• Title/Summary/Keyword: Surgical Robotics

Search Result 68, Processing Time 0.026 seconds

Finite element modeling of concentric-tube continuum robots

  • Baek, Changyeob;Yoon, Kyungho;Kim, Do-Nyun
    • Structural Engineering and Mechanics
    • /
    • v.57 no.5
    • /
    • pp.809-821
    • /
    • 2016
  • Concentric-tube continuum robots have formed an active field of research in robotics because of their manipulative exquisiteness essential to facilitate delicate surgical procedures. A set of concentric tubes with designed initial curvatures comprises a robot whose workspace can be controlled by relative translations and rotations of the tubes. Kinematic models have been widely used to predict the movement of the robot, but they are incapable of describing its time-dependent hysteretic behaviors accurately particularly when snapping occurs. To overcome this limitation, here we present a finite element modeling approach to investigating the dynamics of concentric-tube continuum robots. In our model, each tube is discretized using MITC shell elements and its transient responses are computed implicitly using the Bathe time integration method. Inter-tube contacts, the key actuation mechanism of this robot, are modeled using the constraint function method with contact damping to capture the hysteresis in robot trajectories. Performance of the proposed method is demonstrated by analyzing three specifications of two-tube robots including the one exhibiting snapping phenomena while the method can be applied to multiple-tube robots as well.

Current Status of Robotic-assisted Surgery in Gastric Cancer

  • Eli Kakiashvili
    • Journal of Digestive Cancer Research
    • /
    • v.4 no.2
    • /
    • pp.99-106
    • /
    • 2016
  • Minimally invasive surgery for gastric cancer has increased in popularity during the last two decades mainly in the Asia for patients with early-stage cancer. Nevertheless, the development of laparoscopic surgery for gastric cancers in the Western world has been slow because of the advanced stage at diagnosis for which LG is not yet considered an acceptable alternative to standard open surgery. RAG has been reported as a safe alternative to conventional surgery for treating of early gastric carcinoma. We assess the current status of robotic surgery in the treatment of gastric cancer focusing on the technical details, postoperative outcome, oncological considerations and future perspectives. In gastrectomy the biggest advantage of the robotic approach is the ease and reproducibility of lymphadenectomy. Reports also show that even the intra corporeal digestive restoration is facilitated by use of the robotic approach, particularly following TG. Additionally, the accuracy of robotic dissection is confirmed by decreased blood loss in comparison to conventional laparoscopy. The learning curve and technical reproducibility also appear to be shorter with robotic surgery and, consequently, robotics can help to standardize and diffuse minimally invasive surgery in the treatment of gastric cancer. While published reports have shown no significant differences in surgical morbidity, mortality, or oncological adequacy between robot-assisted and conventional gastrectomy. There are some advantages in terms of postoperative recovery of patients after robotic surgery. More studies are needed to assess the true indications and oncological effectiveness of robotic use in the treatment of gastric carcinoma.

  • PDF

The First 20 Cases of Cardiac Surgery Using the da $Vinci^{TM}$ Surgical System: A Single Center Experience (다빈치 수술로봇을 이용한 심장수술 20예 보고 - 단일 기관 보고 -)

  • Je, Hyoung-Gon;Lee, Yong-Jik;Jung, Sung-Ho;Jung, Jae-Seung;Kang, Pil-Je;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Background: The interest in robotic cardiac surgery has recently grown but there has not been much clinical research reported on this. The aim of this study is to examine our initial experience, since August 2007, with robotic cardiac surgery using the da $Vince^{TM}$ surgical system and to evaluate the feasibility and safety of it. Material and Method: Between August and December 2007, a total of 20 patients underwent robotic cardiac surgery using the da Vinci surgical system. For mitral valve repair (n=11), tricuspid valve repair (n=1), and ASD repair (n=1), cannulation, antegrade cardioplegia and transthoracic aortic cross-clamping were conducted for the right femoral vessels and the right internal jugular vein. For minimally invasive direct CABG (MIDCAB) (n=7), the internal thoracic artery (ITA) was harvested with the da Vinci surgical system. Result: The mean age of the patients was 50.1 (range: $26{\sim}78$) years. Three concomitant Maze procedures and one tricuspid annuloplasty were combined with mitral valve repair. The mean cardiopulmonary bypass time was $208.0{\pm}61.3$ minutes and the aortic cross clamp time was $158.8{\pm}40.6$ minutes. No patients showed more than mild mitral regurgitation after repair and the median hospital stay was 4 days. The robotic-harvested ITA was used for either left ITA (n=6) or bilateral ITA (n=1). The mean harvest time was $43.2{\pm}12.0$ minutes. The harvested ITA showed good flow and it was anastomosed under direct vision after left anterolateral thoracotomy. The patency of all the grafts was 100% (18/18) in MIDCAB. Conclusion: Robotic cardiac surgery using the da Vinci surgical system was variously adapted to areas such as mitral and tricuspid valve repair, ASD repair and ITA harvest for MIDCAB. The early results of the robotic cardiac surgery showed its safety and feasibility. With this primary report, we anticipate that clinical applications and further studies on robotic cardiac surgery using the da Vinci surgical system will be actively conducted in Korea.

