• Title/Summary/Keyword: Surgical Stent

Search Result 141, Processing Time 0.03 seconds

Evaluation of the accuracy of two different surgical guides in dental implantology: stereolithography fabricated vs. positioning device fabricated surgical guides (제작방법에 따른 임플란트 수술 가이드의 정확성비교: stereolithography와 positioning device로 제작한 수술 가이드)

  • Kwon, Chang-Ryeol;Choi, Byung-Ho;Jeong, Seung-Mi;Joo, Sang-Dong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.271-278
    • /
    • 2012
  • Purpose: Recently implant surgical guides were used for accurate and atraumatic operation. In this study, the accuracy of two different types of surgical guides, positioning device fabricated and stereolithography fabricated surgical guides, were evaluated in four different types of tooth loss models. Materials and methods: Surgical guides were fabricated with stereolithography and positioning device respectively. Implants were placed on 40 models using the two different types of surgical guides. The fitness of the surgical guides was evaluated by measuring the gap between the surgical guide and the model. The accuracy of surgical guide was evaluated on a pre- and post-surgical CT image fusion. Results: The gap between the surgical guide and the model was $1.4{\pm}0.3mm$ and $0.4{\pm}0.3mm$ for the stereolithography and positioning device surgical guide, respectively. The stereolithography showed mesiodistal angular deviation of $3.9{\pm}1.6^{\circ}$, buccolingual angular deviation of $2.7{\pm}1.5^{\circ}$ and vertical deviation of $1.9{\pm}0.9mm$, whereas the positioning device showed mesiodistal angular deviation of $0.7{\pm}0.3^{\circ}$, buccolingual angular deviation of $0.3{\pm}0.2^{\circ}$ and vertical deviation of $0.4{\pm}0.2mm$. The differences were statistically significant between the two groups (P<.05). Conclusion: The laboratory fabricated surgical guides using a positioning device allow implant placement more accurately than the stereolithography surgical guides in dental clinic.

Surgical Experiences for Non-ST-segment Elevation Acute Coronary Syndrome (ST분절의 상승을 동반하지 않은 급성 관동맥 증후군의 수술 치험)

  • Yu Song-Hyeon;Lim Sang-Hyun;Chang Byung-Chul;Yoo Kyung-Jong;Hong You-Sun
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.754-758
    • /
    • 2006
  • Background: Surgical role for acute coronary syndrome has been reduced in recent years due to development of drug eluting stent. We evaluated the surgical results of acute coronary syndrome in our hospital. Material and Method: Between January 2001 and August 2005, 416 patients underwent coronary artery bypass grafting (CABG) under diagnosis of non-ST-elevation acute coronary syndrome (NSTE ACS). Mean age was $61.8{\pm}9.0$ years and 276 (66.3%) patients were male. 324 (77.9%) patients had triple vessel disease and 92 (22.1%) had left main disease at angiographic study. 236 (56.7%) patients had hypertension and 174 (41.8%) had diabetes mellitus. Conventional on-pump CABG was performed in 194 patients (46.6%) and off-pump CABG in 222 (53.4%). Total arterial revascularization with no touch technique was done in 97 patients (23.3%). The number of total distal anastomosis was 1,306 and the number per patient was $3.21{\pm}1.71$. Result: Surgical mortality rate was 1.0% (4 patients) and postoperative complication rate was 15.6% (65 patients). Graft patency was checked at mean $3.7{\pm}7.6$ months (from 1 to 37 months) postoperatively with multi-directional computed tomography in 152 patients. Left internal mammary artery was patent in 95.3%, right internal mammary artery in 98.1%, radial artery in 92.2% and saphenous vein in 89.0%. Conclusion: The surgical treatment of NSTE ACS showed relatively low mortality rate and good graft patency rate. Further study is needed to compare the long term results with drug eluting stent.

Surgical Treatment of the Descending Thoracic Aorta ; An analysis of 22 cases (하행 흉부 대동맥류의 외과적 치료; 22예의 분석)

  • 이홍섭;이선훈;윤영철;구본일;김창호
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.532-535
    • /
    • 1999
  • Background: The purpose of this study was to evaluate and analyze the surgical techniques and postoperative complications in patients undergoing operations for descending thoracic aortic aneurysms. Material and Method: The data of 22 major operations between March 1987 and August 1997 were retrospectively reviewed. Result: There were 18 men and 4 women with a mean age of 49 years (range 33 years to 82 years). The cause of the aneurysm was aortic dissection in 13 patients, atherosclerosis in 3, mycotic in 3, trauma in 2 and uncertain in 1. The operative techniques were resection and graft replacement in 16, axillofemoral bypass graft in 2, femorofemoral bypass graft in 2, exclusion, aneurysmorrhaphy in 1 and transfemoral stent insertion in 1. During the operation, 16 cases were performed under total aortic clamp. Among the 16 patients, femorofemoral bypass was used in 14 cases and previously made shunt in 2 cases. The mean total aortic clamp time was 91 minutes and the mean extracorporeal circulation time was 116 minutes. One death occurred in an excluded patient on the 52 postoperative day due to a rupture of the aneurysm. Postoperative complications were paraplegia in 1 case, acute renal failure in 1 case and acute respiratory failure in 1 case. Conclusion: Although surgical treatment of the descending thoracic aneurysm has many postoperative complications, good surgical results can be achieved with a proper patient selection and fine surgical techniques.

