• 제목/요약/키워드: Surgery robot

검색결과 129건 처리시간 0.027초

Development of Dual-Arm Anticancer Drug Compounding Robot and Preparation System with Adaptability and High-Speed

  • Nam, Giyoon;Kim, Young Joo;Kim, Yun Jung;Kim, Yeoun Jae;Seo, Jung Ae;Kim, Kyunghwan;Kim, Kwang Gi
    • Journal of International Society for Simulation Surgery
    • /
    • 제3권2호
    • /
    • pp.64-68
    • /
    • 2016
  • Aim Robots are able to increase safety for pharmacy staff as separating from toxicity of anti-cancer drugs. For patient safety, it would provide right dose of the drugs. Additionally, it can reduce price of the drugs. Therefore, in this study, a novel compounding anticancer drugs robot system (Dupalro) was developed. Methods We used the robot system, Motoman dual-arm robot from YASKAWA, Japan and medications which are adapted for the robot were constructed. In order to develop a process of compounding anticancer drugs, information about five medications that are required to make anticancer drugs in hospitals was used. Results System for the five types of medications was constructed, and relating procedures for anticancer drugs compounding robot were developed. Conclusion Dupalro successfully was able to not only provide incremental safety and efficiency for both patients and pharmacy staff, but also decrease price of anticancer drugs.

복강경 수술을 위한 지능형 작동기의 제작 (Design of Dexterous Manipulator for MIS)

  • 송호석;정종하;이정주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.823-828
    • /
    • 2004
  • Minimally Invasive Surgery (MIS) is surgery of the chest, abdomen, spine and pelvis, done with the aid of a viewing scope, and specially designed instruments. Benefits of minimally invasive surgery are less pain, less need for post-surgical pain medication, less scarring and less likelihood for incisional complications. Since the late 1980's, minimally invasive surgery has gained widespread acceptance because of the such advantages. However there are significant disadvantages which have, to date, limited the applications for these promising techniques. The reasons are limited degree-of-freedom, reduced dexterity and the lack of tactile feeling. To overcome such disadvantages many researchers have endeavored to develop robotic systems. Even though some robot aided systems achieved success and commercialized, there still remain many thing to be improved. In this paper, the robotic system which can mimic whole motions of a human arm by adding additional DOF is presented. The suggested design is expected to provide surgeons with improved dexterity during minimally invasive surgery.

  • PDF

Is Robot-Assisted Surgery Really Scarless Surgery? Immediate Reconstruction with a Jejunal Free Flap for Esophageal Rupture after Robot-Assisted Thyroidectomy

  • Park, Seong Hoon;Kim, Joo Hyun;Lee, Jun Won;Jeong, Hii Sun;Lee, Dong Jin;Kim, Byung Chun;Suh, In Suck
    • Archives of Plastic Surgery
    • /
    • 제44권6호
    • /
    • pp.550-553
    • /
    • 2017
  • Esophageal perforation is a rare but potentially fatal complication of robot-assisted thyroidectomy (RAT). Herein, we report the long-term outcome of an esophageal reconstruction with a jejunal free flap for esophageal rupture after RAT. A 33-year-old woman developed subcutaneous emphysema and hoarseness on postoperative day1 following RAT. Esophageal rupture was diagnosed by computed tomography and endoscopy, and immediate surgical exploration confirmed esophageal rupture, as well as recurrent laryngeal nerve injury. We performed a jejunal free flap repair of the 8-cm defect in the esophagus. End-to-side microvascular anastomoses were created between the right external carotid artery and the jejunal branches of the superior mesenteric artery, and end-to-end anastomosis was performed between the external jugular vein and the jejunal vein. The right recurrent laryngeal nerve injury was repaired with a 4-cm nerve graft from the right ansa cervicalis. Esophagography at 1 year after surgery confirmed that there were no leaks or structures, endoscopy at 1 year confirmed the resolution of vocal cord paralysis, and there were no residual problems with swallowing or speech at a 5-year follow-up examination. RAT requires experienced surgeons with a thorough knowledge of anatomy, as well as adequate resources to quickly and competently address potentially severe complications such as esophageal rupture.