Da Vinci Robot-Assisted Pulmonary Lobectomy in Early Stage Lung Cancer - 3 cases report - (조기 폐암에서 다빈치 로봇을 이용한 폐엽절제술 - 3예 보고 -)

  • Haam, Seok-Jin;Lee, Kyo-Joon;Cho, Sang-Ho;Kim, Hyung-Joong;Jeon, Se-Eun;Lee, Doo-Yun
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.659-662
    • /
    • 2008
  • Video-assisted pulmonary lobectomy was introduced in the early 1990's by several authors, and the frequency of video-assisted thoracic surgery (VATS) lobectomy for lung cancer has been slowly increasing because of its safety and oncologic acceptability in patients with early stage lung cancer However, VATS is limited by 2D imaging, an unsteady camera platform, and limited maneuverability of its instruments. The da Vinci Surgical System was recently introduced to overcome these limitations. It has a 3D endoscopic system with high resolution and magnified binocular views and EndoWrist instruments. We report three cases of da Vinci robot system-assisted pulmonary lobectomy in patients with early stage lung cancer.

Robot-Assisted Free Flap in Head and Neck Reconstruction

  • Song, Han Gyeol;Yun, In Sik;Lee, Won Jai;Lew, Dae Hyun;Rah, Dong Kyun
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.353-358
    • /
    • 2013
  • Background Robots have allowed head and neck surgeons to extirpate oropharyngeal tumors safely without the need for lip-split incision or mandibulotomy. Using robots in oropharyngeal reconstruction is new but essential for oropharyngeal defects that result from robotic tumor excision. We report our experience with robotic free-flap reconstruction of head and neck defects to exemplify the necessity for robotic reconstruction. Methods We investigated head and neck cancer patients who underwent ablation surgery and free-flap reconstruction by robot. Between July 1, 2011 and March 31, 2012, 5 cases were performed and patient demographics, location of tumor, pathologic stage, reconstruction methods, flap size, recipient vessel, necessary pedicle length, and operation time were investigated. Results Among five free-flap reconstructions, four were radial forearm free flaps and one was an anterolateral thigh free-flap. Four flaps used the superior thyroid artery and one flap used a facial artery as the recipient vessel. The average pedicle length was 8.8 cm. Flap insetting and microanastomosis were achieved using a specially manufactured robotic instrument. The total operation time was 1,041.0 minutes (range, 814 to 1,132 minutes), and complications including flap necrosis, hematoma, and wound dehiscence did not occur. Conclusions This study demonstrates the clinically applicable use of robots in oropharyngeal reconstruction, especially using a free flap. A robot can assist the operator in insetting the flap at a deep portion of the oropharynx without the need to perform a traditional mandibulotomy. Robot-assisted reconstruction may substitute for existing surgical methods and is accepted as the most up-to-date method.

DaVinci SP-based simultaneous bilateral partial nephrectomy from the midline transperitoneal approach: a case report

  • Young Hwii Ko;Jong Gyun Ha;Jae Yoon Jang;Yeung Uk Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.1
    • /
    • pp.48-52
    • /
    • 2024
  • While simultaneous bilateral partial nephrectomy with a conventional multiport robot has been consistently reported since the 2010s, the introduction of the DaVinci SP system (Intuitive Surgical, Sunnyvale, CA, USA) could provide a novel way to perform surgery on bilateral kidneys while innovatively reducing the number of incisions. In our first report worldwide, the patient with bilateral small renal mass (2.0 cm for the left and 1.5 cm for the right side) and preoperative normal renal function was placed in the lateral decubitus position on an inverted bed. After tilting the bed to be as horizontal as possible, a 4-cm incision was made in the lower part of the umbilicus for the floating trocar technique. The partial nephrectomy was performed reliably as with the conventional transperitoneal approach, and then the patient could be repositioned to the contralateral side for the same procedure, maintaining all trocars. Total operation time (skin to skin), total console time, and the left- and right-side warm ischemic times were 260, 164, 27, and 23 minutes, respectively, without applying the early declamping technique. The estimated blood loss was 200 mL. The serum creatinine right after the operation, on the first day, 3 days, and 90 days after surgery were 0.92, 0.77, 0.79, and 0.81 mg/dL, respectively. For 90 days after the procedure, no complications or radiologic recurrence were observed. Further clinical studies will reveal the advantages of using the DaVinci SP device for this procedure over traditional multiport surgery, maximizing the benefit of a single port-based approach.