  • PDF

Deep vein thrombosis caused by malignant afferent loop obstruction

  • Kang, Eun Gyu;Kim, Chan;Lee, Jeungeun;Cha, Min-uk;Kim, Joo Hoon;Park, Seo-Hwa;Kim, Man Deuk;Lee, Do Yun;Rha, Sun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.166-169
    • /
    • 2016
  • Afferent loop obstruction following gastrectomy is a rare but fatal complication. Clinical features of afferent loop obstruction are mainly gastrointestinal symptoms. A 56-year-old female underwent radical total gastrectomy with Roux-en-Y esophagojejunostomy for treatment of advanced gastric cancer. After fourteen months postoperatively, she showed gradual development of edema of both legs. Computed tomography (CT) scan showed disease progression at the jejunojejunostomy site and consequent dilated afferent loop, which resulted in inferior vena cava (IVC) compression. A drainage catheter was placed percutaneously into the afferent loop through the intrahepatic duct and an IVC filter was placed at the suprarenal IVC, and self-expanding metal stents were inserted into bilateral common iliac veins. With these procedures, sympotms related with afferent loop obstruction and deep vein thrombosis were improved dramatically. The follow-up abdominal CT scan was taken 3 weeks later and revealed the completely decompressed afferent loop and improved IVC patency. Surgical treatment should be considered as the first choice for afferent loop obstruction; however, because it is more immediate and less invasive, non-surgical modalities, such as percutaneous catheter drainage or stent placement, can be effective alternatives for inoperable cases or risky patients who have severe medical comorbidities.

Planning of Dental Implant Placement Using 3D Geometric Processing and Finite Element Analysis (3차원 기하 처리와 유한요소 분석을 이용한 치아 임플란트 식립 계획 수립)

  • Park, Hyung-Wook;Park, Chul-Woo;Kim, Myong-Soo;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.4
    • /
    • pp.253-261
    • /
    • 2012
  • In order to make dental implant surgery successful, it is important to perform proper planning for dental implant placement. In this paper, we propose a decent approach to dental implant placement planning based on geometric processing of 3D models of jawbones, a nerve curve and neighboring teeth around a missing tooth. Basically, the minimum enclosing cylinders of the neighboring teeth around the missing tooth are properly used to determine the position and direction of the implant placement. The position is computed according to the radii of the cylinders and the center points of their top faces. The direction is computed by the weighted average of the axes of the cylinders. For a cylinder whose axis passes the position along the direction, its largest radius and longest length are estimated such that it does not interfere with the neighboring teeth and the nerve curve, and they are used to select the size and type of an implant fixture. From the geometric and spatial information of the jawbones, the teeth and the fixture, we can construct the 3D model of a surgical guide stent which is crucial to perform the drilling operation with ease and accuracy. We have shown the validity of the proposed approach by performing the finite element analysis of the influence of implant placement on bone stress distribution. Adopted in 3D simulation of dental implant placement, the approach can be used to provide dental students with good educational contents. It is also expected that, with further work, the approach can be used as a useful tool to plan for dental implant surgery.

Surgical Experience of Persistent Type 2 Endoleaks with Aneurysmal Sac Enlargement after Endovascular Aneurysm Repair

  • Bang, Seung Ho;Park, Jae Bum;Chee, Hyun Keun;Kim, Jun Seok;Jang, Il Soo
    • Journal of Chest Surgery
    • /
    • v.47 no.2
    • /
    • pp.167-170
    • /
    • 2014
  • Herein, we present a case of a successful treatment of persistent type 2 endoleaks associated with aneurysmal sac enlargement after endovascular aneurysm repair in an elderly patient. We confirmed the diagnosis by abdominal computed tomography and selective angiography revealing an 11.0-cm aneurysm sac with type 2 endoleaks. An attempt for the endovascular embolization of collateral arteries was unsuccessful due to anatomic variations and their multiple complex communications. Instead, transperitoneal sacotomy and direct suturing on the feeding target vessels was successfully performed without any endograft damage. In conclusion, sacotomy appears to be a feasible therapeutic substitute where endovascular or other techniques have a high risk of failure and lead to unsuccessful results.

