factors for successful block bone graft. Ramal bone graft has been the most reliable methods for dental implant field. However, the curvature of the alveolar ridge is different from ramal bone shape. Intraoperative trimming of ramal bone is cumbersome for surgeon. In this technical note, a simple way to design the ramal bone harvest using bone wax stent is reviewed.

Cystic Adventitial Disease of the Popliteal Artery: Resection and Repair with Autologous Vein Patch

  • Maeng, Young-Hee;Chang, Jee-Won;Kim, Sun-Hyung
    • Journal of Chest Surgery
    • /
    • 제44권3호
    • /
    • pp.266-268
    • /
    • 2011
  • Cystic adventitial disease is rare, but it is one of the well-recognized causes of non-atherosclerotic arterial stenosis or obstruction. Despite one of its most common symptoms being chronic intermittent claudication, it may be misdiagnosed as arterial embolism when presented with acute ischemic symptoms. Surgical resection is recommended because of recurrence or a low success rate with aspiration or endovascular stent. We performed resection and repair with autologous vein patch for cystic adventitial disease of the popliteal artery of a 57-year-old man presenting with pain, pallor, and paresthesia, without any postoperative complications or recurrence.

Extra-anatomic Bypass Grafting after Endovascular Embolization for the Treatment of Mycotic Aneurysm - 2 case reports -

  • Kim, Kwan-Wook;Kim, Jung-Hwan;Youn, Young-Nam
    • Journal of Chest Surgery
    • /
    • 제44권2호
    • /
    • pp.189-192
    • /
    • 2011
  • Mycotic aneurysm is a disease requiring immediate treatment because of the high risk of rupture. A difficult surgical approach, especially in the case of occurrence on the iliac artery, involving endovascular embolization and extra-anatomic bypass grafting, is known to be a suitable treatment. We performed extra-anatomic bypass grafting after endovascular embolization successfully in two patients. The postoperative computed tomography of both patients showed complete exclusion of the mycotic aneurysm.

갑상연골과 설골 골절을 동반한 후두외상 1례 (Laryngeal trauma with thyroid cartilage and hyoid bone frachture)

  • 강선묵;최환;정광윤;백승국
    • 대한기관식도과학회지
    • /
    • 제13권1호
    • /
    • pp.51-54
    • /
    • 2007
  • Laryngeal trauma is an uncommon injury but can be life-threatening event. So, early diagnosis is important for appropriate surgical management and better outcome. Because there have been some controversies about Initial airway management, appropriate diagnostic evaluation, operative indication and timing, operative technique, it is difficult to make a common management pathway in laryngeal trauma. A case of laryngeal trauma with thyroid cartilage and hyoid bone fracture is presented with a brief review of literature.

  • PDF

기관문합수술에서 PTFE(Polytetrafluoroethylene)를 이용한 협착방지에 대한 실험연구 (An Experimental Study for the Prevention of Postanastomotic Tracheal Stenosis using PTFE (Polytetrafluoroethylene) in Tracheal Surgery)

  • 이석열;이길노;고은석
    • 대한기관식도과학회지
    • /
    • 제8권1호
    • /
    • pp.22-28
    • /
    • 2002
  • Background and Objectives : The aim of the this study is to determine the efficacy of an external prosthesis made of ringed Polytetrafluoroethylene to prevent Postanastomotic stenosis after surgical correction of extensive tracheal defects in rabbits. Materials and Methods : Thirty rabbits were used, divided into two groups of 15 animals each. Group A rabbits underwent resection of six-ring segments of the cervical trachea and tracheal end-to-end anastomosis. The Procedure used in group B was similar to that used in group A. but the tracheal anastomosis was supported by an external ringed polytetrafluoroethylene prosthesis. After six months, rabbits were killed and tracheas were resected and then compared the postanastomotic tracheal stenosis using morphometry. Results : Anteroposterior diameter, transverse diameter, cross sectional area and intra luminal perimeter of trachea was greater in group B than group A. Also inflammatory changes of mucosa and submucosa were greater in group A than group B. Conclusion : A ringed PTFE as a external stent was effective to prevent tracheal stenosis resulting from the extensive tracheal resection and tracheal reconstruction in rabbits.

  • PDF

Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report

  • Noh, Kwantae;Choi, Woo-Jin;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.67-72
    • /
    • 2013
  • Traumatic defects are mostly accompanied by hard and soft tissue loss. This report describes the surgical and prosthetic treatment of a patient with post-traumatic mandibular defect. A split-thickness skin graft was performed prior to implant placement and prefabricated acrylic stent was placed to hold the graft in place. The esthetic and functional demands of the patient were fulfilled by implant-supported screw-retained fixed prosthesis using CAD-CAM technology.