Parametric Study on the tendency of Stiffness Variation using Variable Stiffness Mechanism (변수변화에 따른 가변강성 메커니즘의 강성변화 경향성에 관한 연구)

  • Ham, KiBeom;Han, Jiho;Jeon, JongKyun;Park, YongJai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.750-758
    • /
    • 2016
  • In general, a system can be stable when it is designed with a rigid material. However, the use of a rigid system can be limited, such as grasping a glass or using a small surgical instrument. To resolve this limitation, a variable stiffness mechanism was developed using a flexible material. Previous research verified the variable stiffness mechanism where flexible segments and rigid segments were connected alternately in series. However, research into the design parameters of the variable stiffness structure is needed to satisfy the desired stiffness. Therefore, a variable stiffness structure was tested by varying the design parameters to confirm the trend of the stiffness variation. When the radius of the structure becomes larger, the stiffness increases. The stiffness increased with decreasing length of the flexible segments. Under the same design parameters, the length of the flexible segments had a greater effect on the stiffness than the length of the rigid segments. In addition, the stiffness was estimated using the pseudo rigid body model and was compared with the experimental results. This parametric study can be used as a design guideline for designing the variable stiffness mechanism to satisfy the desired stiffness.

Comparison of the Operative Results of Performing Endoscopic Robot Assisted Minimally Invasive Surgery Versus Conventional Cardiac Surgery (수술용 내시경 로봇(AESOP)을 이용한 최소 침습적 개심술과 동 기간에 시행된 전통적인 개심술의 결과에 대한 비교)

  • Lee, Young-Ook;Cho, Joon-Yong;Lee, Jong-Tae;Kim, Gun-Jik
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.598-604
    • /
    • 2008
  • Background: The improvements in endoscopic equipment and surgical robots has encouraged the performance of minimally invasive cardiac operations. Yet only a few Korean studies have compared this procedure with the sternotomy approach. Material and Method: Between December 2005 and July 2007, 48 patients (group A) underwent minimally invasive cardiac surgery with AESOP through a small right thoracotomy. During the same period, 50 patients (group B) underwent conventional surgery. We compared the operative time, the operative results, the post-operative pain and the recovery of both groups. Result: There was no hospital mortality and there were no significant differences in the incidence of operative complications between the two groups. The operative $(292.7{\pm}61.7\;and\;264.0{\pm}47.9min$, respectively; p=0.01) and CPB times ($128.4{\pm}37.6\;and\;101.7{\pm}32.5min$, respectively; <0.01) were longer for group A, whereas there was no difference between the aortic cross clamp times ($82.1{\pm}35.0\;and\;87.8{\pm}113.5min$, respectively; p=0.74) and ventilator times ($18.0{\pm}18.4\;and\;19.7{\pm}9.7$ hr, respectively; p=0.57) between the groups. The stay on the ICU $(53.2{\pm}40.2\;and\;72.8{\pm}42.1hr$, respectively; p=0.02) and the hospitalization time ($9.7{\pm}7.2\;and\;14.8{\pm}11.9days$, respectively; p=0.01) were shorter for group A. The Patients in group B had more transfusions, but the difference was not significant. For the overall operative intervals, which ranged from one to four weeks, the pair score was significantly lower for the patients of group A than for the patients of group B. In terms of the postoperative activities, which were measured by the Duke Activity Scale questionnaire, the functional status score was clearly higher for group A compared to group B. The analysis showed no difference in the severity of either post-repair of mitral ($0.7{\pm}1.0\;and\;0.9{\pm}0.9$, respectively; p=0.60) and tricuspid regurgitation ($1.0{\pm}0.9\;and\;1.1{\pm}1.0$, respectively; p=0.89). In both groups, there were no valve related complications, except for one patient with paravalvular leakage in each group. Conclusion: These results show that compared with the median sternotomy patients, the patients who underwent minimally invasive surgery enjoyed significant postoperative advantages such as less pain, a more rapid return to full activity, improved cosmetics and a reduced hospital stay. The minimally invasive surgery can be done with similar clinical safety compared to the conventional surgery that's done through a median sternotomy.