Ureterosciatic hernia causing obstructive uropathy successfully managed with minimally invasive procedures

  • Kim, Yeong Uk;Cho, Jae Ho;Song, Phil Hyun
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.4
    • /
    • pp.337-340
    • /
    • 2020
  • Ureterosciatic hernia is extremely rare. In ureteral herniation, ureter prolapses occur through either the greater or lesser sciatic foramen. Atrophy of the piriformis muscle, hip joint diseases, and defects in the parietal pelvic fascia are predisposing factors for the development of ureterosciatic hernia. Most symptomatic patients have been treated surgically, with conservative treatment reserved only for asymptomatic patients. To the best of our knowledge, long-term follow-up outcomes after ureterosciatic hernia management are sparse. In this paper, we report the case of a 68-year-old woman who presented with colicky left abdominal pain. After computed tomography (CT) scan and anterograde pyelography, she was diagnosed ureterosciatic hernia with obstructive uropathy. We performed ureteral balloon dilatation and double-J ureteral stent placement. After this minimally invasive procedure, CT scan demonstrated that the left ureter had returned to its normal anatomical position without looping into the sciatic foramen. The patient remained asymptomatic with no adverse events 7 years after the minimally invasive procedures. This brief report describes ureterosciatic hernia successfully managed with minimally invasive procedures with long-term follow-up outcomes.

Traumatic Subclavian Artery Dissection in Clavicle Fracture Due to Blunt Injury: Surgery or Stent in Long Segment Occlusion? (둔기손상에 대한 쇄골골절에 생긴 외상성 쇄골하동맥 박리: 폐쇄가 길면 수술하느냐 또는 스텐트를 삽입하느냐?)

  • Chon, Soon-Ho;Yie, Kilsoo;Kang, Jae Gul
    • Journal of Trauma and Injury
    • /
    • v.28 no.3
    • /
    • pp.219-221
    • /
    • 2015
  • Subclavian injuries in blunt trauma are reported in less than 1% of all arterial injuries or chest related injuries. We report a female 68 yr-old patient whom has visited our emergency center due to a motorcycle traffic accident with complaints of right chest wall and shoulder pain. Her injury severity score was 22 and she was found with a comminuted clavicle fracture and subclavian artery injury. She developed delayed symptoms of pallor, pain and motor weakness with loss of pulse in her right arm. Attempts at intervention failed and thus, she underwent emergency artificial graft bypass from her subclavian artery to her brachial artery. Her postoperative course was uneventful and she is happy with the results. Although rare, a high index of suspicion for the injury must be noted and the inevitable surgical option must always be considered.

  • PDF

A Giant Pseudo-Aneurysm on the Anastomosis Site for a Redo Bentall Operation due to Behçet Disease Treated by Thoracic Endovascular Aortic Aneurysm Repair with a Custom-Made Stent Graft

  • Won, Jongyun;Jung, Jae Seung;Lee, Jun Hee;Jung, Young Ki;Son, Ho Sung
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.411-413
    • /
    • 2020
  • A 34-year-old man who had undergone aortic valve replacement 8 years ago underwent an additional Bentall operation due to mechanical valve dehiscence 2 years later. Subsequently, he was diagnosed with Behçet disease and Batter syndrome. A week after being hospitalized again due to chest pain and dyspnea, a large pseudo-aneurysm was detected on computed tomography. Because of the excessively large size of the pseudo-aneurysm, surgical treatment seemed very risky. Therefore, we planned to perform thoracic endovascular aortic repair (TEVAR) and treated him successfully. However, the patient experienced recurrence of the same symptoms 4 months later, and was found to have type IV endoleak. He received a TEVAR procedure again, and it was successful.

Posterior Cricoid Split with Costal Cartilage Grafting and T-tube Stenting for Treatment of Subglottic Stenosis (성문하협착증에서 윤상연골절개 및 윤상연골 후벽 늑연골 이식술과 T-tube stenting)

  • Sohn, Jin-Ho
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.182-190
    • /
    • 1999
  • OBJECTIVES : To determine the results of posterior cricoid split with costal cartilage graft in the treatment of moderate and severe subglottic stenosis in adults, and to assess the effect of T-tube as a stent in this surgery. PATIENTS AND METHODS : Four adults with moderate and severe subglottic stenosis who underwent posterior cricoid split with costal cartilage graft from 1994 to 1995. Three patients were male and one was female. All of the patients had acquired subglottic stenosis, 2 of whom had a bilateral vocal folds paralysis. The surgical procedure we used included a cricoid lamina split with costal cartilage grafting and T-tube stenting. Arytenoidectomy was a added in 2 patients with bilateral vocal folds paralysis. RESULTS : Three of the 4 patients underwent decannulation, and 1 is still undergoing treatment. 3 patients who underwent decannulation demonstrated marked improvement in their symptoms of airway obstruction and good postoperative voice quality. CONCLUSIONS : The posterior cricoidotomy lumen augmentation with costal cartilage grafting is a safe and effective technique for the treatment of moderate and severe subglottic stenosis in adults and T-tube is a good alternative stenting material for this procedure.

  • PDF