Design of a Compact Laparoscopic Assistant Robot;KaLAR

  • Lee, Yun-Ju;Kim, Jona-Than;Ko, Seong-Young;Lee, Woo-Jung;Kwon, Dong-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2648-2653
    • /
    • 2003
  • This paper describes the development of a 3-DOF laparoscopic assistant robot system with motor-controlled bending and zooming mechanisms using the voice command motion control and auto-tracking control. The system is designed with two major criteria: safety and adaptability. To satisfy the safety criteria we designed the robot with optimized range of motion. For adaptability, the robot is designed with compact size to minimize interference with the staffs in the operating room. The required external motions were replaced by the bending mechanism within the abdomen using flexible laparoscope. The zooming of the robot is achieved through in and out motion at the port where the laparoscope is inserted. The robot is attachable to the bedside using a conventional laparoscope holder with multiple DOF joints and is compact enough for hand-carry. The voice-controlled command input and auto-tracking control is expected to enhance the overall performance of the system while reducing the control load imposed on the surgeon during a laparoscopic surgery. The proposed system is expected to have sufficient safety features and an easy-to-use interface to enhance the overall performance of current laparoscopy.

  • PDF

식도암 환자에서 da Vinci 로봇을 이용한 식도암 수술 (흉골하 통로를 통한 식도-위 문합술) - 1예 보고 - (da Vinci Robot-Assisted Esophagectomy for Esophageal Cancer: A Case of Esophago-gastrostomy through the Retrosternal Route - A case report -)

  • 정상석;최필조;우종수;김시호;방정희;박권재
    • Journal of Chest Surgery
    • /
    • 제42권3호
    • /
    • pp.396-400
    • /
    • 2009
  • 다빈치 로봇수술은 현재 다양한 외과영역에서 시행되고 있으나 폐, 식도 외과영역에서는 아직까지 널리 이용되지 않고 있다. 본원에서는 74세 남자환자가 딸꾹질과 연하곤란을 주소로 내원하여 시행한 검사에서 식도암으로 진단되어 da Vinci 로봇을 이용하여 식도절제술을 시행한 후, 복강경으로 위장튜브를 만들어 흉골하 통로를 통해 경부에서 위장-식도 단단 문합을 시행하였다. 환자는 수술 후 특별한 합병증 없이 완쾌 퇴원하였다. 향후 다빈치로봇을 이용한 최소 침습수술이 식도암을 비롯한 폐, 식도외과 영역에의 활용에 있어서 좋은 결과가 기대되므로 보고하는 바이다.

두경부 영역에서의 로봇 수술 (Robotic Surgery in Head and Neck)

  • 태경;신광수
    • 대한기관식도과학회지
    • /
    • 제16권1호
    • /
    • pp.27-32
    • /
    • 2010
  • Organ preservation surgery and minimally invasive surgery have been developed during the past 20 years with major focus on transoral laser surgery, endoscopic surgery, and robotic surgery. Two major robotic surgeries in head and neck area are transoral robotic surgery (TORS) and robotic thyroidectomy. Transoral robotic surgery is a safe and efficacious method of surgical treatment of oropharyngeal. hypopharyngeal and laryngeal neoplasm. Advantages of the technique include adequate ability to visualize and manipulate lesions with two hands. TORS can provide magnified three dimensional views and overcome the limitation resulting from the "line of sight" which hinders transoral laser procedure. The swallowing function following transoral robotic surgery show superior and patients were able to retain or rapidly regain swallowing function in the majority of cases. Recently, robotic thyroidectomy has also been developed to overcome the [imitation of endoscopic thyroidectomy. Robotic thyroidectomy by a gasless unilateral axillo-breast or axillary approach using a da Vinci S Surgical Robot is a feasible and cosmetically excellent procedure. It can be a promising alternative to endoscopic thyroidectomy or conventional open thyroidectomy.

  • PDF

Computer Integrated Surgical Robot System for Spinal Fusion

  • Kim Sungmin;Chung Goo Bong;Oh Se Min;Yi Byung-Ju;Kim Whee Kuk;Park Jong Il;Kim Young Soo
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.265-270
    • /
    • 2005
  • A new Computer Integrated Surgical Robot system is composed of a surgical robot, a surgical planning system, and an optical tracking system. The system plays roles of an assisting surgeon and taking the place of surgeons for inserting a pedicle screw in spinal fusion. Compared to pure surgical navigation systems as well as conventional methods for spinal fusion, it is able to achieve better accuracy through compensating for the portending movement of the surgical target area. Furthermore, the robot can position and guide needles, drills, and other surgical instruments or conducts drilling/screwing directly. Preoperatively, the desired entry point, orientation, and depth of surgical tools for pedicle screw insertion are determined by the surgical planning system based on CT/MR images. Intra-operatively, position information on surgical instruments and targeted surgical areas is obtained from the navigation system. Two exemplary experiments employing the developed image-guided surgical robot system are conducted.

뇌정위 수술 보조 로봇 시스템의 안전성과 유효성: 체계적 문헌고찰 (Effectiveness and Safety of Robot-Assisted Brain Stereotactic Surgery: A Systematic Review)

  • 박선영;전미혜
    • 보건의료기술평가
    • /
    • 제6권2호
    • /
    • pp.142-147
    • /
    • 2018
  • Objectives: The purpose of this study is to evaluate the safety and effectiveness of Robot-Assisted Brain Stereotactic Surgery with a systematic review. Methods: Electronic literature was searched using KoreaMed, Ovid-MEDLINE, Ovid-EMBASE, and Cochrane Library on 6th April 2017. Two authors screened 1218 citations. Duplicated articles of 456 excluded, the remaining 762 articles were reviewed with title and abstract. Results: A total of 8 studies were selected in this review. The device used in all studies was $ROSA^{TM}$. In one cohort study comparing the intervention ($ROSA^{TM}$) with the control (conventional stereotactic surgery), hematoma was reported no significant difference between groups. In six descriptive studies, one study reported hematoma 10% (10/100) and temporary nerve impairment 6% (6/100) using the ROSA; while five descriptive study did not report any complications. In one cohort, the localization precision were 1.2 mm in the intervention group and 1.1 mm in the control group; the localization success rate as 78.2% in the intervention group and 76.2% in the control group in one cohort; and the average time for surgery as 130 min for the intervention group and 352 min for the control group in one cohort. Four studies reported the localization success rate as 100%; two out of three articles reported the overall time for surgery as 56 min and 90 min, while one article reported the time as less than one hour in 50% of patients (50/100); two articles reported in epilepsy patients, the condition after the surgery was Engel level I in 66.2%, 75% patients, Engel level II-III in 25%, 26.5% patients, and Engel level 4 in 7.3% patients. Conclusion: Robot-Assisted Brain Stereotactic Surgery is a safe and accurate technique that can significantly reduce the time for the brain stereotactic surgery. However, further studies are needed to generalize the results.

정형외과 영역에서 로봇수술 (Robotic Surgery in the Orthopedic Field)

  • 이우석;정우석
    • 대한정형외과학회지
    • /
    • 제53권6호
    • /
    • pp.459-465
    • /
    • 2018
  • 정형외과 수술의 임상적 결과에 영향을 미치는 요소는 여러 가지가 있지만 수술적 수기가 가장 중요한 요인이며 로봇공학은 술기를 보다 정확하고 일관되게 수행하기 위해 도입되었다. 정형외과 영역에서는 20년 전부터 로봇수술을 사용하였으나 실용성 문제와 합병증의 발생으로 일부 로봇은 도태되었으며 단점을 개선한 로봇이 소개되고 있다. 대부분의 로봇수술은 인공관절수술 분야에서 시행되었고 치환물의 정렬과 위치 선정에서 우수한 것으로 보고되고 있다. 그러나 임상적 결과의 우수성, 실용성, 가성비 등의 측면에서 제한점이 있고 일부 로봇수술에서는 합병증 발생 빈도가 높다는 보고가 있었다. 초기 로봇수술은 수술자의 개입 없이 계획된 수술이 진행되는 능동형 로봇수술이 주를 이루었으나 최근에는 수술과정에서 실시간 피드백을 통해 술자가 술 전 계획을 변경할 수 있고, 햅틱 경계 내에서 제한된 골절제를 함으로써 주요 혈관, 신경, 인대 등의 손상을 최소화할 수 있는 반능동형 로봇수술이 소개되고 있다.

C-arm 영상 기반 척추 디스크 내시경 수술을 위한 가이드 바늘 삽입 보조 시스템 (Method for C-arm Based Guide Needle Insertion Assistant System for Endoscopic Disc Surgery)

  • 윤현민;조현철;박규식;신상균;이득희
    • 한국CDE학회논문집
    • /
    • 제20권3호
    • /
    • pp.263-268
    • /
    • 2015
  • Due to an increased sitting time in work, lumbar disc disease is one of the most frequent diseases in modern days, and this occasionally requires surgery for treatment. Endoscopic disc surgery, one of the common disc surgeries, requires a process of inserting a guide needle to the target disc for which the insertion path is manually planned by drawing lines on the patient's skin while monitoring the fluoroscopic view of the lumbar. Such procedure inevitably exposes both surgeon and patient to the fluoroscopy radiation emitted from the c-arm for a long time. To reduce the radiation exposure time, this study proposes a computer assisted method of calculating the 3D guide needle path by using 2D c-arm images of the disc in 3 different angles. Additionally, a method of the guide robot control based on the 3D needle path was developed by implementing the Hand-eye Calibration method to calculate the transformation matrix between the c-arm and robot base coordinate systems. The proposed system was then tested for its accuracy.